Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “passivating layer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

InGaP/InGaAs-on-Ge Concentrator Solar Cell for Space Power Generation

The passivating front and back window layer of the top cell has been chosen. We have chosen to use InGaAs as the tunnel junction interconnect compound since it is easily degenerately doped. All of the dual junction cell structures were grown on GaAs substrates. Time constraints prevented us from completing the development of the GaAs-on-Ge growth process. Analysis of the I-V and EQE data, and comparison with computer-modeled data, shows that the performance of the dual-junction cell is still being controlled by the bottom cell, in spite of top cell thinning. Further improvement in the dual-junction cell efficiency is possible by thinning the front window.

Sinharoy, Samar↗

Prediction and Measurement of the Vibration and Acoustic Radiation of Panels Subjected to Acoustic Loading

Interior noise and sonic fatigue are important issues in the development and design of advanced subsonic and supersonic aircraft. Conventional aircraft typically employ passive treatments, such as constrained layer damping and acoustic absorption materials, to reduce the structural response and resulting acoustic levels in the aircraft interior. These techniques require significant addition of mass and only attenuate relatively high frequency noise transmitted through the fuselage. Although structural acoustic coupling is in general very important in the study of aircraft fuselage interior noise, analysis of noise transmission through a panel supported in an infinite rigid baffle (separating two semi-infinite acoustic domains) can be useful in evaluating the effects of active/adaptive materials, complex loading, etc. Recent work has been aimed at developing adaptive and/or active methods of controlling the structural acoustic response of panels to reduce the transmitted noise1. A finite element formulation was recently developed to study the dynamic response of shape memory alloy (SMA) hybrid composite panels (conventional composite panel with embedded SMA fibers) subject to combined acoustic and thermal loads2. Further analysis has been performed to predict the far-field acoustic radiation using the finite element dynamic panel response prediction3. The purpose of the present work is to validate the panel vibration and acoustic radiation prediction methods with baseline experimental results obtained from an isotropic panel, without the effect of SMA.

Turner, Travis L.↗

Active Damping Using Distributed Anisotropic Actuators

A helicopter structure experiences substantial high-frequency mechanical excitation from powertrain components such as gearboxes and drive shafts. The resulting structure-borne vibration excites the windows which then radiate sound into the passenger cabin. In many cases the radiated sound power can be reduced by adding damping. This can be accomplished using passive or active approaches. Passive treatments such as constrained layer damping tend to reduce window transparency. Therefore this paper focuses on an active approach utilizing compact decentralized control units distributed around the perimeter of the window. Each control unit consists of a triangularly shaped piezoelectric actuator, a miniature accelerometer, and analog electronics. Earlier work has shown that this type of system can increase damping up to approximately 1 kHz. However at higher frequencies the mismatch between the distributed actuator and the point sensor caused control spillover. This paper describes new anisotropic actuators that can be used to improve the bandwidth of the control system. The anisotropic actuators are composed of piezoelectric material sandwiched between interdigitated electrodes, which enables the application of the electric field in a preferred in-plane direction. When shaped correctly the anisotropic actuators outperform traditional isotropic actuators by reducing the mismatch between the distributed actuator and point sensor at high frequencies. Testing performed on a Plexiglas panel, representative of a helicopter window, shows that the control units can increase damping at low frequencies. However high frequency performance was still limited due to the flexible boundary conditions present on the test structure.

Schiller, Noah H.↗

Delay of Transition Using Forced Damping

Several experiments which have reported a delay of transition are analyzed in terms of the frequencies of the induced disturbances generated by different flow control elements. Two of the experiments employed passive stabilizers in the boundary layer, one leading-edge bluntness, and one employed an active spark discharge in the boundary layer. It is found that the frequencies generated by the various elements lie in the damping region of the associated stability curve. It is concluded that the creation of strong disturbances in the damping region stabilizes the boundary-layer and delays the transition from laminar to turbulent flow.

Exton, Reginald J.↗

Thermal Control System of the ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS)

The ECOSystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS) is a thermal infrared imaging multispectral scanner science mission. ECOSTRESS is designed and built by the NASA Jet Propulsion Laboratory and will be deployed on the International Space Station (ISS). ECOSTRESS will measure the water loss from growing leaves and the evaporation from the soil by measuring the temperature of plants and will gather data on the health of the agriculture system on Earth. The ISS orbit will allow ECOSTRESS to take observations at different times during each day over the seasons to provide coverage over the contiguous United States. The ECOSTRESS Thermal Control System (TCS) consists of a combination of active and passive components to maintain the ECOSTRESS components within the allowable flight temperature (AFT) limits. The active thermal control systems include mechanical cryocoolers, heaters and a single-phase pumped fluid loop for Instrument and Payload. The focal plane detector is cooled to 65K by a pair of mechanical cryocoolers and a third mechanical cryocooler cools an intermediate cold shield to 130K. The pumped fluid loop transfers the instrument waste heat to JAXA’s Japanese Exposed Module External Facility (JEM-EF) provided external fluid loop before rejection to space from the ISS radiators. The passive TCS includes multi-layer and single layer insulations, flexible thermal links and coatings on the radiometer. This paper describes the ECOSTRESS instrument TCS architecture, instrument thermal requirements and key design drivers, the top level thermal design and analysis approach, and reports preliminary test results.

Carroll, Brian↗

The James Webb Space Telescope Mission: Optical Telescope Element Design, Development, and Performance

The James Webb Space Telescope (JWST) is a large, infrared space telescope that has recently started its science program which will enable breakthroughs in astrophysics and planetary science. Notably, JWST will provide the very first observations of the earliest luminous objects in the universe and start a new era of exoplanet atmospheric characterization. This transformative science is enabled by a 6.6 m telescope that is passively cooled with a 5 layer sunshield. The primary mirror is comprised of 18 controllable, low areal density hexagonal segments, that were aligned and phased relative to each other in orbit using innovative image-based wave front sensing and control algorithms. This revolutionary telescope took more than two decades to develop with a widely distributed team across engineering disciplines. We present an overview of the telescope requirements, architecture, development, superb on-orbit performance, and lessons learned. JWST successfully demonstrates a segmented aperture space telescope and establishes a path to building even larger space telescopes.

Infrared observatories↗

Rapid manufacturing of tailored preforms

A method for rapid manufacturing of three dimensional discontinuous fiber preforms is provided. The method includes the deposition of a polymeric material containing fibers on a surface to form a tailored charge for compression molding. The reinforced polymeric material may be a thermoplastic or a reactive polymer with viscosity low enough to allow flow through an orifice during deposition, yet high enough zero shear viscosity to retain the approximate shape of the deposited charge. The material can be deposited in a predetermined pattern to induce the desired mechanical properties through alignment of the fibers. This deposition can be performed in a single layer or in multiple layers. The alignment is achieved passively by shear alignment of the fibers or actively through fiber orientation control or mixing. The fibers can be of the desired material, length, and morphology, including short and long filaments.

Kunc, Vlastimil↗

25 years of environmental remediation in the general separations area of the Savannah river site: lessons learned about what worked and what did not work in soil and groundwater cleanup - 15270

The Savannah River Site, which is owned and administered by the US Department of Energy, covers approximately 900 square kilometers. The General Separation Area is located in the center of the site and includes: radioactive material chemical separations facilities, radioactive waste tank farms, radioactive seepage basins, and the radioactive waste burial grounds. Radioactive wastes were disposed in the General Separation Area from the mid-1950's through the mid-1990's. Operations at the F Canyon began in 1954 and at H Canyon began in 1955. Waste water disposition to the F and H Seepage Basins began soon after operations started in the canyons. The Old Radioactive Waste Burial Ground began operations in 1952 to manage solid waste that could be radioactive from all the site operations, and ceased receiving waste in 1972. The Mixed Waste Management Facility and Low Level Radioactive Waste Disposal Facility received radioactive solid waste from 1969 until 1995. Environmental legislation enacted in the 1970's through 1990's led to changes in waste management and environmental cleanup practices. The US Congress passed the Clean Air Act in 1970 and the Clean Water Act in 1972; the Resource Conservation and Recovery Act was enacted in 1976; the Comprehensive Environmental Response Compensation, and Liability Act was enacted by Congress in 1980; and the Federal Facilities Compliance Act was signed into law in 1992. Environmental remediation at the Savannah River Site essentially began with a 1987 Settlement Agreement between the Savannah River Site and the State of South Carolina. The site manages several of the larger groundwater remedial activities under the Resource Conservation and Recovery Act for facilities recognized early on as environmental problems. All subsequent remediation projects are managed under a tri-party agreement (Department of Energy, Environmental Protection Agency, and South Carolina Department of Health and Environmental Control) through the Federal Facilities Agreement. Environmental remediation activities during the past 25 years have stabilized and capped seepage basins as well as consolidated and capped waste units and burial grounds in the General Separation Area. Groundwater activities include: pump and treat systems in the groundwater, installation of deep subsurface barrier systems to manage groundwater flow, in situ chemical treatments in the groundwater, and captured contaminated groundwater discharges at the surface for management in a forest irrigation system. Concentrations of contaminants in the aquifers beneath the General Separation Area and in surface water streams in the General Separation Area have decreased over the past 25 years. Closure of 65 waste sites and 4 Resource Conservation and Recovery Act facilities has been successfully accomplished. Environmental clean-up has progressed to the stage where most of the work involves monitoring, optimization, and maintenance of existing remedial systems. Many lessons have been learned in the process of remediating the General Separations Area. Geo-textile covers outperform low permeability clay caps, especially with respect to the amount of repairs required to upkeep the drainage layers as the caps age. Passive and enhanced natural processes to address contamination are much more cost effective than pump and treat systems. Forest irrigation can be very effective in water management situations with non-accumulative contaminants such as tritium and volatile organic contaminants. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Silicon Surface Tethered Polymer as Artificial Solid Electrolyte Interface

Here, we have developed a proof of concept electrode design to covalently graft poly(methyl methacrylate) brushes directly to silicon thin film electrodes via surface-initiated atom transfer radical polymerization. This polymer layer acts as a stable artificial solid electrolyte interface that enables surface passivation despite large volume changes during cycling. Thin polymer layers (75 nm) improve average first cycle coulombic efficiency from 62.4% in bare silicon electrodes to 76.3%. Average first cycle reversible capacity was improved from 3157 to 3935 mAh g -1 , and average irreversible capacity was reduced from 2011 to 1020 mAh g -1 . Electrochemical impedance spectroscopy performed on silicon electrodes showed that resistance from solid electrolyte interface formation increased from 79 to 1508 Ω in untreated silicon thin films over 26 cycles, while resistance growth was lower – from 98 to 498 Ω – in silicon films functionalized with PMMA brushes. The lower increase suggests enhanced surface passivation and lower electrolyte degradation. This work provides a pathway to develop artificial solid electrolyte interfaces synthesized under controlled reaction conditions.

36 MATERIALS SCIENCE↗

Changes in Hydrogen Concentration and Defect State Density at the Poly-Si/SiOx/c-Si Interface Due to Firing

We determined the density of defect states of poly-Si/SiOx/c-Si junctions featuring a wet chemical interfacial oxide from lifetime measurements using the MarcoPOLO model to calculate recombination and contact resistance in poly-Si/SiOx/c-Si-junctions. In samples that did not receive any hydrogen treatment, the Dit,cSi is about 2 × 1012 cm-2 eV1 before firing and rises to 3–7 × 1012 cm2 eV1 during firing at measured peak temperatures between 620 °C and 863 °C. To address the question of why AlOx/SiNy stacks in contrast to pure SiNy layers for hydrogenation during firing provides better passivation quality, we have measured the hydrogen concentrations at the poly-Si/SiOx/c-Si interface as a function of AlOx layer thickness and compared these to J0 and calculated Dit,c-Si values. We observe an increase of the hydrogen concentration at the SiOx/c-Si interface upon firing as a function of the firing temperature that exceeds the defect concentrations at the interface several times. However, the AlOx layer thickness appears to cause an increase in hydrogen concentration at the SiOx/c-Si interface in these samples rather than exhibiting a hydrogen blocking property.

41 EE - Solar Energy Technologies Office (EE-4S)↗

The Calipso Thermal Control Subsystem

The Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO) is a joint NASA-CNES mission to study the Earth s cloud and aerosol layers. The satellite is composed of a primary payload (built by Ball Aerospace) and a spacecraft platform bus (PROTEUS, built by Alcatel Alenia Space). The thermal control subsystem (TCS) for the CALIPSO satellite is a passive design utilizing radiators, multi-layer insulation (MLI) blankets, and both operational and survival surface heaters. The most temperature sensitive component within the satellite is the laser system. During thermal vacuum testing of the integrated satellite, the laser system s operational heaters were found to be inadequate in maintaining the lasers required set point. In response, a solution utilizing the laser system s survival heaters to augment the operational heaters was developed with collaboration between NASA, CNES, Ball Aerospace, and Alcatel-Alenia. The CALIPSO satellite launched from Vandenberg Air Force Base in California on April 26th, 2006. Evaluation of both the platform and payload thermal control systems show they are performing as expected and maintaining the critical elements of the satellite within acceptable limits.

Gasbarre, Joseph F.↗

The CALIPSO Integrated Thermal Control Subsystem

The Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO) is a joint NASA-CNES mission to study the Earth's cloud and aerosol layers. The satellite is composed of a primary payload (built by Ball Aerospace) and a spacecraft platform bus (PROTEUS, built by Alcatel Alenia Space). The thermal control subsystem (TCS) for the CALIPSO satellite is a passive design utilizing radiators, multi-layer insulation (MLI) blankets, and both operational and survival surface heaters. The most temperature sensitive component within the satellite is the laser system. During thermal vacuum testing of the integrated satellite, the laser system's operational heaters were found to be inadequate in maintaining the lasers required set point. In response, a solution utilizing the laser system's survival heaters to augment the operational heaters was developed with collaboration between NASA, CNES, Ball Aerospace, and Alcatel-Alenia. The CALIPSO satellite launched from Vandenberg Air Force Base in California on April 26th, 2006. Evaluation of both the platform and payload thermal control systems show they are performing as expected and maintaining the critical elements of the satellite within acceptable limits.

Gasbarre, Joseph F.↗

Virtual electrodes for high-density electrode arrays

The present embodiments are directed to implantable electrode arrays having virtual electrodes. The virtual electrodes may improve the resolution of the implantable electrode array without the burden of corresponding complexity of electronic circuitry and wiring. In a particular embodiment, a virtual electrode may include one or more passive elements to help steer current to a specific location between the active electrodes. For example, a passive element may be a metalized layer on a substrate that is adjacent to, but not directly connected to an active electrode. In certain embodiments, an active electrode may be directly coupled to a power source via a conductive connection. Beneficially, the passive elements may help to increase the overall resolution of the implantable array by providing additional stimulation points without requiring additional wiring or driver circuitry for the passive elements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Virtual electrodes for high-density electrode arrays

The present embodiments are directed to implantable electrode arrays having virtual electrodes. The virtual electrodes may improve the resolution of the implantable electrode array without the burden of corresponding complexity of electronic circuitry and wiring. In a particular embodiment, a virtual electrode may include one or more passive elements to help steer current to a specific location between the active electrodes. For example, a passive element may be a metalized layer on a substrate that is adjacent to, but not directly connected to an active electrode. In certain embodiments, an active electrode may be directly coupled to a power source via a conductive connection. Beneficially, the passive elements may help to increase the overall resolution of the implantable array by providing additional stimulation points without requiring additional wiring or driver circuitry for the passive elements.

42 ENGINEERING↗

Passivated Tunneling Contacts to N-Type Wafer Silicon and Their Implementation into High Performance Solar Cells: Preprint

We present a case that passivated contacts based on a thin tunneling oxide layer, combined with a transport layer with properly selected work function and band offsets, can lead to high efficiency c-Si solar cells. Passivated contacts contribute to cell efficiency as well as design flexibility, process robustness, and a simplified process flow. Material choices for the transport layer are examined, including transparent n-type oxides and n+-doped poly-Si. SiO2/n+-poly-Si full-area, induced-junction back surface field contacts to n-FZ and n-Cz Si are incorporated into high efficiency cells with deep, passivated boron emitters.

14 SOLAR ENERGY↗

Passive control of supersonic asymmetric vortical flows around cones

The unsteady, compressible, thin-layer Navier-Stokes equations are used to numerically study the passive control of steady and unsteady supersonic asymmetric flows around circular and noncircular cones. The main computational scheme of the present study is an implicit upwind, flux-difference splitting, finite-volume scheme. Passive control of flow asymmetry is studied by using a vertical fin in the leeward plane of geometric symmetry and side strakes with and without thickness at different orientations. The study focuses on circular-section cones since they are the most likely section-shapes for strong flow asymmetry. Side-strake passive control is shown to be more efficient and practical than vertical-fin passive control.

Liu, C. H.↗

Ground-based temperature and humidity profiling: combining active and passive remote sensors

Abstract. Thermodynamic profiles in the planetary boundary layer (PBL) are important observations for a range of atmospheric research and operational needs. These profiles can be retrieved from passively sensed spectral infrared (IR) or microwave (MW) radiance observations or can be more directly measured by active remote sensors such as water vapor differential absorption lidars (DIALs). This paper explores the synergy of combining ground-based IR, MW, and DIAL observations using an optimal-estimation retrieval framework, quantifying the reduction in the uncertainty in the retrieved profiles and the increase in information content as additional observations are added to IR-only and MW-only retrievals. This study uses ground-based observations collected during the Perdigão field campaign in central Portugal in 2017 and during the DIAL demonstration campaign at the Atmospheric Radiation Measurement Southern Great Plains site in 2017. The results show that the information content in both temperature and water vapor is higher for the IR instrument relative to the MW instrument (thereby resulting in smaller uncertainties) and that the combined IR + MW retrieval is very similar to the IR-only retrieval below 1.5 km. However, including the partial profile of water vapor observed by the DIAL increases the information content in the combined IR + DIAL and MW + DIAL water vapor retrievals substantially, with the exact impact vertically depending on the characteristics of the DIAL instrument itself. Furthermore, there is a slight increase in the information content in the retrieved temperature profile using the IR + DIAL relative to the IR-only; this was not observed in the MW + DIAL retrieval.

54 ENVIRONMENTAL SCIENCES↗

Performance of $\text{BDX-MINI}$ veto systems

Here this paper describes the veto system of the BDX-MINI detector installed at Jefferson Lab (US). The BDX-MINI experiment is the first electron beam-dump experiment specifically designed to search for Light Dark Matter (LDM) particles in the MeV-GeV mass range. The core of the BDX-MINI detector is a lead-tungstate electromagnetic calorimeter, for a total volume of 4 dm 3 . The calorimeter is surrounded by a multi-layer veto aimed at rejecting cosmic background: the innermost layer of the veto is made by a passive tungsten shielding for low energy radiation, while plastic scintillators make the middle and outer layers for charged cosmic particles rejection. Being located about 20 m downstream, the dirt between the beam dump and the detector provides sufficient shielding from the beam-related background. In 2019–2020, BDX-MINI was exposed for about six months to weakly interacting particles (neutrinos and, if existing, DM) produced by a 2.176 GeV electron beam incident on the beam dump of experimental Hall-A at Jefferson Lab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗