Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hierarchy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

745 records · Page 42

Precise interpretations of traditional fine-tuning measures

We uncover two precise interpretations of traditional electroweak fine-tuning (FT) measures that were historically missed. (i) a statistical interpretation : the traditional FT measure shows the change in plausibility of a model in which a parameter was exchanged for the 𝑍 boson mass relative to an untuned model in light of the 𝑍 boson mass measurement. (ii) an information-theoretic interpretation : the traditional FT measure shows the exponential of the extra information, measured in nats, relative to an untuned model that you must supply about a parameter in order to fit the 𝑍 mass. We derive the mathematical results underlying these interpretations, and explain them using examples from weak scale supersymmetry. These new interpretations allow us to rigorously define FT in particle physics and beyond, shed fresh light on the status of extensions to the Standard Model and, lastly, allow us to precisely reinterpret historical and recent studies using traditional FT measures.

electroweak symmetry breaking↗

Geometric Structure and Transversal Logic of Quantum Reed–Muller Codes

Designing efficient and noise-tolerant quantum computation protocols generally begins with an understanding of quantum error-correcting codes and their native logical operations. The simplest class of native operations are transversal gates, which are naturally fault-tolerant. Here, in this paper, we aim to characterize the transversal gates of quantum Reed–Muller (RM) codes by exploiting the well-studied properties of their classical counterparts. We start our work by establishing a new geometric characterization of quantum RM codes via the Boolean hypercube and its associated subcube complex. More specifically, a set of stabilizer generators for a quantum RM code can be described via transversal X and Z operators acting on subcubes of particular dimensions. This characterization leads us to define subcube operators composed of single-qubit π/2 k Z -rotations that act on subcubes of given dimensions. We first characterize the action of subcube operators on the code space: depending on the dimension of the subcube, these operators either (1) act as a logical identity on the code space, (2) implement non-trivial logic, or (3) rotate a state away from the code space. Second, and more remarkably, we uncover that the logic implemented by these operators corresponds to circuits of multi-controlled-Z gates that have an explicit and simple combinatorial description. Overall, this suite of results yields a comprehensive understanding of a class of natural transversal operators for quantum RM codes.

Reed–Muller (RM) codes↗

qSIEVE: Efficient qLDPC Memory via Systolic Movement in Atom Arrays

As quantum machines have scaled up in their number of qubits, significant research has turned towards increasing their fidelity with quantum error correction codes. Although promising results have been shown with the surface code, which only requires near-neighbor connections between qubits, the high qubit overhead of such local codes promises to be problematic. Consequently, recent work has explored non-local quantum LDPC (qLDPC) codes, which have good asymptotic encoding rates. Despite theoretical progress, hardware implementations of these codes have been a longstanding challenge. At the experimental level, demonstrations of movement based communication on atom arrays suggest this is a powerful new primitive to achieve non-local connectivity. Leveraging this, we present a protocol for implementing non-local qLDPC codes in hardware. Our protocol, qSIEVE, is a co-design of such codes with movement in atom arrays. qSIEVE defines a restricted family of qLDPC codes that can be implemented efficiently with systolic movement. We then quantify the utility of qSIEVE in the context of a complete fault tolerant architecture. We compare the cost of implementing benchmark programs in a standard, surface code only architecture and a mixed architecture where data is stored in qLDPC memory with qSIEVE and loaded to surface codes for computation.

Quantum error correction↗

A Comparative Evaluation and Selection of High-Temperature Heat Exchangers for Application to Integrated Energy Systems

The following report aims to create a refined and well-structured method for comparatively evaluating heat exchanger technologies for integrated energy systems that caters customers’ specific needs while meeting engineering requirements. For the evaluation, this study elevates previous evaluation metrics, enhances the knowledge base via literature and market surveys, and identifies the figures of merit with robust rationales to enhance the quality of decisions made throughout the proposed heat exchanger evaluation process. The heat exchanger designs evaluated as part of the case study are shell and tube heat exchangers, printed circuit heat exchangers, plate heat exchangers, spiral heat exchangers, and heat pipe heat exchangers. The information presented in this report is meant for industries interested in making a preliminary screening process to identify the most suitable heat exchanger design for their application of interest.

42 ENGINEERING↗

Evaluation of Heat Exchanger Technology for Integrated Energy System: Methodology and Preliminary Application

This report proposes a novel heat exchanger evaluation method, based on integrated QFD-AHP technique, to support strategic optimal selection of heat exchanger (HX) technology for integrated energy systems. The term “optimal selection” is defined as selecting a product (i.e., HX) that best meets various aspects of end user demand, including both technical and economic requirements. Compared to previous HX evaluation methods, the proposed approach allows decision makers to explicitly take into account the practical demand of customers (i.e., HX end users) which may vary depending on the HX application target. In addition, the proposed evaluation method can be used not only for high-level decisions to select HX type, but also for low-level decisions such as the selection of the key components including HX material or heat transfer fluid. The focus of this study is to describe the new HX evaluation method and to illustrate the overall HX evaluation and selection processes using the three nuclear heat application cases that represent the thermal integration between advanced nuclear reactors and industrial processes. As a preliminary study, three different types of HX, i.e., shell-and-tube heat exchanger, printed circuit heat exchanger, and heat pipe heat exchanger, were compared.

42 ENGINEERING↗

A Comparative Evaluation and Selection of High-Temperature Heat Exchangers for Application to Integrated Energy Systems

The following report aims to create a refined and well-structured method for comparatively evaluating heat exchanger technologies for integrated energy systems that caters customers’ specific needs while meeting engineering requirements. For the evaluation, this study elevates previous evaluation metrics, enhances the knowledge base via literature and market surveys, and identifies the figures of merit with robust rationales to enhance the quality of decisions made throughout the proposed heat exchanger evaluation process. The heat exchanger designs evaluated as part of the case study are shell and tube heat exchangers, printed circuit heat exchangers, plate heat exchangers, spiral heat exchangers, and heat pipe heat exchangers. The information presented in this report is meant for industries interested in making a preliminary screening process to identify the most suitable heat exchanger design for their application of interest.

42 - ENGINEERING↗