Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Nanoscale optical tomography with cathodoluminescence spectroscopy

In one aspect, a cathodoluminescence (CL) spectroscopic tomography device includes a sample stage to support a sample. An electron beam source scans an electron beam over the sample to yield light emission by the sample. A reflective element directs the light emission by the sample to a light detector. A controller controls operation of the sample stage, the electron beam source, and the light detector. In one aspect, a CL spectroscopic tomography device includes an electron beam source which directs an electron beam at an object to yield an emission by the object. A detector detects the emission. A controller receives information from the detector related to the detected emission. The controller derives a two-dimensional (2D) CL map from the information related to the detected emission, and derives a three-dimensional (3D) CL tomogram from the 2D CL map.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-92: Is Photon Starvation Preventing Metal Artifact Reduction Algorithm From Working in KVCT?

Purpose: High density/high atomic number metallic objects create shading and streaking metal artifacts in the CT image that can cause inaccurate delineation of anatomical structures or inaccurate radiation dose calculation. A modified iterative maximum-likelihood polychromatic algorithm for CT (mIMPACT) that models the energy response of detectors, photon interaction processes and beam polychromaticity has successfully reduced metal artifacts in MVCT. Our extension of mIMPACT in kVCT did not significantly reduce metal artifacts for high density metal like steel. We hypothesize that photon starvation may result in the measured data in a commercial kVCT imaging beam. Methods: We measured attenuation of a range of steel plate thicknesses, sandwiched between two 12cm thick solid water blocks, using a Phillips Big Bore CTTM scanner in scout acquisition mode with 120kVp and 200mAs. The transmitted signal (y) was normalized to the air scan signal (y{sub 0}) to get attenuation [i.e., ln(y/y{sub 0})] data for a detector. Results: Below steel plate thickness of 13.4mm, the variations in measured attenuation as a function of view number are characterized by a quantum noise and show increased attenuation with metal thickness. On or above this thickness the attenuation shows discrete levels in addition to the quantum noise. Some views have saturated attenuation value. The histograms of the measured attenuation for up to 36.7mm of steel show this trend. The detector signal is so small that the quantization levels in the analog to digital (A-to-D) converter are visible, a clear indication of photon starvation. Conclusion: Photons reaching the kVCT detector after passing through a thick metal plate are either so low in number that the signal measured has large quantum noise, or are completely absorbed inside the plate creating photon starvation. This is un-interpretable by the mIMPACT algorithm and cannot reduce metal artifacts in kVCT for certain realistic thicknesses of steel hip implants. Moti Raj Paudel is supported by the Vanier Canada Graduate Scholarship, the Endowed Graduate Scholarship in Oncology and the Dissertation Fellowship at the University of Alberta. The authors acknowledge the CIHR operating grant number MOP 53254.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-Vivo Real-Time X-ray {mu}-Imaging

The technique of X-ray transmission imaging is available for more than 100 years and it is still one of the fastest and easiest ways how to study the internal structure of living biological samples. The advances in semiconductor technology in last years make possible to fabricate new types of X-ray detectors with direct conversion of interacting X-ray photon to an electric signal. Especially semiconductor pixel detectors seem to be very promising. Compared to the film technique they bring single-quantum and real-time digital information about the studied object with high resolution, high sensitivity and broad dynamic range. These pixel detector-based imaging stand promising as a new tool in the field of small animal imaging, for cancer research and for observation of dynamic processes inside organisms. These detectors open up for instance new possibilities for researchers to perform non-invasive studies of tissue for mutations or pathologies and to monitor disease progression or response to therapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A technique for measuring the quality of an elliptically bent pentaerythritol [PET(002)] crystal

We present a technique for determining the X-ray spectral quality from each region of an elliptically curved PET(002) crystal. The investigative technique utilizes the shape of the crystal rocking curve which changes significantly as the radius of curvature changes. This unique quality information enables the spectroscopist to verify where in the spectral range that the spectrometer performance is satisfactory and where there are regions that would show spectral distortion. A collection of rocking curve measurements for elliptically curved PET(002) has been built up in our X-ray laboratory. The multi-lamellar model from the XOP software has been used as a guide and corrections were applied to the model based upon measurements. But, the measurement of R{sub I} at small radius of curvature shows an anomalous behavior; the multi-lamellar model fails to show this behavior. The effect of this anomalous R{sub I} behavior on an X-ray spectrometer calibration is calculated. It is compared to the multi-lamellar model calculation which is completely inadequate for predicting R{sub I} for this range of curvature and spectral energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Is the Matrix Completion of Reduced Density Matrices Unique?

Reduced density matrices are central to describing observables in many-body quantum systems. In electronic structure theory, the two-particle reduced density matrix (2-RDM) suffices to determine the energy and other key properties. Recent work has used matrix completion, leveraging the low-rank structure of RDMs and approximate theoretical models, to reconstruct the 2-RDM from partial data and thus reduce the computational cost. However, matrix completion is, in general, an under-determined problem. Revisiting Rosina’s theorem (Rosina, M. Queen’s Papers on Pure and Applied Mathematics , 1968, No. 11, 369), we here show that the matrix completion is unique under certain conditions, identifying the subset of 2-RDM elements that enables its exact reconstruction from incomplete information. Building on this, we introduce a hybrid quantum–stochastic algorithm that achieves exact matrix completion, demonstrated through applications to the Fermi–Hubbard model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photon self-induced spin-to-orbital conversion in a terbium-gallium-garnet crystal at high laser power

In this paper, we present experimental evidence of a third-order nonlinear optical process, self-induced spin-to-orbital conversion (SISTOC) of the photon angular momentum. This effect is the physical mechanism at the origin of the depolarization of very intense laser beams propagating in isotropic materials. The SISTOC process, like self-focusing, is triggered by laser heating leading to a radial temperature gradient in the medium. In this work we tested the occurrence of SISTOC in a terbium-gallium-garnet rod for an impinging laser power of about 100 W. To study the SISTOC process we used different techniques: polarization analysis, interferometry, and tomography of the photon orbital angular momentum. Our results confirm, in particular, that the apparent depolarization of the beam is due to the occurrence of maximal entanglement between the spin and orbital angular momentum of the photons undergoing the SISTOC process. This explanation of the true nature of the depolarization mechanism could be of some help in finding novel methods to reduce or to compensate for this usually unwanted depolarization effect in all cases where very high laser power and good beam quality are required.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shedding light on shadow generalized parton distributions

The feasibility of extracting generalized parton distributions (GPDs) from deeply virtual Compton scattering (DVCS) data has recently been questioned because of the existence of an infinite set of so-called “shadow GPDs” (SGPDs). These SGPDs depend on the process and manifest as multiple solutions (at a fixed scale 𝑄 2 ) to the inverse problem that needs to be solved to infer GPDs from DVCS data. SGPDs therefore pose a significant challenge for extracting GPDs from DVCS data. With this motivation we study the extent to which QCD evolution can provide constraints on SGPDs. This is possible because the known classes of SGPDs begin to contribute to observables after evolution, and can then be constrained (at the input scale 𝑄$^{2}_{0}$) by data that has a finite 𝑄 2 range. The impact that SGPDs could have on determining the total angular momentum, pressure and sheer force distributions, and tomography is also discussed. We find that 𝑄 2 evolution, given empirical data over a wide range of skewness (𝜉 ) and 𝑄 2 scales, constrains the SGPDs studied at low 𝑥 and low 𝜉. If this finding generalizes to all SGPDs—and we have not been able to find any SGPDs with qualitatively different behavior—then this potentially makes extraction of GPDs from DVCS possible over a limited range of 𝑥 and 𝜉.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Image simulation and a model of noise power spectra across a range of mammographic beam qualities

Purpose: The aim of this work is to create a model to predict the noise power spectra (NPS) for a range of mammographic radiographic factors. The noise model was necessary to degrade images acquired on one system to match the image quality of different systems for a range of beam qualities. Methods: Five detectors and x-ray systems [Hologic Selenia (ASEh), Carestream computed radiography CR900 (CRc), GE Essential (CSI), Carestream NIP (NIPc), and Siemens Inspiration (ASEs)] were characterized for this study. The signal transfer property was measured as the pixel value against absorbed energy per unit area (E) at a reference beam quality of 28 kV, Mo/Mo or 29 kV, W/Rh with 45 mm polymethyl methacrylate (PMMA) at the tube head. The contributions of the three noise sources (electronic, quantum, and structure) to the NPS were calculated by fitting a quadratic at each spatial frequency of the NPS against E. A quantum noise correction factor which was dependent on beam quality was quantified using a set of images acquired over a range of radiographic factors with different thicknesses of PMMA. The noise model was tested for images acquired at 26 kV, Mo/Mo with 20 mm PMMA and 34 kV, Mo/Rh with 70 mm PMMA for three detectors (ASEh, CRc, and CSI) over a range of exposures. The NPS were modeled with and without the noise correction factor and compared with the measured NPS. A previous method for adapting an image to appear as if acquired on a different system was modified to allow the reference beam quality to be different from the beam quality of the image. The method was validated by adapting the ASEh flat field images with two thicknesses of PMMA (20 and 70 mm) to appear with the imaging characteristics of the CSI and CRc systems. Results: The quantum noise correction factor rises with higher beam qualities, except for CR systems at high spatial frequencies, where a flat response was found against mean photon energy. This is due to the dominance of secondary quantum noise in CR. The use of the quantum noise correction factor reduced the difference from the model to the real NPS to generally within 4%. The use of the quantum noise correction improved the conversion of ASEh image to CRc image but had no difference for the conversion to CSI images. Conclusions: A practical method for estimating the NPS at any dose and over a range of beam qualities for mammography has been demonstrated. The noise model was incorporated into a methodology for converting an image to appear as if acquired on a different detector. The method can now be extended to work for a wide range of beam qualities and can be applied to the conversion of mammograms.

60 APPLIED LIFE SCIENCES↗

Determining and Controlling the Magnesium Composition in CdTe/CdMgTe Heterostructures

The relationships between Mg composition, band gap, and lattice characteristics are investigated for Cd 1-x Mg x Te barrier layers using a combination of cathodoluminescence, energy dispersive x-ray spectroscopy, variable angle spectral ellipsometry, and atom probe tomography. The use of a simplified, yet accurate, variable angle spectral ellipsometry analysis is shown to be appropriate for fast determination of composition in thin Cd 1-x Mg x Te layers. The validity of using high-resolution x-ray diffraction for CdTe/Cd 1-x Mg x Te double heterostructures is discussed. Furthermore, the stability of CdTe/Cd 1-x Mg x Te heterostructures are investigated with respect to thermal processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic characterization of Au clusters in vapor-liquid-solid grown silicon nanowires

By correlating atom probe tomography with other conventional microscope techniques (scanning electron microscope, scanning transmission electron microscope, and scanning tunneling microscopy), the distribution and composition of Au clusters in individual vapor-liquid-solid grown Si nanowires is investigated. Taking advantage of the characteristics of atom probe tomography, we have developed a sample preparation method by inclining the sample at certain angle to characterize the nanowire sidewall without using focused ion beam. With three-dimensional atomic scale reconstruction, we provide direct evidence of Au clusters tending to remain on the nanowire sidewall rather than being incorporated into the Si nanowires. Based on the composition measurement of Au clusters (28% ± 1%), we have demonstrated the supersaturation of Si atoms in Au clusters, which supports the hypothesis that Au clusters are formed simultaneously during nanowire growth rather than during the cooling process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beyond Darcy's law: The role of phase topology and ganglion dynamics for two-fluid flow

Relative permeability quantifies the ease at which immiscible phases flow through porous rock and is one of the most well known constitutive relationships for petroleum engineers. It however exhibits troubling dependencies on experimental conditions and is not a unique function of phase saturation as commonly accepted in industry practices. The problem lies in the multi-scale nature of the problem where underlying disequilibrium processes create anomalous macroscopic behavior. Here we show that relative permeability rate dependencies are explained by ganglion dynamic flow. We utilize fast X-ray micro-tomography and pore-scale simulations to identify unique flow regimes during the fractional flow of immiscible phases and quantify the contribution of ganglion flux to the overall flux of non-wetting phase. We anticipate our approach to be the starting point for the development of sophisticated multi-scale flow models that directly link pore-scale parameters to macro-scale behavior. Such models will have a major impact on how we recover hydrocarbons from the subsurface, store sequestered CO 2 in geological formations, and remove non-aqueous environmental hazards from the vadose zone.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fireball tomography from bottomonia elliptic flow in relativistic heavy-ion collisions

Abstract We calculate the elliptic flow of bottomonia produced in Pb $$\,+\,$$ + Pb collisions at $$\sqrt{s_{\mathrm{NN}}}=5.02$$ s NN = 5.02 TeV. We consider temperature-dependent decay widths for the anisotropic escape of various bottomonium states and observe that the transverse momentum dependence of bottomonia elliptic flow provides a tomographic information about the QGP fireball at different stages of its evolution. For the space-time evolution of the fireball, we employ simulation results from the 3 + 1 D quasiparticle anisotropic hydrodynamic model. We find that our results for transverse momentum dependence of bottomonia elliptic flow are in reasonable agreement with experimental results from the ALICE and CMS collaborations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nuclear photonics

With the planned new {gamma}-beam facilities like MEGa-ray at LLNL (USA) or ELI-NP at Bucharest (Romania) with 10{sup 13}{gamma}/s and a band width of {Delta}E{gamma}/E{gamma} Almost-Equal-To 10{sup -3}, a new era of {gamma} beams with energies up to 20MeV comes into operation, compared to the present world-leading HI{gamma}S facility at Duke University (USA) with 10{sup 8}{gamma}/s and {Delta}E{gamma}/E{gamma} Almost-Equal-To 3 Dot-Operator 10{sup -2}. In the long run even a seeded quantum FEL for {gamma} beams may become possible, with much higher brilliance and spectral flux. At the same time new exciting possibilities open up for focused {gamma} beams. Here we describe a new experiment at the {gamma} beam of the ILL reactor (Grenoble, France), where we observed for the first time that the index of refraction for {gamma} beams is determined by virtual pair creation. Using a combination of refractive and reflective optics, efficient monochromators for {gamma} beams are being developed. Thus, we have to optimize the total system: the {gamma}-beam facility, the {gamma}-beam optics and {gamma} detectors. We can trade {gamma} intensity for band width, going down to {Delta}E{gamma}/E{gamma} Almost-Equal-To 10{sup -6} and address individual nuclear levels. The term 'nuclear photonics' stresses the importance of nuclear applications. We can address with {gamma}-beams individual nuclear isotopes and not just elements like with X-ray beams. Compared to X rays, {gamma} beams can penetrate much deeper into big samples like radioactive waste barrels, motors or batteries. We can perform tomography and microscopy studies by focusing down to {mu}m resolution using Nuclear Resonance Fluorescence (NRF) for detection with eV resolution and high spatial resolution at the same time. We discuss the dominating M1 and E1 excitations like the scissors mode, two-phonon quadrupole octupole excitations, pygmy dipole excitations or giant dipole excitations under the new facet of applications. We find many new applications in biomedicine, green energy, radioactive waste management or homeland security. Also more brilliant secondary beams of neutrons and positrons can be produced.

43 PARTICLE ACCELERATORS↗

Mechanism of β-FeSi{sub 2} precipitates growth-and-dissolution and pyramidal defects' formation during oxidation of Fe-contaminated silicon wafers

Fe-implanted Si-wafers have been oxidized at 900 °C and 1100 °C in order to investigate the behaviour of Fe atoms at the growing SiO{sub 2}/Si interface and the impact on the integrity of microelectronic devices of an involuntary Fe contamination before or during the oxidation process. As-implanted and oxidized wafers have been characterized using secondary ion mass spectroscopy, atom probe tomography, and high-resolution transmission electron microscopy. Experimental results were compared to calculated implantation profiles and simulated images. Successive steps of iron disilicide precipitation and oxidation were evidenced during the silicon oxidation process. The formation of characteristic pyramidal-shaped defects, at the SiO{sub 2}/Si interface, was notably found to correlate with the presence of β-FeSi{sub 2} precipitates. Taking into account the competitive oxidation of these precipitates and of the surrounding silicon matrix, dynamic mechanisms are proposed to model the observed microstructural evolution of the SiO{sub 2}/Si interface, during the growth of the silicon oxide layer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gamma-jet tomography of high-energy nuclear collisions in NLO pQCD

Within the NLO pQCD partem model study, suppression of away-side hadron spectra associated with a high p{sub T} photon due to parton energy loss is shown to provide more complete tomographic picture of the dense matter formed in high-energy heavy-ion collisions. Hadron spectra at large Z{sub T} P{sub T}{sup h}/p{sub T}{sup {lambda}} > or approx. 1 are more susceptible to parton energy loss and therefore are dominated by surface emission of {lambda}-correlated jets, whereas small Z{sub T} hadrons mainly come from fragmentation of jets with reduced energy which is controlled by the volume emission. These lead to different centrality dependence of the hadron suppression in different region of Z{sub T}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Registration of 3D FMT and CT Images of Mouse via Affine Transformation using Sequential Monte Carlo

It is difficult to directly co-register the 3D FMT (Fluorescence Molecular Tomography) image of a small tumor in a mouse whose maximal diameter is only a few mm with a larger CT image of the entire animal that spans about ten cm. This paper proposes a new method to register 2D flat and 3D CT image first to facilitate the registration between small 3D FMT images and large CT images. A novel algorithm based on SMC (Sequential Monte Carlo) incorporated with least square operation for the registration between the 2D flat and 3D CT images is introduced and validated with simulated images and real images of mice. The visualization of the preliminary alignment of the 3D FMT and CT image through 2D registration shows promising results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Broadband down-conversion based near infrared quantum cutting in Eu{sup 2+}–Yb{sup 3+} co-doped SrAl{sub 2}O{sub 4} for crystalline silicon solar cells

Near infrared (NIR) quantum cutting involving the down conversion of an absorbed visible photon to emission of two NIR photons was achieved in SrAl{sub 2}O{sub 4}:0.01Eu{sup 2+}, xYb{sup 3+} (x=0, 1, 2, 5, 10, 20, 30 mol%) samples. The photoluminescence properties of samples in visible and NIR regions were measured to verify the energy transfer (ET) from Eu{sup 2+} to Yb{sup 3+}. The results demonstrated that Eu{sup 2+} was an efficient sensitizer for Yb{sup 3+} in the SrAl{sub 2}O{sub 4} host lattice. According to Gaussian fitting analysis and temperature-dependent luminescence experiments, the conclusion was drawn that the cooperative energy transfer (CET) process dominated the ET process and the influence of charge transfer state (CTS) of Yb{sup 3+} could be negligible. As a result, the high energy transfer efficiency (ETE) and quantum yield (QY) have been acquired, the maximum value approached 73.68% and 147.36%, respectively. Therefore, this down-conversion material has potential application in crystalline silicon solar cells to improve conversion efficiency. - Graphical abstract: Near infrared quantum cutting was achieved in Eu{sup 2+}–Yb{sup 3+} co-doped SrAl{sub 2}O{sub 4} samples. The cooperative energy transfer process dominated energy transfer process and high energy transfer efficiency was acquired. - Highlights: • The absorption spectrum of Eu{sup 2+} ion is strong in intensity and broad in bandwidth. • The spectra of Eu{sup 2+} in SrAl{sub 2}O{sub 4} lies in the strongest region of solar spectrum. • The cooperative energy transfer (CET) dominated the energy transfer process. • The domination of CET is confirmed by experimental analysis. • SrAl{sub 2}O{sub 4}:Eu{sup 2+},Yb{sup 3+} show high energy transfer efficiency and long lifetime.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tomography of quark gluon plasma at energies available at the BNL Relativistic Heavy Ion Collider (RHIC) and the CERN Large Hadron Collider (LHC)

Using the recently published model [Gossiaux and Aichelin, Phys. Rev. C 78, 014904 (2008)] for the collisional energy loss of heavy quarks in a quark gluon plasma (QGP), based on perturbative QCD (pQCD) with a running coupling constant, we study the interaction between heavy quarks and plasma particles in detail. We discuss correlations between the simultaneously produced c and c quarks, study how central collisions can be experimentally selected, predict observable correlations, and extend our model to the energy domain of the Large Hadron Collider (LHC). We finally compare the predictions of our model with that of other approaches such as anti-de Sitter/conformal field theory (AdS/CFT)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗