Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “local grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Frequency Analysis of Solar PV Power to Enable Optimal Building Load Control

In this paper, we present a flexibility estimation mechanism for buildings’ thermostatically controlled loads (TCLs) to enable the distribution level consumption of the majority of solar photovoltaic (PV) generation by local building TCLs. The local consumption of PV generation provides several advantages to the grid operation as well as the consumers, such as reducing the stress on the distribution network, minimizing voltage fluctuations and two-way power flows in the distribution network, and reducing the required battery storage capacity for PV integration. This would result in increasing the solar PV generation penetration levels. The aims of this study are twofold. First, spectral (frequency) analyses of solar PV power generation together with the power consumption of multiple building TCLs (such as heating, ventilation, and air conditioning (HVAC) systems, water heaters, and refrigerators) are performed. These analyses define the bandwidth over which these TCLs can operate and also describe the PV generation frequency bandwidth. Such spectral analyses, in frequency domain, can help identify the flexible components of PV generation that can be consumed by the various TCLs through optimal building load utilization. Second, a quadratic optimization problem based on model predictive control is formulated to allow consuming most of the low and medium frequency content of the PV power locally by building TCLs, while maintaining occupants’ comfort and TCLs’ physical constraints. The solution to the proposed optimization problem is achieved using optimal control strategies. Numerical results show that most of the low and medium frequency content of the PV generation can be consumed locally by building TCLs. The remaining high-frequency content of the PV generation can then be stored/offset using energy storage systems.

14 SOLAR ENERGY↗

Automated and efficient local adaptive regression for principal component-based reduced-order modeling of turbulent reacting flows

Principal Component Analysis can be used to reduce the cost of Computational Fluid Dynamics simulations of turbulent reacting flows by reducing the dimensionality of the transported variables through projection of the thermochemical state onto a lower-dimensional manifold. However, because of the nonlinearity of the principal component source terms, nonlinear regression techniques must be utilized for the source terms in terms of the principal components. Unfortunately, widely available and utilized nonlinear regression techniques can have prohibitive computational requirements and/or accuracy that is highly dependent on user experience in ad hoc tuning of model architecture and hyperparameters. Here, in this work, a new nonlinear regression approach is proposed that is both computationally efficient and automated so does not require any user input. The approach is evaluated through a priori prediction of principal component source terms using data from a Direct Numerical Simulation of a turbulent nonpremixed n-heptane/air jet flame. In particular, the proposed framework consists of local regressions whose complexity is adapted according to the local nonlinearity of the data: local linear regression when accurate enough and local Artificial Neural Networks when nonlinear regression is required. The number of local clusters for local regression is determined automatically using the Davies-Bouldin index. In addition, Bayesian optimization is utilized for model training (i.e., to select the best architectures and hyperparameters of the nonlinear regressions in an unsupervised fashion), eliminating ad hoc hand-tuning and/or expensive grid searches. Overall, compared to a single, global neural network, the new local adaptive regression approach is shown to have comparable accuracy but 69% less training time due to the utilization of local linear regression and faster training of local neural networks.

42 ENGINEERING↗

Learning Provably Stable Local Volt/Var Controllers for Efficient Network Operation

Here this paper develops a data-driven framework to synthesize local Volt/Var control strategies for distributed energy resources (DERs) in power distribution grids (DGs). Aiming to improve DG operational efficiency, as quantified by a generic optimal reactive power flow (ORPF) problem, we propose a two-stage approach. The first stage involves learning the manifold of optimal operating points determined by an ORPF instance. To synthesize local Volt/Var controllers, the learning task is partitioned into learning local surrogates (one per DER) of the optimal manifold with voltage input and reactive power output. Since these surrogates characterize efficient DG operating points, in the second stage, we develop local control schemes that steer the DG to these operating points. We identify the conditions on the surrogates and control parameters to ensure that the locally acting controllers collectively converge, in a global asymptotic sense, to a DG operating point agreeing with the local surrogates. We use neural networks to model the surrogates and enforce the identified conditions in the training phase. AC power flow simulations on the IEEE 37-bus network empirically bolster the theoretical stability guarantees obtained under linearized power flow assumptions. The tests further highlight the optimality improvement compared to prevalent benchmark methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Two-way coupled particle-turbulence interaction: Effect of numerics and resolution on fluid and particle statistics

Euler-Lagrange point-particle simulation has emerged as a premier methodology for studying dispersed particle-laden flows. This method's popularity stems from its ability to resolve fine-scale fluid structures while also tracking individual particles at reduced cost using an appropriate particle acceleration model. However, the point-particle model has known convergence issues in that refinement of the fluid grid can lead to changes in the predicted statistics. The reasons for non-convergence are twofold: the point-particle two-way coupling force in the Navier-Stokes equations requires a numerical regularization and, without careful implementation, yields a singular force on the fluid with grid refinement. The second factor that yields grid-dependent statistics is that the point-particle force model in general depends on the undisturbed fluid velocity. When the undisturbed fluid velocity is not robustly modeled in a grid-insensitive way, the calculated force for both particles and fluid will be grid-dependent, contaminating their respective statistics. While the first issue regarding regularizing the point-particle source term has received attention in the literature, the consequences of robustly modeling the undisturbed velocity in the context of grid refinement of turbulence has received little attention. Here, we consider decaying homogeneous isotropic turbulence laden with particles at different Stokes numbers. For a given Stokes number, we systematically refine the grid and demonstrate that explicitly modeling the undisturbed fluid velocity yields relative grid insensitivity for the energy of the particle and fluid phases, as well as acceleration of the particles. We also demonstrate that an appropriately defined dissipation rate is also grid-insensitive when an undisturbed fluid velocity correction is used. In contrast, when the undisturbed fluid velocity is modeled using the conventional approach of interpolating the local fluid velocity to the particle location, we show this procedure yields divergent statistics with grid refinement. In particular, we show that higher-order interpolation of the fluid velocity in two-way coupled problems is worse than lower-order interpolation, in the absence of a correction procedure to estimate the undisturbed fluid velocity. We also examine velocity derivative statistics of the fluid phase and demonstrate that these statistics are not in general convergent even when the undisturbed fluid velocity is explicitly modeled. Collectively, the observations in this paper are used to present a philosophy on the types of questions which are answerable with point-particle methods.

42 ENGINEERING↗

Feedback Power Cost Optimization in Power Distribution Networks with Prosumers

Here, we propose a feedback control approach for solving optimal power flow (OPF) problems in power distribution networks (DNs) based on a projected gradient scheme, where the cost is given by the sum of functions of local power injections. This approach does not require detailed knowledge of the grid model and enables real-time tracking of the optimal generation configuration. Moreover, the communication burden is minimal: only a broadcast from a central entity, called the Network Supervisor (NS), to the agents in the network is needed. Hence, agents do not have to share local information that can be sensitive, e.g., their power injections or the value of the local costs. Our approach is then used to solve a particular OPF problem targeting DNs with high penetration of distributed energy resources (DERs) in which the energy cost is given by the remuneration that the DERs owners receive for the service they provide.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Prediction of the oscillating incompressible aerodynamics of a loaded airfoil cascade by a locally analytical method

A complete first order model is developed to predict the oscillating incompressible aerodynamics of an airfoil cascade, including the effects of steady loading. The cascade steady and unsteady flow fields are analyzed by considering a periodic flow channel. The velocity potential is separated into steady and unsteady harmonic components each of which is described by a Laplace equation. An analytical solution in individual grid elements of a body fitted computational grid is then determined, with the complete solution obtained by assembling these local solutions. The capabilities and validity of this model and solution technique are demonstrated by considering the steady and unsteady aerodynamics of both theoretical and experimental cascade configurations.

Chiang, Hsiao-Wei D.↗

Demonstration of a Novel Technology to Manage Electricity Demand in Grid-Independent Military Microgrids

This research was conducted by the National Renewable Energy Laboratory (NREL) in collaboration with the S&C Electric Inc. through funding provided by the ESTCP. The project demonstrates use of cybersecure Automated Demand Response (ADR) technology to effectively manage microgrid loads during grid-independent, also known as "islanded," operation. When military microgrids become isolated from the main electrical grid, they are required to balance electricity supply and demand locally. Given that local generation may be constrained, the prevailing strategy involves shedding all but the most critical loads by tripping smart circuit breakers, which then necessitate manual resetting. This approach is generally implemented at the building level, which means that the buildings with mission-critical activities are exempt from load management and remain fully powered, whereas those deemed non-critical can experience a complete loss of service. In this research we developed a method that allows building automation systems to selectively control their assets in response to load shedding request from a microgrid controller, avoiding total loss of service in contrast to the conventional control approach. A commercial OpenADR client server by GridFabric is used for communication between the microgrid controller and the building management system (BMS). The microgrid controller monitors both generation capacity and various assets within the microgrid and issues a demand reduction request when necessary. This request is communicated to the OpenADR server via Modbus. Upon receiving the request, the OpenADR server forwards it to the BMS utilizing the OpenADR protocol. The BMS is pre-configured with various levels of load reduction strategies based on the controllable assets available, allowing for a nuanced approach to demand reduction. Both lab and field tests were performed that considered load shedding needed to achieve closed transition into island mode and to accommodate changing loads and power source availability while islanded. A commercial microgrid controller was used for these tests with normal programming within the expected constraints of the system capabilities. That is, the solution did not require any specialized modification to the code base of the controller. Given the latency of the round-trip communication path between the microgrid controller and the various devices involved with the load shed processes, there are certain scenarios for which the demonstrated solution are appropriate and some which are not. The methods described in this report can be used for load shedding/restoration during transitions between islanded and grid-tied modes of operation, as well as accommodating normal variations in load and the need to remove a power source from operation for maintenance. These methods should not be used for scenarios that require load shedding within a second or two such as sudden and unanticipated significant load increases or loss of power sources through equipment faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using System Dynamics to Define, Study, and Implement Smart Control Strategies on the Electric Power Grid

The United States electric power grid is the most complex and expansive control system in the world. Local generation control occurs at individual units based on response time and unit economics, larger regional control coordinates unit response to error conditions, and high level large-area regional control is ultimately administered by a network of humans guided by economic and resiliency related factors. Under normal operating conditions, the grid is a relatively slow moving entity that exhibits high inertia to outside stimuli, and behaves along repeatable diurnal and seasonal patterns. However, that paradigm is quickly changing because of the increasing implementation of renewable generation sources. Renewable generators by nature cannot be tightly controlled or scheduled. They appear like a negative load to the system with all of the variability associated with load on a larger scale. Also, grid-reactive loads (i.e. smart devices) can alter their consumption based on price or demand rules adding more variability to system behavior. This paper demonstrates how a systems dynamic modeling approach capable of operating over multiple time scales, can provide valuable insight into developing new “smart-grid” control strategies and devices needed to accommodate renewable generation and regulate the frequency of the grid.

14 SOLAR ENERGY↗

FORMATION OF SOLAR FILAMENTS BY STEADY AND NONSTEADY CHROMOSPHERIC HEATING

It has been established that cold plasma condensations can form in a magnetic loop subject to localized heating of its footpoints. In this paper, we use grid-adaptive numerical simulations of the radiative hydrodynamic equations to investigate the filament formation process in a pre-shaped loop with both steady and finite-time chromospheric heating. Compared to previous works, we consider low-lying loops with shallow dips and use a more realistic description for radiative losses. We demonstrate for the first time that the onset of thermal instability satisfies the linear instability criterion. The onset time of the condensation is roughly {approx}2 hr or more after the localized heating at the footpoint is effective, and the growth rate of the thread length varies from 800 km hr{sup -1} to 4000 km hr{sup -1}, depending on the amplitude and the decay length scale characterizing this localized chromospheric heating. We show how single or multiple condensation segments may form in the coronal portion. In the asymmetric heating case, when two segments form, they approach and coalesce, and the coalesced condensation later drains down into the chromosphere. With steady heating, this process repeats with a periodicity of several hours. While our parametric survey confirms and augments earlier findings, we also point out that steady heating is not necessary to sustain the condensation. Once the condensation is formed, it keeps growing even after the localized heating ceases. In such a finite-heating case, the condensation instability is maintained by chromospheric plasma that gets continuously siphoned into the filament thread due to the reduced gas pressure in the corona. Finally, we show that the condensation can survive the continuous buffeting of perturbations from photospheric p-mode waves.

79 ASTRONOMY AND ASTROPHYSICS↗

Minimization of Impact from Electric Vehicle Supply Equipment to the Electric Grid Using a Dynamically Controlled Battery Bank for Peak Load Shaving

This research presents a comparison of two control systems for peak load shaving using local solar power generation (i.e., photovoltaic array) and local energy storage (i.e., battery bank). The purpose is to minimize load demand of electric vehicle supply equipment (EVSE) on the electric grid. A static and dynamic control system is compared to decrease demand from EVSE. Static control of the battery bank is based on charging and discharging to the electric grid at fixed times. Dynamic control, with 15-minute resolution, forecasts EVSE load based on data analysis of collected data. In the proposed dynamic control system, the sigmoid function is used to shave peak loads while limiting scenarios that can quickly drain the battery bank. These control systems are applied to Oak Ridge National Laboratory s (ORNL) solar-assisted electric vehicle (EV) charging stations. This installation is composed of three independently grid-tied sub-systems: (1) 25 EVSE; (2) 47 kW photovoltaic (PV) array; and (3) 60 kWh battery bank. The dynamic control system achieved the greatest peak load shaving, up to 34% on a cloudy day and 38% on a sunny day. The static control system was not ideal; peak load shaving was 14.6% on a cloudy day and 12.7% on a sunny day. Simulations based on ORNL data shows solar-assisted EV charging stations combined with the proposed dynamic battery control system can negate up to 89% of EVSE load demand on sunny days.

Battery Management Systems↗

Grid-independent upwind scheme for multidimensional flow

Recent advances in the development of a grid-independent finite volume scheme for the Euler equations of gas dynamics are described. In the proposed method, flowfield gradient data are reconstructed locally (on a triangle) using five elementary planar waves, and an upwind numerical flux function for grid-oblique waves is developed to model the effect of the passage of these waves on the data in a cell. Numerical examples for several two-dimensional test problems are included. These results show high wave resolution and nearly monotone strong-wave transitions.

Parpia, Ijaz H.↗

Comparison of Distributive Consensus Algorithms for AnomalyDetection on the Power-Grid

As an increasing number of devices in the power-grid rely on high-precision clocks to measure electrical properties and time stamp data, GPS receivers have become a vulnerability on the power-grid. GPS spoofing attacks, in which a fake signal is transmitted, can cause sensor measurement errors that can misinform protective equipment and grid operators for both the transmission and distribution grid. The technology being developed to secure precision clocks in the transmission grid are not appropriate for the distribution grid. Thus, there is a need to developed anomaly detection algorithms that are suitable for the hardware available on the distribution grid. Traditionally, a distributed detection framework is comprised of spatially distributed nodes which acquire observations about a quantity of interest and sends the data to the fusion center, where a global decision is made. Instead the distribution grid has low-power devices, such as smart inverters and microPMUs, that could be used to perform highly parallelized calculations. Having on node calculations is beneficial since it is more network and computation efficient, as the more calculations can be performed where the data is being captured instead of communicating across a slow network to a centralized fusion center. Instead, we could employ an alternate peer-to-peer type of information exchange on the distribution grid that can still reach a global decision. A decentralized approach to anomaly detection makes efficient use of the computational and network bandwidth that exists, and it also lacks the single point of failure of a centralized approach. Thus, a decentralized local information exchange and/or inference is preferred. Lastly, the unreliability of the distribution grid network connections and potential noise or error in the measurements must be considered. In order to produce an effective detection tool, a Byzantine-fault tolerant and asynchronous algorithm must be developed. Thus, the first phase of our project is to develop a distributed, decentralized, asynchronous, Byzantine-fault tolerant, collaborative autonomy-based anomaly detection algorithm to collectively analyze clusters of data for signs of a malicious attack.

97 MATHEMATICS AND COMPUTING↗

Network-Cognizant Voltage Droop Control for Distribution Grids

Our paper examines distribution systems with a high integration of distributed energy resources (DERs) and addresses the design of local control methods for real-time voltage regulation. Particularly, the paper focuses on proportional control strategies where the active and reactive output-powers of DERs are adjusted in response to (and proportionally to) local changes in voltage levels. The design of the voltage-active power and voltage-reactive power characteristics leverages suitable linear approximation of the AC power-flow equations and is network-cognizant; that is, the coefficients of the controllers embed information on the location of the DERs and forecasted non-controllable loads/injections and, consequently, on the effect of DER power adjustments on the overall voltage profile. We pursued a robust approach to cope with uncertainty in the forecasted non-controllable loads/power injections. Stability of the proposed local controllers is analytically assessed and numerically corroborated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improvements of the magnetic field design for SPIDER and MITICA negative ion beam sources

The design of the magnetic field configuration in the SPIDER and MITICA negative ion beam sources has evolved considerably during the past four years. This evolution was driven by three factors: 1) the experimental results of the large RF-driven ion sources at IPP, which have provided valuable indications on the optimal magnetic configurations for reliable RF plasma source operation and for large negative ion current extraction, 2) the comprehensive beam optics and heat load simulations, which showed that the magnetic field configuration in the accelerator is crucial for keeping the heat load due to electrons on the accelerator grids within tolerable limits, without compromising the optics of the negative ion beam in the foreseen operating scenarios, 3) the progress of the detailed mechanical design of the accelerator, which stimulated the evaluation of different solutions for the correction of beamlet deflections of various origin and for beamlet aiming. On this basis, new requirements and solution concepts for the magnetic field configuration in the SPIDER and MITICA beam sources have been progressively introduced and updated until the design converged. The paper presents how these concepts have been integrated into a final design solution based on a horizontal “long-range” field (few mT) in combination with a “local” vertical field of some tens of mT on the acceleration grids.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

What was Learned from Numerical Simulations of F-16XL (CAWAPI) at Flight Conditions

Nine groups participating in the CAWAPI project have contributed steady and unsteady viscous simulations of a full-scale, semi-span model of the F-16XL aircraft. Three different categories of flight Reynolds/Mach number combinations were computed and compared with flight-test measurements for the purpose of code validation and improved understanding of the flight physics. Steady-state simulations are done with several turbulence models of different complexity with no topology information required and which overcome Boussinesq-assumption problems in vortical flows. Detached-eddy simulation (DES) and its successor delayed detached-eddy simulation (DDES) have been used to compute the time accurate flow development. Common structured and unstructured grids as well as individually-adapted unstructured grids were used. Although discrepancies are observed in the comparisons, overall reasonable agreement is demonstrated for surface pressure distribution, local skin friction and boundary velocity profiles at subsonic speeds. The physical modeling, be it steady or unsteady flow, and the grid resolution both contribute to the discrepancies observed in the comparisons with flight data, but at this time it cannot be determined how much each part contributes to the whole. Overall it can be said that the technology readiness of CFD-simulation technology for the study of vehicle performance has matured since 2001 such that it can be used today with a reasonable level of confidence for complex configurations.

Rizzi, Arthur↗

Optimal local truncation error method for 3-D elasticity interface problems

The paper deals with a new effective numerical technique on unfitted Cartesian meshes for simulations of heterogeneous elastic materials. Here, we develop the optimal local truncation error method (OLTEM) with 27- point stencils (similar to those for linear finite elements) for the 3-D time-independent elasticity equations with irregular interfaces. Only displacement unknowns at each internal Cartesian grid point are used. The interface conditions are added to the expression for the local truncation error and do not change the width of the stencils. The unknown stencil coefficients are calculated by the minimization of the local truncation error of the stencil equations and yield the optimal second order of accuracy for OLTEM with the 27-point stencils on unfitted Cartesian meshes. A new post-processing procedure for accurate stress calculations has been developed. Similar to basic computations it uses OLTEM with the 27-point stencils and the elasticity equations. The post-processing procedure can be easily extended to unstructured meshes and can be independently used with existing numerical techniques (e.g., with finite elements). Numerical experiments show that at an accuracy of 0.1% for stresses, OLTEM with the new post-processing procedure significantly (by 10 5 -10 9 times) reduces the number of degrees of freedom compared to linear finite elements. OLTEM with the 27-point stencils yields even more accurate results than high-order finite elements with wider stencils.

42 ENGINEERING↗

A Society of Devices: Integrating Intelligent Distributed Resources with Transactive Energy

Secure, Clean and Efficient Energy is one of the great societal challenges of our time. Electricity as a sustainable energy carrier plays a central role in the most effective transition scenarios towards sustainability. To harness this potential, the current electricity infrastructure needs to be rigorously re-engineered into an integrated and intelligent electricity system: the smart grid. Key elements of the smart grid vision are the coordination mechanisms. In such a system, vast numbers of devices, currently just passively connected to the grid, will become actively involved in system-wide and local coordination tasks. In this light, transactive energy (TE) is emerging as a strong contender for orchestrating the coordinated operation of so many devices.

Transactive↗

Advanced Research Projects Agency - Energy Annual Report for FY 2015

This report presents a summary of the activities of the Advanced Research Projects Agency-Energy (ARPA-E) during Fiscal Year 2015 (FY 2015). In FY 20151, ARPA-E selected projects for nine new programs covering a broad array of energy technologies, including: 30 million dollars for low-cost tools to aid in the future development of fusion power (ALPHA); 30 million dollars for new power plant cooling technologies that enable high thermal-to-electric energy conversion efficiency with zero net water dissipation to the atmosphere (ARID); 6 million dollars for validation of the performance of ARPA-E-funded grid-storage technologies (CHARGES); 30 million dollars for systems for localized thermal management to improve building efficiency (DELTA); 25 million dollars for development of generator technologies to enable more affordable and efficient residential Combined Heat and Power (CHP) systems (GENSETS); 30 million dollars for low-cost, highly sensitive systems to detect methane emissions (MONITOR); 24 million dollars for micro-scale concentrated photovoltaic systems (MOSAIC); 30 million dollars to integrate agriculture, information technology and engineering to develop crops that are sustainable, affordable and yield abundant plant feedstocks for bioenergy (TERRA); 14.5 million dollars for systems to identify less energy-intense travel options for users using software accessible on smartphones or other communications devices (TRANSNET).

24 POWER TRANSMISSION AND DISTRIBUTION↗