Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high - contrast imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Score-based deterministic density sampling

We propose a deterministic sampling framework using Score-Based Transport Modeling for sampling an unnormalized target density π given only its score ∇ log π. Our method approximates the Wasserstein gradient flow on KL($f_t$∥π) by learning the time-varying score ∇ log $f_t$ on the fly using score matching. While having the same marginal distribution as Langevin dynamics, our method produces smooth deterministic trajectories, resulting in monotone noise-free convergence. We prove that our method dissipates relative entropy at the same rate as the exact gradient flow, provided sufficient training. Numerical experiments validate our theoretical findings: our method converges at the optimal rate, has smooth trajectories, and is often more sample efficient than its stochastic counterpart. Experiments on high-dimensional image data show that our method produces high-quality generations in as few as 15 steps and exhibits natural exploratory behavior. The memory and runtime scale linearly in the sample size.

97 MATHEMATICS AND COMPUTING↗

A statistical analysis of data extraction for land cover information from high-altitude and satellite images

Land cover information from a 10 by 30 km test site in eastern Wisconsin extracted using 70 mm positive LANDSAT transparencies in an additive color viewer at a scale of 1:500,000 was compared with land cover information extracted using LANDSAT 9 x 9 inch positive transparencies at a scale of 1:1,000,000. Color infrared photography (NASA RB-57) at a scale of 1:60,000 provided ground truth for each land cover type. Interpretations were made for four land cover classes: 1) forest-brushland; (2) structures-barren land; (3) surface water; and (4) agricultural-open land. Statistical comparisons showed that neither method for the extraction of this data was clearly superior.

Kiefer, R. W.↗

Upgrading and testing program for narrow band high resolution planetary IR imaging spectrometer

An imaging spectrometer, intended primarily for observations of the outer planets, which utilizes an acoustically tuned optical filter (ATOF) and a charge coupled device (CCD) television camera was modified to improve spatial resolution and sensitivity. The upgraded instrument was a spatial resolving power of approximately 1 arc second, as defined by an f/7 beam at the CCD position and it has this resolution over the 50 arc second field of view. Less vignetting occurs and sensitivity is four times greater. The spectral resolution of 15 A over the wavelength interval 6500 A - 11,000 A is unchanged. Mechanical utility has been increased by the use of a honeycomb optical table, mechanically rigid yet adjustable optical component mounts, and a camera focus translation stage. The upgraded instrument was used to observe Venus and Saturn.

Wattson, R. B.↗

OAST Space Theme Workshop. Volume 3: Working group summary. 2: Data handling, communications (E-2). A. Statement. B. Technology needs (form 1). C. Priority assessment (form 2)

Technologies required to support the stated OAST thrust to increase information return by X1000, while reducing costs by a factor of 10 are identified. The most significant driver is the need for an overall end-to-end data system management technology. Maximum use of LSI component technology and trade-offs between hardware and software are manifest in most all considerations of technology needs. By far, the greatest need for data handling technology was identified for the space Exploration and Global Services themes. Major advances are needed in NASA's ability to provide cost effective mass reduction of space data, and automated assessment of earth looking imagery, with a concomitant reduction in cost per useful bit. A combined approach embodying end-to-end system analysis, with onboard data set selection, onboard data processing, highly parallel image processing (both ground and space), low cost, high capacity memories, and low cost user data distribution systems would be necessary.

Source record↗

Application of abstract harmonic analysis to the high-speed recognition of images

Methods are constructed for rapidly computing correlation functions using the theory of abstract harmonic analysis. The theory developed includes as a particular case the familiar Fourier transform method for a correlation function which makes it possible to find images which are independent of their translation in the plane. Two examples of the application of the general theory described are the search for images, independent of their rotation and scale, and the search for images which are independent of their translations and rotations in the plane.

Usikov, D. A.↗

High spatial resolution infrared imaging of L1551-IRS 5 - Direct observations of its circumstellar envelope

Images of L1551-IRS 5 were obtained at 1.65, 2.2, and 3.8 microns using the University of Rochester's Infrared Array Camera. It is found that IRS 5 is spatially resolved, and that it is elongated: the observed FWHM size of IRS 5 is 4.1 x 2.8 arcsec-squared at 2.2 microns. These observations are interpreted in terms of a flattened circumstellar envelope that is viewed from about 18 deg above its equatorial plane, a configuration that has been treated theoretically by Lefevre et al. In this model the central star is not seen directly, but only light scattered toward the observer from the visible polar region, where the envelope is thinnest, is observed. It is deduced that the envelope has a diameter of 1000 AU, a molecular hydrogen density of greater than or approximately equal to 4 x 10 to the 6th/cu cm, and a mass of greater than or approximately equal to 0.02 M solar mass, which results in an extinction of Av greater than about 33 mag to the central source.

Moneti, Andrea↗

Eos visible imagers

Some of the proposed Earth Observing System (Eos) optical imagers are examined. These imagers include: moderate resolution imaging spectrometer (MODIS); geoscience laser ranging system (GLRS); high resolution imaging spectrometer (HIRIS); the intermediate thermal infrared spectrometer (ITIR); multi-angle imaging spectrometer (MISR); earth observing scanning polarimeter (EOSP); and the lightening imaging sensor (LIS).

Barnes, W. L.↗

High-resolution detectors for imaging and spectroscopy at ultraviolet and soft X-ray wavelengths

The Multi-Anode Microchannel Arrays (MAMAs) are a family of pulse-counting imaging array detectors designed specifically for astrophysical investigations in space. The MAMAs have a number of unique performance characteristics which make them particularly suitable for imaging and spectroscopy at ultraviolet and soft X-ray wavelengths. First, they employ 'solar blind' photocathodes eliminating the 'red leak' problem associated with solid state arrays such as the CCDs. Second, they operate with zero readout noise, yielding photon-statistics limited signals. Third, they utilize a random readout technique and can determine both the location of a detected photon and also its arrival time to an accuracy of the order of 100 ns. This paper gives an overview of the construction, mode of operation, and performance characteristics of the MAMA detectors and describes the current status of the development program.

Timothy, J. G.↗

High time-resolution imaging with the MAMA detector systems

Current uses of the MAMA detector which utilize the photon time-tagging capabilities of these detectors are reported. These applications currently include image stabilization by means of post-processing corrections of platform drift and speckle interferometry. The initial results of a sounding rocket experiment to obtain UV images of NGC 6240 and results from speckle interferometry of Neptune's moon Triton are presented.

Morgan, Jeffrey S.↗

Development of a high resolution liquid xenon imaging chamber for gamma-ray astronomy

The objective was to develop the technology of liquid xenon (LXe) detectors for spectroscopy and imaging of gamma rays from astrophysical sources emitting in the low to medium energy regime. In particular, the technical challenges and the physical processes relevant to the realization of the LXe detector operated as a Time Projection Chamber (TPC) were addressed and studied. Experimental results were obtained on the following topics: (1) long distance drift of free electrons in LXe (purity); (2) scintillation light yield for electrons and alphas in LXe (triggering); and (3) ionization yield for electrons and gamma rays in LXe (energy resolution). The major results from the investigations are summarized.

Aprile, Elena↗

Development of a High Resolution Liquid Xenon Imaging Telescope for Medium Energy Gamma Ray Astrophysics

In the third year of the research project, we have (1) tested a 3.5 liter prototype of the Liquid Xenon Time Projection Chamber, (2) used a prototype having a 4.4 cm drift gap to study the charge and energy resolution response of the 3.5 liter chamber, (3) obtained an energy resolution as good as that previously measured by us using chambers with drift gaps of the order of millimeters, (4) observed the induction signals produced by MeV gamma rays, (4) used the 20 hybrid charge sensitive preamplifiers for a nondestructive readout of the electron image on the induction wires, (5) performed extensive Monte Carlo simulations to obtain results on efficiency, background rejection capability, and source flux sensitivity, and (6) developed a reconstruction algorithm for events with multiple interaction points.

Aprile, Elena↗

A High Resolution Liquid Xenon Imaging Telescope for 0.3-10 MeV Gamma Ray Astrophysics: Construction and Initial Balloon Flights

The results achieved with a 3.5 liter liquid xenon time projection chamber (LXe-TPC) prototype during the first year include: the efficiency of detecting the primary scintillation light for event triggering has been measured to be higher than 85%; the charge response has been measured to be stable to within 0.1% for a period of time of about 30 hours; the electron lifetime has been measured to be in excess of 1.3 ms; the energy resolution has been measured to be consistent with previous results obtained with small volume chambers; X-Y gamma ray imaging has been demonstrated with a nondestructive orthogonal wires readout; Monte Carlo simulation results on detection efficiency, expected background count rate at balloon altitude, background reduction algorithms, telescope response to point-like and diffuse sources, and polarization sensitivity calculations; and work on a 10 liter LXe-TPC prototype and gas purification/recovery system.

Aprile, Elena↗

A high resolution liquid xenon imaging telescope for 0.3-10 MeV gamma-ray astrophysics: Construction and initial balloon flights

An instrument is described which will provide a direct image of gamma-ray line or continuum sources in the energy range 300 keV to 10 MeV. The use of this instrument to study the celestial distribution of the (exp 26)Al isotope by observing the 1.809 MeV deexcitation gamma-ray line is illustrated. The source location accuracy is 2' or better. The imaging telescope is a liquid xenon time projection chamber coupled with a coded aperture mask (LXe-CAT). This instrument will confirm and extend the COMPTEL observations from the Compton Gamma-Ray Observatory (CGRO) with an improved capability for identifying the actual Galactic source or sources of (exp 26)Al, which are currently not known with certainty. sources currently under consideration include red giants on the asymptotic giant branch (AGB), novae, Type 1b or Type 2 supernovae, Wolf-Rayet stars and cosmic-rays interacting in molecular clouds. The instrument could also identify a local source of the celestial 1.809 MeV gamma-ray line, such as a recent nearby supernova.

Aprile, Elena↗

High Resolution Multimode Fiber Image Recovery

The research emphasis is on developing a cost-effective method of recovering image information from small, closely confined spaces using multimode fibers. The state-of-the-art good quality-viewing fiber, which can currently be used for performing this function, is a 0.5 mm diameter bundle containing 6000 pixels at a cost of $10,000 per fiber bundle. However, these fiber bundles are very fragile and can easily break during surgical use, thereby making instrument reliability and replacement cost,a major impediment to their routine use in many applications. The advantage of working with a single multimode fiber is that it is significantly less expensive and mechanically more robust. In addition, careful choice of numerical aperture allows a higher image resolution (roughly 750,000 pixels) with a 0.5 mm diameter multimode fiber.

Jackson, Deborah↗

Imaging Carbon Nanotubes in High Performance Polymer Composites via Magnetic Force Microscope

Application of carbon nanotubes as reinforcement in structural composites is dependent on the efficient dispersion of the nanotubes in a high performance polymer matrix. The characterization of such dispersion is limited by the lack of available tools to visualize the quality of the matrix/carbon nanotube interaction. The work reported herein demonstrates the use of magnetic force microscopy (MFM) as a promising technique for characterizing the dispersion of nanotubes in a high performance polymer matrix.

Lillehei, Peter T.↗