Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Preliminary Pilot-scale Study and Techno-economic Analysis of Chemical Heat Pump with Conventional Nuclear Reactors

The energy economy is continually evolving, particularly in terms of primary energy sources, their conversions to useful forms such as electricity and heat, and their utilization in different sectors, in response to socio-political factors. Because nuclear source is clean and non-carbon-emitting energy source, it is crucial to consider its role in the evolution of the energy economy. A pilot-scale study was conducted for Chemical Heat Pump (ChHP) system at three different scales (25-, 100-, and 1000-kW thermal outputs) using steady state thermal model. To establish the viability of selling heat rather than electricity alone, techno-economic analysis was undertaken for advanced Small Modular Reactor (SMR), and SMR paired with varied thermal output ChHP systems was referred to as the nuclear hybrid energy system (NHES) in this study. Using the U.S. Energy Information Administration statistics, pricing for electricity and natural gas were anticipated for U.S. regions (California, Northwest, Midwest, Southwest, New England, and PJM). Based on thermal output from ChHP, advanced SMR with 100 MWth and four alternative NHES scenarios were explored, namely 50-, 10-, 5-, and 1-MWth. Net present value, payback period, discounted cash flow return, and levelized cost of energy were evaluated for all scenarios. Based on the economic analysis, selling heat to high-temperature industrial processes is more profitable compared to selling electricity only. Higher carbon taxes showed significant improvement in economic parameters for NHESs. Providing heat to high-temperature industries could be beneficial, helping to reduce the greenhouse gas emissions by slashing the fossil fuel consumption.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of a Fluidized-Bed Particle/Supercritical-CO2 Heat Exchanger in a Concentrating Solar Power System

Concentrating solar power (CSP) development has focused on increasing the energy conversion efficiency and lowering the capital cost. To improve performance, CSP research is moving to high-temperature and high-efficiency designs. One technology approach is to use inexpensive, high-temperature heat transfer fluids and storage, integrated with a high-efficiency power cycle such as the supercritical carbon dioxide (sCO 2 ) Brayton power cycle. The sCO 2 Brayton power cycle has strong potential to achieve performance targets of 50% thermal-to-electric efficiency and dry cooling at an ambient temperature of up to 40 °C and to reduce the cost of power generation. Solid particles have been proposed as a possible high-temperature heat transfer or storage medium that is inexpensive and stable at high temperatures above 1000 °C. The particle/sCO 2 heat exchanger (HX) provides a connection between the particles and sCO 2 fluid in emerging sCO 2 power cycles. This article presents heat transfer modeling to analyze the particle/sCO 2 HX design and assess design tradeoffs including the HX cost. The heat transfer process was modeled based on a particle/sCO 2 counterflow configuration, and empirical heat transfer correlations for the fluidized bed and sCO 2 were used to calculate heat transfer area and estimate the HX cost. A computational fluid dynamics simulation was applied to characterize particle distribution and fluidization. This article shows a path to achieve the cost and performance objectives for a particle/sCO 2 HX design by using fluidized-bed technology.

14 SOLAR ENERGY↗

Design, Fabrication and On-Sun Performance Evaluation of SiC Receiver Feature Specimens for CST Applications Using Additively Manufactured SiC Materials

Increasing operating temperatures of solar receivers is paramount to the efficiency of concentrated solar thermal (CST) and solar power (CSP) systems. Successful development of CST systems to generate heat for industrial applications requires significant increase in temperature capability and techno-economically viability of the receiver systems. Supported by an award from the Solar Technology Office (SETO), US Department of Energy (DOE), GE Aerospace Research in collaboration with Heliogen Holdings Inc and Sandia National Lab, is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing. The program objective is to demonstrate SiC receiver with air exit temperatures up to 1100 oC and high thermal efficiencies. We report design, fabrication and on-sun test results of SiC components of a prototype 50kW (thermal) HOTSSTAR module. The receiver module architecture is based on a radial airflow design and consists of a series of radial SiC receiver sectors organized around a SiC center absorber. The SiC components are fabricated using binder-jet printed SiC followed by melt-infiltration reaction bonding process. To enhance the reliability and to minimize the risk of cracking damage of SiC test articles in thermal gradient and thermal shock environment of the application, the components were laminated with GE’s MI SiC-SiC CMC. Following extensive design and lab test analyses, selected SiC component designs are tested at Heliogen Lancaster Solar field under highly concentrated solar fluxes around 2000 suns to assess the thermal performance characteristics under realistic field conditions. We report on the test results and compare the thermal performances of different HOTSSTAR SiC absorbers. Finally, we discuss fabrication and initial assembly of a 50kW prototype test module in preparation of on-sun field tests to assess the performance of our final design.

CST, CSP, high temperature, air receiver, SiC, add↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units with Original Fuel Backup

This documentation focuses on a single end-use savings shape measure—heat pump rooftop units with supplemental heat that matches the original fuel type of the replaced system; if the existing system used electric resistance heating, the supplemental heating source is electric resistance. If it was a natural gas furnace, the supplemental system is modeled as natural gas. This is a modification to the heat pump rooftop unit with electric supplemental heat measure from the Commercial EUSS 2023 Release 1 dataset. This document will primarily discuss the supplemental heating change for the heat pump RTU measure. For a comprehensive overview of the fundamental modeling methodology and background of the heat pump RTU measure, including performance curves and other key assumptions, please review the documentation for the original heat pump rooftop unit with electric supplemental heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Environmental Impact Calculations for Geothermal DDU system on WVU Campus

This dataset contains all the inputs used and output produced from Matlab for the environmental analysis of an improved hybrid geothermal district heating and cooling (GDHC) system with a heat pump, without a heat pump, and for a hot water GDHC. Detailed descriptions of the contents of this repository are provided below.

15 GEOTHERMAL ENERGY↗

Organic Rankine Cycle Integration and Optimization for High Efficiency CHP Genset Systems (Final Technical Report)

This project successfully advanced the integration of Organic Rankine Cycle (ORC) technology with reciprocating engine–based combined heat and power (CHP) systems to improve electrical efficiency, total CHP efficiency, and grid-responsive operation. Over three budget periods, the work progressed from high-temperature ORC component development and thermodynamic model validation to next-generation system design, working fluid transition, and techno-economic analysis. Key technical accomplishments include development and validation of a thermodynamic model capable of accurately predicting ORC performance across an expanded temperature and pressure envelope; successful identification and validation of low-global-warming-potential (GWP) working fluids—most notably R1233zd(E)—as viable replacements for R245fa; and demonstration of scalable ORC architectures suitable for integration with 1–20 MW class reciprocating engines. These advances enable flexible CHP configurations that can increase electrical output while maintaining high overall utilization of available thermal energy. The project also produced a clean-sheet design for a next-generation ORC system targeting substantially higher power output per unit, supported by detailed component selection, heat exchanger evaluation, and system-level modeling. Techno-economic analyses indicate that ORC-enabled flexible CHP systems can meet or exceed Department of Energy (DOE) efficiency targets while providing value to both facility operators and the electric grid.. Late-stage testing of the largest next-generation ORC prototype identified limitations related to pump net positive suction head (NPSH) requirements and condenser flooding under certain operating conditions. Although these issues constrained full validation of that configuration within the project timeframe, they provided clear and actionable design guidance for future system refinements. Importantly, validated modeling, smaller-scale testing, and working fluid evaluations confirmed the technical viability of the overall approach. In aggregate, this project met its core objectives by establishing validated design tools, de-risking key ORC technologies for CHP applications, and defining a credible pathway toward commercialization of flexible, high-efficiency CHP systems. The results form a strong foundation for continued development and deployment beyond the conclusion of the DOE-funded effort.

20 FOSSIL-FUELED POWER PLANTS↗

Solar+Storage for Household Back-up Power: Implications of building efficiency, load flexibility, and electrification for backup during long-duration power interruptions [Slides]

The study analyzes the evolving role of solar+storage for home backup power during long-duration power interruptions. In particular, it evaluates how required storage sizing is impacted as homes become more efficient, flexible, and electrified. The study relies on NREL’s ResStock building modeling platform to create statistically representative distributions of the existing building stock in ten locations across the United States. It then shows how the amount battery storage required for backup power rises or falls as a series of building envelope efficiency, load flexibility, and electrification measures are applied across the building stock in each region. The study also includes sensitivities to show how backup power requirements are impacted by the timing and duration of power interruptions, and explores variation in backup power requirements across the building stock within each study location. The results demonstrate the value of pairing solar+storage with efficiency upgrades, smart home controls, and (in mild winter climates) efficient heat pump retrofits. That value comes in the form of reducing the amount of storage required and/or extending the range of interruption conditions over which a given system can provide backup power (i.e., more extreme weather and/or longer interruptions). Heat pumps in cold-weather climates can pose a challenge for solar+storage backup power, given the amount of storage required, though are a vast improvement over electric-resistance heating. Retaining existing fossil-based heating systems for occasional use during power interruptions, as either the primary or supplementary source of heat, can mitigate this challenge. Other forms of building electrification (e.g., cooking and water heating) generally have marginal impacts on backup battery sizing, given their relatively small energy demand.

14 SOLAR ENERGY↗

Design-Point Techno-Economics of Brayton Cycle PTES for Combined Heat and Power

Pumped thermal energy storage (PTES) systems are grid batteries that use heat pumps to create both hot and cold thermal energy stores when there is excess electricity and then use a power cycle to convert the thermal energy into electricity when there is demand for electricity. In normal operation, Joule–Brayton PTES discharges low-grade heat at temperatures useful for thermal energy consumers like district and industrial heating. Furthermore, PTES designs, like conventional combined heat and power (CHP) technology, can be modified to sacrifice some round-trip efficiency (RTE) to increase the temperature of heat rejection. Here, this paper uses design-point performance and cost models that provide a detailed understanding of the efficiency and cost tradeoffs of rejecting heat at various temperatures in ideal-gas Brayton PTES configurations. First, we keep the heat rejection in its nominal location in the PTES system: in the discharge cycle after the low-pressure exit of the recuperator before the cold-storage heat exchanger. Next, we move the heat rejection to the discharge turbine exit. We define design-point metrics that isolate both the cost and performance penalty associated with the hotter heat rejection and attribute it exclusively to the heat economic metrics. Finally, we estimate the performance of electric heater technology to generate heat at equivalent temperatures. We find that the levelized cost of heat (LCOH), including the cost of thermal energy storage (TES) buffering the PTES and heat off-taker, compares favorably versus electric technologies and is less than the cost of natural gas for low temperature scenarios and competitive with the cost of natural gas in some regions of the contiguous U.S. in high temperature scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design-Point Techno-Economics of Brayton Cycle PTES for Combined Heat and Power

Pumped thermal energy storage (PTES) systems are grid batteries that use heat pumps to create both hot and cold thermal energy stores when there is excess electricity and then use a power cycle to convert the thermal energy into electricity when there is demand for electricity. In normal operation, Joule-Brayton PTES discharges low-grade heat at temperatures useful for thermal energy consumers like district and industrial heating. Furthermore, PTES designs, like conventional combined heat and power (CHP) technology, can be modified to sacrifice some round-trip efficiency RTE to increase the temperature of heat rejection. This paper uses design-point performance and cost models that provide a detailed understanding of the efficiency and cost trade-offs of rejecting heat at various temperatures in ideal-gas Brayton PTES configurations. First, we keep the heat rejection in its nominal location in the PTES system: in the discharge cycle after the low-pressure exit of the recuperator before the cold-storage heat exchanger. Next, we move the heat rejection to the discharge turbine exit. We define design-point metrics that isolate both the cost and performance penalty associated with the hotter heat rejection and attribute it exclusively to the heat economic metrics. Finally, we estimate the performance of electric heater technology to generate heat at equivalent temperatures. We find that the levelized cost of heat, including the cost of thermal energy storage (TES) buffering the PTES and heat off-taker, compares favorable versus electric technologies and is less than the cost of natural gas for low temperature scenarios and competitive with the cost of natural gas in some regions of the contiguous United States in high temperature scenarios.

CHP↗

Direct contact particle-fluid heat exchanger

The present disclosure is directed to systems and methods that transfer heat directly from hot particles to a cold fluid, such as sCO 2 , by bringing the hot particles and cold fluid into direct contact at the operating pressure of the cold fluid. These systems and methods can both stand-off large pressure differentials while allowing particles to pass through and limiting cold fluid leakage either continuously or through a batch process.

Carlson, Matthew D.↗

Experimental investigation of Multi-Mode heat transfer to a Free-Falling dilute particle cloud in a heated vertical tube

The development of dilute particle heat exchangers and reactors for advanced energy systems requires an understanding of the multi-mode heat transfer from a heated wall to falling particles. This study presents experimental results of the overall heat transfer coefficient for a free-falling, dilute flow of particles with solid volume fraction from 0.0005 to 0.006 corresponding to feed rates from 3.7 kg s -1 m -2 to 44 kg s -1 m -2 in a vertical, heated tube containing quiescent air at atmospheric pressure. Tube wall temperatures are varied between 300°C to 900°C while keeping the particle inlet temperature constant. The experimental results show that the overall heat transfer coefficient is a strong function of particle feed rate and surface temperature. Good agreement was obtained with prior studies conducted at comparable temperatures but lower particle feed rates (< 4 kg m -2 s -1 ). The established correlations for particle-to-wall radiation and particle-to-gas convection were used to estimate the wall-to-gas convective contribution from the measured overall heat transfer coefficient. The experimental results indicated a 4 to 6 times improvement in the wall convection in the solid-gas mixture compared to that expected from natural convection in a single-phase gas. Furthermore, the data presented here are applicable to characterize heat transfer in dilute particle heat exchangers, furnaces, and solar receivers.

14 SOLAR ENERGY↗

Competitiveness Assessment of Decarbonizing Electricity and Process Heat Supply to a Campus with a Small Nuclear Reactor

This paper analyzes the competitiveness of siting a small nuclear reactor to support decarbonization of sites requiring tens of MW of electricity and/or process heat to support centralized heating and cooling system. This paper focuses on campuses as representative of sites with collections of buildings and research facilities with decarbonization needs represented by buildings heating, and electricity consumption by electrical loads which may include cooling via chilled water (e.g., for air conditioning and to cool down computer clusters). A nuclear reactor can be considered to decarbonize a site’s high-temperature steam generation used mostly for building heating needs, climate control, and hot water, by supplying process heat capabilities, while electricity decarbonization would be achieved mostly by the grid. However, a secondary application can be considered to maximize reactor utilization and avoid ramping down the reactor if the steam demand varies significantly throughout the year. Chilled water generation through steam-driven systems was identified as an attractive secondary option for the site analyzed, due to potential for plant design simplification, while electricity generation could be considered as well to reduce electricity purchases for a wider range of site applications. For a campus with peak 60MW thermal power demand, a small nuclear reactor with similar thermal power rating would almost eliminate CO2 emissions from steam generation and reduce electricity imports for chilled water production. A preliminary techno-economic feasibility study shows that a small nuclear reactor design that is optimized to support process heat can represent an economically feasible option when compared with other decarbonization alternatives.

Stauff, Nicolas E.↗

District heating utilizing waste heat of a data center: High-temperature heat pumps

Data centers are energy-intensive facilities with substantial low-grade waste heat. High-temperature heat pumps can be critical in boosting the data center’s waste heat for district heating, improving the system-level energy efficiency of data centers, and reducing CO 2 emissions in district heating. This study built thermodynamic models to assess high-temperature heat pumps with six configurations using low global warming potential refrigerants to supply heat up to 120 °C. The heat pump configurations include single-stage or two-stage cycles with advanced components, such as internal heat exchanger, economizer, flash tank, or parallel compressor. The refrigerants include R1234ze(Z), R1233ed(E), R1224yd(Z), R600, and R600a, and R245fa is used as a reference. A case study was carried out to recover the waste heat from the Frontier high-performance computing data center and provide hot water for district heating at the US Department of Energy’s Oak Ridge National Laboratory campus. The optimized performance of high-temperature heat pumps is characterized with various effectiveness of internal heat exchangers, and the operating parameters of economizer or flash tank, as well as their combination. The results show that the configurations of two-stage cycles with internal heat exchanger + flash tank and internal heat exchanger + economizer/parallel-compressor provide the highest coefficient of performance under scenarios of the maximum allowable value and a fixed value (0.3) of the internal heat exchangers’ effectiveness, respectively. R1234ze(Z) and R600a are the most promising refrigerants, considering trade-offs between the coefficient of performance and the volumetric heating capacity. The single-stage cycle with internal heat exchanger + economizer/parallel-compressor using R1234ze(Z) is recommended for utilizing Fronter’s waste heat in district heating. A one mega-watt high-temperature heat pump will reduce 33,100–33,200 metric tons of CO2 emission annually, corresponding to 85.4 %–85.6 % of equivalent CO2 emissions from natural gas boilers. Here, this study provides good guidelines for designing and deploying high-temperature heat pumps to support sustainable data centers and decarbonize district heating in the US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Interface and Thermophysical Properties of R 32 Refrigerant

Driven by the urgent demand for efficient cooling in microelectronics and advanced thermal management systems, difluoromethane (R32/CH 2 F 2 ) has emerged as a promising candidate owing to its favorable thermophysical properties, including high heat transfer efficiency and low viscosity. While bulk properties such as density, viscosity, and thermal conductivity have been widely studied, interfacial properties, including surface tension and interfacial thickness, remain comparatively underexplored, despite their importance in phase-transition dynamics. Here, we perform molecular dynamics (MD) simulations from 180 to 300 K using an optimized transferable force field for fluoropropenes with enhanced electrostatics to assess both bulk and interfacial behavior of R32. Simulations reproduced density within ±2.1%, viscosity within 3.05%, and thermal conductivity within 7.41% of NIST reference data. Heat capacities (C p and C v ) were predicted within 5%. For interfacial properties, surface tension trends were reproduced within 13.58% deviation, and the vapor–liquid coexistence curve closely matched reference data, yielding a critical temperature of 345.7 K (1.6% deviation) and a critical density of 0.397 g/cm 3 (6.4% deviation). Importantly, the vapor–liquid interface exhibited pronounced temperature-dependent broadening across the 180–290 K range. This behavior correlates with increasing molecular kinetic energy, reduction in intermolecular cohesive interactions, and a progressive loss of preferential dipole alignment, which collectively enhance thermal fluctuation amplitudes at elevated temperatures. These validated results provide predictive molecular-level insights, particularly for interfacial properties that remain less characterized. By reducing property prediction errors in key parameters such as critical temperature, this work provides reliable inputs for heat-exchanger and system models. Such correlations can support optimized component sizing, improved performance, and reduced refrigerant charge. Beyond R32, the methodology offers a transferable framework for blended and next-generation low-GWP refrigerants, contributing to sustainable thermal management aligned with the 2027 EU F-Gas regulation and 2030 Kigali Amendment.

Fluids↗

Integration of Thermoelectric Modules to Vapor Compression Systems

This paper describes the technology of a thermoelectric (TE) integrated heat pump. It uses a TE heat pump to subcool the refrigerant liquid before entering the evaporator to enlarge the evaporating capacity; and elevate the heat in the refrigerant flow to a supplemental heating coil and discharge the capacity to the indoor air flow. Using the DOE/ORNL Heat Pump Design Model, four system configurations were modelled on a baseline two-speed heat pump, the baseline heat pump with adding a supplemental coil, the TE integrated heat pump having one stage TE heating to control a 20R liquid refrigerant temperature drop; and having two stages TE heating to control up to 40R temperature drop. The system models were used to produce performance curves for EnergyPlus building energy simulations. We selected template residential buildings, poorly insulated: pre-1990 buildings, and well-insulated: IECC2021 buildings; in five cold climate zones: 5A, 5B, 6A, 6B, 7. The building energy simulations demonstrated energy saving potentials, utility cost reductions and estimated payback periods.

Shen, Bo↗

Comparative Analysis of Direct and Indirect Cooling of Wide-Bandgap Power Modules and Performance Enhancement of Jet Impingement-Based Direct Substrate Cooling

With the development of high-power and high-torque machines, requirements for high-power density electronics are increasing. Thermal management of such systems requires high heat extraction. Conventional air cooling based heat sinks and cold plate based liquid cooling have their own benefits for various applications but has limitations for high power density applications. The current study explores a jet impingement based direct substrate cooling system that was implemented for a SiC based direct bonded Cu substrate for various power losses. Numerical comparison between jet impingement cooling and conventional horizontal/indirect cooling (pin fin heat sink and genetic algorithm-optimized heat sink) showed that the area weighted average of the heat transfer coefficient (HTC) is high for both horizontal cooling designs, and the local HTC is higher for jet impingement. Design iterations were undertaken to resolve the bottleneck of this cooling system. Increasing the number of nozzles helped to cover more area at the direct bonded Cu bottom plate, which drops the chip temperature considerably. With a constant flow rate, increasing the number of nozzles would decrease local jet velocity, which reduces the heat extraction by jet impingement. This issue can be addressed by reducing the diameter of nozzle but doing so results in a high pressure drop where the design constraint is 2 psi. A flared nozzle design is proposed, which has a higher spreading angle of the jet that increases the flow coverage and reduces the pressure drop of the coolant loop.

Barua, Himel↗

Method to fill heat pipe arrays

A fill tool system that fills, seals, and inspects a heat pipe array, which includes one or more heat pipes with heat pipe working fluid.

Reid, Robert S.↗