Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system parameter estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Developing Flexible, Networked Lighting Control Systems That Reliably Save Energy in California Buildings

An important strategy to meet California's ambitious energy efficiency goals is to use innovative wireless communications, embedded sensors, data analytics and controls to significantly reduce lighting energy use in commercial buildings. This project developed a suite of networked lighting solutions to further this goal. The technologies include a platform for low-cost sensing, distributed intelligence and communications, the “PermaMote,” which is a self-powered sensor and controller for lighting applications. The project team also developed a task ambient daylighting system that integrates sensors with data-driven daylighting control using an open communication interface, called the “Readings-At-Desk” (RAD) system. To address the problem of building occupants being confused about how to operate traditional lighting control systems, the research team created content that could be the basis for a user interface standard for lighting controls. Finally, to address the difficulty of ensuring that advanced lighting control systems actually deliver their promised energy savings, the project team developed a new method for evaluating and specifying lighting systems’ performance. The research team validated these technologies in the laboratory, showing significant lighting energy savings, up to 73% for the PermaMote sensor system from occupancy control and daylight dimming features, compared to the same light source (LED replacement lamps) operated via simple on/off scheduling. The project team also developed a proposed standard lighting data model and user interface elements, which were contributed to the ANSI Lighting Systems Committee (C137) for standardization. Existing data models are incomplete and inconsistent, whereas the lighting-specific data model developed here is clear and comprehensive, to serve as a starting point for creating common, universally agreed upon semantic definitions of key lighting parameters, to promote interoperability. For the task on verifiable performance of lighting systems, the project team developed a more effective metric for capturing the actual energy impact of a lighting system over time — the energy usage intensity (kWh/ft2/year). Three commercial lighting systems were tested in FLEXLAB® using this new metric, and the tests show a wide range in the accuracy of the self-reported energy-use metric, from 0.5% to 28% error compared to direct measurement of lighting energy using dedicated submeters. Overall, the project team estimates that these advanced technologies can reduce California office lighting energy use by 20% (above and beyond normal advanced lighting controls mandated by Title 24), resulting in about 1,600 GWh/year in savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Integrated Supercritical System for Efficient Produced Water Treatment and Power Generation

The main goal of this project was to evaluate the feasibility of an integrated supercritical (SC) water desalination and power generation system for treatment of produced waters from CO 2 sequestration, oil production, and coal-bed methane recovery. This system may offer a transformative approach to generating power from coal or natural gas (NG) and purifying saline water or produced water with high total dissolved solids (TDS) in a zero-liquid discharge plant. The closed-loop steam cycle of conventional power plants was replaced with an open-loop steam cycle that heated the pretreated produced water above the SC point of water (374 °C and 221 bar) to precipitate and separate the salts dissolved in the water. After separation of the precipitated salt, the SC steam required further treatment to reduce the salt content from ~100 mg/L (ppm) to <1 ppm to make it suitable for use in turbines for power generation. A SC membrane distillation unit was used to polish the SC steam, which could be sent through a series of turbines for power generation, and the steam exiting the low-pressure turbine could be condensed by cooling water to produce pure water. Project tasks included a process simulation and a techno-economic evaluation of the integrated system; design and assembly of SC salt precipitation and membrane distillation systems; development and characterization of advanced carbon membranes for SC membrane distillation; and pretreatment, desalination, and purification of different produced water samples with salt concentrations of 30,000–200,000 ppm to a high-purity (<1 ppm) level. Process simulations were performed for 550 MW SC coal-fired or NG baseline cases and various scenarios for the proposed integrated SC system using produced water as the water source and coal or NG as the fuel source. Simulation results indicated that the net plant efficiency loss of the proposed SC cogeneration process would be in the range of <1% to ~4%, in which NG and lower TDS produced water cases would have higher efficiencies. The proposed process for coal-fired cases could provide all water needs for the power generation process and generate additional pure water for beneficial use. A techno-economic analysis was performed to estimate the cost of produced water treatment (dollars /kgal of treated water) by conventional treatment processes compared with the proposed cogeneration process. The cost estimation for the proposed cogeneration system included the cost of pretreatment, the cost of power loss to integrate the water desalination process into the power generation system, and the cost of plant modification or retrofitting. The cost of produced water treatment was calculated by assuming three different scenarios in which converting a baseline power plant to the proposed cogeneration plant would increase the cost of the boiler and feed water system by 10%, 50%, and 100%. Results indicated that the cost of produced water treatment, even with a 100% cost increase, was in the range of $8.6–11.6 dollars per kgal, which is about half of the treatment cost by conventional methods. The cost of produced water treatment by the proposed cogeneration system could be further reduced or a considerable income could be generated if the values of saltwater and freshwater products are considered. Overall, the techno-economic analysis results indicated that the proposed integrated SC system could potentially treat produced water at a cost significantly lower than the cost of produced water treatment by conventional technologies. To evaluate the feasibility of the proposed treatment system at a laboratory scale, a SC salt precipitation and membrane distillation system was designed and fabricated to treat a simulated brine or pretreated produced water by precipitating salts and further polishing the SC steam containing ~100 ppm salts to a high-purity steam. Through baseline tests with NaCl solutions, with concentrations ranging from 30,000 to 200,000 ppm, it was demonstrated that concentrated feed solutions could be treated by precipitating salt at SC conditions to a TDS level of 130 ppm. Produced water samples were collected from a potential CO 2 sequestration site, a coal-bed methane site, and an oilfield in Illinois. Representative samples were characterized for various water quality parameters, including pH; turbidity; conductivity; and concentrations of selected anions, cations, alkalinity, dissolved organic carbon, total suspended solids, TDS, and total petroleum hydrocarbons. The produced water samples were first treated by conventional pretreatment methods to remove residual oil, dissolved organic matter, and scale-forming species. Pretreatment methods included coagulation, sedimentation, filtration, activated carbon adsorption, and ion-exchange adsorption. Pretreated produced waters were treated at SC conditions in which salts were precipitated. Analysis of treated samples revealed that the concentration of Na (the main cation) in produced waters was reduced dramatically from 14,000–47,400 ppm in the feed to 21–80 ppm in treated waters. Concentrations of other main cations (Ca, Mg, Sr, K) also decreased significantly from initial values of ~1,000–22,000 ppm to ~1 ppm or less. However, a significant increase in the concentrations of Fe, Ni, Cu, and Co was observed, mainly caused by leaching of these elements from the system (vessels, filters, tubing), which is manufactured from alloys containing Fe, Ni, Cu, and Co. To polish the SC steam containing a salt content of ~100 ppm to a high-purity level of <1 ppm, a SC membrane distillation treatment using carbon membranes was employed. Different types of self-standing or supported carbon membranes were developed from graphite, graphene, carbon nanotubes, carbon nanofibers, and pyrolytic carbon. Screening tests revealed that only a limited number of developed carbon membranes were suitable for the purification of steam at SC conditions. Membranes that were either fragile and lacked mechanical strength or had large pores and showed limited salt rejection (<20%) were found to be unsuitable for the purification of SC steam. Promising carbon membranes that were successfully tested for purifying SC steam included two graphite membranes (i.e., AF-5, a porous graphite material, and FGS, a flexible graphite sheet) and a carbon nanotube membrane grown on a Hastelloy substrate and then further modified using a proprietary method (i.e., membrane C). The AF-5 membrane exhibited a stable water flux of ~50 kg/m 2 ∙h and ~40% salt rejection. The FGS membrane had a high salt rejection of 95%–98% but a lower water flux of ~15 kg/m 2 ∙h. Membrane C showed an extremely high flux of 200-800 kg/m 2 ∙h, which is one order of magnitude higher than the water flux of conventional membranes. Membrane C also exhibited 87%–93% salt rejection. Overall, a two-stage or multistage polishing treatment by these membranes could lower the salt content of the SC steam from initial values of ~100–200 ppm to the steam quality of <1 ppm or to parts per billion levels required for the power cycle.

20 FOSSIL-FUELED POWER PLANTS↗

Modeling Subsurface Performance of a Geothermal Reservoir Using Machine Learning

Geothermal power plants typically show decreasing heat and power production rates over time. Mitigation strategies include optimizing the management of existing wells—increasing or decreasing the fluid flow rates across the wells—and drilling new wells at appropriate locations. The latter is expensive, time-consuming, and subject to many engineering constraints, but the former is a viable mechanism for periodic adjustment of the available fluid allocations. In this study, we describe a new approach combining reservoir modeling and machine learning to produce models that enable such a strategy. Our computational approach allows us, first, to translate sets of potential flow rates for the active wells into reservoir-wide estimates of produced energy, and second, to find optimal flow allocations among the studied sets. In our computational experiments, we utilize collections of simulations for a specific reservoir (which capture subsurface characterization and realize history matching) along with machine learning models that predict temperature and pressure timeseries for production wells. We evaluate this approach using an “open-source” reservoir we have constructed that captures many of the characteristics of Brady Hot Springs, a commercially operational geothermal field in Nevada, USA. Selected results from a reservoir model of Brady Hot Springs itself are presented to show successful application to an existing system. In both cases, energy predictions prove to be highly accurate: all observed prediction errors do not exceed 3.68% for temperatures and 4.75% for pressures. In a cumulative energy estimation, we observe prediction errors that are less than 4.04%. A typical reservoir simulation for Brady Hot Springs completes in approximately 4 h, whereas our machine learning models yield accurate 20-year predictions for temperatures, pressures, and produced energy in 0.9 s. This paper aims to demonstrate how the models and techniques from our study can be applied to achieve rapid exploration of controlled parameters and optimization of other geothermal reservoirs.

15 GEOTHERMAL ENERGY↗

P-model v1.0: an optimality-based light use efficiency model for simulating ecosystem gross primary production

Terrestrial photosynthesis is the basis for vegetation growth and drives the land carbon cycle. Accurately simulating gross primary production (GPP, ecosystem-level apparent photosynthesis) is key for satellite monitoring and Earth system model predictions under climate change. While robust models exist for describing leaf-level photosynthesis, predictions diverge due to uncertain photosynthetic traits and parameters which vary on multiple spatial and temporal scales. Here, we describe and evaluate a GPP (photosynthesis per unit ground area) model, the P-model, that combines the Farquhar–von Caemmerer–Berry model for C 3 photosynthesis with an optimality principle for the carbon assimilation–transpiration trade-off, and predicts a multi-day average light use efficiency (LUE) for any climate and C 3 vegetation type. The model builds on the theory developed in Prentice et al. (2014) and Wang et al. (2017a) and is extended to include low temperature effects on the intrinsic quantum yield and an empirical soil moisture stress factor. The model is forced with site-level data of the fraction of absorbed photosynthetically active radiation (fAPAR) and meteorological data and is evaluated against GPP estimates from a globally distributed network of ecosystem flux measurements. Although the P-model requires relatively few inputs, the R 2 for predicted versus observed GPP based on the full model setup is 0.75 (8 d mean, 126 sites) – similar to comparable satellite-data-driven GPP models but without predefined vegetation-type-specific parameters. The R 2 is reduced to 0.70 when not accounting for the reduction in quantum yield at low temperatures and effects of low soil moisture on LUE. The R 2 for the P-model-predicted LUE is 0.32 (means by site) and 0.48 (means by vegetation type). Applying this model for global-scale simulations yields a total global GPP of 106–122 Pg C yr –1 (mean of 2001–2011), depending on the fAPAR forcing data. The P-model provides a simple but powerful method for predicting – rather than prescribing – light use efficiency and simulating terrestrial photosynthesis across a wide range of conditions. The model is available as an R package (rpmodel).

54 ENVIRONMENTAL SCIENCES↗

Model-based feasibility assessment and evaluation of prostate hyperthermia with a commercial MR-guided endorectal HIFU ablation array

Purpose: Feasibility of targeted and volumetric hyperthermia (40–45 °C) delivery to the prostate with a commercial MR-guided endorectal ultrasound phased array system, designed specifically for thermal ablation and approved for ablation trials (ExAblate 2100, Insightec Ltd.), was assessed through computer simulations and tissue-equivalent phantom experiments with the intention of fast clinical translation for targeted hyperthermia in conjunction with radiotherapy and chemotherapy. Methods: The simulations included a 3D finite element method based biothermal model, and acoustic field calculations for the ExAblate ERUS phased array (2.3 MHz, 2.3 × 4.0 cm{sup 2}, ∼1000 channels) using the rectangular radiator method. Array beamforming strategies were investigated to deliver protracted, continuous-wave hyperthermia to focal prostate cancer targets identified from representative patient cases. Constraints on power densities, sonication durations and switching speeds imposed by ExAblate hardware and software were incorporated in the models. Preliminary experiments included beamformed sonications in tissue mimicking phantoms under MR temperature monitoring at 3 T (GE Discovery MR750W). Results: Acoustic intensities considered during simulation were limited to ensure mild hyperthermia (T{sub max} < 45 °C) and fail-safe operation of the ExAblate array (spatial and time averaged acoustic intensity I{sub SATA} < 3.4 W/cm{sup 2}). Tissue volumes with therapeutic temperature levels (T > 41 °C) were estimated. Numerical simulations indicated that T > 41 °C was calculated in 13–23 cm{sup 3} volumes for sonications with planar or diverging beam patterns at 0.9–1.2 W/cm{sup 2}, in 4.5–5.8 cm{sup 3} volumes for simultaneous multipoint focus beam patterns at ∼0.7 W/cm{sup 2}, and in ∼6.0 cm{sup 3} for curvilinear (cylindrical) beam patterns at 0.75 W/cm{sup 2}. Focused heating patterns may be practical for treating focal disease in a single posterior quadrant of the prostate and diffused heating patterns may be useful for heating quadrants, hemigland volumes or even bilateral targets. Treatable volumes may be limited by pubic bone heating. Therapeutic temperatures were estimated for a range of physiological parameters, sonication duty cycles and rectal cooling. Hyperthermia specific phasing patterns were implemented on the ExAblate prostate array and continuous-wave sonications (∼0.88 W/cm{sup 2}, 15 min) were performed in tissue-mimicking material with real-time MR-based temperature imaging (PRFS imaging at 3.0 T). Shapes of heating patterns observed during experiments were consistent with simulations. Conclusions: The ExAblate 2100, designed specifically for thermal ablation, can be controlled for delivering continuous hyperthermia in prostate while working within operational constraints.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proposal and evaluation of subordinate standard solar irradiance spectra for applications in solar energy systems

Reference solar irradiance spectra are needed to specify key parameters of solar technologies such as photovoltaic cell efficiency, in a comparable way. The IEC 60904-3 and ASTM G173 standards present such spectra for Direct Normal Irradiance (DNI) and Global Tilted Irradiance (GTI) on a 37 degrees tilted sun-facing surface for one set of clear-sky conditions with an air mass of 1.5 and low aerosol content. The IEC/G173 standard spectra are the widely accepted references for these purposes. Hence, the authors support the future replacement of the outdated ISO 9845 spectra with the IEC spectra within the ongoing update of this ISO standard. The use of a single reference spectrum per component of irradiance is important for clarity when comparing and rating solar devices such as PV cells. However, at some locations the average spectra can differ strongly from those defined in the IEC/G173 standards due to widely different atmospheric conditions and collector tilt angles. Therefore, additional subordinate standard spectra for other atmospheric conditions and tilt angles are of interest for a rough comparison of product performance under representative field conditions, in addition to using the main standard spectrum for product certification under standard test conditions. This simplifies the product selection for solar power systems when a fully-detailed performance analysis is not feasible (e.g. small installations). Also, the effort for a detailed yield analyses can be reduced by decreasing the number of initial product options. After appropriate testing, this contribution suggests a number of additional spectra related to eight sets of atmospheric conditions and tilt angles that are currently considered within ASTM and ISO working groups. The additional spectra, called subordinate standard spectra, are motivated by significant spectral mismatches compared to the IEC/G173 spectra (up to 6.5%, for PV at 37 degrees tilt and 10-15% for CPV). These mismatches correspond to potential accuracy improvements for a quick estimation of the average efficiency by applying the appropriate subordinate standard spectrum instead of the IEC/G173 spectra. The applicability of these spectra for PV performance analyses is confirmed at five test sites, for which subordinate spectra could be intuitively selected based on the average atmospheric aerosol optical depth (AOD) and precipitable water vapor at those locations. The development of subordinate standard spectra for DNI and concentrating solar power (CSP) and concentrating PV (CPV) is also considered. However, it is found that many more sets of atmospheric conditions would be required to allow the intuitive selection of DNI spectra for the five test sites, due in particular to the stronger effect of AOD on DNI compared to GTI. In conclusion, the matrix of subordinate GTI spectra described in this paper are recommended to appear as an option in the annex of future standards, in addition to the obligatory use of the main spectrum from the ASTM G173 and IEC 60904 standards.

14 SOLAR ENERGY↗

Diagnostics, Control and Performance Parameters for the BELLA High Repetition Rate Petawatt Class Laser

A laser system producing controllable and stable pulses with high power and ultrashort duration at high repetition rate is a key component of a high energy laser-plasma accelerator (LPA). Precise characterization and control of laser properties are essential to understanding laser-plasma interactions required to build a 10-GeV class LPA. This study discusses the diagnostics, control and performance parameters of a 1 Hz, 1 petawatt (PW) class laser at the Berkeley Lab Laser Accelerator (BELLA) facility. The BELLA PW laser provided up to 46 J on target with a 1% level energy fluctuation and 1.3-μrad pointing stability. The spatial profile was measured and optimized by using a camera, wavefront sensor, and deformable mirror (ILAO system). The focus waist was measured to be r 0 = 53 μm and the fraction of energy within the circular area defined by the first minimum of the diffraction pattern (r = 67 μm) was 0.75. The temporal profile was controlled via the angle of incidence on a stretcher and a compressor, as well as an acousto-optic programmable dispersive. The temporal pulse shape was measured to be about 33 fs in full width at half maximum (WIZZLER and GRENOUILLE diagnostics). In order to accurately evaluate peak intensity, the energy-normalized peak fluence, and energy-normalized peak power were analyzed for the measured spatial and temporal mode profiles, and were found to be 15 kJ/(cm 2 J) with 6% fluctuation (standard deviation) and 25 TW/J with 5% fluctuation for 46-J on-target energy, respectively. This yielded a peak power of 1.2 PW and a peak intensity of 17×10 18 W/cm 2 with 8% fluctuation. A method to model the pulse shape for arbitrary compressor grating distance with high accuracy was developed. The pulse contrast above the amplified spontaneous emission pedestal was measured by SEQUOIA and found to be better than 10 9 . The first order spatiotemporal couplings (STCs) were measured with GRENOUILLE, and a simulation of the pulse's evolution at the vicinity of the target was presented. A maximum pulse front tilt angle of less than 7 mrad was achieved. The reduction of the peak power caused by the first order STCs was estimated to be less than 1%. Finally, the capabilities described in this paper are essential for generation of high quality electron beams.

47 OTHER INSTRUMENTATION↗

Application of a temporal multiscale method for efficient simulation of degradation in PEM Water Electrolysis under dynamic operating conditions

Hydrogen is emerging as a vital energy carrier, driven by the need to reduce carbon emissions. Proton Electrolyte Membrane Water Electrolysis (PEMWE) enables hydrogen production under fluctuating renewable power conditions but requires improved understanding and stability of the anode catalyst layer under dynamic operating conditions, especially with low noble metal loadings. Long-term degradation experiments are both time-consuming and costly; therefore, a systematic, model-aided approach is essential. In the present work, a temporal multiscale method is applied to reduce the computational effort of simulating long-term degradation processes in PEMWE, with an exemplary focus on catalyst dissolution. A mechanistic model incorporating the oxygen evolution reaction, catalyst dissolution, and hydrogen permeation from the cathode to the anode was hypothesized and implemented. In this way, the local periodicity of transport and reaction processes in dynamic PEMWE operation, which influence the gradual degradation of the catalyst layer, is captured. The temporal multiscale method significantly reduces the computational effort of simulation, decreasing processing time from hours to mere minutes. This efficiency gain is attributed to the limited evolution of Slow-Scale variables during each period of time P of the Fast-Scale variables. Consequently, simulation is required only until local periodicity is achieved within each Slow-Scale time step. Hence, the fully resolved dynamic problem is decoupled into these two scales, employing a heterogeneous multiscale technique. The developed approach effectively accelerates parameter estimation and predictive simulations, supporting systematic modeling of PEMWE degradation under dynamic conditions.

08 HYDROGEN↗

High-Burnup BWR LOCA Burst Analysis Using High-Fidelity Multiphysics Simulations

The US nuclear industry is looking to improve on the operating economics of the current fleet of light-water reactors (LWRs). One way of achieving this is by operating fuel to higher burnup. In pressurized water reactors (PWRs), relaxing the current burnup limit will allow for cycle length extensions and power uprates; in boiling water reactors (BWRs) it may allow for improved fuel utilization and reduced feed assemblies, as well as more efficient power uprates and increased capacity factors that will support the Administration’s Executive Order to facilitate 5 GW of power uprates at existing nuclear facilities. However, one of the key limitations to operating fuel to higher burnup is the risk of fuel fragmentation, relocation, and dispersal (FFRD). Recognizing the high interest in extending burnup limits, the US Nuclear Regulatory Commission (NRC) has issued Draft Regulatory Guide DG-1434, which defines an approach that would be acceptable to the NRC for addressing FFRD risk. The approach defined will require better understanding of the phenomena leading to FFRD as well as best-estimate simulation methods to understand FFRD risk in high-burnup cores. The Nuclear Energy Advanced Modeling and Simulation program is supporting the FFRD industry challenge problem through development of state-of-the-art, high-fidelity modeling and simulation LWR analysis capabilities; namely, the BISON fuel performance code and the VERA core simulator software. These tools, along with the US NRC TRACE system analysis code, have been utilized for analysis of FFRD risk in both PWR and BWR cores in recent years. The work documented in this report addresses the lack of high-fidelity research for BWRs and builds on a previous activity where the framework has been applied to Cycles 16 through 18 of Limerick Unit 1, a BWR/4, with introduction of 8 high-burnup lead use assemblies (HBLUAs) that were representative of the 8 HBLUAs loaded into Limerick Unit 2 in 2021. VERA was used in this previous activity to model rod-by-rod depletion in these cycles, and its solution was used to initialize a TRACE simulation of a large-break loss-of-coolant accident (LBLOCA) at the end of Cycle 18. In the work documented in this report, the TRACE model was improved by refining the core mesh and utilizing a new feature that allows for capturing the full 3D VERA power distribution in the model. This allows for a more detailed solution for setting BISON boundary conditions. Furthermore, the solutions from VERA and TRACE were used to set up and perform BISON simulations of about 1,000 rods sampled from the core, including all burnup levels. Utilizing two cladding burst models, it was shown that no fuel rods were predicted to burst during the postulated LBLOCA transient. Additionally, a sensitivity study was performed by artificially increasing linear heat rate during the postulated LBLOCA to identify parameters that correlate with rod burst susceptibility. Burnup, fission gas release, and hoop strain were all found to be positively correlated with rod burst susceptibility. Small-break loss-of-coolant accident (SBLOCA) analyses were also performed; these analyses predicted cladding temperature increases that were bounded by the LBLOCA cladding temperatures for all small break sizes studied for this plant. However, future refinements to the plant response assumptions during the SBLOCA could impact the predicted cladding response. Finally, a benchmark study was performed between CTF and TRACE for LOCA conditions to better qualify CTF for BWR LOCA modeling.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Critical Literature Review of Low Global Warming Potential (GWP) Refrigerants and their Environmental Impact

Refrigeration and air conditioning currently account for ~20% of the total electricity consumption in buildings around the world. Over the next three decades as global temperatures are projected to increase, urbanization and economic growth will lead to an increased demand for refrigeration and cooling. Most commonly used refrigerants belong to the five following classes: (i) chlorofluorocarbons, (ii) hydrochlorofluorocarbons, (iii) hydrofluorocarbons (HFCs), (iv) hydrofluoroolefins (HFOs), and (v) natural refrigerants. Over the past century, there have been shifts in which compounds were used for refrigeration to improve safety and durability, allow for ozone protection, and, most recently, to reduce global warming potential (GWP). Although technological advances have led to increased cooling capacity and safer refrigerants, emissions from refrigeration systems can affect the environment by contributing to greenhouse gas emissions or by depleting the ozone layer, depending on the gas emitted. The focus is increasingly on adopting compounds that are both efficient at cooling and effective for reducing emissions and other adverse environmental impacts. Because of policy and regulatory changes to avert ozone depletion and global climate change, much discussion has centered on the environmental impacts of next-generation refrigerants. Of particular interest are the fluorinated refrigerants, HFCs and HFOs, most of which are defined as per- and polyfluoroalkyl substances (PFAS) and their breakdown products (especially trifluoroacetic acid). The US Environmental Protection Agency in 2021 drafted a Strategic Roadmap for PFAS, which has already resulted in an increase in investment in research on these compounds and has restricted the release of PFAS into the environment through the implementation of monitoring and reporting requirements. A critical evaluation of fluorinated refrigerants and their breakdown products with respect to persistence, biodegradation and toxicity, and global warming potential is needed to guide environmental regulations. This document aims to perform a critical review of the relevant scientific data on the most common refrigerants currently used, their degradation products, and their alternatives. Where available, estimates of precursor production quantities and existing environmental regulatory information are reviewed. Key data of interest for the evaluation include physicochemical properties, environmental fate parameters, ecological or human health toxicity/risk information, and GWP for compounds of interest.

54 ENVIRONMENTAL SCIENCES↗

Critical Literature Review of Low Global Warming Potential (GWP) Refrigerants and their Environmental Impact

Refrigeration and air conditioning currently account for ~20% of the total electricity consumption in buildings around the world. Over the next three decades as global temperatures are projected to increase, urbanization and economic growth will lead to an increased demand for refrigeration and cooling. Most commonly used refrigerants belong to the five following classes: (i) chlorofluorocarbons, (ii) hydrochlorofluorocarbons, (iii) hydrofluorocarbons (HFCs), (iv) hydrofluoroolefins (HFOs), and (v) natural refrigerants. Over the past century, there have been shifts in which compounds were used for refrigeration to improve safety and durability, allow for ozone protection, and, most recently, to reduce global warming potential (GWP). Although technological advances have led to increased cooling capacity and safer refrigerants, emissions from refrigeration systems can affect the environment by contributing to greenhouse gas emissions or by depleting the ozone layer, depending on the gas emitted. The focus is increasingly on adopting compounds that are both efficient at cooling and effective for reducing emissions and other adverse environmental impacts. Because of policy and regulatory changes to avert ozone depletion and global climate change, much discussion has centered on the environmental impacts of next-generation refrigerants. Of particular interest are the fluorinated refrigerants, HFCs and HFOs, most of which are defined as per- and polyfluoroalkyl substances (PFAS) and their breakdown products (especially trifluoroacetic acid). The US Environmental Protection Agency in 2021 drafted a Strategic Roadmap for PFAS, which has already resulted in an increase in investment in research on these compounds and has restricted the release of PFAS into the environment through the implementation of monitoring and reporting requirements. A critical evaluation of fluorinated refrigerants and their breakdown products with respect to persistence, biodegradation and toxicity, and global warming potential is needed to guide environmental regulations. This document aims to perform a critical review of the relevant scientific data on the most common refrigerants currently used, their degradation products, and their alternatives. Where available, estimates of precursor production quantities and existing environmental regulatory information are reviewed. Key data of interest for the evaluation include physicochemical properties, environmental fate parameters, ecological or human health toxicity/risk information, and GWP for compounds of interest.

54 ENVIRONMENTAL SCIENCES↗

Event-by-Event Evaluation of the Prompt Fission Neutron Spectrum From 239 Pu(n,f)

We have developed an improved evaluation method for the spectrum of neutrons emitted in fission of 239 Pu induced by incident neutrons with energies up to 20 MeV. The <v> covariance data, including incident energy correlations introduced by the <v> evaluation method, were used to fix the input parameters in our event-by-event model of fission, FREYA, by applying formal statistical methods. Formal estimates of uncertainties in the evaluation were developed by randomly sampling model inputs and calculating likelihood functions based on agreement with the evaluated <v>. Our approach is able to employ a greater variety of fission measurements than the relatively coarse spectral data alone. It also allows the study of numerous fission observables for more accurate model validation. The combination of an event-by-event Monte Carlo fission model with a statistical-likelihood analysis is thus a powerful tool for evaluation of fission-neutron data. Our empirical model FREYA follows the complete fission event from birth of the excited fragments through their decay via neutron emission until the fragment excitation energy is below the neutron separation energy when neutron emission can no longer occur. The most recent version of FREYA incorporates pre-equilibrium neutron emission, the emission of the first neutron before equilibrium is reached in the compound nucleus, and multi-chance fission, neutron evaporation prior to fission when the incident neutron energy is above the neutron separation energy. Energy, momentum, charge and mass number are conserved throughout the fission process. The best available values of fragment masses and total kinetic energies are used as inputs to FREYA. We fit three parameters that are not well under control from previous measurements: the shift in the total fragment kinetic energy; the energy scale of the asymptotic level density parameter, controlling the fragment 'temperature' for neutron evaporation; and the relative excitation of the light and heavy fragments, governing the number and energy of neutrons emitted from each fragment. The latter two parameters are assumed to be independent of the incident neutron energy while the first varies with incident energy. We describe our method and the subsequent spectral evaluation and present the results of several standard validation calculations that test our new evaluation. These benchmarks include critical assemblies, sensitive to criticality in fast systems; pulsed sphere measurements testing the spectra at incident neutron energies of 14 MeV; and other tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of Real-Time System Identification to Detect Abnormal Operations in a Gas Turbine Cycle

Here, we present a novel online system identification methodology for monitoring the performance of power systems. This methodology was demonstrated in a gas turbine recuperated power plant designed for a hybrid configuration. A 120-kW Garrett microturbine modified to test dynamic control strategies for hybrid power systems designed at the National Energy Technology Laboratory (NETL) was used to implement and validate this online system identification methodology. The main component of this methodology consists of an empirical transfer function model implemented in parallel to the turbine speed operation and the fuel control valve, which can monitor the process response of the gas turbine system while it is operating. During fully closed-loop operations or automated control, the output of the controller, fuel valve position, and the turbine speed measurements were fed for a given period of time to a recursive algorithm that determined the transfer function parameters during the nominal condition. After the new parameters were calculated, they were fed into the transfer function model for online prediction. The turbine speed measurement was compared against the transfer function prediction, and a control logic was implemented to capture when the system operated at nominal or abnormal conditions. To validate the ability to detect abnormal conditions during dynamic operations, drifting in the performance of the gas turbine system was evaluated. A leak in the turbomachinery working fluid was emulated by bleeding 10% of the airflow from the compressor discharge to the atmosphere, and electrical load steps were performed before and after the leak. This tool could detect the leak 7 s after it had occurred, which accounted for a fuel flow increase of approximately 15.8% to maintain the same load and constant turbine speed operations.

algorithms↗

A defense in depth approach for nuclear power plant accident management

An initiating event may lead to a severe accident if the plant safety functions have been challenged or operators do not follow the appropriate accident management procedures. Beyond design basis accidents are those corresponding to events of very low occurrence probability but such an accident may lead to significant consequences. The defense in depth approach is important to assure nuclear safety even in a severe accident. Plant Damage States (PDS) can be defined by the combination of the possible values for each of the PDS parameters which are showed on the nuclear power plant simulator. PDS is used to identify what the initiating event is, and can also give the information of safety system's status whether they are bypassed, inoperable or not. Initiating event and safety system's status are used in the construction of Containment Event Tree (CET) to determine containment failure modes by using probabilistic risk assessment (PRA) technique. Different initiating events will correspond to different CETs. With these CETs, the core melt frequency of an initiating event can be found. The use of Plant Damage States (PDS) is a symptom-oriented approach. On the other hand, the use of Containment Event Tree (CET) is an event-oriented approach. In this study, the Taiwan's fourth nuclear power plants, the Lungmen nuclear power station (LNPS), which is an advanced boiling water reactor (ABWR) with fully digitized instrumentation and control (I and C) system is chosen as the target plant. The LNPS full scope engineering simulator is used to generate the testing data for method development. The following common initiating events are considered in this study: loss of coolant accidents (LOCA), total loss of feedwater (TLOFW), loss of offsite power (LOOP), station blackout (SBO). Studies have indicated that the combination of the symptom-oriented approach and the event-oriented approach can be helpful to find mitigation strategies and is useful for the accident management. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Correcting for Selection Biases in the Determination of the Hubble Constant from Time-Delay Cosmography

The time delay between multiple images of strongly lensed quasars has been used to infer the Hubble constant. The primary systematic uncertainty for time-delay cosmography is the mass-sheet transform (MST), which preserves the lensing observables while altering the inferred ⁠H 0 . The TDCOSMO collaboration used velocity dispersion measurements of lensed quasars and lensed galaxies to infer that mass sheets are present, which decrease the inferred H 0 by 8 per cent. Here, we test the assumption that the density profiles of galaxy–galaxy and galaxy–quasar lenses are the same. We use a composite star-plus-dark-matter mass profile for the parent deflector population and model the selection function for galaxy–galaxy and galaxy–quasar lenses. We find that a power-law density profile with an MST is a good approximation to a two-component mass profile around the Einstein radius, but we find that galaxy–galaxy lenses have systematically higher mass-sheet components than galaxy–quasar lenses. For individual systems, λ int correlates with the ratio of the half-light radius and Einstein radius of the lens. By propagating these results through the TDCOSMO hierarchical inference code, we find that H 0 is lowered by a further 3 per cent. Using a more recent measurement of velocity dispersions and our fiducial model for selection biases, we infer H 0 = 66 ± 4 (stat) ± 1 (model sys) ± 2 (measurement sys) km s -1 Mpc -1 for the TDCOSMO plus SLACS data set. The first residual systematic error is due to plausible alternative choices in modelling the selection function, and the second is an estimate of the remaining systematic error in the measurement of velocity dispersions for SLACS lenses. Accurate time-delay cosmography requires precise velocity dispersion measurements and accurate calibration of selection biases.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of Corrosion- and Erosion-Resistant Coatings for Advanced Ultra-Supercritical Materials

This final report summarized the research efforts and major findings of the Phase I Project “Development of Corrosion- and Erosion-Resistant Coatings for Advanced Ultra-Supercritical Materials”, for the period of October 1, 2019 – Sept. 30, 2021. This project is a collaborative endeavor between Tennessee Tech University, Purdue University, Oak Ridge National Laboratory, Siemens Corporation, and Eastern Plating, LLC, aiming at improving the durability and lifetime of high-pressure (HP) steam turbine blades in advanced ultra-supercritical (A-USC) coal-fired power plants through the development of corrosion/erosion-resistant coatings manufactured via a low-cost electrolytic codeposition process. While Tribaloy alloy T-400C was identified by the U.S. A-USC Materials Consortium as a promising coating composition, further composition optimization is needed to enhance its corrosion and erosion resistance for protecting the A-USC Ni-base turbine components. An integrated computational and experimental approach was employed to optimize coating composition/microstructure and processing parameters. In order to identify candidate coating compositions that could offer balanced properties, thermodynamic calculations were performed to explore the γ+Laves composition space in the Co-Ni-Cr-Mo-Si system with different alloying additions at 600-800 °C. Guided by the calculation results, experimental assessment of selected alloys led to the development of a new generation of Tribaloy compositions with the optimal levels of Cr, Mo and Si, reactive element (e.g., 0.4-0.6 wt.% Y) and other alloying additions. The low-cost and non-line-of-sight electro-codeposition process was employed to deposit a Ni(Co)-CrMoSiY composite coating on commercial Haynes 282 (H282) Ni-base alloy. A diffusion treatment was subsequently applied to convert the composite to the Tribaloy-type coating. Both the codeposition parameters and heat treatment conditions were varied to achieve the desired coating composition, microstructure and phase constituents. In addition, since additive manufacturing (AM) may be an alternative cost-saving option for potential A-USC turbine repair, laser direct deposition was explored to fabricate the H282 alloy with minimal defects. The electro-codeposited Tribaloy coating was also applied to the AM H282 substrate to demonstrate the viability of the coating process in improving the surface finish of AM alloys. Both high-temperature oxidation performance and solid particle erosion (SPE) resistance of model alloys and electro-codeposited coatings were evaluated. About 25 model alloys with various Cr/Mo ratios and reactive element levels, as well as partial substitution of Mo with Nb were evaluated with regard to their oxidation resistance in both air and pure steam at 760-800°C. Compositions based on Ni(Co)-20Cr-18Mo-2.6Si-0.6Y (wt.%) showed significantly improved oxidation resistance over the baseline T400-C. Based on the alloy development results, three generations of new Tribaloy coatings (Gen-1, Gen-2, and Gen-3) with various Mo/Cr contents and Y levels were prepared via electro-codeposition and their microstructure/performance were evaluated. Outstanding air and steam oxidation resistance was achieved for the Gen-2 and Gen-3 coatings. Furthermore, while the SPE resistance of the coatings depended on many factors such as temperature, environment, erodent, velocity and impact angle, the coated samples exhibited similar or better SPE resistance compared to the H282 substrate when magnetite was used as erodent (which is a realistic erodent in A-USC steam turbines). The new Tribaloy coatings also had good long-term compatibility with the H282 alloy substrate. The two large-sized rotating barrels were designed, constructed, and employed to coat dummy HP blades. Uniform coating thickness and microstructure were achieved at various blade locations. Also, a preliminary techno-economic analysis of the proposed coating process was conducted to quantify the cost-effectiveness and to assess the commercial viability of the corrosion- and erosion-resistant coatings. It is estimated that a cost reduction of ~30% could be achieved with the electro-codeposition coating process over the state-of-the-art high velocity oxygen fuel (HVOF) thermal spray. Compared to the leading Tribaloy coating technologies such as HVOF and plasma transfer alloying, electro-codeposition based process has advantages such as low-cost process equipment, uniform deposition even for complex shapes, low levels of contaminants/porosities, reduction of powder waste, and potentially better surface finish and longer turbine service life. The Phase 1 study has demonstrated that it is feasible to develop an electro-codeposited Tribaloy coating with balanced corrosion and erosion properties, even though additional research efforts such as further coating process scale-up and longer-term performance evaluation under realistic A-USC conditions are clearly needed.

20 FOSSIL-FUELED POWER PLANTS↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Risk-Informed MultiPphysics BestEestimate Plus Uncertainties (BEPU) Application Development of RELAP5-3D Perturbation Model

The United States nuclear industry is facing a strong challenge to ensure maximum safety while enhancing economic benefit. Safety is a key parameter to all aspects related to light water reactor (LWR) nuclear power plants (NPPs), especially cost savings. Since the goal is to extend the lifetimes of these NPPs, the traditional deterministic safety concept may not guarantee a current economic asset. The Light Water Reactor Sustainability (LWRS) Program has been promoting a wide range of research and development (R&D) in this field to maximize the safety, economics, and performance of these NPPs through improved scientific understanding. One of the best practices to achieve this goal is to identify and optimize safety margins, which can lead to cost reduction. To do this, under the LWRS framework, the Risk-Informed Systems Analysis (RISA) Pathway will focus on the optimization of safety margin and minimization of uncertainties to ensure both safety and economics at the highest level. The RISA Pathway will provide enhanced capabilities for analyzing and characterizing LWR systems performance by developing and demonstrating methods, tools, and data to enable risk-informed margins management (RIMM). The goals of the RISA Pathway are twofold: (1) deploy the risk-informed tools and methods that enable better representation of safety margins and factors that contribute to cost and safety; and (2) conduct advanced risk assessment applications with industry to support margin management strategies that enable more cost-effective plant operation. The tools and methods provided by the RISA Pathway will support effective margin management for both active and passive safety systems, structures, and components (SSC) of an NPP. The tools and methods used in the RISA Pathway should have high confidence and highest technical maturity for and implementation to industry at its current setting. They should also have a capability to support risk-informed decision making for both probabilistic and deterministic elements of safety. The RISA Pathway will, therefore, perform a comprehensive assessment of verification and validation (V&V) status of RISA Toolkit to enhance credibility RISA Toolkit which be used by industry. This report summarizes RELAP5-3D development activities for best estimated and uncertainty (BEPU) capability to support ongoing RISA Pathway pilot projects for risk informed uncertainty quantification applications. Work scope includes (1) development of initial perturbation model for selected closure laws and (2) testing of suitable probability distribution functions (PDF) for the selected correlations. Developed BEPU modules are tested with selected separate effect cases and compared with conventional thermal-hydraulics model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗