Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical detectability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Detection of radio-frequency modulated optical signals by two and three terminal microwave devices

An interdigitated photoconductor (two terminal device) on GaAlAs/GaAs heterostructure was fabricated and tested by an electro-optical sampling technique. Further, the photoresponse of GaAlAs/GaAs HEMT (three terminal device) was obtained by illuminating the device with an optical signal modulated up to 8 GHz. Gain-bandwidth product, response time, and noise properties of photoconductor and HEMT devices were obtained. Monolithic integration of these photodetectors with GaAs microwave devices for optically controlled phased array antenna applications is discussed.

Bhasin, K. B.↗

Detection of radio-frequency modulated optical signals by two and three terminal microwave devices

An interdigitated photoconductor (two terminal device) on GaAlAs/GaAs heterostructure was fabricated and tested by an electro-optical sampling technique. Further, the photoresponse of GaAlAs/GaAs HEMT (three terminal device) was obtained by illuminating the device with an optical signal modulated up to 8 GHz. Gain-bandwidth product, response time, and noise properties of photoconductor and HEMT devices were obtained. Monolithic integration of these photodetectors with GaAs microwave devices for optically controlled phased array antenna applications is discussed.

Bhasin, K. B.↗

Application of super smooth optics to extra-solar planet detection

The observational constraints on direct detection of extrasolar planets around nearby stars are defined. The design of an instrument capable of meeting these goals requires the efficient reduction of diffracted and scattered light by about three orders of magnitude below the airy wings of the unapodized aperture. The diffraction reduction is achieved through the high-efficiency coronagraph, which uses Gaussian occulting masks in the first focus to concentrate better diffracted light in the pupil plane. Laboratory experiments confirm this high efficiency to the limits set by the experimental setup. Scattering due to midspatial scale figure error in the mirrors must also be reduced to a comparable level.

Terrile, Richard J.↗

Detecting X-rays with an optical imaging chamber

The light emitted by electron avalanches in a parallel plate chamber can be used to image the tracks of photoelectrons liberated by the interaction of an incident X-ray with the gas filling the chamber. The different morphologies of photoelectron tracks and minimum ionizing tracks can be used for charged particle rejection. The initial direction (before scattering) of the liberated photoelectron also contains information about the polarization of the incident radiation. We have built a small test chamber with which we have imaged photoelectron tracks using an intensified CCD camera. Our results show that optical imaging could be used in a hard X-ray imaging polarimeter useful for astronomy.

Austin, Robert A.↗

Optical techniques for shock visualization and detection

While the classical methods of shadowgraph and schlieren do yield a shadow in the neighborhood of a shock, they often suffer from low power densities and the need for relatively long distances. Scanning methods may help in solving these problems. The paper describes various scanning techniques, presents experimental data obtained by mechanical scanning, and identifies conditions at which the data were taken.

Adamovsky, G.↗

Detection Performance of Upgraded "Polished Panel" Optical Receiver Concept on the Deep-Space Network's 34 Meter Research Antenna

Initial optical communications experiments with a Vertex polished aluminum panel have been described. The polished panel was mounted on the main reflector of the DSN's research antenna at DSS-13. The PSF was recorded via remotely controlled digital camera mounted on the subreflector structure. Initial PSF generated by Jupiter showed significant tilt error and some mechanical deformation. After upgrades, the PSF improved significantly, leading to much better concentration of light. Communications performance of the initial and upgraded panel structure were compared. After the upgrades, simulated PPM symbol error probability decreased by six orders of magnitude. Work is continuing to demonstrate closed-loop tracking of sources from zenith to horizon, and better characterize communications performance in realistic daytime background environments.

polished panel optical receiver↗

OTD Observations of Continental US Ground Flashes Detected by NLDN

Lightning optical flash parameters (e.g., radiance, area, duration, number of optical groups, and number of optical events) derived from almost 5 yrs of Optical Transient Detector (OTD) data are compared with peak current and multiplicity observations derived from the US National Lightning Detection Networkm (NLDN). Despite the relatively low lightning geolocation accuracy afforded by OTD, a total of 48,870 NLDN cloud-to-ground (CG) flashes were correlated with OTD flashes, or about 10,000 CGs per year. The median values of the above OTD flash parameters for the 48,870 CGs were, respectively: 0.137 J/square meters/sr/micrometers, 313.7 square kilometers, 0.189 s, 4 optical groups per CG, and 8 optical events per CG. Invoking the multiplicity data, the median number of optical groups per stroke was 2.5, and the median number of optical events per stroke was 5.0. Median values of peak current for negative and positive CGs were -21.6 kA and 17.8 kA, respectively, and as expected, the negative CGs had a larger average multiplicity than the positive CGs. A statistical summary is provided for all CGs, for positive and negative CGs, and for CGs from different seasons. Standard two-distribution hypothesis tests were perfonned to intercompare the population means of the various lightning parameters. In particular, and to greater than the 99% confidence level, it was found that positive CGs are on average more radiant, of greater areal extent, and are longer lasting than negative CGs. Rankings from a complete set of hypothesis tests between CGs of different polarities and from different seasons are also provided. Most notably, wintertime positive CGs tend to be more radiant, of greater areal extent, and longer lasting than any other group of CGs (i.e., negative springtime CGs, positive summertime CGs, etc.).

Koshak, William J.↗

Two-Photon Flow Cytometry

Flow cytometry is a powerful technique for obtaining quantitative information from fluorescence in cells. Quantitation is achieved by assuring a high degree of uniformity in the optical excitation and detection, generally by using a highly controlled flow such as is obtained via hydrodynamic focusing. In this work, we demonstrate a two-beam, two- channel detection and two-photon excitation flow cytometry (T(sup 3)FC) system that enables multi-dye analysis to be performed very simply, with greatly relaxed requirements on the fluid flow. Two-photon excitation using a femtosecond near-infrared (NIR) laser has the advantages that it enables simultaneous excitation of multiple dyes and achieves very high signal-to-noise ratio through simplified filtering and fluorescence background reduction. By matching the excitation volume to the size of a cell, single-cell detection is ensured. Labeling of cells by targeted nanoparticles with multiple fluorophores enables normalization of the fluorescence signal and thus ratiometric measurements under nonuniform excitation. Quantitative size measurements can also be done even under conditions of nonuniform flow via a two-beam layout. This innovative detection scheme not only considerably simplifies the fluid flow system and the excitation and collection optics, it opens the way to quantitative cytometry in simple and compact microfluidics systems, or in vivo. Real-time detection of fluorescent microbeads in the vasculature of mouse ear demonstrates the ability to do flow cytometry in vivo. The conditions required to perform quantitative in vivo cytometry on labeled cells will be presented.

Zhog, Cheng Frank↗

Hydrogen Detection via a Low-Cost Prototype Fiber-Optic Sensing System

The developed low-cost prototype sensing system successfully detects hydrogen concentrations across a wide range, demonstrating immediate feasibility for commercial deployment. Utilizing fiber-optic technology, the system delivers stable, reproducible performance from parts-per-million levels up to 100% pure H2 environments. Environmental and chemical cross-sensitivity evaluations confirm robust selectivity against methane and temperature changes, establishing its readiness for near-term commercialization.

fiber-optic H2 sensor↗

A Robust Vision-Based Algorithm for Detecting and Classifying Small Orbital Debris Using On-Board Optical Cameras

This study develops a vision-based detection and classification algorithm to address the challenges of in-situ small orbital debris environment classification including debris observability and instrument requirements for small debris observation. The algorithm operates in near real time and is robust under difficult tasks in moving objects classification such as multiple moving objects, objects with various movement trajectories and speeds, very small or faint objects, and substantial background motion. The performance of the algorithm is optimized and validated using space image data available through simulated environments generated using NASA Marshall Space Flight Centers Dynamic Star Field Simulator of on-board optical sensors and cameras.

Zamani, Yasin↗

Inertial navigation sensor integrated obstacle detection system

A system that incorporates inertial sensor information into optical flow computations to detect obstacles and to provide alternative navigational paths free from obstacles. The system is a maximally passive obstacle detection system that makes selective use of an active sensor. The active detection typically utilizes a laser. Passive sensor suite includes binocular stereo, motion stereo and variable fields-of-view. Optical flow computations involve extraction, derotation and matching of interest points from sequential frames of imagery, for range interpolation of the sensed scene, which in turn provides obstacle information for purposes of safe navigation.

Bhanu, Bir↗

Insect-Inspired Optical-Flow Navigation Sensors

Integrated circuits that exploit optical flow to sense motions of computer mice on or near surfaces ( optical mouse chips ) are used as navigation sensors in a class of small flying robots now undergoing development for potential use in such applications as exploration, search, and surveillance. The basic principles of these robots were described briefly in Insect-Inspired Flight Control for Small Flying Robots (NPO-30545), NASA Tech Briefs, Vol. 29, No. 1 (January 2005), page 61. To recapitulate from the cited prior article: The concept of optical flow can be defined, loosely, as the use of texture in images as a source of motion cues. The flight-control and navigation systems of these robots are inspired largely by the designs and functions of the vision systems and brains of insects, which have been demonstrated to utilize optical flow (as detected by their eyes and brains) resulting from their own motions in the environment. Optical flow has been shown to be very effective as a means of avoiding obstacles and controlling speeds and altitudes in robotic navigation. Prior systems used in experiments on navigating by means of optical flow have involved the use of panoramic optics, high-resolution image sensors, and programmable imagedata- processing computers.

Thakoor, Sarita↗

First Time-Resolved Leader Spectra Associated With a Downward Terrestrial Gamma-Ray Flash Detected at the Telescope Array Surface Detector

Optical emissions associated with Terrestrial Gamma ray Flashes (TGFs) have recently become important subjects in space-based and ground-based observations as they can help us understand how TGFs are produced during thunderstorms. In this paper, we present the first time-resolved leader spectra of the optical component associated with a downward TGF. The TGF was observed by the Telescope Array Surface Detector (TASD) simultaneously with other lightning detectors, including a Lightning Mapping Array (LMA), an INTerFerometer (INTF), a Fast Antenna (FA), and a spectroscopic system. The spectroscopic system recorded leader spectra at 29,900 frames per second (33.44 μs time resolution), covering a spectral range from 400 to 900 nm, with 2.1 nm per pixel. The recordings of the leader spectra began 11.7 ms before the -18 kA return stroke and at a height of 2.37 km above the ground. These spectra reveal that optical emissions of singly ionized nitrogen and oxygen occur between 167 μs before and 267 μs after the TGF detection, while optical emissions of neutrals (H I, 656 nm; N I, 744 nm, and O I, 777 nm) occur right at the moment of the detection. The time-dependent spectra reveal differences in the optical emissions of lightning leaders with and without downward TGFs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Systematic aspects of direct extrasolar planet detection

Using the first optical observatory in space, the Hubble Space Telescope, images of possible extrasolar planets will have poor contrast against the background of diffracted and scattered starlight. The very long exposure time required to achieve an adequate signal-to-noise ratio will make their detection infeasible. For a future telescope, a 16-fold increase in either the smoothness of the collecting area of the optics would reduce the exposure time to a tolerable value, but the contrast would remain low and the required photometric precision high. In this situation, the feasibility of detection would be contingent on the careful identification and control of systematic errors.

Brown, Robert A.↗