Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “material analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Boron isotopic analysis in bulk silicate materials using the Neoma MS/MS MC-ICP-MS

Boron (B) isotopes are a valuable tracer with applications ranging from geological, environmental, and nuclear studies because B isotopic fractionation is highly sensitive to chemical processes yielding distinct isotopic trends in natural and anthropogenic systems. Despite this wide applicability, there remain relatively few measurements on well-described reference materials and in some cases, poor agreement between various methods. We report a method for boron isotope ratio measurement in solution on the Neoma MS/MS MC-ICP-MS specifically targeting bulk silicates. We evaluate the performance of the method and instrument as it relates to the measurement of the absolute boron isotope ratio ( 10 B/ 11 B). The results indicate that the method produces data in agreement with literature values and that the sample–standard bracketing technique is appropriate for the Neoma MS/MS MC-ICP-MS which has been in use for decades on previous generation instruments. Careful tuning of the MS/MS lenses is required to obtain precision comparable to non MS/MS equipped MC-ICP-MS. With careful tuning, internal and external precisions of ∼0.3‰ were achieved. However, when the MS/MS is not properly tuned external precisions exceed 3‰. Nevertheless, our results for IAEA B-6, BCR-2, BHVO-2 and W-2a reference materials overlap the 1σ range of previously reported 10 B/ 11 B. Data are reported for total boron quantities down to a few tens of nanograms. Our procedure yielded blanks as low as 3 ng but up to 29 ng, making blank corrections important for small samples sizes in the few 10s of nanogram range. We report B isotope ratios for AGV-2G, SL-1G, GSC-2G, GSD-2G, GSE-2G, RLS-132, RLS-140, NKT-1G, and T1-G glass reference materials that have not been previously reported in the literature.

Scott, Sean R. [Pacific Northwest National Laborat↗

Micro differential thermal analysis detection of adsorbed explosive molecules using microfabricated bridges

Although micromechanical sensors enable chemical vapor sensing with unprecedented sensitivity using variations in mass and stress, obtaining chemical selectivity using the micromechanical response still remains as a crucial challenge. Chemoselectivity in vapor detection using immobilized selective layers that rely on weak chemical interactions provides only partial selectivity. Here we show that the very low thermal mass of micromechanical sensors can be used to produce unique responses that can be used for achieving chemical selectivity without losing sensitivity or reversibility. We demonstrate that this method is capable of differentiating explosive vapors from nonexplosives and is additionally capable of differentiating individual explosive vapors such as trinitrotoluene, pentaerythritol tetranitrate, and cyclotrimethylenetrinitromine. This method, based on a microfabricated bridge with a programmable heating rate, produces unique and reproducible thermal response patterns within 50 ms that are characteristic to classes of adsorbed explosive molecules. We demonstrate that this micro-differential thermal analysis technique can selectively detect explosives, providing a method for fast direct detection with a limit of detection of 600 x 10{sup -12} g.

Senesac, Larry R↗

Reconstruction of the interatomic forces from dynamic scanning transmission electron microscopy data

We explore the possibility for reconstruction of the generative physical models describing interactions between atomic units in solids from observational electron microscopy data. In this work, scanning transmission electron microscopy (STEM) is used to observe the dynamic motion of Si atoms at the edge of monolayer graphene under continuous electron beam illumination. The resulting time-lapsed STEM images represent the snapshots of observed chemical states of the system. We use two approaches: potential of mean force calculation using a radial distribution function and a direct fitting of the graphene–Si interatomic pairwise potentials with force matching, to reconstruct the force fields in the materials. These studies lay the foundation for quantitative analysis of materials energetics from STEM data through the sampling of the metastable states in the chemical space of the system.

42 ENGINEERING↗

A new woven composite constitutive model validated by shock wave experiments

In this paper, we present results of plate impact simulations of shock compressed woven glass fiber-reinforced plastic (GRP) performed using the Arbitrary Lagrangian–Eulerian three-dimensional finite element code. A hyperelastic large-strain-based empirical Continuum Damage Mechanics (CDM) formulation is employed to describe damage initiation and growth in the shock-compressed GRP. The model parameters calibration scheme utilizes the Velocity Interferometer System for Any Reflector normal particle velocity measurements at the free surface of the GRP target plates. The impact velocity in the experiments ranged from 8.5 to 418 m/s. The finite element model considered planar 0°/90° bidirectional plies with an individual ply thickness of 0.68 mm, stacked to reach a total laminate thickness of 6.8 mm. The anisotropic elastic strains were estimated from the experimentally determined tetragonal symmetry stiffness matrix for the GRP. The strain-based damage model captures several salient features observed in the measured free surface particle wave profiles, including the shock rise time, onset of Elastic—Elastic Cracking, and the shape of the nonlinear portion of the experimental particle velocity profiles. Furthermore, the CDM model predicts the dominant damage mode to be matrix microcracking due to shear and the associated bulk expansion (bulking) under the global compressive loading in the plate impact configuration.

42 ENGINEERING↗

Analysis of nickel sulfoselenide materials by XPS

Metal chalcogenides are of interest as electrocatalysts, battery materials, and more. XPS is a valuable tool for studying changes to these materials before and after catalysis, making reference spectra for the pristine materials valuable. Here, we present XPS spectra for a family of nickel sulfoselenide (NiSSe) materials based on the Ni 3 X 2 crystal structure, Ni 3 S 2-x Se x . XPS surveys and high-resolution spectra of Ni 2p, S 2p, S 2s, Se 3d, Se 3p, and Se 3s were recorded using Al K α radiation.

36 MATERIALS SCIENCE↗

X-ray phase contrast imaging of the breast: Analysis of tissue simulating materials

Purpose: Phase contrast imaging, particularly of the breast, is being actively investigated. The purpose of this work is to investigate the x-ray phase contrast properties of breast tissues and commonly used breast tissue substitutes or phantom materials with an aim of determining the phantom materials best representative of breast tissues. Methods: Elemental compositions of breast tissues including adipose, fibroglandular, and skin were used to determine the refractive index, n= 1 -{delta}+i {beta}. The real part of the refractive index, specifically the refractive index decrement ({delta}), over the energy range of 5-50 keV were determined using XOP software (version 2.3, European Synchrotron Radiation Facility, France). Calcium oxalate and calcium hydroxyapatite were considered to represent the material compositions of microcalcifications in vivo. Nineteen tissue substitutes were considered as possible candidates to represent adipose tissue, fibroglandular tissue and skin, and four phantom materials were considered as possible candidates to represent microcalcifications. For each material, either the molecular formula, if available, or the elemental composition based on weight fraction, was used to determine {delta}. At each x-ray photon energy, the absolute percent difference in {delta} between the breast tissue and the substitute material was determined, from which three candidates were selected. From these candidate tissue substitutes, the material that minimized the absolute percent difference in linear attenuation coefficient {mu}, and hence {beta}, was considered to be best representative of that breast tissue. Results: Over the energy range of 5-50 keV, while the {delta} of CB3 and fibroglandular tissue-equivalent material were within 1% of that of fibroglandular tissue, the {mu} of fibroglandular tissue-equivalent material better approximated the fibroglandular tissue. While the {delta} of BR10 and adipose tissue-equivalent material were within 1% of that of adipose tissue, the tissue-equivalent material better approximated the adipose tissue in terms of {mu}. Polymethyl methacrylate, a commonly used tissue substitute, exhibited {delta} greater than fibroglandular tissue by {approx}12%. The A-150 plastic closely approximated the skin. Several materials exhibited {delta} between that of adipose and fibroglandular tissue. However, there was an energy-dependent mismatch in terms of equivalent fibroglandular weight fraction between {delta} and {mu} for these materials. For microcalcifications, aluminum and calcium carbonate were observed to straddle the {delta} and {mu} of calcium oxalate and calcium hydroxyapatite. Aluminum oxide, commonly used to represent microcalcifications in the American College of Radiology recommended phantoms for accreditation exhibited {delta} greater than calcium hydroxyapatite by {approx}23%. Conclusions: A breast phantom comprising A-150 plastic to represent the skin, commercially available adipose and fibroglandular tissue-equivalent formulations to represent adipose and fibroglandular tissue, respectively, was found to be best suited for x-ray phase-sensitive imaging of the breast. Calcium carbonate or aluminum can be used to represent microcalcifications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A setup for active neutron analysis of the fissile material content in fuel assemblies of nuclear reactors

An active neutron method for measuring the residual mass of {sup 235}U in spent fuel assemblies (FAs) of the IRT MEPhI research reactor is presented. The special measuring stand design and uniform irradiation of the fuel with neutrons along the entire length of the active part of the FA provide high accuracy of determination of the residual {sup 235}U content. AmLi neutron sources yield a higher effect/background ratio than other types of sources and do not induce the fission of {sup 238}U. The proposed method of transfer of the isotope source in accordance with a given algorithm may be used in experiments where the studied object needs to be irradiated with a uniform fluence.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Technical Readiness and Gaps Analysis of Commercial Optical Materials and Measurement Systems for Advanced Small Modular Reactors

This report intends to support Department of Energy’s Office of Nuclear Energy (DOE-NE) Nuclear Energy Research and Development Roadmap and industry stakeholders by evaluating optical-based instrumentation and control (I&C) concepts for advanced small modular reactor (AdvSMR) applications. These advanced designs will require innovative thinking in terms of engineering approaches, materials integration, and I&C concepts to realize their eventual viability and deployability. The primary goals of this report include: 1. Establish preliminary I&C needs, performance requirements, and possible gaps for AdvSMR designs based on best available published design data. 2. Document commercial off-the-shelf (COTS) optical sensors, components, and materials in terms of their technical readiness to support essential AdvSMR in-vessel I&C systems. 3. Identify technology gaps by comparing the in-vessel monitoring requirements and environmental constraints to COTS optical sensor and materials performance specifications. 4. Outline a future research, development, and demonstration (RD&D) program plan that addresses these gaps and develops optical-based I&C systems that enhance the viability of future AdvSMR designs. The development of clean, affordable, safe, and proliferation-resistant nuclear power is a key goal that is documented in the Nuclear Energy Research and Development Roadmap. This roadmap outlines RD&D activities intended to overcome technical, economic, and other barriers, which currently limit advances in nuclear energy. These activities will ensure that nuclear energy remains a viable component to this nation’s energy security.

advanced small modular reactors↗

Final Report: Rational Design of Wide Band Gap Buffer Layers for High-Efficiency Thin-Film Photovoltaics

The main objective of this project is to enable rational design of wide band gap buffer layer materials for CIGS thin-film PV by building understanding of the correlation of atomic-scale defects in the buffer layer and at the buffer/absorber interface with device electrical properties. Optimized wide band gap buffers are needed to reduce efficiency loss from parasitic absorption in the buffer. The approach uses first-principles materials simulations coupled with nanoscale analytical electron microscopy as well as device electrical characterization. Materials and devices are produced by an industrial partner in a manufacturing line to maximize relevance, with the goal of enabling R&D of new buffer layer compositions or deposition processes to push device efficiencies above 21%. Cadmium sulfide (CdS) is the reference material for analysis, as the prototypical high-performing buffer material.

14 SOLAR ENERGY↗

Simulation Analysis of Geometry and Material Effects for Dropkinson Bar

The reported research is motivated by the need to address a key issue affecting the Dropkinson bar apparatus. This unresolved issue is the interference of the stress wave reflected from the bar-beam boundary with the measurement of the stress-strain response of a material tested in the apparatus. The purpose of the wave beam that is currently connected to the bar is to dissipate the stress wave, but the portion of the wave reflected from the bar-beam boundary is still significant. First, we focused on understanding which parameters affect the reflected wave's arrival time at a strain gauge. Specifically, we used finite-element numerical simulations with the Sierra/SM module to study the effects of various bar-beam connection fixities, alternative wave beam materials, and alternative geometries of the Dropkinson bar system based on a monolithic design. The conclusion of this study is that a partial reflection always occurs at the bar-beam boundary (or, for a monolithic design, at a point where the bar geometry changes). Therefore, given a fixed total length of the bar, it is impossible to increase the reflected wave's arrival time by any significant amount. After reaching this conclusion, we focused instead on trying to minimize the energy of the reflected stress wave circulating up and down through the bar over a relatively long period of time (10 ms). Once again, we used numerical simulations with the Sierra/SM module to investigate the effects of various bar-beam connection fixities, alternative wave beam materials, and parameters of an asymmetric monolithic design of the bar-and-beam system. This study demonstrated that various parameters can significantly affect the energy of the wave reflections, with the difference between best and worst configurations being about one order of magnitude in terms of energy. Based on the obtained results, we conclude with concrete takeaways for Dropkinson bar users and propose potential directions for future research and optimization.

36 MATERIALS SCIENCE↗

Assessment of Fluoropolymer Production and Use With Analysis of Alternative Replacement Materials

This report focuses on fluoropolymers, which are a subgroup of the much larger class of fluorinated chemicals known as per- and polyfluoroalkyl substances (PFAS). Clearly distinguishing fluoropolymers is important to understanding their distinctive chemical properties, associated risks and benefits, and roles in commerce. In this report, the factors that are considered in a lifecycle assessment (LCA) of fluoropolymers will be discussed. These include the manufacturing of fluoropolymers, their use in industry, and available replacement technologies. Emphasis is placed on fluoropolymer plastics because of their extensive use in the commerce sectors considered here, specifically aerospace, automotive, battery, building construction, chemical processing, electronics, infrastructure, semiconductor, solar panel, and wind energy industries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Novel Concentrating Solar Weathering Apparatus for Experimental Validation of Multi-Modal Degradation Models

High-performance coatings for Concentrating Solar Power (CSP) receivers are subjected to remarkable environmental stressors during normal operations. Applied to the receiver tubes, these coatings serve to maximize the solar absorptivity of the receiver, transferring as much heat as possible from the solar collectors into the heat-transfer fluid (HTF). The lifecycle of these coatings is not well-defined, and the harsh operational conditions make them difficult to test. NREL has designed, built, and tested an apparatus to expose these samples to design levels of environmental stress and well beyond, into accelerated and destructive conditions. The chamber is actively cooled, monitored, and has the capability to supply humidification for cycling tests, allowing us to test multi-modal degradation and failure conditions at high temperature, high flux, and high humidity conditions. These conditions can catalyze high-temperature oxidation, mechanical degradation, and other modes of absorptivity loss seen in selective solar receiver coatings. The experimental data can feed lifecycle models for expensive and necessarily resilient materials, offering insights to aid maintenance schedules, technoeconomic analysis, and material industry performance benchmarks. This presentation will demonstrate the apparatus design and performance, as well as initial results for aging on a selective receiver coating.

14 SOLAR ENERGY↗