Tuning the Functionalities of Porous Liquids for Emergent Gas-Capture Properties

Type 3 Porous Liquids (PLs) are a class of materials with the potential to revolutionize gas capture, storage, and utilization. These PLs are formed by suspending sorbent nanoparticles (e.g., metal−organic frameworks) in sterically excluded solvents, creating permanent porosity for gas capture in a processable, low-viscosity phase. Herein, a computational study revealed sorbent surface functionalization strategies to enhance CO 2 sorption, and the molecular structural signatures underpinning the enhancements in gas uptake. PLs composed of a ZIF-8 surface functionalized with 3-amino-1,2,4-triazole (Atz) in glyceryl triacetate were targeted for emergent CO 2 capture, exceeding that of the unfunctionalized ZIF-8 PL. ZIF-8 was surface functionalized with Atz at various surface coverage fractions (f), and classical molecular dynamics simulations predicted an increase in CO 2 sorption capacity with increasing f, up to f = 0.75. Additionally, detailed structural analyses revealed that solvent orientational order, derived from the solvent triplet-angle distribution, can identify the gas-capture potential of a PL without requiring computationally expensive direct modeling of the CO 2 sorption. Combined with experimental validation, initial computational screening of PL compositions promises to accelerate the discovery of PL compositions for novel gas separation materials platforms.

gas capture↗

Parametric Testing and Evaluation of a Novel Biphasic Absorption Process for Post-Combustion Carbon Capture

A novel biphasic CO2 absorption process (BiCAP) is being developed at the University of Illinois. BiCAP is enabled by using a new class of biphasic solvents developed based on multi-property criteria for postcombustion carbon capture. The process was previously demonstrated at the lab-scale, including in 10 kWe absorption and desorption column systems. In the current study, the process has been scaled up by building and testing a 40 kWe integrated capture skid at a power plant. Parametric tests for two biphasic solvents were conducted with the synthetic flue gas made of bottle CO2 gas and air to validate the performance and operational flexibility of the unit with respect to varying process or operating conditions. Operation of the phase separator, which is unique equipment to BiCAP, was verified to be stable and efficient. Two liquid phases could be separated via static settlement based on a density difference and >90% of the CO2 absorbed was concentrated in the separated CO2-rich phase. Results of parametric tests showed that the minimum heat duty appeared at the optimal stripping pressure. A higher stripping temperature was more favourable to improve overall energy performance. Introducing a secondary cold solvent feed stream to the top of the stripper via bypassing the cross heat exchanger helped reduce the heat loss carried with water vapour. Test results also revealed that the heat duty requirement was comparable when the CO2 concentration in flue gas decreased from ~11 to 4 vol.% as the phase separation decoupled the absorption and desorption steps in BiCAP. Under typical steady-state conditions, both biphasic solvents lowered the process heat duty by >40% compared with the reference 30 wt.% monoethanolamine solvent.

Absorption↗

Elucidating the Interfacial Barriers in Lanthanide Back-Extraction: From Water to Oil and Back Again

Recovery of critical rare earth elements from complex mixtures has long been realized via solvent extraction, where ions in an aqueous phase are separated into an organic phase using amphiphilic ligands. While a great deal of effort has been placed on understanding this forward reaction, substantial knowledge gaps in the back-extraction process remain. This includes the mechanism of interfacial dissociation and transport back into a highly acidic aqueous phase for further processing. In this work, we connect back-extraction kinetics made in realistic solvent extraction systems to salient interfacial chemistry and structure that represent bottlenecks in the back-extraction of lanthanide ions. We show that the interface between the two liquid phases varies dramatically based on the composition of both phases. Water stretching signals are shown to report on the population of lingering interfacial complexes and are thus used as a reporter of competitive adsorption from excess free ligands in solution for limited interfacial vacancies. We show that excess free ligands, often used to improve forward extractions, set up interfacial blockades inhibiting back-extraction both kinetically and thermodynamically. In conclusion, this insight opens up avenues to tune interfacial properties to facilitate a more dynamic, exchangeable interface to speed up back-extractions while using less energy intensive chemical swings.

Interfaces↗

Water as a matrix for life

Life is based on non-covalent interactions. They might be either specific (enzyme-substrate interactions, selective ion transport) or nonspecific (lipid-lipid and lipid-protein interactions needed for membrane integrity, fusion and division). Their strength needs to be properly tuned, and this is mediated by the solvent. If interactions are too weak, there might be undesired response to natural fluctuations of physical and chemical parameters. If they are too strong it could impede kinetics and energetics of cellular processes. Thus, the solvent must allow for balancing these interactions. Physical and chemical properties of solvent provide strong constraints for life. Water exhibits a remarkable trait that it promotes both solvophobic and solvophilic interactions. Solvophobic interactions; related to high dielectric constant of the solvent) are necessary for self-organization of matter whereas solvophilic interactions are needed to ensure solubility of polar species. Water offers a large temperature domain of stable liquid and the characteristics hydrophobic effects are a consequence of the temperature in sensitivity of essential properties of its liquid state. Water, however, is not the only liquid with these favorable properties. I will compare in detail properties of water and other pure liquids or their mixtures that have a high dielectric constant and simultaneously support self-organization. I will also discuss properties of water that are unfavorable to life (e.g. its chemical activity against polymerization reactions) and close with summarizing what are alternatives to water as a matrix of life in space.

Pohorille, Andrew↗

Online Alpha Monitoring of High Cs-137 Hanford and SRS High Level Waste with Tensioned Metastable Fluid Detectors

The Department of Energy’s Hanford and Savannah River Sites maintain millions of gallons of caustic supernate and salt high activity waste in their high-level waste (HLW) tank farm inventories. The Savannah River Site is currently treating this waste with a calixarene-based solvent extraction of Cs-137 to reduce these inventories. Hanford is employing an at-tank crystalline silico titanate (CST) based solid phase extraction methodology to reduce their liquid HLW inventories. Due to the high solubility of Cs-137 and the relative insolubility of the actinides in these caustic waste forms, the beta to alpha radioactivity ratio can often exceed six orders of magnitude in the feed solutions to these treatment processes. This unique characteristic leads to significant technical challenges in making rapid gross alpha measurements in the presence of the overwhelming beta, gamma, as well as dissolved sodium salt in these HLW matrices. Conventional radioanalytical techniques, such as liquid scintillation analysis or gas flow proportional counting require significant radiochemistry preparation prior to the radiometric measurements for gross alpha activity. These required pretreatments render these technologies untenable for rapid quantification of gross alpha activity that could be required to support on or at-line measurements ensuring a waste stream will meet regulatory requirements. The radiation measurement properties of Tensioned Metastable Fluid Detectors (TMFDs) have been studied by Purdue University’s Taleyarkhan research group for well over a decade. Fluids tensioned to the appropriate degree will rupture when struck by radiation, resulting in a measurable cavitation event. The negative pressure generating this tension can be adjusted by centrifugal rotation or by acoustic means in such a way that these cavitation events can be generated from alpha radiation but will not be generated by beta or gamma radiation. Purdue University and the Savannah River National Laboratory are currently collaborating to develop a gamma/beta blind, spectroscopic alpha measurement system based on the Tensioned Metastable Fluid Detector technology to provide a potential solution for performing rapid gross alpha measurements on these high gamma/beta sample matrices. Measurements using the Indirect Drive Acoustically Tensioned Metastable Fluid Detectors developed as part of this collaboration were performed with an alpha emitting radionuclide. Successful determination of gross alpha activity was observed, indicating a potential pathway for rapid gross alpha measurements in remote-handled shielded cells or in process situations requiring online alpha monitoring. Measurements using this system have been conducted on high beta activity solutions, demonstrating the beta blind capability of this system. Measurements are currently underway to test the system’s capability to measure gross alpha activity on Savannah River Site high level waste high Cs-137 samples that have been measured by the SRNL radiochemistry team. This work was supported by the DOE EM Technology Development program.

DiPrete, David [Savannah River National Laboratory↗

Lithium-sulfur battery with lithium polysulfide catholyte

A liquid catholyte for a Li-S battery comprises a non-aqueous solution of at least one lithium polysulfide of formula Li 2 S x (wherein x is selected from 4, 6, and 8) and an anion receptor compound capable of complexing with polysulfide anion. The non-aqueous solution typically is composed of the Li 2 S x and the anion receptor compound dissolved in a non-aqueous solvent (e.g., one or more organic ether or fluorinated ether solvents). The anion receptor compound typically is present in the catholyte at a concentration of about 0.1 M to about 4 M. Li-S batteries comprise a metallic lithium anode; a porous conductive substrate; a separator membrane between the anode and the porous conductive substrate; and the liquid catholyte composition within pores of the substrate.

25 ENERGY STORAGE↗

Effects of the advanced organosolv pretreatment strategies on structural properties of woody biomass

Plants have evolved their lignocellulosic cell walls through complex structural and chemical mechanisms to protect itself against microbial attacks, which makes native lignocellulosic biomass recalcitrant to enzymatic deconstruction. Pretreatment is a crucial step in the biological conversion of biomass as it can render structural changes in the plant cell wall to reduce the biomass recalcitrance, thus enhancing its sugar release performance. There have been many efforts to develop effective pretreatment technologies to overcome the biomass recalcitrance with a primary focus on the efficient conversion of biomass carbohydrates to liquid fuels, while lignin is significantly underutilized despite its bulk amount and high-value opportunities. In this study, the effects of two recent organosolv pretreatment strategies, co-solvent enhanced lignocellulosic fractionation (CELF) and γ-Valerolactone (GVL) pretreatments, on physicochemical properties of poplar were investigated and compared with the effects of conventional ethanol organosolv pretreatment. Diverse physicochemical properties of biomass including chemical compositions, molecular weights of cellulose and lignin, aromatics and inter-unit linkages of lignin, lignin hydroxyl group contents, cellulose crystallinity, and accessible surface area of cellulose were analyzed before and after pretreatments. The results revealed how each organic solvent pretreatment system affected biomass structural characteristics and recalcitrance.

Meng, Xianzhi↗

Selective permeation up a chemical potential gradient to enable an unusual solvent purification modality

The need for energy-efficient recovery of organic solutes from aqueous streams is becoming more urgent as chemical manufacturing transitions toward nonconventional and bio-based feedstocks and processes. In addition to this, many aqueous waste streams contain recalcitrant organic contaminants, such as pharmaceuticals, industrial solvents, and personal care products, that must be removed prior to reuse. We observe that rigid carbon membrane materials can remove and concentrate organic contaminants via an unusual liquid-phase membrane permeation modality. Surprisingly, detailed thermodynamic calculations on the chemical potential of the organic contaminant reveal that the organic species has a higher chemical potential on the permeate side of the membrane than on the feed side of the membrane. This unusual observation challenges conventional membrane transport theory that posits that all permeating species move from high chemical potential states to lower chemical potential states. Based on experimental measurements, we hypothesize that the organic is concentrated in the membrane relative to water via favorable binding interactions between the organic and the carbon membrane. The concentrated organic is then swept through the membrane via the bulk flow of water in a modality known as “sorp-vection.” We highlight via simplified nonequilibrium thermodynamic models that this “uphill” chemical potential permeation of the organic does not result in second-law violations and can be deduced via measurements of the organic and water sorption and diffusion rates into the carbon membrane. Moreover, this work identifies the need to consider such nonidealities when incorporating unique, rigid materials for the separations of aqueous waste streams.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phenomenology of Intermediate Molecular Dynamics at Metal-Oxide Interfaces

Reaction intermediates buried within a solid-liquid interface are difficult targets for physiochemical measurements. They are inherently molecular and locally dynamic, while their surroundings are extended by a periodic lattice on one side and the solvent dielectric on the other. Challenges compound on a metal-oxide surface of varied sites and especially so at its aqueous interface of many prominent reactions. Recently, phenomenological theory coupled with optical spectroscopy has become a more prominent tool for isolating the intermediates and their molecular dynamics. The following article reviews three examples of the SrTiO3-aqueous interface subject to the oxygen evolution from water: reaction-dependent component analyses of time-resolved intermediates, a Fano resonance of a mode at the metal-oxide–water interface, and reaction isotherms of metastable intermediates. The phenomenology uses parameters to encase what is unknown at a microscopic level to then circumscribe the clear and macroscopically tuned trends seen in the spectroscopic data.

Chemistry↗

Rescue of Unique Liquid IP-2 Portable Tanks at Savannah River Site

Introduction • Savanah River Site procured six large IP-2 portable tanks capable of transporting liquids in 2003 to support layup of F Canyon at SRS. • Tanks are being rescued and recertified to support eventual disposition of up to 171,000 L of contaminated solvent solutions from H Canyon at SRS and to potentially transport Depleted Uranium solutions to support the ABD Program.

Fee, Nathaniel C. [Savannah River Nuclear Solution↗

Environmentally Compatible Vapor-Phase Corrosion Inhibitor for Space Shuttle Hardware

USA-SRB Element is responsible for the assembly and refurbishment of the non-motor components of the SRB as part of Space Shuttle. Thrust Vector Control (TVC) frames structurally support components of the TVC system located in the aft skirt of the SRB. TVC frames are exposed to the seacoast environment after refurbishment and, also, to seawater immersion after splashdown, and during tow-back to CCAFS-Hangar AF refurbishment facilities. During refurbishment operations it was found that numerous TVC frames were experiencing internal corrosion and coating failures, both from salt air and seawater intrusions. Inspectors using borescopes would visually examine the internal cavities of the complicated aluminum alloy welded tubular structure. It was very difficult for inspectors to examine cavity corners and tubing intersections and particularly, to determine the extent of the corrosion and coating anomalies. Physical access to TVC frame internal cavities for corrosion removal and coating repair was virtually impossible, and an improved method using a Liquid (water based) Vapor-phase Corrosion Inhibitor (LVCI) for preventing initiation of new corrosion, and mitigating and/or stopping existing corrosion growth was recommended in lieu of hazardous paint solvents and high VOC/solvent based corrosion inhibitors. In addition, the borescopic inspection method used to detect corrosion, and/or coating anomalies had severe limitations because of part geometry, and an improved non-destructive inspection (NDI) method using Neutron Radiography (N-Ray) was also recommended.

Novak, Howard L.↗

Environmentally Compatible Vapor-Phase Corrosion Inhibitor for Space Shuttle Hardware

USA-SRB Element is responsible for the assembly and refurbishment of the non-motor components of the SRB as part of Space Shuttle. Thrust Vector Control (TVC) frames structurally support components of the TVC system located in the aft skirt of the SRB (Solid Rocket Booster). TVC frames are exposed to the seacoast environment after refurbishment and, also, to seawater immersion after splashdown, and during tow-back to CCAFS-Hangar AF refurbishment facilities. During refurbishment operations it was found that numerous TVC frames were experiencing internal corrosion and coating failures, both from salt air and seawater intrusions. Inspectors using borescopes would visually examine the internal cavities of the complicated aluminum alloy welded tubular structure. It was very difficult for inspectors to examine cavity corners and tubing intersections and particularly. to determine the extent of the corrosion and coating anomalies. Physical access to TVC frame internal cavities for corrosion removal and coating repair was virtually impossible, and an improved method using a Liquid (water based) Vapor-phase Corrosion Inhibitor (LVCI) for preventing initiation of new corrosion, and mitigating and/or stopping existing corrosion growth was recommended in lieu of hazardous paint solvents and high VOC/solvent based corrosion inhibitors. In addition, the borescopic inspection method used to detect corrosion, and/or coating anomalies had severe limitations because of part geometry, and an improved non-destructive inspection (NDI) method using Neutron Radiography (N-Ray) was also recommended.

Novak, Howard L.↗

Environmentally Compatible Vapor-Phase Corrosion Inhibitor for Space Shuttle Hardware

USA-SRB Element is responsible for the assembly and refurbishment of the non-motor components of the SRB as part of Space Shuttle. Thrust Vector Control (TVC) frames structurally support components of the TVC system located in the aft skirt of the SRB. TVC frames are exposed to the seacoast environment after refurbishment and, also, to seawater immersion after splashdown, and during tow-back to CCAFS-Hangar AF refurbishment facilities. During refurbishment operations it was found that numerous TVC frames were experiencing internal corrosion and coating failures, both from salt air and seawater intrusions. Inspectors using borescopes would visually examine the internal cavities of the complicated aluminum alloy welded tubular structure. It was very difficult for inspectors to examine cavity corners and tubing intersections and particularly, to determine the extent of the corrosion and coating anomalies. Physical access to TVC frame internal cavities for corrosion removal and coating repair was virtually impossible, and an improved method using a Liquid (water based) Vapor-phase Corrosion Inhibitor (LVCI) for preventing initiation of new corrosion, and mitigating and/or stopping existing corrosion growth was recommended in lieu of hazardous paint solvents and high VOC / solvent based corrosion inhibitors. In addition, the borescopic inspection method used to detect corrosion, and/or coating anomalies had severe limitations because of part geometry, and an improved non-destructive inspection (NDI) method using Neutron Radiography (N-Ray) was also recommended.

Novak, Howard L.↗

Evaluation of New Additions to OLI Software in Predicting Mercuric and Mercurous Species in Liquid Waste Operations

Speciation of mercury during the pretreatment steps of tank waste processing is critical to successful mercury removal prior to vitrification during Liquid Waste Operations (LWO) at SRS. OLI software has been used to predict mercury speciation and activity throughout LWO. The OLI software operates based on a thermodynamic framework called the Mixed Solvent Electrolyte (MSE) framework. The MSE framework allows prediction in theoretically infinitely dilute to concentrated mixtures (e.g., purely solute solutions). Before modification to the MSE framework databanks, certain critical mercury species were missing in the MSE databank, and some thermodynamic data needed to be updated for the OLI software to accurately predict mercury chemical species in SRS waste tanks. To better reflect streams across LWO, new mercury species were integrated into the MSE database. To evaluate the changes to the OLI MSE framework per the Technical Task Request (TTR) and the Task Technical and Quality Assurance Plan (TTQAP), waste stream compositions from Tanks 38, 43, and Tank 50 decontaminated salt solution (DSS) were used as model inputs. Models were developed and executed using both the old and new databases. Compositional analyses from caustic Tank 50 DSS and caustic Tanks 38 and 43 were used as the input streams. These streams represent the most comprehensive chemical data sets where both mercury and tank constituents were measured together. Results for Tank 50 DSS predict HgO as the predominant species in both databases. Both methyl and dimethyl Hg species are present when the new database is ‘on’ and are not predicted with the new database turned ‘off’. The new database predicts a greater amount of HgO and a greater fraction of it in the solid phase. Pourbaix diagrams (potential vs. pH) generated for each Tank 50 DSS were identical regardless of which database was used. Elemental Hg and HgO were predicted in the water stable region under basic conditions. Tanks 38 and 43 follow similar trends as the Tank 50 DSS models. Unlike Tanks 38 and 50 DSS, the Tank 43 Pourbaix plot shows a region of stability for an aqueous HgOHCO3 - species between approximately pH 7-11. In all streams, when MeHg+ is included in the inputs, the new database predicts aqueous MeHgOH as the dominant species. If elemental or dimethyl mercury is in the waste stream, the new database model predicts they are unchanged and remain in those states and quantities. Additionally, the total mercury values are reported for both the measured input data and the OLI output data for all considered tanks. The summary indicates that the percentage error between the measured and calculated values is less than 1% in all cases The reconciliations and generation of the Pourbaix diagrams for Tank 50 DSS took approximately ten times longer with the new database ‘on’. In addition, over the course of that time, models with the new database ‘on’ were more likely to crash or display an error. Some modest performance improvements were noted when modeling with an i7 processor versus an i5. An example error is found in Appendix A. Furthermore, Appendix B provides V&V for two chemical systems analyzed with the OLI software, results were satisfactory. It is recommended to utilize the new databases (i.e., HCO.ddb and SR-Hg.ddb) in future Savannah River Mission Completion applications of OLI to represent pseudo steady-state. Furthermore, the integration and utilization of the new databases (i.e., HCO.ddb and SR-Hg.ddb) in modeling applications (e.g., Aspen) is also recommended.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Understanding Solvation Behavior of the Saturated Electrolytes with Small/Wide-Angle X-ray Scattering and Raman Spectroscopy

Concentrated electrolytes are attracting significant attention because the solvation structures could stabilize the interface, encouraging novel electrolyte development for high-voltage and long-cycle-life batteries. Saturated electrolytes, which have the highest salt concentrations, have been rarely studied because of their shortcomings of high viscosity and low ionic conductivity. Nevertheless, the exciting solvation structure in saturated solution is still worth studying, significantly broadening the comprehensive understanding of the solvation processes. In this work, we investigate the saturated lithium bis(trifluoromethanesulfonyl)imide (LiTFSI) dissolved in seven different organic solvents, including propylene carbonate (PC), tetrahydrofuran (THF), acetonitrile (ACN), dimethylformamide (DMF), 1,2-dimethoxyethane (DME), diethylene glycol dimethyl ether (Diglyme), and tetraethylene glycol dimethyl ether (Tetraglyme). The combined small/wide-angle X-ray scattering and Raman spectroscopy are employed to study the global and local solvation structure. Here, this work demonstrates a method for detecting the structure of liquids, which will facilitate the study of structure–performance relationships and the screening of new electrolytes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Peak‐in‐Valley Metal Nano‐Architectures via E‐Beam‐Guided Metal Oxide Redox

Focused electron beams enable nanoscale material modification via localized etching or deposition. In liquid-phase electron-beam-mediated processing, radiolysis-driven redox reactions present an opportunity to control both etching and deposition simultaneously. Here, this duality using a water-ammonia solvent as a tunable redox mediator on copper surfaces is demonstrated. At lower ammonia concentrations, the oxidation process dominates, etching copper to sub-50-nm depths. The copper ions and ion-complexes released during this initial oxidation step are reduced by solvated electrons resulting in metal deposition into the etched sites, over longer e-beam exposures, producing characteristic peak-in-valley nanostructures. Conversely, at higher ammonia concentrations copper-ammine ion complexation and radiolytic oxidizing species scavenging by ammonia occur at higher rates, creating a reducing environment conducive to rapid beam-guided copper deposition. Reaction-transport simulations and experiments are performed to show the effects of ammonia-mediated radiolysis chemistry, describing the direct influence of solvent concentration on redox balance and the outcome of e-beam guided processing. By uniting both etching and deposition within a single framework, this work provides a versatile route for controlled surface nanostructuring.

copper nanostructures↗

Assessing Melting and Solid–Solid Transition Properties of Choline Chloride via Molecular Dynamics Simulations

Choline chloride (ChCl) is used extensively as a hydrogen bond donor in deep eutectic solvents (DESs). However, determining its melting properties experimentally is challenging due to decomposition upon melting, leading to widely varying literature values. Accurate melting properties are crucial for understanding the solid–liquid phase behavior of ChCl-containing DESs. Here, we employ molecular dynamics simulations to compute the phase transitions of ChCl, testing a variety of atomistic force fields. We find that the results are sensitive to the choice of force field, but a melting temperature of 627 K and a melting enthalpy of 7.8 kJ/mol seem most reasonable, in good agreement with some literature values. Furthermore, we suggest these as the likely melting properties of ChCl, though the results are tentative due to limited experimental data for the liquid ChCl phase.