Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Comparison of temporal resolution selection approaches in energy systems models

Capacity expansion models for the power sector are used to project future decisions over the coming decades by simulating investment and operation decisions for the use of electricity. Due to model performance constraints, these models typically do not explicitly simulate every hour within a year, but instead simulate representative time segments (groups of hours). This paper evaluates different approaches for selecting time segments across three methods: sequential, categorical, and clustering, across a wide range of time-segment quantities, for a total of 204 temporal profiles. To measure the performance of each profile's ability to accurately represent data, the root-mean-square-error of each profile's time segments are compared to the data's original hourly data. The temporal alignment across regions is also measured (i.e., how often windy days align across regions). Different spatial resolutions were applied for a subset of the temporal selection methods to investigate the impact spatial resolution has on performance. This paper provides a framework for measuring the value of different temporal selection methods and of adding more granular data to energy system models. Overall, multi-criteria clustering yields the lowest root-mean-square-error across all datasets evaluated and provides a holistic view of the intertwined relationships between renewable generation and electricity demand.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Effective Opacity of the Intergalactic Medium from Galaxy Spectra Analysis

We measure the effective opacity (τ{sub eff}) of the intergalactic medium from the composite spectra of 281 Lyman-break galaxies in the redshift range 2 ≲ z ≲ 3. Our spectra are taken from the COSMOS Lyα Mapping And Tomographic Observations survey derived from the Low Resolution Imaging Spectrometer on the W.M. Keck I telescope. We generate composite spectra in two redshift intervals and fit them with spectral energy distribution (SED) models composed of simple stellar populations. Extrapolating these SED models into the Lyα forest, we measure the effective Lyα opacity (τ{sub eff}) in the 2.02 ≤ z ≤ 2.44 range. At z = 2.22, we estimate τ{sub eff} =0.159±0.001 from a power-law fit to the data. These measurements are consistent with estimates from quasar analyses at z < 2.5 indicating that the systematic errors associated with normalizing quasar continua are not substantial. We provide a Gaussian processes model of our results and previous τ{sub eff} measurements that describes the steep redshift evolution in τ{sub eff} from z = 1.5–4.

79 ASTRONOMY AND ASTROPHYSICS↗

S -factor and scattering-parameter extractions from ${}^{3}\mathrm{He}+{}^{4}\mathrm{He}{ \rightarrow }^{7}\mathrm{Be}+\gamma $

Previous studies of the reaction ${}^{3}\mathrm{He}+{}^{4}\mathrm{He}\to {}^{7}\mathrm{Be}+\gamma $ have mainly focused on providing the best central value and error bar for the S factor at solar energies. Experimental measurements of this capture reaction at higher energies, the ${}^{3}\mathrm{He}$–${}^{4}\mathrm{He}$ scattering phase shifts, as well as properties of ${}^{7}\mathrm{Be}$ and its excited state, have been used to constrain the theoretical models employed for this purpose. Here we show that much more information than was previously appreciated can be extracted from angle-integrated capture data alone. We use the next-to-leading-order (NLO) amplitude in an effective field theory (EFT) for ${}^{3}\mathrm{He}+{}^{4}\mathrm{He}\to {}^{7}\mathrm{Be}+\gamma $ to perform the extrapolation. At this order the EFT describes the capture process using an s-wave scattering length and effective range, the asymptotic properties of ${}^{7}\mathrm{Be}$ and its excited state, and short-distance contributions to the E1 capture amplitude. We extract the multi-dimensional posterior of all these parameters via a Bayesian analysis that uses capture data below 2 MeV. We find that properties of the ${}^{7}\mathrm{Be}$ ground and excited states are well constrained. The total S factor $S(0)\,={0.577}_{-0.016}^{+0.015}$ keV b, while the branching ratio for excited- to ground-state capture at zero energy, ${Br}(0)={0.406}_{-0.011}^{+0.013}$, both at 68% degree of belief. This S(0) is broadly consistent with other recent evaluations, and agrees with the previously recommended value $S(0)=0.56\pm 0.03\,\,\mathrm{keV}$ b, but has a smaller error bar. We also find significant constraints on ${}^{3}\mathrm{He}$–${}^{4}\mathrm{He}$ scattering parameters, and we obtain constraints on the angular distribution of capture gamma rays, which is important for interpreting experiments. The path forward for this reaction seems to lie with better measurements of the scattering phase shifts and S(E)'s angular dependence away from zero energy, together with better understanding of the asymptotic normalization coefficients of the ${}^{7}$Be bound states' wave functions. Lastly, data on these could further reduce the uncertainty on S(0).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Frequency Response Analysis to Monitor and Identify Changes in the Impedance of a Photovoltaic Panel Measured Online using a Power Optimizer

Photovoltaic (PV) cells are generally modeled as a current source due to photocurrent, p-n junction diodes with parasitic resistance, capacitance, and inductance. This paper proposes online frequency response analysis (FRA) to measure the impedance of a PV panel using an existing panel-level power optimizer in a PV system. The algorithm will actively perturb a small signal into a 300 W rooftop PV panel and compute its small signal impedance. The technology discussed is easy to incorporate, requires no additional hardware, doesn't alter the stability of the system, and is implemented at a steady-state point. The power optimizer initially stabilizes at an operating point and then perturbs the PV current via FRA and computes PV panel impedance. The relative standard deviation test conducted indoors under 300 W/m 2 illumination on a PV panel shows a less than 5% error rate in PV panel impedance magnitude and phase is measured using a power optimizer.

14 SOLAR ENERGY↗

Accurate Effective Stress Measures: Predicting Creep Life for 3D Stresses Using 2D and 1D Creep Rupture Simulations and Data

Operating structural components experience complex loading conditions resulting in 3D stress states. Current design practice estimates multiaxial creep rupture life by mapping a general state of stress to a uniaxial creep rupture correlation using effective stress measures. The data supporting the development of effective stress measures are nearly always only uniaxial and biaxial, as 3D creep rupture tests are not widely available. This limitation means current effective stress measures must extrapolate from 2D to 3D stress states, potentially introducing extrapolation error. In this work, we use a physics-based, crystal plasticity finite element model to simulate uniaxial, biaxial, and triaxial creep rupture. Here, we use the virtual dataset to assess the accuracy of current and novel effective stress measures in extrapolating from 2D to 3D stresses and also explore how the predictive accuracy of the effective stress measures might change if experimental 3D rupture data was available. We confirm these conclusions, based on simulation data, against multiaxial creep rupture experimental data for several materials, drawn from the literature. The results of the virtual experiments show that calibrating effective stress measures using triaxial test data would significantly improve accuracy and that some effective stress measures are more accurate than others, particularly for highly triaxial stress states. Results obtained using experimental data confirm the numerical findings and suggest that a unified effective stress measure should include an explicit dependence on the first stress invariant, the maximum tensile principal stress, and the von Mises stress.

36 MATERIALS SCIENCE↗

DESI DR2 results. I. Baryon acoustic oscillations from the Lyman alpha forest

We present the baryon acoustic oscillation (BAO) measurements with the Lyman-𝛼 (Ly⁢𝛼) forest from the second data release (DR2) of the Dark Energy Spectroscopic Instrument (DESI) survey. Our BAO measurements include both the autocorrelation of the Ly⁢𝛼 forest absorption observed in the spectra of high-redshift quasars and the cross-correlation of the absorption with the quasar positions. The total sample size is approximately a factor of 2 larger than the DR1 dataset, with forest measurements in over 820,000 quasar spectra and the positions of over 1.2 million quasars. We describe several significant improvements to our analysis in this paper, and two supporting papers describe improvements to the synthetic datasets that we use for validation and how we identify damped Ly⁢𝛼 absorbers. Our main result is that we have measured the BAO scale with a statistical precision of 1.1% along and 1.3% transverse to the line of sight, for a combined precision of 0.65% on the isotropic BAO scale at 𝑧 eff =2.33. This excellent precision, combined with recent theoretical studies of the BAO shift due to nonlinear growth, motivated us to include a systematic error term in Ly⁢𝛼 BAO analysis for the first time. We measure the ratios 𝐷 𝐻 ⁡(𝑧 eff )/𝑟 𝑑 = 8.632 ± 0.098 ± 0.026 and 𝐷 𝑀 ⁡(𝑧 eff )/𝑟 𝑑 = 38.99 ± 0.52 ± 0.12, where 𝐷 𝐻 = 𝑐/𝐻⁡(𝑧) is the Hubble distance, 𝐷 𝑀 is the transverse comoving distance, 𝑟 𝑑 is the sound horizon at the drag epoch, and we quote both the statistical and the theoretical systematic uncertainty. The companion paper presents the BAO measurements at lower redshifts from the same dataset and the cosmological interpretation.

baryon acoustic oscillations↗

DESI DR2 Results I: Baryon Acoustic Oscillations from the Lyman Alpha Forest

We present the Baryon Acoustic Oscillation (BAO) measurements with the Lyman-alpha (LyA) forest from the second data release (DR2) of the Dark Energy Spectroscopic Instrument (DESI) survey. Our BAO measurements include both the auto-correlation of the LyA forest absorption observed in the spectra of high-redshift quasars and the cross-correlation of the absorption with the quasar positions. The total sample size is approximately a factor of two larger than the DR1 dataset, with forest measurements in over 820,000 quasar spectra and the positions of over 1.2 million quasars. We describe several significant improvements to our analysis in this paper, and two supporting papers describe improvements to the synthetic datasets that we use for validation and how we identify damped LyA absorbers. Our main result is that we have measured the BAO scale with a statistical precision of 1.1% along and 1.3% transverse to the line of sight, for a combined precision of 0.65% on the isotropic BAO scale at $z_{eff} = 2.33$. This excellent precision, combined with recent theoretical studies of the BAO shift due to nonlinear growth, motivated us to include a systematic error term in LyA BAO analysis for the first time. We measure the ratios $D_H(z_{eff})/r_d = 8.632 \pm 0.098 \pm 0.026$ and $D_M(z_{eff})/r_d = 38.99 \pm 0.52 \pm 0.12$, where $D_H = c/H(z)$ is the Hubble distance, $D_M$ is the transverse comoving distance, $r_d$ is the sound horizon at the drag epoch, and we quote both the statistical and the theoretical systematic uncertainty. The companion paper presents the BAO measurements at lower redshifts from the same dataset and the cosmological interpretation.

79 ASTRONOMY AND ASTROPHYSICS↗

Identifying Nuclear Data Correlated Through Predicting Bias in Integral Experiments via Applying Principal Component Analysis to Random Forest

ABSTRACT Nuclear data (ND) are the input data for neutron‐transport simulations to answer questions related to nuclear technologies. Subsets of ND, here > 20,000 data points, are validated with respect to thousands of criticality experiments that represent various applications on a small scale. The aim of validation with these experiments is to find errors in ND or methods. The key challenge here is that several hundreds of ND are used to simulate one integral value. Hence, one cannot clearly identify what ND are leading to bias in criticality measurements. In fact, a mistake in one nuclear‐data observable can be compensated with an error in another, and the predicted criticality value would still be predicted in agreement with experimental data. Random forest (RF) was previously employed to predict bias in criticality measurements using sensitivities of simulated criticality experiments to ND. The SHapley Additive exPlanations (SHAP) metric was then applied to attribute the importance of each ND experiment and observable to bias prediction. This, however, did not highlight what ND were jointly related to predicting bias. This is important as it could inform us about where compensating errors in ND could hide. We tackle this shortcoming here by first decomposing the ND sensitivities to integral‐experiment simulations into principal components. Then we use principal component projections to predict bias via the RF and SHAP. The SHAP values and principal components are employed to reconstruct detailed SHAP values for each ND observable. We demonstrate that these extended SHAP bias predictions are more robust, less noisy, and more efficient. In addition, we show that this approach accounts for covariance in ND sensitivities and automates the identification of where compensating errors could hide in ND.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A simple method for mitigating error in the fixed-offset of a double-crystal monochromator

In order to maintain a constant monochromatic synchrotron X-ray beam height for all energies, the separation between the crystals of a double-crystal monochromator is typically adjusted, via translation of the second crystal, while X-ray energy is varied, via rotation of the crystal pair. The ability to accurately translate the second crystal requires precise knowledge of the separation between the two crystals and, when present, crystal miscuts. Here, a simple method for calibrating the crystal gap from measured variation in the X-ray beam height that eliminates error in the fixed beam offset is provided.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Science for the Manhattan Project and Comparison to Today’s ENDF Data

Nuclear physics advances in the United States and Britain from 1939 to 1945 are described. The Manhattan Project’s work led to an explosion in our knowledge of nuclear science. A conference in April 1943 at Los Alamos provided a simple formula used to compute critical masses and laid out the research program needed to determine the key nuclear constants. In short order, four university accelerators were disassembled and reassembled at Los Alamos, and methods were established to make measurements on extremely small samples owing to the initial lack of availability of enriched 235U and plutonium. I trace the program that measured fission cross sections, fission-emitted neutron multiplicities and their energy spectra, and transport cross sections, comparing the measurements with our best understanding today as embodied in the Evaluated Nuclear Data File ENDF/B-VIII.0. The large nuclear data uncertainties at the beginning of the project, which often exceeded 25% to 50%, were reduced by 1945 often to less than 5% to 10%. Uranium-235 and plutonium-239 fission cross-section assessments in the fast mega-electron-volt range were reduced following more accurate measurements, and the neutron multiplicity $\overline{v}$ increased. By a lucky coincidence of canceling errors, the initial critical mass estimates were close to the final estimated masses. Some images from historical documents from our Los Alamos archives are shown. Many of the original measurements from these early years have not previously been widely available. Through this work, these data have now been archived in the international experimental nuclear reaction data library (EXFOR) in a collaboration with the International Atomic Energy Agency and Brookhaven National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measuring and unbiasing the BAO shift in the Ly α forest with AbacusSummit

ABSTRACT The Dark Energy Spectroscopic Instrument (DESI) places sub- per cent constraints on measurements of the Baryon Acoustic Oscillation (BAO) scaling parameters from the Ly $\alpha$ forest. However, no systematic error budget stemming from non-linearities in the three-dimensional clustering of the Ly $\alpha$ forest is included in the DESI-Ly $\alpha$ analysis. In this work, we measure the size of the shift of the BAO peak using large Ly $\alpha$ forest mocks produced on the N-body simulation suite AbacusSummit, which adopt the Fluctuating–Gunn–Peterson Approximation (FGPA). Specifically, we measure the Ly $\alpha$ autocorrelation and the Ly $\alpha$-quasar cross-correlation functions. To mitigate the noise, we adopt a linear control variates technique, reducing the error bars by a factor of up to $\sim \sqrt{50}$ on large scales. From the autocorrelation, we detect a small positive shift in radial direction of $\Delta \alpha _{\parallel }= 0.35~{{\ \rm per\ cent}}$ at the 3$\sigma$ level and virtually no shift in the transverse direction, $\alpha _\perp$. From the cross-correlation, we see a similar shift to $\Delta \alpha _\parallel$, albeit with larger error bars, and a small negative shift, $\Delta \alpha _{\perp }=\sim$0.25 per cent, at the 2$\sigma$ level. We also make a connection with the Ly $\alpha$ forest effective field theory (EFT) framework and find that the one-loop EFT power spectrum yields unbiased measurements of the BAO shift parameters in radial and transverse direction for Ly $\alpha$ auto- and the Ly $\alpha$-quasar cross-correlation measurements. When using the one-loop EFT framework, we find that we can recover the BAO parameters without a shift, which has important implications for future Ly $\alpha$ forest analyses based on EFT. This work paves the way for novel full-shape analyses of the currently observing DESI and future surveys such as the PFS, WEAVE-QSO, and 4MOST.

Hadzhiyska, Boryana↗

Validation of Jezebel Reactivity Coefficients and Sensitivity Analysis

Nuclear data validation is often performed today using criticality measurements. The gold standard for criticality measurements is the International Criticality Safety Benchmark Experiment Project (ICSBEP). The validation specifically focuses on the effective multiplication factor ($k_{eff}$). $K_{eff}$ is a relatively easy parameter to infer and has reduced uncertainty due to being at or above critical. However, while $k_{eff}$ is the most documented parameter and its uncertainties and sensitivities have been evaluated in great detail, it cannot be used as a standalone metric to determine inaccuracies in nuclear data (e.g., cross section data, PFNS, nu), which is based on theory, physics, and differential measurements. The Experiments Underpinned by Computational Learning for Improvements in nuclear Data (EUCLID) project aims to identify compensating errors in specific isotope nuclear data by optimally designing experiments that are, or are not sensitive to a suite of measurement parameters beyond $k_{eff}$. By identifying parameters that are sensitive to each other, oppositely sensitive, or have substantial magnitude differences in sensitivity, experiments can be designed to constrain questionable nuclear data. One sensitivity that is of particular interest to this project includes the sensitivity of reactivity coefficients. Reactivity coefficients compare reactivity, which is related to $k_{eff}$ at two different states therefore being sensitive to small changes in the system. The most common type of reactivity coefficient measurements is comparison to void for a small sample within the assembly. It is key that the sample sizes are small enough to not affect the flux of the full system. Reactivity coefficients were evaluated for many early experiments to better understand transport corrected cross sections. In fact, ICSBEP includes reactivity coefficient results as “Supplemental Measurements” in appendices for a handful of older benchmarks. One of those benchmarks is Jezebel, the bare Pu critical assembly. This paper compares new simulations of reactivity coefficients for Jezebel, and explores the sensitivity of reactivity coefficients to small changes in nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multifunctional light beam source for surface slope measuring long trace profilers

To fully exploit the advantages of fourth-generation synchrotron light sources, diffraction-limited-storage-rings (DLSR) and fully coherent free electron lasers (FELs), beamline mirrors and diffraction grating must be of exceptional quality. To achieve the required mirror and grating quality, the metrology instrumentation and methods used to characterize these challenging optics and, even more so, optical assemblies must also offer exceptional functionality and performance. One of the most widely used slope measuring instruments for characterizing x-ray optics is the long trace profiler (LTP). The easily reconfigurable mechanical design of the LTP allows optimization of the profiler arrangement to the specifics of a particular metrology task. Here, we discuss the optical schematic, design, and performance of an original multifunctional light beam source that provides functional flexibility of the LTP optical sensor. With this source, the LTP can be easily reconfigured for measurements of x-ray mirrors or diffraction gratings that have widely different source coherence requirements. Usage of a source with a low degree of coherence for mirror metrology helps to suppress the LTP systematic errors due to spurious interference effects in the LTP optical elements. A high-coherence narrow-band source is used for groove-density-distribution characterization of x-ray diffraction gratings. The systematic error and spatial resolution of the LTP with the different sources is also measured and analyzed.

Yashchuk, Valeriy V.↗

Calibration improvements expand filterscope diagnostic use

The filterscope diagnostic on DIII-D utilizes photomultiplier tubes to measure visible light emission from the plasma. The system has undergone a substantial upgrade since previous attempts to cross-calibrate the filterscope with other spectroscopic diagnostics were unsuccessful. The optics now utilize a dichroic mirror to initially split the light at nearly 99% transmission or reflectance for light below or above 550 nm. This allows the system to measure D α emission without degrading visible light emission from the plasma for wavelengths below 550 nm (to measure D β , D γ , W–I, C-III, etc.). Additional optimization of the optical components and calibration techniques reduce the error in the signal up to 10% in some channels compared to previous methods. Cross-calibration measurements with two other high resolution spectroscopic diagnostics now show excellent agreement for the first time. This expands the capabilities of the filterscope system allowing measurement of divertor detachment, emission profiles, edge-localized mode behavior, and plasma–wall interactions. Additionally, it enables direct comparisons against calculations from boundary plasma simulations. These were not possible before.

47 OTHER INSTRUMENTATION↗

Field-Array Benchmark of Commercial Bifacial PV Technologies with Publicly Available Data

We present results for a 75-kW field array deployed with rows of 5 different commercially available bifacial technologies. Four PERC (multi and mono) and 1 Silicon Heterojunction manufacturers are represented. Reference strings of equivalent monofacial PV modules are also installed in the 10-row field. High accuracy string-level DC monitoring and module-level measurements have been recorded for six months. Analysis indicates performance within expectation, with a cumulative model mean error within +/- 2% for both bifacial and monofacial models and cumulative bifacial energy gain between 6-9%. A custom-module to measure shading loss from the torque-tube was installed. One month data shows up to 6% irradiance non-uniformity. A fixed-tilt test-site with 3 years of bifacial data is also presented, with a bifacial gain of 3%.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Validation of the DESI-DR1 3x2-pt analysis: scale cut and shear ratio tests

Combined survey analyses of galaxy clustering and weak gravitational lensing (3x2-pt studies) will allow new and accurate tests of the standard cosmological model. However, careful validation is necessary to ensure that these cosmological constraints are not biased by uncertainties associated with the modelling of astrophysical or systematic effects. In this study we validate the combined 3x2-pt analysis of the Dark Energy Spectroscopic Instrument Data Release 1 (DESI-DR1) spectroscopic galaxy clustering and overlapping weak lensing datasets from the Kilo-Degree Survey (KiDS), the Dark Energy Survey (DES), and the Hyper-Suprime-Cam Survey (HSC). By propagating the modelling uncertainties associated with the non-linear matter power spectrum, non-linear galaxy bias and baryon feedback, we design scale cuts to ensure that measurements of the matter density and the amplitude of the matter power spectrum are biased by less than 30% of the statistical error. We also test the internal consistency of the data and weak lensing systematics by performing new measurements of the lensing shear ratio. We demonstrate that the DESI-DR1 shear ratios can be successfully fit by the same model used to describe cosmic shear correlations, and analyse the additional information that can be extracted about the source redshift distributions and intrinsic alignment parameters. This study serves as crucial preparation for the upcoming cosmological parameter analysis of these datasets.

Emas, N. [Swinburne U., Ctr. Astrophys. Supercompu↗

A Nonlinear Least Squares Phasor Estimation Algorithm with a Trust Metric

The paper presents a separable nonlinear least squares (NLLS)-based approach for estimation of fundamental-frequency phasors from sampled point-on-wave measurements. An analytical connection is established between the NLLS cost function and the discrete Fourier transform (DFT)-based periodogram of the input signal. This periodogram-based interpretation of the cost function offers an intuitive and easy-to-implement solution for the frequency estimate. Using the residual error of the NLLS-fit, the paper also presents an insightful measure for ascertaining the quality of the phasor estimates and their validity, especially for data windows containing signal transients.

Chatterjee, Kaustav↗

An Open-Access Repository of Synchrophasor Data Quality Examples: Curation and Example Applications

Synchrophasor measurements are critical in providing wide-area situational awareness to power system operators. However, data artifacts may be introduced due to various issues such as loss of communication, loss of GPS signal, internal clock error, and vendor-specific implementation of phasor estimation algorithms. Tools designed to provide actionable insights from synchrophasor data, hence, must be designed to be robust to these data quality issues. In this work, two years of synchrophasor data sourced from multiple electric utilities in the United States were analyzed to identify examples of data quality problems. These examples were then labeled and published in the Grid Event Signature Library, a publicly available repository of power system measurements hosted by the Oak Ridge National Laboratory. This paper describes the data curation process, and illustrates two application use cases where the dataset can be valuable to the research community. In the first use case, a random forest classifier is trained to distinguish power system disturbance signatures from data anomalies introduced in synchrophasor measurements due to clock errors. The second use case studies the impact of data quality issues on an example synchrophasor application (specifically, event start time determination). The choice of data quality problems investigated is informed by the examples in the repository curated in this work.

24 POWER TRANSMISSION AND DISTRIBUTION↗