Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple solutions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Instantaneous mesh load factor ( K γ ) measurements in a wind turbine gearbox using fiber-optic strain sensors

The mesh load factor, K γ , describes how loads are shared between planet gears and has become one of the key design challenges in modern wind turbine gearboxes. Planet load sharing directly impacts tooth root stresses, a critical driver of torque density and gearbox reliability. Experimental evaluation of K γ is typically performed from sun gear tooth root strain gauge measurements, which are complex. Furthermore, such measurements can only provide an average value of load sharing. The present study describes an alternative method to evaluate the mesh load factor in wind turbine gearboxes based on fiber-optic strain sensors installed on the outer surface of the fixed ring gear. We present the results of an extensive measurement campaign to evaluate this novel sensing solution installed on the input planetary stage of a 2-MW wind turbine gearbox at the National Renewable Energy Laboratory's Flatirons Campus (Colorado, USA). The number of strain sensors on the ring gear was selected as an integer multiple of the number of planets, which has enabled an instantaneous evaluation of the mesh load factor. The effect of operating conditions on the planet load-sharing behavior of the gearbox has been investigated. The mesh load factor measured for operating conditions close to rated was below 1.05, well below IEC 61400-4 standard requirements.

17 WIND ENERGY↗

Atomic structures determined from digitally defined nanocrystalline regions

Nanocrystallography has transformed our ability to interrogate the atomic structures of proteins, peptides, organic molecules and materials. By probing atomic level details in ordered sub-10 nm regions of nanocrystals, scanning nanobeam electron diffraction extends the reach of nanocrystallography and in principle obviates the need for diffraction from large portions of one or more crystals. Scanning nanobeam electron diffraction is now applied to determine atomic structures from digitally defined regions of beam-sensitive peptide nanocrystals. Using a direct electron detector, thousands of sparse diffraction patterns over multiple orientations of a given crystal are recorded. Each pattern is assigned to a specific location on a single nanocrystal with axial, lateral and angular coordinates. This approach yields a collection of patterns that represent a tilt series across an angular wedge of reciprocal space: a scanning nanobeam diffraction tomogram. Using this diffraction tomogram, intensities can be digitally extracted from any desired region of a scan in real or diffraction space, exclusive of all other scanned points. Intensities from multiple regions of a crystal or from multiple crystals can be merged to increase data completeness and mitigate missing wedges. It is demonstrated that merged intensities from digitally defined regions of two crystals of a segment from the OsPYL/RCAR5 protein produce fragment-based ab initio solutions that can be refined to atomic resolution, analogous to structures determined by selected-area electron diffraction. In allowing atomic structures to now be determined from digitally outlined regions of a nanocrystal, scanning nanobeam diffraction tomography breaks new ground in nanocrystallography.

36 MATERIALS SCIENCE↗

Development of a Hardware-in-The-Loop Testbed for a Decentralized, Data-Driven Electric Vehicle Charging Control Algorithm

This study presents the design of an electric vehicle (EV)-grid integration (EVGI) hardware test-bed to implement smart EV charging algorithms. Here, the proposed test-bed also allows to create different grid events via flexible integration of other power hardware (e.g., controllable loads and battery energy storage systems) and test their impacts on EV charging. The design uses a real-time digital simulator to realize a complex distribution grid model with primary and secondary networks. A grid simulator physically realizes the selected nodes of the simulated grid to power an actual EV, forming a hardware-in-the-loop (HIL) test setup. The EV-grid integration is demonstrated based on the custom hardware and software implementation of the J1772 charging protocol using dSPACE MicroLabBox, operating as a custom EV Supply Equipment (EVSE). The HIL test-bed features a novel testing platform for accurate implementation and analysis of scalable charging algorithms. To this end, a data-driven, decentralized, model-free charging controller based on the Additive Increase and Multiplicative Decrease (AIMD) algorithm is presented and validated on an EV using the HIL test-bed. We tested the proposed algorithm under various case studies, and presented a comparison study with an existing droop-based, decentralized charging solution. The results showed that the EV successfully performed charging commands generated by the EVSE and regulated its charging power to effectively reduce the system loading caused by high EV penetration.

33 ADVANCED PROPULSION SYSTEMS↗

Battery Lifecycle Framework

The Battery Lifecycle (BLC) Framework is an open-source platform that provides tools to visualize and share battery data from material characterization, cell testing, manufacturing, and field testing through the technology development cycle. BLC has three components: data importers, a front-end for querying the data and creating visualizations, and an application programming interface to provide access to the data from Python. BLC has been deployed for tracking the development of a battery from the lab to a manufacturing line and systems installed in the field and for comparing studies of multiple cells of the same battery chemistry and configuration. The code was developed around Redash, a robust open-source extract-transform-load engine. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-4546 O

De Angelis, Valerio↗

Enhancing the performance of solvent-borne poly(ethyl methacrylate) coatings for high-power laser applications via low-temperature drying

Organic polymers are a versatile class of materials employed in a broad range of optical coating applications. However, their use as coatings in high-power laser applications, particularly in the UV spectral region, has been limited in scope due to their relatively low laser-induced damage thresholds (LIDTs), which decrease further with exposure to multiple pulses. This study explores the effect of post-deposition drying temperature and residual solvent on the LIDT of solvent-borne polymer coatings. In this work, poly(ethyl methacrylate) (PEMA) coatings were deposited by first spin coating solutions of PEMA (dissolved in 2,2,2-trichloroethanol (TCE)) onto fused silica substrates, then baking at temperatures of either 130°C (soft-bake) or 180°C (hard-bake). Analysis of the two coatings revealed that the soft-bake coating retained a significant amount of TCE within the polymer matrix, which functioned to plasticize the coating and reduce internal stress. The laser-induced damage resistance of the two coatings was evaluated using 351-nm, 1-ns laser pulses. The testing protocols included single-pulse (1-on-1), 1-pulse ramp (R-on-1), and a 1000-pulse ramp (1000R-on-1) test. The results showed that the plasticized, soft-bake coating exhibits a significantly increased LIDT, especially for multipulse irradiation conditions.

36 MATERIALS SCIENCE↗

Connected Communities: A Multi-Building Energy Management Approach

Connected Communities (CCs) are collections of buildings and distributed energy resources (DERs) that incorporate integrated energy management strategies at the multi-building scale. Based on the research conducted for this report, RMI and NREL have identified examples of CCs that are enabling increasingly integrated solutions, sharing resources among buildings, and providing services back to the grid. As demonstrated by these examples, CCs can provide real and scalable solutions to mitigate energy costs, enable more flexibility in grid operations, and offer choices in meeting greenhouse gas (GHG) emissions goals. Nationwide examples of these solutions are included in the appendix of this report. In order to understand the most promising practices for the design, operation, and business models associated with CCs, a search was performed to create a nationwide inventory of CCs and multiple stakeholder interviews were conducted. Based on that research, this paper explores the many factors that influence the development and operation of CCs and evaluates their potential value.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FY22 Status Report on the ART-GCR CMVB and CNWG International Collaborations

This work presents the numerical model for the high temperature test reactor (HTTR) loss of forced cooling (LOFC) experiment with the INL codes Griffin, BISON, and RELAP-7, based on the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Promising results were obtained, with the overall behavior of the reactor successfully captured. Changes in the heat transfer coupling, as compared to the fiscal year (FY)-21 model, enabled drastic improvement of the steady-state solution, both in terms of computational time and global energy discrepancies. The former was reduced by a factor of roughly 60, whereas the latter decreased from 11% to less than 2%. Furthermore, the discrepancy in the steady-state multiplication factor was improved from +2,300 and +2,900 pcm (for the 30 and 9 MW cases) to -700 and +1,200 pcm, respectively, and now falls well within the large measurement uncertainties stemming from graphite impurities. Validation of the Monte Carlo model used to generate cross sections was also performed against available measurements. Though significant, the discrepancies remain acceptable overall in light of the large uncertainty. Numerous improvements are still needed to better compare with the experiment involving the 9 MW case and to instill greater confidence in the model’s ability to accurately predict the 30 MW behavior. Specifically, the power levels predicted by the 9 MW transient simulation following re-criticality remain low, pointing to an underestimation of the passive cooling of the core. A key aspect of future work will be to better understand the flow pattern during the LOFC event, particularly to determine if natural or forced convection is occurring inside the reactor pressure vessel (RPV). More generally, additional validation data would be immensely useful for further enhancing the numerical model and better matching the experiments. In addition, a more sophisticated thermal-hydraulics model that simulates all the channels as a single system model should be considered to take into account the rest of the primary loop. Finally, even if the results are in better agreement with the experiments, sensitivity analysis and uncertainty quantification will be necessary to evaluate the model uncertainty.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modeling Material Interfaces with the Six-Equation Model in FLEXO

FLEXO is a multiphysics code developed at Sandia National Laboratories for predictive simulation of pulsed power target physics with extended magnetohydrodynamics modeling. Given this application space, FLEXO must be able to perform high-fidelity simulations of pulsed-power systems that include multiple materials. This work presents the augmentation of FLEXO with a six-equation model for multimaterial flow. We design and analyze discretizations of the six-equation model, emphasizing desirable properties for robust multimaterial simulation. We also present solution limiting, bounds preservation, and pressure equilibration/relaxation techniques that enhance the robustness of the overall multimaterial scheme. We present a suite of test problems to document these new capabilities of the FLEXO code.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of the Sulfur-Saturated Melt Versions of the LAW Phase 4 Glasses

In this report, results are provided from the analyses of a series of sulfur-saturated melt versions of simulated nuclear waste glasses, and chemical analysis of the wash solution resulting from the preparation of these glasses. The glasses were selected and fabricated by the Pacific Northwest National Laboratory as part of a broader study of the influence of glass composition on chemical durability, sulfur retention, and other properties. The resulting data will be used in the development of enhanced property/composition models for waste vitrification at Hanford. Chemical analyses were performed on a representative sample of each of the sulfur-saturated versions of the quenched glasses to allow for comparisons with the targeted compositions, as well as the measured compositions of the quenched glasses. The measured concentrations of chlorine, and fluorine were below the targeted values for most of the study glasses, likely because of volatility during the multiple melting steps. The measured concentrations of B 2 O 3 , K 2 0, and Li 2 0 were generally low relative to the targeted values. As expected, the measured concentrations of SO 3 in most of the glasses were higher than targeted due to the use of the sulfur saturation method in fabricating these glasses. The wash solutions contained mainly sodium and sulfur, with moderate concentrations of potassium.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New capabilities for rapid depletion analysis of pebble-bed reactors in SCALE

The SCALE Leap-In for Cores at Equilibrium (SLICE) method leverages capabilities available in the SCALE modeling and simulation suite to facilitate rapid estimation of equilibrium core inventories for flowing-pebble reactor systems in support of a variety of fuel cycle applications. New capabilities that compliment the SLICE method have been developed for the ORIGAMI interface to ORIGEN in SCALE to facilitate rapid depletion calculations for flowing-pebble systems. New features include a more generalized and flexible means of specifying interpolation dimensions, the ability to evaluate pebbles moving through user-defined “axial zones” in each of the pebble’s multiple passes through the core, and the treatment of differential velocities across radial channels (representing both pebble-to-pebble and wall-to-pebble friction effects). ORIGAMI thus provides an efficient user interface to define a pebble’s path and irradiation histories of its multiple passes through the core to calculate the pebble’s time-dependent inventories, which can be useful in various applications domains such as safeguards, criticality safety, and disposal analyses. The consistency of new ORIGAMI approach was verified against the solution obtained using the SLICE method with ORIGEN-ARP, showing excellent agreement.

Skutnik, Steven E. [Oak Ridge National Laboratory ↗

Air quality and comfort constrained energy efficient operation of multi-zone buildings

Maintaining indoor air quality (IAQ) through effective ventilation is essential for the well-being and productivity of building occupants. Control strategies aimed at improving the efficiency of heating, ventilation and air conditioning (HVAC) systems must jointly determine ventilation and heating and cooling processes. Here, in this paper, we study the problem of minimizing the energy consumption of the HVAC system in a multi-zone building, while meeting thermal comfort and IAQ requirements. We first perform a steady state analysis of the zonal carbon dioxide (CO 2 ) concentration and the temperature dynamics. The resulting expressions are convex in the zonal mass flow rates and zonal temperatures. Guided by the steady state solutions for meeting the thermal comfort constraints, we develop two control policies for improving the energy efficiency of building HVAC systems while jointly satisfying indoor temperature and IAQ constraints. We compare the performance of our proposed approaches with those of multiple baseline approaches which implement separate regimes for controlling zonal temperature and IAQ for a typical work-day in a multi-zone campus building. We have evaluated the performance of our proposed approaches under varying levels of flexibility in zonal temperatures. We have shown that zonal temperature flexibility can result in energy savings up to 32% (for the same control strategies) as compared to the case where no such flexibility is permitted. Our proposed approaches were seen to offer potential savings of nearly 29% compared to the baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PRIME

SAND2021-0565 O PRIME is a modeling framework designed for the real-time characterization and forecasting of partially observed epidemics. The method is designed to help guide medical resource allocation in the early epoch of the outbreak. Characterization is the estimation of infection spread parameters using daily counts of symptomatic patients. The estimation problem is posed as one of Bayesian inference and solved using a Markov Chain Monte Carlo technique. The framework can accommodate multiple epidemic waves and can help identify different disease dynamics at the regional, state, and country levels. Examples are provided using publicly available COVID-19 data. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Safta, Cosmin↗

Spack-Manager

SAND2022-3282 O Spack-Manager is a lightweight wrapper for streamlining the software development and deployment cycle using Spack. Spack-Manager creates a uniform framework for developing, testing, and deploying specific software stacks for projects across multiple platforms while utilizing Spack as much as possible. It organizes Spack extensions, machine configurations, project customizations, and tools for features that are mostly project specific. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Sakievich, Philip↗

Near-Optimal Performance of Stochastic Model Predictive Control

Here, this article presents a regret analysis for stochastic model predictive control (SMPC) in linear systems with quadratic performance index and additive and multiplicative uncertainties. Under a finite support assumption, the problem can be cast as a finite-dimensional quadratic program, but the problem becomes quickly intractable as the problem size grows exponentially in the horizon length. SMPC aims to compute approximate solutions by solving a sequence of problems with truncated prediction horizons and committing the solution in a receding-horizon fashion. Although this approach is widely used in practice, its performance relative to the optimal solution is not well understood. This article reports for the first time a rigorous near-optimal performance guarantee of SMPC: under stabilizability and detectability conditions, the regret of SMPC is exponentially small in the prediction horizon length, allowing SMPC to achieve near-optimal performance at a substantially reduced computational expense.

93E20, 93B45↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Space-Time Reduced-Order Modeling for Uncertainty Quantification

This work focuses on the space-time reduced-order modeling (ROM) method for solving large-scale uncertainty quantification (UQ) problems with multiple random coefficients. In contrast with the traditional space ROM approach, which performs dimension reduction in the spatial dimension, the space-time ROM approach performs dimension reduction on both the spatial and temporal domains, and thus enables accurate approximate solutions at a low cost. We incorporate the space-time ROM strategy with various classical stochastic UQ propagation methods such as stochastic Galerkin and Monte Carlo. Numerical results demonstrate that our methodology has significant computational advantages compared to state-of-the-art ROM approaches. By testing the approximation errors, we show that there is no obvious loss of simulation accuracy for space-time ROM given its high computational efficiency.

97 MATHEMATICS AND COMPUTING↗

ReEDS Performance Improvement

The Regional Energy Deployment System (ReEDS) is an open-source, spatially explicit, long-term capacity expansion model for the bulk electric power system of the contiguous United States, encompassing multiple scenarios with technological and political assumptions (see https://github.com/NREL/ReEDS-2.0). With the increased needs for capabilities, higher temporal and spatial resolutions to model the evolution of the power system with modern technologies and low-carbon pathways, ReEDS' model solution times have increased significantly from 4-6 hours in 2018 to 18-48+ hours in 2023 . Also, the model size for commonly-run ReEDS scenarios reached 22 and 28 million equations and variables, respectively. These runtimes can be especially challenging under certain scenario settings (e.g., very high temporal or spatial resolution) or with limited computational power. In this presentation, we will discuss several methods we used to improve model runtime, including data preparation, model modification, and solver tuning. The implementation of these methods shrank the model size to 7.2 and 7.3 million equations and variables, respectively. Furthermore, this led to a 77% reduction in the model's run time for commonly-run ReEDS scenarios. We will discuss the process of identifying areas for solve time improvements and how the specific enhancements for the ReEDS model might be applied to other similar large-scale models.

ENERGY PLANNING, POLICY, AND ECONOMY,MATHEMATICS A↗

The future of subsurface monitoring: AEC’s breakthroughs in CCS technology

Carbon capture and storage (CCS) has emerged as a key solution in the fight against climate change. However, for CCS to succeed, it is crucial to ensure that the sequestered CO2 stays safely trapped underground. The U.S. Department of Energy (DOE) has emphasized the need for advancements in subsurface monitoring, measurement, reporting, and verification. Aside from caprock integrity failure, the other primary failure points usually involve defective cement in the casing annulus of wellbores or plugged and abandoned wells. In addition, many energy producers (e.g., oil and gas, geothermal) and storage and disposal operators (e.g., H2 and water) must deal with the same issue. Poorly placed or degraded cement can create pathways for gas or fluid to escape from casing annuli and in plugged and abandoned or orphan wells, posing environmental risks. Yet, a reliable and cost-effective way to monitor cement and well integrity over multiple decades is still unavailable. Traditional geophysical methods like 4D seismic imaging and surface-based electromagnetic monitoring lack the resolution and accuracy for detecting these types of failures (Vasco et al., 2022; Fawad and Mondol, 2021). Wireline logging is expensive to run continuously and is obtrusive to the operation. While fiber optics can potentially be a solution, its bulkiness can significantly compromise the cement's integrity. To address these challenges, the Advanced Energy Consortium (AEC) at The University of Texas at Austin’s Bureau of Economic Geology (the Bureau) has been pioneering research in subsurface monitoring using its portfolio of distributed autonomous microfabricated sensors for harsh subsurface environments since 2008. A class of these microsensors [System on a Chip (SoC)] can be mixed in cement and permanently placed without compromising the cement column; the sensors would then communicate with each other or a data acquisition (DAQ) master node. Another class of the AEC microsensors can be fully autonomous, with rechargeable micro-batteries capable of exceeding 100°C, flash memory, and, currently, a pressure and temperature sensor. They are designed to circulate in mud, geothermal fluids, U-loops, or pipelines. They can log data into memory and are unobtrusive to operations. Our team has been working on a multi-year DOE-funded project (DE-FE0031856)—supported by $2.95M in federal funding and $0.75M in cost-matching from the AEC—to demonstrate SoC sensor utility for CO2 leakage monitoring in CCS applications. This multi-institutional collaboration developed a novel sensing architecture utilizing radiofrequency (RF) microsensors embedded within the cement sheath. These sensors detect CO2 migration and are interrogated via a Smart Casing Collar (SCC).

58 GEOSCIENCES↗