Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Demonstration of automated price response in large customers in New York City using Auto-DR and OpenADR

Demand response (DR) – allowing customers to respond to reliability requests and market prices by changing electricity use from their normal consumption pattern – continues to be seen as an attractive means of demand-side management and a fundamental smart-grid improvement that links supply and demand. From October 2011 to December 2013, the Demand Response Research Center at Lawrence Berkeley National Laboratory, the New York State Energy Research and Development Authority, and partners Honeywell and Akuacom, have conducted a demonstration project enabling Automated Demand Response (Auto-DR) in large commercial buildings located in New York City using Open Automated Demand Response (OpenADR) communication protocols. In particular, this project focuses on demonstrating how the OpenADR platform, enabled by Akuacom, can automate and simplify interactions between buildings and various stakeholders in New York State and enable the automation of customers’ price response to yield bill savings under dynamic pricing. In this paper, the cost control opportunities under day-ahead hourly pricing and Auto-DR control strategies are presented for four demonstration buildings; present the breakdown of Auto-DR enablement costs; summarize the field test results and their load impact; and show potential bill savings by enabling automated price response under Consolidated Edison’s Mandatory Hourly Pricing (MHP) tariff. For one of the sites, the potential bill savings at the site’s current retail rate are shown. Facility managers were given granular equipment-level opt-out capability to ensure full control of the sites during the Auto-DR implementation. The expected bill savings ranged from 1.1% to 8.0% of the total MHP bill. The automation and enablement costs ranged from $70 to $725 per kW shed. The results show that OpenADR can facilitate the automation of price response, deliver savings to the customers and opt-out capability of the implementation retains control of the sites by facility managers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Uranium Oxide Elutriation at Higher Flow Rates and Longer Times

This work supports the recovery of high-assay low-enriched uranium (i.e., U enriched in 235 U to >5% and <20%) from used nuclear fuel. One step includes elutriating triuranium octoxide (U 3 O 8 ) from a fluidized bed of alumina (Al 2 O 3 ) that fills the main reaction chamber. The experiments outlined in this report assessed the effects of the time and flow rate on the elutriation of U 3 O 8 powder from the reaction vessel. Testing at Oak Ridge National Laboratory (ORNL) was performed in a one-fourth scale experimental apparatus based on a pilot-scale system, which is the Material Recovery Pilot Plant (MRPP) at Idaho National Laboratory (INL). The experimental system comprises a supply of pressurized nitrogen (N 2 ), a gas heater, the reaction vessel, a knock-out pot, and a water trap where elutriated particles are collected for sampling. An Al 2 O 3 fluidized bed is contained within the reaction vessel. A bed of Al 2 O 3 with a nominal size of 180 µm and U 3 O 8 with a nominal size of 7 µm was fluidized at 2 different flow rates so the U 3 O 8 physically separated from the bed. The apparatus was simple and had no valves or sharp bends downstream from the reactor. The flow exited the reactor through a side port at the top. The flow passed through a knock-out vessel before the flow was passed through a bubbler to capture the U 3 O 8 . Seven tests were completed with U 3 O 8 using an elutriating gas of N 2 heated to 200°C. Tests were performed with bed loadings that comprise 25.0 g of U 3 O 8 , or 3.6 wt% of the bed mass. Except for one test performed at 12 SLPM, the gas flow rate through the bed for the other experiments was set at 10 SLPM as measured by the mass flow meter. Linear velocities through the bed were calculated as 28 and 34 cm/s, or 0.9 and 1.1 ft·s -1 . The duration of the tests ranged from 20 to 180 min, and one test had a flow cycled between 0 and 5 SLPM every 5 min for 40 min. The testing successfully demonstrated elutriation of U 3 O 8 from the fluidized bed as up to a 100% of the U 3 O 8 was transferred out of the bed. The removal of U 3 O 8 had a logarithmic dependence on flow rate. The design changes made the apparatus easier to clean, and the mass balances were better than those used in previous studies. Some elutriated Al 2 O 3 collected in the tubing that connected the reactor to the knock-out pot, but the amount of Al 2 O 3 was minimal for 10 SLPM. The flow at 12 SLPM showed considerable transport of Al 2 O 3 bed material into the reaction-vessel headspace and the transfer line to the knock-out pot.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sister Rod Destructive Examinations (FY23): Appendix H: Instron Uncertainty Calculations

This document discusses the uncertainty of measurements associated with the Instron system and the resulting uncertainty in the acquired measurements and calculated information. The primary parameters measured during the Instron test include the applied load and specimen deflection. The associated primary calculated parameters are the maximum beam deflection at the rod’s axial center and modulus of elasticity. Secondary calculated parameters include specimen stress and strain amplitudes, as well as flexural rigidity. The uncertainty associated with the primary and secondary calculated parameters was investigated based on the known uncertainty in the measured parameters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Q2 Report for FY25 Theory and Simulation Performance Target: Development of an integrated modeling framework for fusion reactor design and assessment

This report describes the work and activities carried out towards the completion of each of the following milestones in FY25 Q2: 1. Demonstrate workflow for generating self-consistent CESOL plasma profiles + first wall and divertor loading prediction and generate the CAT plasma and neutron loading needed for further engineering analysis: $\circ$ Run CESOL with BOUT++/Hermes-3 and immersed boundary condition to directly map to wall: • Run BOUT++/Hermes-3 through the IPS workflow to find radial particle and energy diffusivities to match either the Eich or the physics-based scaling of the SOL heat flux width, and • Expand source of first wall heat flux to include charged particles, neutrals, and radiation from the core+edge. 2. Generate medium fidelity parametrized CAD: $\circ$ Develop the TRACER tool to read an existing CAD, regenerate the geometry based on vertex location and connectivity information, define vertex translation and parameters needed for scaling the CAD, and $\circ$ Utilize the FreeGS code to determine CAT PF coil placement, including minimizing the number of coils, coil current, and electromechanical stresses. 3. Utilize plasma loading for engineering analysis: $\circ$ Couple the plasma loading to input for OpenFOAM and demonstrate initial test of thermal analysis of CAT first wall loading with typical DCLL blanket component cooling boundary conditions. 4. Demonstrate nuclear analysis: $\circ$ Apply initial analysis of tritium transport in DCLL blanket by evaluating spatially resolved tritium generation rates, tritium diffusion and convection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Towards a Unified Low-Cost Flow Plate, Flow-Field, PTL Solution for Proton Exchange Membrane Electrolyzers

Proton exchange membrane (PEM) water electrolysis is a highly efficient method for hydrogen production. Research cells typically consist of one proton exchange membrane, two catalyst layers, two porous transport layers, two flow-field plates, and two endplates. In commercial systems, the machined flow-field plates that are employed in research cells are typically replaced by stamped parts or open mesh material solutions to reduce manufacturing cost at scale. Nonetheless, the cell contains about 8 total interfaces: bipolar plate / flow plate material / porous transport medium / electrode / membrane / electrode / porous transport medium / flow plate material / bipolar plate. All these materials and interfaces need to be optimized for maximum performance and efficiency. Reducing the amount of interfaces by combining individual cell components directly benefits the fabrication cost (by reducing the parts count and the needs for surface coatings) and the electrochemical performance (by reducing ohmic losses). We have designed a novel PEM electrolysis cell with a piece of channeled titanium felt functioning as both the anode flow-field and the PTL, referred to as the channeled diffusion layer (CDL). The pores of the felt facilitate both in-plane and through-plane diffusion, ensuring maximum catalyst utilization while also minimizing mass transport loss. The titanium felt can be mass manufactured with existing stamping and forming methods and is therefore a promising candidate to reduce the capital cost of PEM electrolyzers whilst improving hydrogen production efficiency. Experiments conducted with 3mg IrOx/cm2 loading MEAs have shown a approximately 40% boost in peak current by implementing the CDL design. Low catalyst-loading MEAs are being tested in ongoing experiments and their results will be discussed and compared.

08 HYDROGEN↗

Commissioning report of the MuCool 5 Tesla solenoid coupled with helium refrigerator

MuCool 5T solenoid was successfully cooled down and operated coupled with MTA 'Brown' refrigerator. The system performed as designed with substantial performance margin. All process alarms and interlocks, as well as ODH and fire alarms, were active and performed as designed. The cooldown of the refrigerator started from warm conditions and took 44 hours to accumulate liquid helium level and solenoid temperature below 5K. Average liquid nitrogen consumption for the refrigerator precool and solenoid shield was measured as 20 gal/hr (including boil-off). Helium losses were small (below 30 scfh). The system was stable and with sufficient margin of performance and ran stably without wet expansion engine. Quench response demonstrated proper operation of the relieving devices and pointed to necessity of improving tightness of the relieving manifolds. Boil-off test demonstrated average heat load of 3 Watts for the unpowered solenoid. The solenoid can stay up to 48 hours cold and minimally filled if the nitrogen shield is maintained. A list of improvements includes commencing into operations the second helium compressor and completion of improvements and tune-ups for system efficiency.

43 PARTICLE ACCELERATORS↗

Clinical Features of and Risk Factors for Fatal Ebola Virus Disease, Moyamba District, Sierra Leone, December 2014–February 2015

The current outbreak of Ebola virus disease (EVD) in West Africa has infected more than 28,000 people, killed more than 11,000 and disrupted social life. We studied retrospectively the clinical presentation and risk factors for fatal outcome among the 31 Ebola virus (EBV) positive patients admitted to the Ebola Treatment Center (ETC) in Moyamba District, Sierra Leone. We found a higher rate of bleeding manifestations than reported elsewhere during the current outbreak. Significant predictors for fatal outcome were shorter time from onset to admission, male sex, high viral load on initial lab test, severe pain, diarrhea, bloody stools, and development of other bleeding manifestations during hospital admission. Awareness of risk factors for fatal outcome could be used to identify patients in need of more intensive medical support. The lack of fever in as much as a third of EVD cases may have implications for temperature screening practices and case definitions.

60 APPLIED LIFE SCIENCES↗

Dynamic Deformation in Nuclear Graphite and Underlying Mechanisms

Time-dependent deformation in nuclear graphite is influenced by the creation and migration of radiation-induced defects in the reactor environment. This study investigates the role of pre-existing defects such as point defect clusters and Mrozowski cracks in nuclear graphite IG-110. Separate specimens were irradiated with a 2.8 MeV Au 2+ beam with a fluence of 4.38 × 10 14 cm −2 and an 8 MeV C 2+ beam with a fluence of 1.24 × 10 16 cm −2 . Microscopic specimens were either mechanically loaded inside a transmission electron microscope (TEM) or subjected to ex situ indentation-based creep loading. In situ TEM tests showed significant plasticity in regions highly localized around the Mrozowski cracks, resembling slip or ripplocation bands. Slip bands were also seen near regions without pre-existing defects but at very high stresses. Ex situ self-ion irradiation embrittled the specimens and decreased the creep displacement and rate, while heavy ion irradiation resulted in the opposite behavior. We hypothesize that the large-sized gold ions (compared to the carbon atoms) induced interplanar swelling as well as cross-plane channels for increased defect mobility. These findings illustrate the role of pre-existing defects in the dynamic relaxation of stresses during irradiation and the need for more studies into the radiation environment’s impact on the mechanical response of nuclear graphite.

creep deformation↗

Resistance Spot Weld Failure Mode and Weld Performance for Aluminium Alloys

In this chapter, we present the strength and failure modes of reactive NanoFoil® bonded joints for similar and dissimilar lightweight materials. NanoFoil® is a multi-layer foil fabricated through the growth of thousands of nanoscale layers of aluminum and nickel by vapor deposition. Initiated by an energy impulse, the like-like bonds of the atoms of each layer in the foil are exchanged for more stable unlike bonds between atoms from neighboring layers. As the atoms of each layer mix, heat is generated, creating a self-sustaining reaction traveling along the length of the foil. The instantaneous release of heat energy by this reaction is controlled by the nanolayer thickness and lay-up, such that accurate control of a highly localized heat source can be realized, allowing bonding without compromising the properties/integrities of the base materials. First, solder and braze joints for similar and dissimilar material combinations of steel, aluminum and magnesium are fabricated. Static bond strength tests under tensile shear loading condition are then performed to quantify the bond strength for different material combinations. The through-thickness microstructure changes and modifications by the bonding process are quantified using SEM. Depending on the base material combinations, it is shown that the nanofoil bond strength is comparable to those of the conventional structural adhesive bonds.

36 MATERIALS SCIENCE↗

NESC-VII: Fracture Mechanics Analyses of WPS Experiments on Large-scale Cruciform Specimen

This paper describes numerical analyses performed to simulate warm pre-stress (WPS) experiments conducted with large-scale cruciform specimens within the Network for Evaluation of Structural Components (NESC-VII) project. NESC-VII is a European cooperative action in support of WPS application in reactor pressure vessel (RPV) integrity assessment. The project aims in evaluation of the influence of WPS when assessing the structural integrity of RPVs. Advanced fracture mechanics models will be developed and performed to validate experiments concerning the effect of different WPS scenarios on RPV components. The Oak Ridge National Laboratory (ORNL), USA contributes to the Work Package-2 (Analyses of WPS experiments) within the NESCVII network. A series of WPS type experiments on large-scale cruciform specimens have been conducted at CEA Saclay, France, within the framework of NESC VII project. This paper first describes NESC-VII feasibility test analyses conducted at ORNL. Very good agreement was achieved between AREVA NP SAS and ORNL. Further analyses were conducted to evaluate the NESC-VII WPS tests conducted under Load-Cool-Transient- Fracture (LCTF) and Load-Cool-Fracture (LCF) conditions. This objective of this work is to provide a definitive quantification of WPS effects when assessing the structural integrity of reactor pressure vessels. This information will be utilized to further validate, refine, and improve the WPS models that are being used in probabilistic fracture mechanics computer codes now in use by the NRC staff in their effort to develop risk-informed updates to Title 10 of the U.S. Code of Federal Regulations (CFR), Part 50, Appendix G.

99 GENERAL AND MISCELLANEOUS↗

Performance of the Westinghouse WWER-1000 fuel design

In 2005 six (6) Westinghouse WWER-1000 Lead Test Assemblies (LTAs) were loaded in the South Ukraine Unit 3. This design has demonstrated full compatibility with resident fuel designs and all associated fuel handling and reactor components. Operations have further demonstrated adequacy of performance margins and the reliability requirements for multiple cycles of operation. The LTAs have now been discharged after completing the planned four cycles of operation and having reached an average assembly burnup in excess of 43 MWd/kgU. Results and concluding remarks from the post irradiation examination is provided in this paper.

Hoglund, J↗

Technology Solutions Case Study: Cladding Attachment Over Thick Exterior Insulating Sheathing

The addition of insulation to the exterior of buildings is an effective means of increasing the thermal resistance of wood-framed walls and mass masonry wall assemblies. Insulation on the exterior of the structure has many direct benefits, including better effective R-value from reduced thermal bridging, better condensation resistance, reduced thermal stress on the structure, as well as other commonly associated improvements such as increased airtightness and improved water management. Although the approach has proven effective, there is resistance to its widespread implementation due to a lack of research and understanding of the mechanisms involved in the development of the vertical displacement resistance capacity. In addition, the long-term in-service performance of the system has been questioned due to potential creep effects of the assembly under the sustained dead load of the cladding and effects of varying environmental conditions. In addition, the current International Building Code (IBC) and International Residential Code (IRC) do not have a provision that specifically allows this assembly. In this project, researchers from Building Science Corporation, a Building America team, investigated these issues to better understand the mechanics behind this method of cladding attachment

BSC↗

NWTC Researchers Field-Test Advanced Control Turbine Systems to Increase Performance, Decrease Structural Loading of Wind Turbines and Plants

Researchers at the National Renewable Energy Laboratory's (NREL's) National Wind Technology Center (NWTC) are studying component controls, including new advanced actuators and sensors, for both conventional turbines as well as wind plants. This research will help develop innovative control strategies that reduce aerodynamic structural loads and improve performance. Structural loads can cause damage that increase maintenance costs and shorten the life of a turbine or wind plant.

17 WIND ENERGY↗

Spherical nanoindentation stress-strain analysis, Version 1

Nanoindentation is a tool that allows the mechanical response of a variety of materials at the nano to micron length scale to be measured. Recent advances in spherical nanoindentation techniques have allowed for a more reliable and meaningful characterization of the mechanical response from nanoindentation experiments in the form on an indentation stress-strain curve. This code base, Spin, is written in MATLAB (The Mathworks, Inc.) and based on the analysis protocols developed by S.R. Kalidindi and S. Pathak [1, 2]. The inputs include the displacement, load, harmonic contact stiffness, harmonic displacement, and harmonic load from spherical nanoindentation tests in the form of an Excel (Microsoft) spreadsheet. The outputs include indentation stress-strain curves and indentation properties as well their variance due to the uncertainty of the zero-point correction in the form of MATLAB data (.mat) and figures (.png). [1] S. Pathak, S.R. Kalidindi. Spherical nanoindentation stress–strain curves, Mater. Sci. Eng R-Rep 91 (2015). [2] S.R. Kalidindi, S. Pathak. Determination of the effective zero-point and the extraction of spherical nanoindentation stress-strain curves, Acta Materialia 56 (2008) 3523-3532.

Weaver, Jordan S.↗

Transient Mechanical Test Development for Accident Tolerant Cladding Candidates to Simulate PCMI-like Conditions

This study investigates the transient mechanical response of accident tolerant fuel (ATF) cladding candidates to provide information on potential PCMI-induced deformation and failure of candidate cladding materials. The mechanical testing is applied t to Gen-I FeCrAl and triaxially-braided SiC fiber SiC matrix composite materials under loading conditions like the PCMI during a postulated design basis reactivity insertion accident. To achieve the specific loading conditions, a modified burst test instrument with accurate mechanical pulse control has been designed and constructed. The mechanical response of FeCrAl, SiC-SiC composite tubes were compared with the pre-hydrided zirconium alloy cladding. The specimens subjected to mechanical pulses were investigated in a strain-controlled manner deformation.

Cinbiz, Nedim↗

Grips for testing of electrical characteristics of a specimen under a mechanical load

Various technologies to facilitate coupled electrical and mechanical measurement of conductive materials are disclosed herein. A gripping device simultaneously holds a specimen in place and causes contact to be made between the specimen and a plurality of electrodes connected to an electrical measuring device. An electrical characteristic of the specimen is then measured while a mechanical load is applied to the specimen, and a relationship between the mechanical load and changes in the electrical characteristic can be identified.

47 OTHER INSTRUMENTATION↗