Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “matrix approximation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Inducer Hydrodynamic Forces in a Cavitating Environment

Marshall Space Flight Center has developed and demonstrated a measurement device for sensing and resolving the hydrodynamic loads on fluid machinery. The device - a derivative of the six-component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This rotating balance was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining the amplitude and frequency content associated with operating in various cavitation modes. The rotating balance was calibrated statically using a dead-weight load system in order to generate the 6 x 12 calibration matrix later used to convert measured voltages to engineering units. Structural modeling suggested that the rotating assembly first bending mode would be significantly reduced with the balance s inclusion. This reduction in structural stiffness was later confirmed experimentally with a hammer-impact test. This effect, coupled with the relatively large damping associated with the rotating balance waterproofing material, limited the device s bandwidth to approximately 50 Hertz Other pre-test validations included sensing the test article rotating assembly built-in imbalance for two configurations and directly measuring the assembly mass and buoyancy while submerged under water. Both tests matched predictions and confirmed the device s sensitivity while stationary and rotating. The rotating balance was then demonstrated in a water test of a full-scale Space Shuttle Main Engine high-pressure liquid oxygen pump inducer. Experimental data was collected a scaled operating conditions at three flow coefficients across a range of cavitation numbers for the single inducer geometry and radial clearance. Two distinct cavitation modes were observed symmetric tip vortex cavitation and alternate-blade cavitation. Although previous experimental tests on the same inducer demonstrated two additional cavitation modes at lower inlet pressures, these conditions proved unreachable with the rotating balance installed due to the intense dynamic environment. The sensed radial load was less influenced by flow coefficient than by cavitation number or cavitation mode although the flow coefficient range was relatively narrow. Transition from symmetric tip vortex to alternate-blade cavitation corresponded to changes in both radial load magnitude and radial load orientation relative to the inducer. Sensed moments indicated that the effective load center moved downstream during this change in cavitation mode. An occurrence of "higher+rdex cavitation" was also detected in both the stationary pressures and the rotating balance data although the frequency of the phenomena was well above the reliable bandwidth of the rotating balance. In summary the experimental tests proved both the concept and device s capability despite the limitations and confirmed that hydrodynamically-induced forces and moments develop in response to the unbalanced pressure field, which is, in turn, a product of the cavitation environment.

Skelley, Stephen E.↗

Analysis of twisting stiffness for a multifiber composite layer

The twisting stiffness of a rectangular cross section consisting of a single row of solid circular cross-section fibers embedded in a matrix is analyzed. The problem is formulated as a Dirichlet torsion problem of a multielement region and solved by the boundary-point least-squares method. Numerical results for a single-fiber square cross section compare favorably with previous relaxation-method results. New numerical results for three and five-fiber composites suggest that the torsional rigidity of a multifiber composite can be approximated from the torsional rigidities of single and three-fiber models.

Bert, C. W.↗

Completion of the Viking Labeled Release experiment on Mars

The final Labeled Release (LR) cycle on each Viking lander tested a surface sample that had been stored for several months at approximately 10 C prior to the onset of the active sequence. At each lander site, activity was strongly diminished. This thermal sensitivity of the active agent on the surface of Mars is consistent with a biological explanation of the LR experiment. At the end of one of these cycles, the incubation mixture was heated to 50 C to release any radioactive gas trapped in the sample matrix. The results suggest that more than one carbon substrate is involved in the LR reaction on Mars. The thermal data from the stored samples, coupled with data from previous cycles, have formed the basis for evaluation of the thermal decomposition of the Mars active agent. The slope of the resulting Arrhenius plot has been used to test the fit of other flight data and to calculate the activation energy for thermal decomposition of the Mars agent. The results and their interpretation still leave unresolved the question of whether the Mars LR data were generated by biological or chemical activity.

Levin, G. V.↗

Domain decomposition methods in aerodynamics

Compressible Euler equations are solved for two-dimensional problems by a preconditioned conjugate gradient-like technique. An approximate Riemann solver is used to compute the numerical fluxes to second order accuracy in space. Two ways to achieve parallelism are tested, one which makes use of parallelism inherent in triangular solves and the other which employs domain decomposition techniques. The vectorization/parallelism in triangular solves is realized by the use of a recording technique called wavefront ordering. This process involves the interpretation of the triangular matrix as a directed graph and the analysis of the data dependencies. It is noted that the factorization can also be done in parallel with the wave front ordering. The performances of two ways of partitioning the domain, strips and slabs, are compared. Results on Cray YMP are reported for an inviscid transonic test case. The performances of linear algebra kernels are also reported.

Venkatakrishnan, V.↗

Mechanical properties of monolithic and particulate composites of L12 forms of Al3Ti

Preliminary studies of simple compressive properties of particulate composites with L1(2)-modified Al3Ti's as the matrices were performed as functions of matrix composition, amount of TiB2, processing technique, temperature, and strain rate. At and below about 900 K the introduction of TiB2 particles overwhelms minor chemical effects, and extremely high-yield strengths (about 2000 MPa at the 20 vol pct TiB2 level) were obtained. As L1(2)-modified Al3Ti has about half the density of the Ni-base superalloys, such values translate to strength/density ratios approximately four times those for superalloys. This advantage is not maintained by the Al3Ti-based composites above about 1000 K, particularly under slow strain rate plastic flow conditions, and it is proposed that this behavior could be due to the dissolution of intermetallic second phases as well as grain boundary creep mechanisms.

Whittenberger, J. D.↗

Carbon Nanotube/Polymer Nanocomposites Flexible Stress and Strain Sensors

Conformable stress and strain sensors are required for monitoring the integrity of airframe structures as well as for sensing the mechanical stimuli in prosthetic arms. For this purpose, we have developed a series of piezoresistive single-wall carbon nanotube (SWCNT)/polymer nanocomposites. The electromechanical coupling of pressure with resistance changes in these nanocomposites is exceptionally greater than that of metallic piezoresistive materials. In fact, the piezoresistive stress coefficient (pi) of a SWCNT/polymer nanocomposite is approximately two orders of magnitude higher than that of a typical metallic piezoresistive. The piezoresistive stress coefficient is a function of the nanotube concentration wherein the maximum value occurs at a concentration just above the percolation threshold concentration (phi approx. 0.05 %). This response appears to originate from a change in intrinsic resistivity under compression/tension. A systematic study of the effect of the modulus of the polymer matrix on piezoresistivity allowed us to make flexible and conformable sensors for biomedical applications. The prototype haptic sensors using these nanocomposites are demonstrated. The piezocapacitive properties of SWCNT/polymer are also characterized by monitoring the capacitance change under pressure.

Kang, Jin Ho↗

Reduction of Raman Spectroscopy Data for H2-CO2-Air Tubular Flame Measurements

An approach of reducing spontaneous Raman spectroscopy data, based on the matrix inversion method which logically removes undesired sources of the Raman scattering signals including cross-talk due to the signals from other species, is discussed. The approach contains extensive calibration of temperature-dependent system response. The Raman spectra of several cold and hot calibration flames and their resulting calibration matrix are elaborated. The structure of H2-CO2-air tubular flames, in terms of major species (CO2, O2, N2, H2O, and H2) concentrations and temperature, was successfully measured with the optical technique. The Raman spectra data used in this study are taken from a uniquely designed experimental apparatus – a tubular burner and Raman spectroscopy system at Vanderbilt University. The characteristic uncertainties for chemical species are approximately ±2% by mole fraction for hot products and ±0.5% for room temperature reactants. The approach described here for hydrogen/air tubular flames may be adapted to hydrocarbon/air tubular flames when other necessary major species, for example, CH4 and CO for methane/air tubular flame, are considered in the whole process.

Raman Spectroscopy↗

Theoretical research program to study transition metal trimers and embedded clusters

Small transition metal clusters were studied at a high level of approximation, including all the valence electrons in the calculation and extensive electron correlation, in order to understand the electronic structure of these small metal clusters. By comparison of dimers, trimers, and possibly higher clusters, the information obtained was used to provide insights into the electronic structure of bulk transition metals. Small metal clusters are currently of considerable experimental interest and some information is becomming available both from matrix electron spin resonance studies and from gas phase spectroscopy. Collaboration between theorists and experimentalists is thus expected to be especially profitable at this time since there is some experimental information which can serve to guide the theoretical work.

Walch, S. P.↗

Errors in reduction methods

A mathematical basis is given for comparing the relative merits of various techniques used to reduce the order of large linear and nonlinear dynamics problems during their numerical integration. In such techniques as Guyan-Irons, path derivatives, selected eigenvectors, Ritz vectors, etc., the nth order initial value problem of /y(dot) = f(y) for t greater than 0, y(0) given/ is typically reduced to the mth order (m is much less than n) problem of /z(dot) = g(z) for t greater than 0, z(0) given/ by the transformation y = Pz where P changes from technique to technique. This paper gives an explicit approximate expression for the reduction error e-i in terms of P and the Jacobian of f. It is shown that: (a) reduction techniques are more accurate when the time rate of change of the response y is relatively small; (b) the change in response between two successive stations contributes to the errors at future stations after the change in response is transformed by a filtering matrix H, defined in terms of P; (c) the error committed at a station propagates to future stations by a mixing and scaling matrix G, defined in terms of P, Jacobian and of f, and time increment h. The paper discusses the conditions under which the reduction errors may be minimized and gives guidelines for selecting the reduction basis vector, i.e., the columns of P.

Utku, S.↗

Processable, high temperature polymers from 1,4,5,8-tetrahydro-1,4;5,8-diepoxyanthracene and bis-dienes

1,4,5,8-tetrahydro-1,4;5,8-diepoxyanthracene reacts with various anthracene end-capped polyimide oligomers to form Diels-Alder cycloaddition copolymers. The polymers are soluble in common organic solvents, and have molecular weights of approximately 21,000 to 32,000. These resins exhibit lower weight loss in air than in nitrogen. This is suggested to be due to dehydration (loss of water ranges from 2 to 5 percent) at temperatures of 390 to 400 C to give thermooxidatively stable pentiptycene units along the polymer backbone. Because of their high softening points and good thermooxidative stability, the polymers have potential as processable, matrix resins for high temperature composite applications.

Meador, Mary Ann B.↗

Development of a steady potential solver for use with linearized, unsteady aerodynamic analyses

A full potential steady flow solver (SFLOW) developed explicitly for use with an inviscid unsteady aerodynamic analysis (LINFLO) is described. The steady solver uses the nonconservative form of the nonlinear potential flow equations together with an implicit, least squares, finite difference approximation to solve for the steady flow field. The difference equations were developed on a composite mesh which consists of a C grid embedded in a rectilinear (H grid) cascade mesh. The composite mesh is capable of resolving blade to blade and far field phenomena on the H grid, while accurately resolving local phenomena on the C grid. The resulting system of algebraic equations is arranged in matrix form using a sparse matrix package and solved by Newton's method. Steady and unsteady results are presented for two cascade configurations: a high speed compressor and a turbine with high exit Mach number.

Hoyniak, Daniel↗

The Influence of Correlated Crustal Signals in Modelling the Main Geomagnetic Field

Algorithms used in geomagnetic main-field modelling have for the most part treated the noise in the field measurements as if it were white. A major component of the noise consists of the field due to magnetization in the crust and it has been realized for some time that such signals are highly correlated at satellite altitude. Hence approximation by white noise, while of undoubted utility, is of unknown validity. In this paper we study two plausible statistical models for the crustal magnetization, in which the magnetization is a realization of a stationary, isotropic, random process. At a typical satellite altitude the associated fields exhibit significant correlation over ranges as great as 15 deg. or more, which introduces off-diagonal elements into the covariance matrix, elements that have usually been neglected in modelling procedures. Dealing with a full covariance matrix for a large data set would present a formidable computational challenge, but fortunately most of the entries in the covariance matrix are so small that they can be replaced by zeros. The resultant matrix comprises only about 3 per cent non-zero entries and thus we can take advantage of efficient sparse matrix techniques to solve the numerical system. We construct several main-field models based on vertical-component data from a selected 5 deg. by 5 deg. data set derived from the Magsat mission. Models with and without off-diagonal terms are compared.

Rygaard-Hjalsted, C.↗

Development of microchannel plates in advanced wind-tunnel instrumentation

Microchannel plate (MCP) electron multiplier dynamic range has been increased 3 to 4 orders of magnitude at ambient temperatures, through enhanced input count rate capability and reduced background or 'dark' noise. The previous upper limit of roughly 10(exp 7) - 10(exp 8) cm(exp -2)s(exp -1) at ambient has been extended to levels approach 10(exp 10) cm(exp -2)s(exp -1) under continuous dc operation. The lower limit, previously set by an irreducible background component (approximately 0.6 cm(exp -2)s(exp -1)), has been lowered to the cosmic ray limit of .01 cm(exp -2)s(exp -1). The high end improvement was achieved by conductively cooling a very low resistance MCP by bonding it to a heat sink, while maintaining pulse-counting operation with multianode readouts. The low-end improvement was achieved by removing all radioisotopes from the MCP matrix glass. The detectors will benefit optical and mass spectrometry, flow visualization, plasma diagnostics, magnetometry, and other high signal flux applications. Very low MCP background noise will benefit X-ray and UV astronomy, medical imaging, trace isotope mass spectrometry, and other applications where the signal flux is often extremely low.

Feller, W. Bruce↗

Changes in gravity inhibit lymphocyte locomotion through type I collagen

Immunity relies on the circulation of lymphocytes through many different tissues including blood vessels, lymphatic channels, and lymphoid organs. The ability of lymphocytes to traverse the interstitium in both nonlymphoid and lymphoid tissues can be determined in vitro by assaying their capacity to locomote through Type I collagen. In an attempt to characterize potential causes of microgravity-induced immunosuppression, we investigated the effects of simulated microgravity on human lymphocyte function in vitro using a specialized rotating-wall vessel culture system developed at the Johnson Space Center. This very low shear culture system randomizes gravitational vectors and provides an in vitro approximation of microgravity. In the randomized gravity of the rotating-wall vessel culture system, peripheral blood lymphocytes did not locomote through Type I collagen, whereas static cultures supported normal movement. Although cells remained viable during the entire culture period, peripheral blood lymphocytes transferred to unit gravity (static culture) after 6 h in the rotating-wall vessel culture system were slow to recover and locomote into collagen matrix. After 72 h in the rotating-wall vessel culture system and an additional 72 h in static culture, peripheral blood lymphocytes did not recover their ability to locomote. Loss of locomotory activity in rotating-wall vessel cultures appears to be related to changes in the activation state of the lymphocytes and the expression of adhesion molecules. Culture in the rotating-wall vessel system blunted the ability of peripheral blood lymphocytes to respond to polyclonal activation with phytohemagglutinin. Locomotory response remained intact when peripheral blood lymphocytes were activated by anti-CD3 antibody and interleukin-2 prior to introduction into the rotating-wall vessel culture system. Thus, in addition to the systemic stress factors that may affect immunity, isolated lymphocytes respond to gravitational changes by ceasing locomotion through model interstitium. These in vitro investigations suggest that microgravity induces non-stress-related changes in cell function that may be critical to immunity. Preliminary analysis of locomotion in true microgravity revealed a substantial inhibition of cellular movement in Type I collagen. Thus, the rotating-wall vessel culture system provides a model for analyzing the microgravity-induced inhibition of lymphocyte locomotion and the investigation of the mechanisms related to lymphocyte movement.

Weightlessness↗

A NASTRAN implementation of the doubly asymptotic approximation for underwater shock response

A detailed description is given of how the decoupling approximation known as the doubly asymptotic approximation is implemented with NASTRAN to solve shock problems for submerged structures. The general approach involves locating the nonsymmetric terms (which couple structural and fluid variables) on the right hand side of the equations. This approach results in coefficient matrices of acceptable bandwidth but degrades numerical stability, requiring a smaller time step size than would otherwise be used. It is also shown how the structure's added (virtual) mass matrix, is calculated with NASTRAN.

Everstine, G. C.↗

Formation chronology for C2 meteorites

The times at which phyllosilicate matrix and euhedral olivines became associated have been determined for five C2 meteorites. The ages, calculated from fission track densities on crystal surfaces, are based on an initial Pu-244/U-238 ratio in the matrix material of 0.0154 at 4.6 b.y., and range from 4.22 b.y. for Nogoya to 4.42 b.y. for Murray. Unless the initial Pu-244/U-238 ratio was less than 0.004, the meteorites cannot have existed in their present form for 4.6 billion years. The measured ages place limits on the time when pre-compaction effects such as micrometeorite craters and solar flare tracks were produced, and they may approximately date the formation of the olivine crystals themselves.

Macdougall, J. D.↗

Fatigue response of notched laminates subjected to tension-compression cyclic loads

The fatigue response of a ((0/45/90/-45)(sub s))(sub 4) T300-5208 graphite-epoxy laminate with a drilled center-hole subjected to various components of tensile and compressive cyclic loads was investigated. Damage evaluation techniques such as stiffness monitoring, penetrant-enhanced X-ray radiography, C-scan, laminate deply and residual strength measurement were used to establish the mechanisms of damage development as well as the effect of such damage on the laminate strength, stiffness and life. Damage modes consisted of transverse matrix cracks, initiating at the hole, in all plies, followed by delamination between plies of different orientation. A characteristic stiffness repsonse during cyclic loading at two load levels was identified and utilized a more reliable indicator of material and residual properties than accumulated cycles. For the load ratios of tension-compression loading, residual tensile strength increased significantly above the virgin strength early in the fatigue life and remained approximately constant to near the end of life. A technique developed for predicting delamination initiation sites along the hole boundary correlated well with experimental evidence.

Bakis, C. E.↗

Design Analysis and Thermo-Mechanical Fatigue of a Polyimide Composite for Combustion Chamber Support

Polyimide composites are being evaluated for use in lightweight support structures designed to preserve the ideal flow geometry within thin shell combustion chambers of future space launch propulsion systems. Principles of lightweight design and innovative manufacturing techniques have yielded a sandwich structure with an outer face sheet of carbon fiber polyimide matrix composite. While the continuous carbon fiber enables laminated skin of high specific stiffness; the polyimide matrix materials ensure that the rigidity and durability is maintained at operation temperatures of 316 C. Significant weight savings over all metal support structures are expected. The protypical structure is the result of ongoing collaboration, between Boeing and NASA-GRC seeking to introduce polyimide composites to the harsh environmental and loads familiar to space launch propulsion systems. Design trade analyses were carried out using relevant closed form solutions, approximations for sandwich beams/panels and finite element analysis. Analyses confirm the significant thermal stresses exist when combining materials whose coefficients of thermal expansion (CTEs) differ by a factor of about 10 for materials such as a polymer composite and metallic structures. The ramifications on design and manufacturing alternatives are reviewed and discussed. Due to stringent durability and safety requirements, serious consideration is being given to the synergistic effects of temperature and mechanical loads. The candidate structure operates at 316 C, about 80% of the glass transition temperature T(sub g). Earlier thermomechanical fatigue (TMF) investigations of chopped fiber polyimide composites made this near to T(sub g), showed that cyclic temperature and stress promoted excessive creep damage and strain accumulation. Here it is important to verify that such response is limited in continuous fiber laminates.

Thesken, J. C.↗