Cost Assessment of Building Envelope Retrofits

About 65% of US buildings were constructed before the Department of Energy established the Building Energy Codes Program in 1992; therefore, their envelopes are likely significant contributors to heating and cooling loads. Numerous techniques to improve the thermal, airtightness, and water tightness performance of existing envelopes have been explored; however, these tend to be lengthy and disruptive because most of the material assembly occurs at the job site. Overclad panels that are fabricated offsite and include most of the envelope components are a potential mechanism to reduce construction time and minimize disturbance to building occupants. These benefits have been demonstrated by European programs such as Energiesprong and MORE-CONNECT, as well as a few case studies in the US. Nevertheless, preliminary evaluations appear to indicate that overclad panels may be too costly to be implemented in the US. This paper summarizes cost estimates, strengths and weaknesses from several envelope retrofit techniques; assesses the feasibility of overclad panels in the US; and proposes methods, such as advanced manufacturing techniques, that could decrease the cost of building envelope retrofits.

Salonvaara, Mikael↗

An Efficient Annual-Performance Model of a Geothermal Network for Improved System Design, Operation, and Control: Preprint

Geothermal district energy systems (DES), and specifically geothermal networks, provide a viable solution for decarbonizing residential and commercial heating and cooling loads. District energy systems of all kinds enable a thermal resource with a relatively high capital cost (such as a geothermal borehole field) to be shared among a large number of users. While district heating and cooling has been studied for many years, geothermal networks, fifth generation DES that utilize water-source heat pumps and an ambient temperature loop to meet heating and cooling loads, have not been implemented extensively and thus require additional technical and economic optimization to obtain maximum benefits. This paper presents a newly developed reduced-order model that captures the flow of energy within the network, including the commercial and residential users' electrical usage, at an hourly rate over a year. The model includes building loads, heat pumps, borehole fields, and auxiliary heat/cool input, all connected with an ambient-temperature thermal loop model. In the model, operational control is possible for the borehole fields, circulation pump, and auxiliary system. For a given system, the model can output the complete state parameters for each component, the thermal loop, and the collective system, such as flow rate over time, average thermal loop temperature over time, and total electricity usage. The model can also be used to optimize the system control for maximizing system efficiency or minimizing system operational cost. For example, one initial assessment of the borehole controller for an example system showed that a controller with on/off operation of the borehole field reduces annual electrical usage by 33%, compared with continuous operation mode. Hence, the model can assist in optimizing a given system's operation to get the most value out of a geothermal network installation. Future work will consider the model's application to a demonstration project, including the model validation against operational data and system operation optimization.

ambient-temperature loop↗

Advances and perspectives on mass transfer and enzymatic hydrolysis in the enzyme-mediated lignocellulosic biorefinery: A review

We report enzymatic hydrolysis is a critical process for the cellulase-mediated lignocellulosic biorefinery to produce sugar syrups that can be converted into a whole range of biofuels and biochemicals. Such a process operating at high-solid loadings (i.e., scarcely any free water or roughly ≥ 15% solids, w/w) is considered more economically feasible, as it can generate a high sugar concentration at low operation and capital costs. However, this approach remains restricted and incurs “high-solid effects”, ultimately causing the lower hydrolysis yields with increasing solid loadings. The lack of available water leads to a highly viscous system with impaired mixing that exhibits strong transfer resistance and reaction limitation imposed on enzyme action. Evidently, high-solid enzymatic hydrolysis involves multi-scale mass transfer and multi-phase enzyme reaction, and thus requires a synergistic perspective of transfer and biotransformation to assess the interactions among water, biomass components, and cellulase enzymes. Porous particle characteristics of biomass and its interface properties determine the water form and distribution state surrounding the particles, which are summarized in this review aiming to identify the water-driven multi-scale/multi-phase bioprocesses. Further aided by the cognition of rheological behavior of biomass slurry, solute transfer theories, and enzyme kinetics, the coupling effects of flow-transfer-reaction are revealed under high-solid conditions. Based on the above basic features, this review lucidly explains the causes of high-solid hydrolysis hindrances, highlights the mismatched issues between transfer and reaction, and more importantly, presents the advanced strategies for transfer and reaction enhancements from the viewpoint of process optimization, reactor design, as well as enzyme/auxiliary additive customization.

45 multi-scale, multi-phase, enzymatic reaction↗

Quasi-static and dynamic response of a Cu/Nb composite following equal channel angular extrusion

The article presents a study of the plastic properties of a Cu–18%Nb composite following equal channel angular extrusion under both low- and high-strain rate loadings. The microstructures are characterized by optical and scanning electron microscopy as well as electron backscatter diffraction. Comparisons are also made with a Cu–50%Nb laminate made by accumulative roll bonding. Textures obtained within the respective phases in the extruded composite closely mimic those previously reported for the pure components alone (Cu, Nb). Grain sizes of the major phase (Cu) exhibit broad distributions, due largely to partial recrystallization during the extrusion process. Further re-crystallization is obtained within localized deformation bands produced at high strain rates (3 × 10 3 s –1 ). While the degree of anisotropy and the strain rate sensitivity of the composite response are similar to those of pure Cu after extrusion, the strength levels of the composite are somewhat greater, falling broadly between those obtained in the pure components after extrusion to comparable plastic strains. Furthermore, the implications for selection of composite composition and processing for achieving higher strengths are briefly discussed.

36 MATERIALS SCIENCE↗

Quadratic Zeeman effect in hydrogen at 2–3 MG magnetic fields

The Zeeman effect is used for measurement of magnetic fields in astrophysical and laboratory plasmas. Magnetic fields in atmospheres of magnetic white dwarf stars are in the range 40 kG–1 GG. The quadratic Zeeman effect results in the additional split and shift of lines for magnetic fields >2 MG. Hydrogen Balmer lines were studied in magnetic fields delivered by a 1 MA pulse power generator. The magnetic field was generated by rod loads 0.8–1 mm in diameter. A droplet of CH oil on the load center was the source of hydrogen. A low ionized oil layer was backlit by blackbody emission from the rod with a temperature of 0.5–0.6 eV. Zeeman splitting of H-alpha and H-beta absorption lines were with a grating spectrometer. A spectral shift of the central component of the triplet indicated the quadratic Zeeman effect in hydrogen lines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

US HL-LHC Accelerator Upgrade Project (MQXFA Final Design Report)

The MQXFA Quadrupole magnets will be installed in High Luminosity LHC to form the Q1 and Q3 inner triplet optical elements in front of the interaction points 1 (ATLAS) and 5 (CMS). A pair of MQXFA units is assembled in a stainless steel helium vessel, including the end domes, to make the Q1 Cold Mass or the Q3 Cold Mass. The US HL LHC Accelerator Upgrade Project* is responsible for the design, manufacturing and test of the Q1/Q3 Cold Masses and the complete MQXFA magnets. CERN provides the cryostat components and is responsible for integration and installation in HL LHC. The MQXFA quadrupoles have 150 mm aperture, 4.2 m magnetic length, nominal gradient of 132.2 T/m, and coil peak field of 11.3 T. They use Nb_3Sn conductor and a support structure made of segmented aluminum shells pre-loaded by using bladders and keys. This report presents the final design of the MQXFA quadrupole magnets.

43 PARTICLE ACCELERATORS↗

A State-Space Model of an Inverter-Based Microgrid for Multivariable Feedback Control Analysis and Design

In this work, a synchronous model for grid-connected and islanded microgrids is presented. The grid-connected model is based on the premise that the reference frame is synchronized with the AC bus. The quadrature component of the AC bus voltage can be cancelled, which allows to express output power as a linear equation for nominal values in the AC bus amplitude voltage. The model for the islanded microgrid is developed by integrating all the inverter dynamics using a state-space model for the load currents. This model is presented in a comprehensive way such that it could be scalable to any number of inverter-based generators using inductor–capacitor–inductor (LCL) output filters. The use of these models allows designers to assess microgrid stability and robustness using modern control methods such as eigenvalue analysis and singular value diagrams. Both models were tested and validated in an experimental setup to demonstrate their accuracy in describing microgrid dynamics. In addition, three scenarios are presented: non-controlled model, Linear-Quadratic Integrator (LQI) power control, and Power-Voltage (PQ/Vdq) droop–boost controller. Experimental results demonstrate the effectiveness of the control strategies and the accuracy of the models to describe microgrid dynamics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimize Topology, Component Sizes, and Operating Strategy of Participant's Protype: Cooperative Research and Development Final Report

The purpose of the project was to complete testing of Shine Technologies LLC’s prototype power system called “Juicebox 3.0.” Testing of the prototype using NREL’s hardware-in-the-loop capabilities, including a DC power supply programmed to simulate PV module output and provide the JuiceBox 3.0 at the specified power level and with a load bank of sufficient capacity to mimic DC and AC loads connected to the outlets of the Juicebox 3.0. The unit is provided with SAE wire connectors. A photo of a JuiceBox 3.0 unit is shown in Figure 1 below.

14 SOLAR ENERGY↗

Autoignition of CRC diesel surrogates at low temperature combustion conditions: Rapid compression machine experiments and modeling

As federal programs require increasingly stringent engine emissions and fuel economy standards, these ambitions can only be met if next-generation combustion technology is developed focusing on high-efficiency and low-emissions engines. Recent research has indicated the need to operate engines at higher compression ratios and with low temperature combustion (LTC) to achieve the needed gains in engine efficiency and reductions in emissions. Because there is a lack of understanding of the chemistry of diesel fuel components and their mixtures at these LTC conditions, this limits the ability to develop predictive chemical kinetic models that can be used to optimize engine combustion. The current study aims to fill in gaps in fundamental combustion data on surrogate fuel mixtures relevant to diesel fuels. Specifically, four multicomponent diesel surrogates formulated by the Coordinating Research Council (CRC) to emulate an ultra-low-sulfur research-grade #2 certification diesel fuel (CFA), namely V0a (4 components), V0b (5 components), V1 (8 components), and V2 (9 components), have been investigated in a rapid compression machine (RCM) through determination of total and first-stage ignition delay times. Autoignition characteristics of lean to rich fuel/O 2 /N 2 mixtures, for the four CRC surrogates and CFA, have been measured using an RCM at LTC relevant pressures and temperatures, in the ranges of 10–20 bar and 650–1000 K, respectively. The equivalence ratios have been varied by independently changing the oxygen mole fraction and the fuel mole fraction in the test mixtures, thereby illustrating the individual effects of oxygen concentration and fuel loading on diesel autoignition. Autoignition results of these four CRC surrogates are compared among them and with those of CFA. Some degree of agreement in autoignition response between each CRC surrogate and CFA is observed, while discrepancies are also identified and discussed. In addition, a detailed chemical kinetic model for diesel surrogates has been developed and validated against these newly-acquired RCM data. We find that this model shows reasonable agreement with the overall ignition delay time results of the current RCM experiments. Chemical kinetic analyses of the developed model were further conducted to help identify the reactions controlling the autoignition processes and the consumption of fuel components in CRC surrogates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance of a Hybrid HVAC-Integrated Thermal Storage Device

Thermal equipment in buildings is a primary contributor to peak loads on the electrical grid. Thermal energy storage is a cost-effective strategy to decouple electric use from thermal loads, thus reducing grid peak costs for building owners. One method for storing thermal energy in a building is to integrate a phase change material (PCM) directly into the heating, ventilation, and air conditioning system. These systems often require additional glycol loops, pumps, valves, and heat exchangers to couple the storage to the cooling system and building space, which increases the complexity and cost. This work will discuss an alternate approach where the storage is added directly into the heat pump evaporator. A detailed two-dimensional finite difference heat transfer model of a PCM-refrigerant-glycol heat exchanger was developed to simulate the performance of this component. The fluid stream was discretized along the flow direction to capture changes in the fluid properties and local heat transfer rates, and the phase change material was discretized in both the x and y directions to capture the movement of the melt front. The model was used to understand the impact of different material and geometric properties on the charge and discharge characteristics of the device. Finally, a Ragone framework analogous to that used for electrochemical batteries was used to maximize the energy density and round-trip efficiency of the device while supplying loads appropriate for space cooling in buildings.

buildings↗

Conducting Polymers Meet Lithium–Sulfur Batteries: Progress, Challenges, and Perspectives

Lithium–sulfur (Li–S) batteries have attracted increased interest because of the high theoretical energy density, low cost, and environmental friendliness. Conducting polymers (CPs), as one of the most promising materials used in Li–S batteries, can not only facilitate electron transfer and buffer the large volumetric change of sulfur benefiting from their porous structure and excellent flexibility, but also enable stronger physical/chemical adsorption capacity toward polysulfides (LiPSs) when doped with abundant heteroatoms to promote the sulfur redox kinetics and achieve the high sulfur loading. This review firstly introduces the properties of various CPs including structural CPs (polypyrrole (PPy), polyaniline (PANi), polyethylene dioxothiophene [PEDOT]) and compound CPs (polyethylene oxide (PEO), polyvinyl alcohol (PVA) and poly(acrylic acid) [PAA]), and their application potential in Li–S batteries. Furthermore, the research progress of various CPs in different components (cathode, separator, and interlayer) of Li–S batteries is systematically summarized. Finally, the application perspective of the CPs in Li–S batteries as a potential guidance is comprehensively discussed.

Chen, Xin↗

Unraveling the role of EGR olefins at advanced combustion conditions in the presence of nitric oxide: Ethylene, propene and isobutene

We report the role of EGR (exhaust gas recirculation) olefinic constituents at advanced combustion conditions in the presence of nitric oxide is unraveled in this study through experimental and modeling efforts using a twin-piston rapid compression machine operating at a stochiometric fuel loading with 20% EGR by mass, pressures of 20 and 40 bar, and temperatures from 680 to 950 K. Five different levels of olefin addition, focusing on ethylene, propene and isobutene, with a fixed amount of NO at 70 ppm are doped into test mixtures of PACE-20, a multi-component gasoline surrogate, where olefin addition effects are characterized through changes in ignition times and heat release rates. Experiments indicate that all three EGR olefins inhibit autoignition reactivity and low-temperature heat release at Tc < 850 K, with isobutene exhibiting the greatest impact, while at Tc > 850 K, low ethylene and propene additions promote reactivity. A recently updated chemical kinetic model, with detailed gasoline/NO x interacting and olefin/NO x interacting chemistry incorporated, is adopted to simulate the experiments. Simulation results are somewhat inconsistent with the experiments, where the model captures the inhibiting effects of all olefins on first-stage ignition reactivity, while consistently predicting a promoting effect on main ignition reactivity. Sensitivity and rate of production analyses reveal that adding olefins greatly alters the role of the consuming pathways for the olefins and their primary derivatives at the initial stage of the oxidation process, particularly with the presence of NO, where the olefins and their derivatives interact with both NO x species such as NO 2 and other species such as OH and HO 2 . The olefin/NO x interactions are particularly pronounced with propene and isobutene addition, where these lead to increased ignition reactivity by facilitating NO production and are mostly responsible for the disagreement between the model and experiments. Further investigations of olefin interacting chemistry, particularly those with NOx species, are needed for chemistry models to accurately predict the complicated effects of EGR.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extraction of Nitric Acid and Uranium with DEHiBA under High Loading Conditions

We report the mechanism by which high concentrations (1.5 M in n-dodecane) of N,N-di-2-ethylhexylisobutyramide (DEHiBA) extracts HNO 3 and UO 2 (NO 3 ) 2 is under examination. Most prior studies have examined the extractant and the mechanism at a concentration of 1.0 M in n-dodecane, however under the higher loading conditions that can be achieved by a higher concentration of extractant this mechanism could change. Increased extraction of both nitric acid and uranium is observed with an increased concentration of DEHiBA. The mechanisms are examined by thermodynamic modeling of distribution ratios, 15 N NMR, and FTIR spectroscopy coupled with Principal Component Analysis (PCA). Speciation diagrams produced through thermodynamic modeling have been qualitatively reproduced through PCA of the FTIR spectra. The predominant extracted species of HNO 3 (DEHiBA), HNO 3 (DEHiBA) 2 , and UO 2 (NO 3 ) 2 (DEHiBA) 2 are in good agreement with prior literature reports for 1.0 M DEHiBA systems. Evidence for an additional species of either UO 2 (NO 3 ) 2 (DEHiBA) or UO 2 (NO 3 ) 2 (DEHiBA) 2 (HNO 3 ) also contributing to the extraction of uranium species is given.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Estimated Hourly Electricity Demand Profiles for Each County in the Contiguous United States

In this data descriptor, we present hourly electricity demand estimates for each county in the contiguous United States from 2016 to 2023. The demand profiles represent the sum of two components for each county. The first is the weighted average of reported hourly demand profiles for North American Electric Reliability Corporation balancing authority (BA) regions and subregions, scaled to match annual estimates of county-level retail sales and direct use of electricity and weighted by the estimated percentage of county load served by each BA region or subregion. The second is the weighted average of modeled hourly, county- and sector-level distributed photovoltaic (DPV) capacity factor profiles, scaled to match annual estimates of on-site consumption of DPV-generated electricity for each county and weighted by the percentage of consumption attributable to each sector.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A High-Current Pulsed Prototype Power Supply

The Accelerator Controls Operations Research Network (ACORN) project aims to modernize the accelerator control system and replace aging power supplies at Fermilab. As part of this effort, outdated RF ferrite bias power supplies will be redesigned. These power supplies are essential for tuning the resonant frequency of RF cavities by delivering programmable current outputs of up to 2500 A and voltages ranging from −10 V to +35 V. They operate at a repetition rate of 15 Hz in the Booster ring, and 1 Hz at the Main Injector ring. The power supplies utilize a bank of transistors in the linear region, connected in parallel with the load, to actively regulate the output current from a 12-pulse SCR bridge. To support this upgrade, a new bias power supply topology was developed as proof of concept. The design utilizes an IGBT Hbridge operating in Pulse Width Modulation (PWM) mode, controlled by a microcontroller. A prototype, constructed using spare components, successfully delivered an output current of 500 A at a repetition rate of 15 Hz during initial testing. The circuit's bandwidth was measured at 480 Hz, highlighting opportunities for further optimization in the controller design to achieve the target bandwidth of 2 kHz.

Bullman, Austin [ORNL]↗

Concrete Thermal Energy Storage Enabling Flexible Operation without Coal Plant Cycling

The work described in this report is responsive to the Office of Fossil Energy program “Energy Storage for Fossil Power Generation.” The pilot plant built as a result of this project demonstrated the feasibility and performance of a concrete thermal energy storage (CTES) system integrated with a supercritical coal power plant. The 10 MWh electrical (>25 MWh thermal) CTES unit, developed by Storworks Power, was designed to enable flexible operation of coal plants without cycling damage. The project's key technical achievements showcase a significant advancement in energy storage technology. A modular CTES system using 42 “Bolderblocs” units was successfully designed and constructed at Alabama Power’s Plant Gaston Unit 5, with each block containing embedded stainless-steel coils in specialized, cost-effective high-temperature concrete. The system interfaced seamlessly with the plant's 3500 psig (241 barg), 1000°F (538°C) supercritical steam, demonstrating operational flexibility. Over 86 full cycles, the CTES exhibited rapid charging and discharging capabilities, effectively mimicking steam turbine feed conditions and handling varying load profiles and storage durations. Performance validation confirmed the system's ability to consistently meet design target steam conditions of 75 bar-a and ~400°C for nominal baseline discharge. The concrete material withstood repeated thermal cycling without degradation, validating earlier lab-scale tests. Integration of balance of plant components, including a condensate management system with storage tank and air-cooled condenser, minimized plant interfaces and water consumption. A robust control scheme ensured safe, automated operation across various scenarios. Key learnings from the project were invaluable: 1. Initial concrete drying and commissioning procedures were refined for future deployments, enhancing efficiency in subsequent installations. 2. System flexibility exceeded expectations, with rapid response to changing conditions. 3. Design improvements were identified including optimized insulation and piping that will enhance overall system efficiency in future deployments 4. Full cycle thermal roundtrip efficiencies exceeded 88%. While the roundtrip electrical efficiency was somewhat limited by known challenges using input steam, such constraints may be mitigated by swapping steam for hot air as thermal input. 5. A summary of key performance parameters for the pilot test and predicted performance of a full scale commercial system with specified improvements determined from the pilot are shown in Section 8. The project faced challenges, including COVID-19 delays and host plant availability constraints. However, these were overcome through adaptive planning and execution. The successful management of these obstacles demonstrated the resilience and adaptability of the project team and the robustness of the CTES technology. This successful pilot demonstrates the potential for CTES to enhance coal plant flexibility, supporting grid stability as renewable penetration increases. The validated design and operational data provide a solid foundation for scaling up to utility-scale implementations, potentially transforming how thermal plants operate in evolving energy landscapes. The system's ability to rapidly respond to changing grid conditions while maintaining high efficiency makes it a promising solution for balancing intermittent renewable energy sources. Furthermore, the project highlighted the potential for even greater efficiencies in future iterations. The use of air as an input medium could potentially eliminate the limitations observed with steam input, opening new possibilities for energy storage applications beyond coal plant integration. In conclusion, this pilot project not only achieved its primary goals but also uncovered additional benefits and potential applications of the CTES technology. It represents a significant step forward in addressing the challenges of grid stability and flexibility in an increasingly renewable-driven energy landscape.

01 COAL, LIGNITE, AND PEAT↗

Assessment of Survey Results from Advanced Reactor Industry Domain Experts on Nonlinear Soil-Structure Interaction Analysis Software Verification and Validation

The seismic load case has a significant impact on the design and cost of nuclear power plants. Given the need to substantially reduce cost, advanced reactor designers are looking to leverage numerical tools that enable seismic analysis of an integrated vessel/support/structure/soil system. Modern nonlinear analysis tools provide a solution, capturing dynamic coupling between components (including soil-structure interaction (SSI)) concurrent with nonlinear behavior in one or more parts of the system. Although these methods have a rich history of technical development and implementation, software quality assurance (SQA) following nuclear industry standards remains a significant burden for those wishing to adopt such methods for advanced reactor design and licensing. To reduce the SQA burden, this project will develop the guidance for SQA verification and validation (V&V) of coupled nonlinear SSI analysis tools, to include a test matrix of software features and test problems to support commercial grade dedication (CGD). The guidance is intended to be technology-neutral: supporting designers of all advanced reactors. To maximize the value of the project to reactor designers, the project team performed focused surveys of and interviews with advanced reactor designers. Additionally, the project surveyed members of the broader industry involved in reactor design and licensing. The aggregated industry feedback consists of written survey responses, live polling responses, focused interviews, and informal feedback provided after outreach presentations, collectively referred to as “survey results”. Herein, the survey results are reported, reviewed, and assessed to inform follow-on project activities. The survey results confirmed the familiarity of the industry with the coupled nonlinear SSI analysis. They also affirm the project need based upon the expressed intent to (1) incorporate nonlinear features and (2) pursue the coupled nonlinear SSI analysis to reduce seismic demands and construction costs. All reactor designers indicated their intent to incorporate two or more nonlinear features, and all reactor designer respondents opined that the coupled nonlinear SSI analysis would allow for the optimization of the reactor design and construction. However, the programmatic challenges, whether real or perceived, present a significant barrier to reactor designers. The barrier most commonly identified by the reactor designer population was regulatory risk, with 70% citing this as a reason not to pursue the approach. The perceived regulatory risk identified by the reactor designers underscores the importance of regulator engagement and dialogue in this project. Additionally, half of the reactor designers identified cost and lack of guidance as a deterrent. The survey results also provide insights to tailor specific aspects of the guidance document and test matrix. The project plans to prepare both a formal referenceable guidance document and a collaborative, web-based test matrix and problem set. The project will focus on more complete test problem definitions for the prioritized nonlinear features over shallower problem descriptions for a larger set of features. The nonlinearities prioritized as high based upon survey feedback include fluid-structure interaction and seismic isolation and energy dissipation devices. The nonlinearities prioritized as intermediate include nonlinear geomaterials, nonlinear concrete, nonlinear steel, and interface/contact nonlinearity. Deep embedment and the associated nonlinear phenomena are assigned the lowest priority based upon survey feedback.

42 ENGINEERING↗

Numerical Investigation of Two-Stage Vapor Compression System with Simultaneous Vapor and Liquid Injection

Two-stage vapor compression systems can be advantageous over single-stage systems by providing improved system performance, lower discharge temperature and reduced throttling losses. These systems employ various intermediate configurations, such as liquid injection and vapor injection. This paper presents a configuration for a R1234ze(E) two-stage air-conditioning system using a turbo compressor with two injection ports, one for vapor injection and the second for liquid injection. The liquid injection is used to cool the motor and electronics. A component-based representation and solution approach was used to simulate the two-stage compression system with simultaneous vapor and liquid injection at steady state. The turbo compressor was represented using a customized performance map. The condenser and the evaporator were modeled using finite-volume approach. A parametric study was conducted to assess the impact of the following three variables on the system performance: vapor injection ratio, condenser air flow rate, and discharge pipe pressure drop. The simulation results show that as the vapor injection ratio increased, the system performance undergoes a tradeoff between an enhanced subcooling effect (and thus enhanced unit refrigeration capacity) and a decreased suction mass flow rate. Maximum COP occurs when the vapor injection ratio was 0.1. The results also show that as the condenser air flow rate increased, both the capacity and power consumption (including fan power) increased monotonically, and COP increased first and then decreased. At 75% load, the COP improvement at the optimum flow rate was marginally less than 0.5%. Lastly, higher discharge pipe pressure drop increased the discharge pressure. It showed very small effect on the overall system performance at the condition selected for the current study.

component-based steady-state simulation↗