Development and Validation of Two-Phase Flow Models in MOOSE and Application to Molten Salt Reactors

Two-phase flow in Molten Salt Reactors (MSRs) is important as it impacts reactivity evolution, reactor transient response, and the removal of species dissolved in the molten salt through gas phase transfer. Therefore, accurately predicting the gas distribution and the associated liquid-gas interface area in MSRs is essential for their design and operation. Recently, we integrated a new two-phase model into Idaho National Laboratory (INL)’s Multiphysics Object-Oriented Simulation Environment (MOOSE): a multi-D generalization of a mixture drift-flux model. It provides greater computational efficiency, which is typically preferred for modeling reactor transients. However, the mixture model’s accuracy in capturing void distribution and interfacial area in MSRs still needs to be assessed. This article begins with a description of the mathematical framework for the two-phase model implemented in MOOSE. It then presents validation of these models against relevant experimental data. Finally, the model is applied to the Molten Salt Reactor Experiment case study, analyzing various operational conditions such as different rates of fission product volatilization and diverse cover gas entrainment scenarios at the reactor pump. The article concludes by assessing the suitability of the mixture drift-flux model for capturing the two-phase flow dynamics critical to MSR operations

42 - ENGINEERING↗

Development and Validation of Two-Phase Flow Models in MOOSE for Molten Salt Reactor Application

Two-phase flow in Molten Salt Reactors (MSRs) is important as it impacts reactivity evolution, reactor transient response, and the removal of species dissolved in the molten salt through gas phase transfer. Therefore, accurately predicting the gas distribution and the associated liquid-gas interface area in MSRs is essential for their design and operation. Recently, we integrated two new models into Idaho National Laboratory (INL)’s Multiphysics Object-Oriented Simulation Environment (MOOSE): a multi-D generalization of a mixture drift-flux model and a Euler-Euler model. The Euler-Euler model offers higher fidelity, while the mixture drift-flux model provides greater computational efficiency, which is typically preferred for modeling reactor transients. However, the mixture model's accuracy in capturing void distribution and interfacial area in MSRs still needs to be assessed. This article begins with a description of the mathematical framework for the two-phase models implemented in MOOSE. It then presents validation of these models against relevant experimental data. Finally, both models are applied to the Molten Salt Reactor Experiment case study, analyzing various operational conditions such as different rates of fission product volatilization and diverse cover gas entrainment scenarios at the reactor pump. The article concludes by assessing the suitability of both models for capturing the two-phase flow dynamics critical to MSR operations.

42 - ENGINEERING↗

Development and Validation of Two-Phase Flow Models in MOOSE and Application to Molten Salt Reactors

Two-phase flow in Molten Salt Reactors (MSRs) is important as it impacts reactivity evolution, reactor transient response, and the removal of species dissolved in the molten salt through gas phase transfer. Therefore, accurately predicting the gas distribution and the associated liquid-gas interface area in MSRs is essential for their design and operation. Recently, we integrated two new models into Idaho National Laboratory (INL)’s Multiphysics Object-Oriented Simulation Environment (MOOSE): a multi-D generalization of a mixture drift-flux model and a Euler-Euler model. The Euler-Euler model offers higher fidelity, while the mixture drift-flux model provides greater computational efficiency, which is typically preferred for modeling reactor transients. However, the mixture model's accuracy in capturing void distribution and interfacial area in MSRs still needs to be assessed. This article begins with a description of the mathematical framework for the two-phase models implemented in MOOSE. It then presents validation of these models against relevant experimental data. Finally, both models are applied to the Molten Salt Reactor Experiment case study, analyzing various operational conditions such as different rates of fission product volatilization and diverse cover gas entrainment scenarios at the reactor pump. The article concludes by assessing the suitability of both models for capturing the two-phase flow dynamics critical to MSR operations.

42 - ENGINEERING↗

First Ever Polymer Flood Field Pilot To Enhance The Recovery Of Heavy Oils On Alaska’s North Slope - Pushing Ahead One Year Later

In June 2018 the team embarked on an ambitious project to address the slow development pace of Alaska’s 20+ billion barrels heavy oil resource via the first ever polymer flood pilot. Following the successful commencement of the pilot in August 2018, the field demonstration, supporting laboratory experiments and numerical simulation have steadily progressed. A significant amount of valuable data and lessons learned have been collected, and are reported in this paper. The ongoing pilot and the research activities is making headway toward the primary objective of validating the use of polymer flooding for extracting heavy oil in Alaska’s challenging environment. The pilot is conducted in two pre-existing pairs of horizontal injectors and producers in an isolated fault block of the Schrader Bluff heavy oil reservoir at the Milne Point Field. A customized polymer blending and pumping unit injects HPAM polymer at a concentration of 1,750 ppm to achieve a target viscosity of 45 cP. Supporting coreflood laboratory experiments have focused on quantification of polymer retention in the rock, and effect of injection water salinity, polymer, and their combinations on oil recovery. The injection and production response of the pilot flood pattern is utilized to develop a history matched reservoir simulation model for forecasting oil recovery beyond the pilot. Finally, specially designed laboratory experiments address anticipated operating concerns regarding post-polymer breakthrough such as oil-water separation efficiency and polymer induced fouling of heater tubes. Polymer has been injected continuously since startup except for two short equipment modification shutdowns, and more recently a prolonged disruption due to polymer hydration issues at the J-pad field site. Cumulatively, over 600,000 lbs. of polymer has been injected, corresponding to ~7%PV. The two producers show significant decrease in the water cut, gradually increasing oil rate, and no polymer breakthrough. Two main observations from the coreflood are a significant uncertainty in polymer retention values, and positive oil recovery response to low salinity water (2,600 mg/liter TDS). The heterogeneity in the flood pattern presents some challenges in obtaining a robust history matched simulation model. Experimental results on produced fluids treatment indicate the formation of a dense polymer deposit, at certain conditions, on heating tubes that can negatively impact the heat transfer efficiency. The scientific knowledge, including the lessons learned during unanticipated shutdowns, quality control, logistics and field data that is being acquired from this effort has referential value for other planned EOR projects. Finally, by all indications, the polymer field pilot is steadily progressing toward achieving the ultimate goal of unlocking the massive heavy oil resources on Alaska North Slope (ANS).

Dandekar, Abhijit↗

Mutations in the proximal binding site and F-loop of AdeJ confer resistance to efflux pump inhibitors

Multidrug efflux is one of the major mechanisms of antibiotic resistance in gram-negative bacteria. Inhibitors of efflux pumps potentiate the activities of antibiotics, and their discovery could lead to new therapeutic options. The AdeIJK pump in Acinetobacter baumannii is a promising target for efflux pump inhibitors (EPIs) due to its high clinical importance and conservation, and several classes of EPIs targeting this and other A. baumannii efflux transporters have been recently reported. However, the mechanisms of action of these EPIs and their resistance liability remain underexplored. Here, we analyzed the impact of site-specific substitutions in the substrate/EPI translocation path of the inner membrane transporter AdeJ on efflux of substrate antibiotics and fluorescent probes and activities of substituted 4,6-diaminoquinoline EPIs. We found that substitutions in amino acid residues located in the entrance cleft (R701) and the flexible loop (E675) of AdeJ lead to resistance specifically against biphenyl-substituted EPIs, whereas the substitution of F178 in the distal binding pocket increased AdeJ sensitivity to certain naphthyl- and biphenyl-substituted EPIs. No major differences in docking scores and poses of substrates and EPIs were observed between the wild type and corresponding AdeJ variants for any of the mutations considered. This study concludes that substrates and EPIs bound along the translocation path of AdeJ participate in its conformational transitions and can either increase or decrease the rate of transport and therefore the efficiency of EPIs.

Acinetobacter↗

Janus Monolayers for Ultrafast and Directional Charge Transfer in Transition Metal Dichalcogenide Heterostructures

Charge transfer properties of van der Waals heterostructures formed by Janus and regular transition metal dichalcogenide monolayers are studied by time-resolved pump–probe measurements and photoluminescence spectroscopy. Measurements of electron and hole transfer in three heterostructures with atomic layer sequences of S–W–Se/S–W–S, Se–W–S/S–W–S, and S–W–Se/Se–W–Se reveal that charge transfer from regular to Janus monolayers is ultrafast regardless of the direction of the built-in electric field of the Janus monolayer (Janus field). However, the charge transfer from Janus to regular layers is directional and controlled by the Janus field. When the current direction is along the field, the charge transfer is ultrafast and efficient, while the field blocks the charge transfer with an opposite charge current direction. The transferred carriers form interlayer excitons with extended lifetimes compared to the intralayer excitons. The demonstrated ultrafast and directional charge transfer between Janus and regular TMD layers shows that the Janus structures can be used to make 2D heterostructures with efficient and directional charge transfer properties.

36 MATERIALS SCIENCE↗

Carbon‐Neutral Pathways for the United States

Abstract The Intergovernmental Panel on Climate Change (IPCC) Special Report on Global Warming of 1.5°C points to the need for carbon neutrality by mid‐century. Achieving this in the United States in only 30 years will be challenging, and practical pathways detailing the technologies, infrastructure, costs, and tradeoffs involved are needed. Modeling the entire U.S. energy and industrial system with new analysis tools that capture synergies not represented in sector‐specific or integrated assessment models, we created multiple pathways to net zero and net negative CO 2 emissions by 2050. They met all forecast U.S. energy needs at a net cost of 0.2–1.2% of GDP in 2050, using only commercial or near‐commercial technologies, and requiring no early retirement of existing infrastructure. Pathways with constraints on consumer behavior, land use, biomass use, and technology choices (e.g., no nuclear) met the target but at higher cost. All pathways employed four basic strategies: energy efficiency, decarbonized electricity, electrification, and carbon capture. Least‐cost pathways were based on >80% wind and solar electricity plus thermal generation for reliability. A 100% renewable primary energy system was feasible but had higher cost and land use. We found multiple feasible options for supplying low‐carbon fuels for non‐electrifiable end uses in industry, freight, and aviation, which were not required in bulk until after 2035. In the next decade, the actions required in all pathways were similar: expand renewable capacity 3.5 fold, retire coal, maintain existing gas generating capacity, and increase electric vehicle and heat pump sales to >50% of market share. This study provides a playbook for carbon neutrality policy with concrete near‐term priorities.

Williams, James H.↗

A recirculation system for concentrating CO 2 electrolyzer products

Electrochemical carbon dioxide reduction represents a promising path to utilize CO 2 as a feedstock for generating valuable products such as fuels and chemicals. Faradaic efficiencies near 100% have been achieved for certain CO 2 reduction products such as CO, but the electrolyzer outlet streams usually contain large fractions of unreacted CO 2 , dropping the product concentrations below 1% in many cases. The system disclosed here recycles the unreacted CO 2 together with the products and flows them back into the CO 2 reduction reactor, enabling much higher CO 2 conversion rates without dropping the gas flow rate. However, simple recirculation is shown to accumulate significant amounts of hydrogen, impeding effective CO 2 reduction. In this looped system, an electrochemical H 2 pump is placed in series with the CO 2 reactor, which effectively removes all the H 2 from the recycled gas stream, increasing the concentrations of carbon-containing products. Here, the system was initially tested with a CO-generating catalyst and CO concentrations above 70% were achieved in the recycled gas stream, compared to a maximum CO concentration of 8% in single-pass configuration. Results with a CO 2 reactor targeting ethylene as the main product show that ethylene concentrations of at least 10% can be achieved, which is roughly 20 times higher compared to a single-pass system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparison of plug flow and multi-node stratified tank modeling approaches regarding computational efficiency and accuracy

Residential water heaters contain water stratified by temperature-driven density differences. This implies that a water tank can reach a state in which the top and bottom sections have different temperatures, unless mixing happens. A high degree of thermal stratification can improve the efficiency of some water heaters, by saving the amount of energy required for the heat-up process. Studies of stratification became popular in the 1970s and it remains an active research topic today. The research has led to the development of different models and techniques to better predict and define a stratified tanks behavior. By comparing these models and techniques used previously to describe thermal stratification, the phenomenon could be better understood, exploited, and used to increase efficiency and thermal energy capacity in modern water tanks. From the existing models, we found the one-dimensional standard plug-flow and a multi node model to be appropriate for analyzing the processes of the heat up and cool-down in a water tank. These two models are based on energy balances. This work involved comparing the accuracy and computational effort needed to implement these models. To assess accuracy, we compared both types of existing models to experimental data (also collected in this work) which included a heat up process using an external heat pump. This external process included a layering process that has an eddy diffusivity at five times the rate of thermal diffusion. For this project, we implemented the models in MATLAB, the multi-paradigm numerical computing environment. We quantified model accuracy using the root mean squared error between modeled data and experimental data for six measured tank temperatures. Comparing the accuracy and the computational time taken to run the simulation provides a method to contrast the performance of each model and a way to rate it. The multi node model was run using from 6 to 96 spatial nodes; the plug flow model was run using 1 to 0.001 º C temperature bin sizes. Additionally, timesteps were varied from 4 to 236 s. The results quantify the tradeoff between accuracy and computational time, providing guidance for simulations to intelligently select the best model type and simulation parameters. This research can be used to validate the pre-existing models and possibly improve the modern water tank.

Bulnes, Fernando Karg↗

Coherent Transfer of Lattice Entropy via Extreme Nonlinear Phononics in Metal Halide Perovskites

Entropy transfer in metal halide perovskites, characterized by significant lattice anharmonicity and low stiffness, underlies the remarkable properties observed in their optoelectronic applications, ranging from solar cells to lasers. The conventional view of this transfer involves stochastic processes occurring within a thermal bath of phonons, where the lattice arrangement and energy flow from higher- to lower-frequency modes. Here, we unveil a comprehensive chronological sequence detailing a conceptually distinct coherent transfer of entropy in a prototypical perovskite CH 3 NH 3 Pbl 3 . The terahertz periodic modulation imposes vibrational coherence into electronic states, leading to the emergence of mixed (vibronic) quantum beat between approximately 3 and 0.3 THz. We highlight a well-structured bidirectional time-frequency transfer of these diverse phonon modes, each developing at different times and transitioning from high to low frequencies from 3 to 0.3 THz, before reversing direction and ascending to around 0.8 THz. First-principles molecular dynamics simulations disentangle a complex web of coherent-phononic coupling pathways and identify the salient roles of the initial modes in shaping entropy evolution at later stages. Capitalizing on coherent entropy transfer and dynamic anharmonicity presents a compelling opportunity to exceed the fundamental thermodynamic (Shockley-Queisser) limit of photoconversion efficiency and to pioneer novel optoelectronic functionalities. Published by the American Physical Society 2024

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

DOE Cold Climate Heat Pump Challenge Field Validation: Data Collection and Analysis Plan

This document details the data collection, storage, and analysis plan and methodologies for conducting the field validation portion of DOE’s Cold Climate Heat Pump (CCHP) Challenge. The study is focused on validating the in-field heating performance of prototypical CCHPs that have successfully demonstrated that they meet or exceed the Challenge specification in a laboratory setting. The units that have passed laboratory testing will be installed in real homes along with sensors and loggers for monitoring performance over an entire heating season. Data collected through monitoring will be cleaned and stored in a secure database. The data will be analyzed for calculating the key metrics defined by the Challenge including heating capacities at low outdoor air temperatures (below 32 °F), efficiency in terms of the Coefficient of Performance (COP), switchover temperatures and auxiliary heat staging. Demand Response (DR) capabilities will also be tested using specially designed DR events. In most cases, shoulder season and cooling season performance will also be determined and reported.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of a High-Pressure Fuel System for Use with Dimethyl Ether

The paper documents the modeling and experimental work on a common rail fuel injection system for Dimethyl Ether, a potential diesel substitute with a low carbon intensity signature. The DME fuel system is deployed on a light duty 2.2L compression ignition engine. The paper describes the injector optimization to shift to higher flows to account for the lower heating value and density of the DME when compared to diesel. The type of the injection system used for the DME application is an advanced rendering of the Common rail noted for a one-piece piston-needle injector construction and a solenoid driven spill valve featuring a pressure balanced poppet. A dedicated high-pressure fuel pump designed to pressurize DME is used. The design results in a fast acting open and close injection event, reduced leakage, with reduced cavitation in the fuel injector volume. Design parameters for system optimization included fill and spill orifices, needle lift, bias spring, and injector hole size. The design model provides good correlation of the instantaneous rates of injection with experiments across a wide range of pressure and injection timings. Proposed performance milestones for the design included similar DME injection duration to the diesel counterpart for same fuel energy injected into the cylinder to retain high engine cycle efficiency. Here, the dedicated DME design provided reduced hydraulic delays of 50%. Tests demonstrated sustained operation at pressures of 1000 bar, with capability to reach 1500bar. Durability tests showed no cavitation-deterioration over a 200-hour test cycle by means of spray imaging and hardware inspection.

De Ojeda, William [WM International Engineering, L↗

Electron Heating in the Transrelativistic Perpendicular Shocks of Tilted Accretion Flows

Abstract General relativistic magnetohydrodynamic (GRMHD) simulations of black hole tilted disks—where the angular momentum of the accretion flow at large distances is misaligned with respect to the black hole spin—commonly display standing shocks within a few to tens of gravitational radii from the black hole. In GRMHD simulations of geometrically thick, optically thin accretion flows, applicable to low-luminosity sources like Sgr A* and M87*, the shocks have transrelativistic speed, moderate plasma beta (the ratio of ion thermal pressure to magnetic pressure is β pi1 ∼ 1–8), and low sonic Mach number (the ratio of shock speed to sound speed is M s ∼ 1–6). We study such shocks with 2D particle-in-cell simulations, and we quantify the efficiency and mechanisms of electron heating for the special case of preshock magnetic fields perpendicular to the shock direction of propagation. We find that the postshock electron temperature T e2 exceeds the adiabatic expectation T e2,ad by an amount T e 2 / T e 2 , ad − 1 ≃ 0.0016 M s 3.6 , nearly independent of the plasma beta and of the preshock electron-to-ion temperature ratio T e1 / T i1 , which we vary from 0.1 to unity. We investigate the heating physics for M s ∼ 5–6 and find that electron superadiabatic heating is governed by magnetic pumping at T e1 / T i1 = 1, whereas heating by B -parallel electric fields (i.e., parallel to the local magnetic field) dominates at T e1 / T i1 = 0.1. Our results provide physically motivated subgrid prescriptions for electron heating at the collisionless shocks seen in GRMHD simulations of black hole accretion flows.

Astronomy & Astrophysics↗

Estimating the Impacts of Increasing Temperatures and the Efficacy of Climate Adaptation Strategies in Urban Microclimates with Deep Learning

As urbanization and climate change progress, understanding and addressing urban heat becomes a priority for climate adaptation efforts. High temperatures concentrated in the urban core can drive increased risk of heat-related death and illness as well as increased energy demand for cooling. However, modeling the urban microclimate is an ongoing field of research typically burdened by an imprecise description of the built environment, incomplete observational records, significant computational cost, and a lack of high-resolution estimates of the impacts of increasing temperatures. Here, we present computationally efficient machine learning methods that can improve the accuracy of urban temperature estimates when compared to historical reanalysis data. These models are applied to a neighborhood in Los Angeles, and we compare the energy benefits of heat mitigation strategies to the impacts of climate change. We find that cooling demand is likely to increase substantially through midcentury, but engineered high-albedo surfaces could lessen this increase by more than 50 %. The corresponding increase in winter gas heating offsets the summer cooling benefit in the current climate, but total annual energy use from combined heating and cooling with electric heat pumps benefits from the engineered heat mitigation strategies under both current and future climates.

54 ENVIRONMENTAL SCIENCES↗

HERO WEC V1.0 2024 - WEC-Sim Detailed Simulation Runs and Summary Data

This dataset includes results from simulations of NREL's hydraulic and electric reverse osmosis wave energy converter (HEREO WEC). Simulation runs include 135 wave cases that were based on the updated WEC-Sim model, which is linked below. The data represented in this repository is based on an updated WEC-Sim model using laboratory data to tune and refine the original WEC-Sim model for the V1.0 HERO WEC. The 135 wave cases represent waves with the following wave height and wave period ranges: - Significant Wave Height: 0.25 - 3.75m in 0.25m increments - Wave Period: 5 - 13 sec in 1 sec increments Each run was simulated using a Pierson-Moskowitz irregular wave spectrum with a 100 second ramp time, a total simulation time of 3,100 seconds, and a simulation time-step of 0.005s. A reference table has been included to map each multi condition run (MCR) case with each wave condition. Summary data set includes a spreadsheet and image files with matrices that are associated with data from simulation runs. All matrices cover the same significant wave height and wave periods from the simulation runs, in the same increments. The following matrices are included: - Power Abs: The average absorbed power from the WEC (calculated from anchor reaction force and heave velocity) - Power Hyd: The average hydraulic power output at pump (calculated from pump output flow and pressure) - Power - Hyd ROi: The average hydraulic power measured at the RO system inlet (calculated from RO system pressure and flow (pre-accumulator)) - Flow - Pump out: The average flowrate measured at the pump outlet - Flow - Perm: The average permeate (clean water) production - Flow - RO (pre): The average flowrate measured at the inlet of the RO system before the accumulators - Flow - RO (post): The average flowrate measured after the accumulator bank in the RO system - Pressure - RO: The average pressure measured at the inlet of the RO system This data set has been developed by the National Renewable Energy Laboratory, operated by the Alliance for Sustainable Energy, LLC, for the U.S. Department of Energy (DOE) under Contract No. DE-AC36-08GO28308. Funding provided by the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Water Power Technologies Office.

16 TIDAL AND WAVE POWER↗

Effects of trapped charge on the signal formation and detection efficiency for subsequent pulses in irradiated silicon sensors

Envisaged high energy physics experiments like the Future Circular Collider require unprecedented radiation hardness of the detectors, as well as short readout time due to high luminosity and occupancy. Silicon has proven to be extremely radiation hard. Sufficient signals can be recorded even at fluences close to 1 ∙ 1 0 16 n e q / cm 2 . Here, the signal formation was studied in silicon strip sensors, irradiated and annealed until the phenomenon of charge multiplication occurred. ATLAS12EC R0 mini sensors were tested by means of edge TCT measurements at temperatures around –20 °C. It was observed that the detection of subsequent signals separated up to several microseconds is altered by the charge trapped during the preceding pulses. The effects of trapped charge on the electrical configuration of a sensor are well known as a polarization or pumping effect in larger band-gap materials like diamond, but is often neglected for silicon at this relatively high temperature. The investigation of the effect created by trapped charges in silicon sensors using subsequent pulses allows to gain information on important parameters such as de-trapping times. Furthermore, it shows a severe impact on the sensor performance in a pile-up scenario. The irradiation fluence and hence the effective doping concentration, the temperature and the amount of initially created charge have a large impact on this phenomenon. The measurements presented help to characterize this phenomenon; particular attention was paid to the application point of view.

47 OTHER INSTRUMENTATION↗

The value of integrating a geothermal district heating system into a microgrid

As electrical grids increasingly rely on variable renewable energy, maintaining reliability and cost efficiency becomes more complex. To address these challenges, this study analyzed the integration of geothermal district heating as a grid-responsive thermal resource within a microgrid in Tuttle, Oklahoma. Building energy modeling using EnergyPlus estimated annual district heating demand at 2.9 GWh, with a peak load of 2.8 MW th . Techno-economic analyses were conducted to meet the heating demand under three geothermal scenarios, varying by production depth, flow rate, and thermal output, each supplemented by natural gas peaking boilers. In parallel, equivalent electrical load profiles were developed using typical coefficients of performance (COPs) for air-source heat pumps and electric boilers to establish an electrified baseline scenario. A complete end-use electrical load profile was also developed for the microgrid using Cambium dataset. The modeling results demonstrated reliable and economic operation of the geothermal systems over 30 years, with COPs ranging from 2.6 to 8.9 and the lowest levelized heating cost at $\$$54.6/MWh. Geothermal integration reduced electricity consumption by up to 94.7 % compared to the non-geothermal base case, yielding annual energy savings of up to $\$$803 k. Avoided grid costs ranged from $\$$65 k–$\$$147 k per year, with individual events avoiding up to $\$$4,863 per hour. Grid-responsive operation further reduced wholesale energy costs by 53–56 %. These findings demonstrate geothermal heating, traditionally treated as a non-grid-responsive thermal resource, can be reconfigured to support dynamic grid services, offering a scalable pathway to enhance reliability and reduce costs in renewable-rich microgrids and district heating networks.

15 GEOTHERMAL ENERGY↗

Cataloging Legacy Data from the Tritium Systems Test Assembly Program

The Tritium Systems Test Assembly (TSTA) at Los Alamos National Laboratory, operational from 1984 to 2001, was critical in advancing fusion fuel cycle technologies, including tritium storage, gas separation, and pumping. TSTA’s contributions, particularly in safe tritium operations, have influenced subsequent fusion projects. This paper discusses the ongoing effort to digitize and catalog TSTA’s historical data to create a searchable resource for the fusion research community. While the long-term objective is to develop a relational database for structured data management, the project remains in the early phase, with current efforts focused on scanning and indexing physical documents. Initial plans for database implementations are also presented, outlining key considerations for structure, query indexing, and standardization. As digitization progresses, future discussions will refine these implantation details to ensure an efficient and comprehensive system. This initiative aims to preserve critical legacy data, enhance the design of tritium system facilities, and support the next generation of fusion energy research.

42 ENGINEERING↗