Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pv module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Toward a High-Efficient Utilization of Solar Radiation by Quad-Band Solar Spectral Splitting

The promising quad-band solar spectral splitter incorporates the properties of the optical filter and the spectrally selective solar thermal absorber can direct PV band to PV modules and absorb thermal band energy for thermal process with low thermal losses. Finally, it provides a new strategy for spectral splitting and offers potential ways for hybrid PVT system design.

14 SOLAR ENERGY↗

Degradation in photovoltaic encapsulation strength of attachment: Results of the first PVQAT TG5 artificial weathering study

Delamination of the encapsulant in photovoltaic (PV) module technology results in immediate optical loss and may enable subsequent corrosion or mechanical damage. The effects of artificial weathering were not previously known; therefore, an empirical study was performed to survey the factors most affecting adhesion, including the ultraviolet (UV) source (ie, Xe or fluorescent lamp[s]), the optical filters for the lamp, the chamber temperature, and the relative humidity. Natural weathering was also performed at locations, including the following: Golden, Colorado; Miami, Florida; Phoenix, Arizona; QiongHai, China; Riyadh, Saudi Arabia; and Turpan, China. Specimens were constructed using a laminated glass/poly (ethylene-co-vinyl acetate)/glass geometry. The compressive shear test (CST) was used to quantify the mechanical strength of attachment, taken as a proxy for adhesion. The fractography of select specimens (including cross-sectional optical microscopy) was used to verify the failure mode (delamination or decohesion). Additional analysis of the local solar spectrum as well as the specimen temperature was performed to interpret the results of natural weathering. The goals of this study include to identify the most significant stressors, clarify where strong coupling may occur between stressors, and validate accelerated test results relative to natural weathering. The importance of specimen conditioning (for moisture) and hygrometric degradation as well as the effects of UV degradation are identified in this paper.

14 SOLAR ENERGY↗

Experimental investigation on the photovoltaic-thermal solar heat pump air-conditioning system on water-heating mode

An experimental study on operation performance of photovoltaic-thermal solar heat pump air-conditioning system was conducted in this paper. The experimental system of photovoltaic-thermal solar heat pump air-conditioning system was set up. The performance parameters such as the evaporation pressure, the condensation pressure and the coefficient of performance (COP) of heat pump air-conditioning system, the water temperature and receiving heat capacity in water heater, the photovoltaic (PV) module temperature and the photovoltaic efficiency were investigated. The experimental results show that the mean photovoltaic efficiency of photovoltaic-thermal (PV/T) solar heat pump air-conditioning system reaches 10.4%, and can improve 23.8% in comparison with that of the conventional photovoltaic module, the mean COP of heat pump air-conditioning system may attain 2.88 and the water temperature in water heater can increase to 42 C. These results indicate that the photovoltaic-thermal solar heat pump air-conditioning system has better performances and can stably work. (author)

14 SOLAR ENERGY↗

A prototype photovoltaic/thermal system integrated with transpired collector

Building-integrated photovoltaic/thermal (BIPV/T) systems may be utilized to produce useful heat while simultaneously generating electricity from the same building envelope surface. A well known highly efficient collector is the open-loop unglazed transpired collector (UTC) which consists of dark porous cladding through which outdoor air is drawn and heated by absorbed solar radiation. Commercially available photovoltaic systems typically produce electricity with efficiencies up to about 18%. Thus, it is beneficial to obtain much of the normally wasted heat from the systems, possibly by combining UTC with photovoltaics. Combination of BIPV/T and UTC systems for building facades is considered in this paper - specifically, the design of a prototype facade-integrated photovoltaic/thermal system with transpired collector (BIPV/T). A full scale prototype is constructed with 70% of UTC area covered with PV modules specially designed to enhance heat recovery and compared to a UTC of the same area under outdoor sunny conditions with low wind. The orientation of the corrugations in the UTC is horizontal and the black-framed modules are attached so as to facilitate flow into the UTC plenum. While the overall combined thermal efficiency of the UTC is higher than that of the BIPV/T system, the value of the generated energy - assuming that electricity is at least four times more valuable than heat - is between 7% and 17% higher. Also, the electricity is always useful while the heat is usually utilized only in the heating season. The BIPV/T concept is applied to a full scale office building demonstration project in Montreal, Canada. The ratio of photovoltaic area coverage of the UTC may be selected based on the fresh air heating needs of the building, the value of the electricity generated and the available building surfaces. (author)

14 SOLAR ENERGY↗

Wind Conditions for Solar Energy Facility Design Based on Field Measurements at Nevada Solar One

This study characterises near-surface wind conditions at the Nevada Solar One (NSO) concentrated solar power plant using two years of measurements from a 15-m mast located 30 m west of the solar arrays. The surrounding terrain is fairly flat within 3 km, but nearby solar photovoltaic (PV) and concentrated solar power (CSP) installations introduce strong directional wind inhomogeneity, which motivates a sector-based analysis that distinguishes undisturbed inflow from waked flow. The analysis uses data from three sonic anemometers to assess whether turbulence in the surface layer can be represented as Gaussian and whether standard surface-layer scaling remains valid below 10 m height. The roughness length and displacement height are estimated for twelve directional sectors under near-neutral wind conditions, and all three velocity components show departures from Gaussian behaviour. Spectral analysis indicates that the turbulence contains low-frequency fluctuations with amplitudes higher than those predicted by standard models such as the Kaimal model or the Simiu and Scanlan model. The study introduces a new turbulence spectral model based on the eddy-surface-layer framework to better represent near-surface wind turbulence. The analysis further quantifies the influence of the surrounding power plants on mean wind profiles, one-point spectra, and vertical coherence for all velocity components. The solar collector arrays located 30 m east of the mast significantly modify the turbulence structure, whereas PV installations situated a few hundred metres away have only a limited influence on the turbulence measured at the mast. These findings highlight the limitations of conventional turbulence models for near-surface wind over solar infrastructure and provide improved parameterisations to support the structural design. The implications for the structural response of parabolic troughs and PV modules to such turbulence remain uncertain and require further investigation.

14 SOLAR ENERGY↗

Impact of acetic acid exposure on metal contact degradation of different crystalline silicon solar cell technologies

Degradation due to acetic acid in photovoltaic (PV) modules has been a commonly observed phenomenon for both damp-heat exposure and outdoor operations. Acetic acid is a degradation byproduct of ethylene-vinyl acetate (EVA), a common module encapsulant. To address this issue, robust metallization pastes and cell technologies are being developed. However, it is important to assess how these technologies perform in an acetic acid environment and withstand degradation before they are implemented in the solar market. In this work, we investigate the impact of acetic acid exposure on four different cell groups: monofacial passivated emitter and rear contact (PERC) cells with advanced telluride-based front contact pastes, bifacial PERC cells with novel aluminum rear contact pastes, bifacial tunnel oxide passivated contacts (TOPCon) cells, and silicon heterojunction (SHJ) cells. These cells were exposed to acetic acid for different time increments. The recombination losses were characterized by Suns-VOC, and multi-variate regression analysis of intensity-dependent photoluminescence (PL) images with Griddler AI. Resistive losses were tracked with the transmission line method (TLM). Samples showing severe performance degradation were selected for further materials characterization to understand the root cause. Top-down and cross-sectional scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and X-ray photoelectron spectroscopy (XPS) were performed to investigate the change in materials properties. Our study shows that the front contacts of the bifacial TOPCon cells and monofacial PERC cells were significantly affected by acetic acid exposure. Here, the SHJ cells were found to be the most stable.

14 SOLAR ENERGY↗

PV encapsulant formulations and stress test conditions influence dominant degradation mechanisms

Polyethylene-based poly(ethylene-co-vinyl acetate) (EVA), polyolefin elastomer (POE), and thermoplastic polyolefin (TPO) are common polymer candidates for photovoltaic (PV) module encapsulants. The choice of encapsulant must be carefully considered in novel module designs, such as bifacial glass/glass laminates, to limit performance degradation through loss of optical transmittance, mechanical integrity, and corrosion - as well as potential-induced degradation. Encapsulant quality and resilience against environmental stressors are readily influenced by the additives in the encapsulant formulation. Here, we show that, the changes in optical transmittance after UV aging result from the discoloration caused by interactions between additives, and optical scattering from changes in the polymer crystal structure. We observed competing cross-linking and chain scission mechanisms, with their kinetics influenced by the presence of oxygen and elevated temperatures. Increasing chamber temperatures from 55 °C to 85 °C during the UV stress test amplified encapsulant discoloration and promoted polymer cross-linking, causing severe, irreversible damage that remains to be proven field relevant. Damp heat aging was found to be insufficient to produce significant encapsulant degradation; however, combining stress tests sequentially allowed detection of further degradation beyond the limitations of the damp heat test alone. Appropriate degradation screening methods are necessary to uncover potential encapsulant weaknesses.

14 SOLAR ENERGY↗

Towards validation of combined-accelerated stress testing through failure analysis of polyamide-based photovoltaic backsheets

Abstract Novel methods for advancing reliability testing of photovoltaic (PV) modules and materials have recently been developed. Combined-accelerated stress testing (C-AST) is one such method which has demonstrated reliable reproduction of some field-failures which were not reproducible by standard certification tests. To increase confidence and assist in the development of C-AST, and other new testing protocols, it is important to validate that the failure modes observed and mechanisms induced are representative of those observed in the field, and not the product of unrealistic stress conditions. Here we outline a method using appropriate materials characterization and modelling to validate the failure mechanisms induced in C-AST such that we can increase confidence in the test protocol. The method is demonstrated by applying it to a known cracking failure of a specific polyamide (PA)-based backsheet material. We found that the failure of the PA-based backsheet was a result of a combination of stress factors. Photo-oxidation from ultra-violet (UV) radiation exposure caused a reduction in fracture toughness, which ultimately lead to the cracking failure. We show that the chemical and structural changes observed in the backsheet following C-AST aging were also observed in field-aged samples. These results increase confidence that the conditions applied in C-AST are representative of the field and demonstrates our approach to validating the failure mechanisms induced.

14 SOLAR ENERGY↗

Exploring Secondary Markets to Improve Circularity: A Comparative Case Study of Photovoltaics and Hard-Disk Drives

Each year renewable energy generation increases notably with solar panel installations, but these panels have a limited lifespan and will produce between 2 and 4 million metric tons of waste by 2040. Similarly, there are currently between 20 to 70 million hard-disk drives (HDDs) reaching end-of-life (EOL) annually. The circular economy (CE) strives to recycle and reuse materials that are rare and expensive to obtain, minimizing waste. However, studying the potential circularity of photovoltaics (PV) and HDDs requires various data, for instance, on the maturity of the secondhand markets. In this context, the objective of the present study is to identify the current state of secondhand PV and HDD markets. After conducting a literature review, an automated data collection process was set up for that purpose. The analysis of the literature and collected data assess the maturity of the secondhand PV modules and HDDs markets and highlight differences between them.

agent-based modelling↗

Dynamic Braking System of a Tidal Generator

Renewable energy generation has experienced significant cost reductions during the past decades, and it has become more accepted by the global population. In the beginning, wind generation dominated the development and deployment of renewable energy; however, during recent decades, photovoltaic (PV) generation has grown at a very significant pace due to the tremendous decrease in the cost of PV modules. The focus on renewable energy generation has now expanded to include new types with promising future applications, such as river and tidal generation. The input water flow to these types of resources is more predictable than wind or solar generation. The data used in this paper is representative of a typical river or tidal generator. The analysis is based on a generator with a power rating of 40 kW. The tidal generator under consideration is driven by two sets of helical turbines connected to each side of the generator located in between the turbines. The generator is operated in variable speed, and it is controlled to maximize the energy harvested as well as the operation of the turbine generator. The electrical system consists of a three-phase permanent magnet generator connected to a three-phase passive rectifier. The output of the rectifier is connected to a DC-DC converter to match the rectifier output to the DC bus voltage of the DC-AC inverter. The three-phase inverter is connected to the grid, and it is controlled to provide a good interface with the grid. One important aspect of river and tidal generation is the braking mechanism. In a tidal generator, the braking mechanism is important to avoid a runaway condition in case the connection to the grid is lost when there is a fault in the lines. A runaway condition may lead to an overspeed condition and cause extreme stresses on the turbine blade structure and eventual disintegration of the mechanical structure. In this paper, the concept of the dynamic braking system is developed and investigated for normal and abnormal operations. The main objective is to optimize the performance under emergency braking while designing the system to be as simple as possible to avoid overdesigning the power electronics or exceeding the target budget.

13 HYDRO ENERGY↗

A Nonrelational Data Warehouse for the Analysis of Field and Laboratory Data From Multiple Heterogeneous Photovoltaic Test Sites

A nonrelational, distributed computing, data warehouse, and analytics environment (Energy-CRADLE) was developed for the analysis of field and laboratory data from multiple heterogeneous photovoltaic (PV) test sites. This data informatics and analytics infrastructure was designed to process diverse formats of PV performance data and climatic telemetry time-series data collected from a PV outdoor test network, i.e., the Solar Durability and Lifetime Extension global SunFarm network, as well as point-in-time laboratory spectral and image measurements of PV material samples. Using Hadoop/HBase for the distributed data warehouse, Energy-CRADLE does not have a predefined data table schema, which enables ingestion of data in diverse and changing formats. For easy data ingestion and data retrieval, Energy-CRADLE utilizes Hadoop streaming to enable Python MapReduce and provides a graphical user interface, i.e., py-CRADLE. By developing the Hadoop distributed computing platform and the HBase NoSQL database schema for solar energy, Energy-CRADLE exemplifies an integrated, scalable, secure, and user-friendly data informatics and analytics system for PV researchers. Furthermore, an example of Energy-CRADLE enabled scalable, data-driven, analytics is presented, where machine learning is used for anomaly detection across 2.2 million real-world current-voltage (I–V) curves of PV modules in three distinct Koppen–Geiger climatic zones.

14 SOLAR ENERGY↗

Sputter-Deposited Oxides for Interface Passivation of CdTe Photovoltaics

Commercial CdTe PV modules have polycrystalline thin films deposited on glass, and devices made in this format have exceeded 22% efficiency. Devices made by the authors with a magnesium zinc oxide window layer and tellurium back contact have achieved efficiency over 18%, but these cells still suffer from an open-circuit voltage far below ideal values. Oxide passivation layers made by sputter deposition have the potential to increase voltage by reducing interface recombination. CdTe devices with these passivation layers were studied with photoluminescence (PL) emission spectroscopy and time-resolved photoluminescence (TRPL) to detect an increase in minority carrier lifetime. Because these oxide materials exhibit barriers to carrier collection, micropatterning was used to expose small point contacts while still allowing interface passivation. TRPL decay lifetimes have been greatly enhanced for thin polycrystalline absorber films with interface passivation. Device performance was measured and current collection was mapped spatially by light-beam-induced current.

14 SOLAR ENERGY↗

Millions of Small Pressure Cycles Drive Damage in Cracked Solar Cells

Here, we applied time-varying air pressure to a PV module containing newly cracked cells. The test used a new dynamic mechanical acceleration (DMX) apparatus. We applied pressure cycles similar to natural, wind-driven cycles. Compared to standard dynamic mechanical load (DML) tests, we applied much lower pressure (10 Pa to 300 Pa RMS) and many more cycles (one million at each of four pressure levels). We present a case study on a single cell in a commercial module. We monitored electrical continuity loss across cracks using electroluminescence (EL) imaging. 10 Pa pressure cycles caused negligible change. 30 Pa pressure cycles caused permanent damage that continued worsening even after tens of thousands of cycles. After one million 30 Pa cycles, a series of 100 Pa cycles still caused new, permanent damage to existing cracks. 300 Pa cycles caused further worsening and introduced new cracks.

14 SOLAR ENERGY↗

Nanometer-Scale Measurement of Grid Finger Electrical Conduction Pathways to Detect Series Resistance Degradation of Utility-Scale Silicon Solar Cells

Here, we report on an electrical conduction mechanism for series resistance (Rs) degradation observed in a utility-scale photovoltaic power plant by imaging the local resistance at the Ag/Si interface of the c-Si front metallization. Scanning spreading resistance microscopy imaging with nanometer (nm) scale spatial resolution revealed that the number of point or small-area electrical contacts decreased substantially in a degraded cell compared to an unaffected cell, demonstrating the root cause of Rs degradation. The decrease in electrical contacts is likely caused by a structural change - the Ag particles in contact with the Si cell (or via a nm-thickness tunneling glass layer) aggregate into bulk Ag, and a highly resistive glass frit forms a belt shape at the Ag/Si interface. This resistive belt, with a thickness of ~1 um, blocks the current conduction from the cell emitter to the Ag grid. Our microscopy results help to unravel unambiguously the degradation mechanism and demonstrate an example of the multiscale characterization approach for understanding degradation in field-weathered PV module.

14 SOLAR ENERGY↗

Impact of Floating PV (FPV) System on Water Evaporation: Case Study of an Open Loop Reservoir in North Carolina

Fresh water scarcity is becoming one of the important concerns worldwide. This situation of water scarcity is further exacerbated by the increase in water evaporation due to climate change. This manuscript will address this concern by considering the impact of floating photovoltaics (FPVs) systems on water evaporation. The installation of PV modules on the water bodies can help reduce the water evaporation rate from reservoirs by reducing the evaporating area of the water surface. This work evaluates the effect of FPV on water evaporation rates in the TuckerTown reservoir located in North Carolina state of United States. Meteorological data, such as mean temperature and dew-point, are used to calculate the rate of the water evaporation by Linacre method. The simulation results for the TuckerTown case study showed that the aggregated avoided evaporated volume for one year is 9 million gallons.

14 SOLAR ENERGY↗

DC Arc Incident Energy in Photovoltaic Systems: Methods for Evaluation

Renewable energy systems continue to be one of the fastest growing segments of the energy industry. This article focuses on the understanding of how photovoltaic (PV) technology behaves under dc arc conditions. Emphasis is placed on the electrical safety aspect of dc arc-flash incident energy (IE) evaluation. Because of the fast proliferation of PV systems and lack of formal equivalent calculation guidelines, such as IEEE 1584 for ac systems, it has been necessary to rely on different equations and models presented by various researchers over the last few years. This article discusses the behavior of PV systems under arc conditions and presents the results of the available methods to estimate the dc arc-flash IE. It provides a comparative analysis of a proposed arc-flash IE calculation method against different laboratory tests, including those performed for this article at the National Renewable Energy Laboratory (NREL). Detailed explanations are provided regarding the effect of the PV module current-voltage (I-V) and power-voltage (P-V) curves under arcing conditions. Examples of the application of the proposed calculation method to the test measurements are included.

arc discharges↗

PV inverter performance and reliability: What is the role of the bus capacitor?

In order to elucidate how the degradation of individual components affects the state of the photovoltaic inverter as a whole, we have carried out SPICE simulations to investigate the voltage and current ripple on the DC bus. The bus capacitor is generally considered to be among the least reliable components of the system, so we have simulated how the degradation of bus capacitors affects the AC ripple at the terminals of the PV module. Degradation-induced ripple leads to an increased degradation rate in a positive feedback cycle. Additionally, laboratory experiments are being carried out to ascertain the reliability of metallized thin film capacitors. By understanding the degradation mechanisms and their effects on the inverter as a system, steps can be made to more effectively replace marginal components with more reliable ones, increasing the lifetime and efficiency of the inverter and decreasing its cost per watt towards the US Department of Energy goals.

14 SOLAR ENERGY↗

Development and First Results of the Width-Tapered Beam Method for Adhesion Testing of Photovoltaic Material Systems

A fracture mechanics based approach for quantifying adhesion at every interface within the PV module laminate is presented. The common requirements of monitoring crack length and specimen compliance are circumvented through development of a width-tapered cantilever beam method. This technique may be applied at both the module and coupon level to yield a similar, quantitative, measurement. Details of module and sample preparation are described and first results on field-exposed modules deployed for over 27 years presented.

14 SOLAR ENERGY↗