Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error bars”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Study of exclusive B → X u ℓ ν decays and extraction of | V u b | using full reconstruction tagging at the Belle experiment

Here, we report the results of a study of the exclusive semileptonic decays B - → π 0 ℓ - ν ¯ ℓ , B ¯ 0 → π + ℓ - ν ¯ ℓ , B - → ρ 0 ℓ - ν ¯ ℓ , B ¯ 0 → ρ + ℓ - ν ¯ ℓ and B - → ω ℓ - ν ¯ ℓ , where ℓ represents an electron or a muon. The events are tagged by fully reconstructing a second B meson in the event in a hadronic decay mode. The measured branching fractions are B ( B - → π 0 ℓ - ν ¯ ℓ ) = ( 0.80 ± 0.08 ± 0.04 ) × 10 - 4 , B ( B ¯ 0 → π + ℓ - ν ¯ ℓ ) = ( 1.49 ± 0.09 ± 0.07 ) × 10 - 4 , B ( B - → ρ 0 ℓ - ν ¯ ℓ ) = ( 1.83 ± 0.10 ± 0.10 ) × 10 - 4 , B ( B ¯ 0 → ρ + ℓ - ν ¯ ℓ ) = ( 3.22 ± 0.27 ± 0.24 ) × 10 - 4 , and B ( B - → ω ℓ - ν ¯ ℓ ) = ( 1.07 ± 0.16 ± 0.07 ) × 10 - 4 , where the first error is statistical and the second one is systematic. The obtained branching fractions are inclusive of soft photon emission. Furthermore, we determine the branching fractions as a function of the 4-momentum transfer squared to the leptonic system q 2 = ( p ℓ + p ν ) 2 , where p ℓ and p ν are the lepton and neutrino 4-momenta, respectively. Using the pion modes, a recent light cone sum rule calculation, lattice QCD results and a model-independent description of the hadronic form factor, a value of the Cabibbo-Kobayashi-Maskawa matrix element | V u b | = ( 3.52 ± 0.29 ) × 10 - 3 is extracted. A structure in the two-pion invariant mass distribution near 1.3 GeV / c 2 , which might be dominated by the decay B - → f 2 ( 1270 ) ℓ - ν ¯ ℓ , f 2 → π + π - , is seen. These results are obtained from a 711 fb - 1 data sample that contains 772 × 10 6 B B ¯ pairs, collected near the Υ ( 4 S ) resonance with the Belle detector at the KEKB asymmetric-energy e + e - collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Schuler Period in LEO Satellites

This paper generalizes and extends the concept of the Schuler oscillation that occurs in the theory of inertial navigation systems, allowing one to see how the Schuler phenomenon affects inertial navigation systems operating in space. We show why a low earth orbit satellite's orbital period is identical to the period of the Schuler pendulum, which is the period of the errors for terrestrial inertial navigation systems. We also show that the generalized form of the Schuler oscillation takes the same form as the Hill-Clohessy-Wiltshire equations for satellite relative motion and that the period of the out-of-plane motion in neighboring satellite relative trajectories is the same as the Schuler period. Finally, we describe how INS gyro drift manifests itself in different coordinate systems for the orbital case. These results may assist orbital flight dynamics and attitude control systems engineers in the design and analysis of INS-equipped spacecraft

Carpenter, Russell J.↗

The Charge Asymmetry in $W$ Boson Production in $p\bar p$ Collisions at the $\sqrt{s} = 1.96$ TeV Using the D0 Detector at the Fermilab Tevatron

We present a measurement of the W boson charge asymmetry in p $\bar{p}$ collisions using W →ev decays using 750 pb -1 of data collected with the D detector at the Fermilab Tevatron. The electron coverage is extended to |η| < 3.2 and is thus sensitive to W s generated with low and high x partons. We also measured the charge asymmetry for events with electron E T > 25 GeV, 25 < E T < 35 GeV and E T > 35 GeV. By dividing events into di erent electron E T regions, we can probe di erent W boson rapidity regions, and can provide more constraints on the parton distribution functions (PDFs). Theoretical predictions made using CTEQ6.6 and MRST2004NLO PDFs are compared with the measurement. Our measurement is the most precise W charge asymmetry measurement to date, and this single measurement is superior in precision to the combined world average of all previous W charge asymmetry measurements done at the Tevatron. The measured asymmetry errors are less than the CTEQ6.6 PDF uncertainty for most rapidity bins. The inclusion of our results will further constrain future PDF ts and improve the predictions.

43 PARTICLE ACCELERATORS↗

Automatic Inspection of Aircraft Using Open-Architecture Robotic Platforms

Aging aircraft structures and composite materials are requiring rapid inspection of large areas. Removal from the aircraft for NDE at an inspection facility is not economical as compared to field inspection. Detection and characterization of defects are labor intensive, time consuming and when the process is manual the results are subjected to human error. These limitations of NDE created a need for portable, user friendly inspection systems that can rapidly scan large areas of complex structures and locate all the detrimental material conditions. Addressing this need has been an evolutionary process that followed the technology trend, and unique devices were developed to allow rapid field inspection. This development involves multi-disciplinary approaches to integrate NDE, telerobotics, neural networks, advanced materials science, imbedded computing and automated control. These efforts have led to the development of various portable inspection systems and the current trend is towards fully automatic systems that will operate autonomously.

Bar-Cohen, Yoseph↗

SU-E-J-53: A Phantom Design to Assist Patient Position Verification System in Daily Image-Guided RT and Comprehensive QA Measurements

Purpose This study is to implement a homemade novel device with surface locking couch index to check daily radiograph (DR) function of adaPTInsight™, stereoscopic image guided system (SIGS), for proton therapy. The comprehensive daily QA checks of proton pencil beam output, field size, flatness and symmetry of spots and energy layers will be followed by using MatriXX dosimetry device. Methods The iBa MatriXX device was used to perform daily dosimetry which is also used to perform SIGS checks. A set of markers were attached to surface of MatriXX device in alignment of DRR of reconstructed CT images and daily DR. The novel device allows MatriXX to be fit into the cradle which was locked by couch index bars on couch surface. This will keep the MatriXX at same XY plane daily with exact coordinates. Couch height Z will be adjusted according to imaging to check isocenter-laser coincidence accuracy. Results adaPTInsight™ provides robotic couch to move in 6-degree coordinate system to align the dosimetry device to be within 1.0 mm / 1.0°. The daily constancy was tightened to be ± 0.5 mm / 0.3° compared to 1.0 mm / 1.0° before. For gantry at 0° and couch all 0° angles (@ Rt ARM 0 setting), offsets measured of the couch systems were ≤ 0.5° in roll, yaw and pitch dimensions. Conclusion Simplicity of novel device made daily image guided QA consistent with accuracy. The offset of the MatriXX isocenter-laser coincident was reproducible. Such easy task not only speeds up the setup, but it increases confidence level in detailed daily comprehensive measurements. The total SIGS alignment time has been shortened with less setup error. This device will enhance our experiences for the future QA when cone beam CT imaging modality becomes available at proton therapy center.

60 APPLIED LIFE SCIENCES↗

MPACT Testing and Benchmarking Results

This document provides detailed reactivity and fission rate distribution results for MPACT for the Core Physics Benchmark Progression Problems 1-5, including comparisons to initial startup data from Watts Bar Nuclear Unit 1. Also included are computer requirements and runtimes for each type of problem and feedback for issues encountered during the testing. Testing for the benchmark problems that do not require thermal-hydraulic feedback has been very successful. Testing for the coupled problems (6 and 7) is still ongoing and will be documented in a future revision or separate document. A few issues have been identified needing more research/investigation before all of these problems have ideal solutions. These items are included in the Section 8 near the end of this document. MPACT has successfully solved all of the zero power core physics progression problems. The computer resources required and runtimes were all acceptable, though faster cases would be preferable considering there was no thermal-hydraulic feedback. MPACT converged very reliably for all 3D problems, expect in a few isolated studies where very thin axial planes were purposely created to attempt to quantify the errors in the control rod tip homogenization model. Despite the issues listed in Section 8, the accuracy of MPACT compared to the reference solution is considered to be very good.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimizing a dynamical decoupling protocol for solid-state electronic spin ensembles in diamond

In this study, we demonstrate significant improvements of the spin coherence time of a dense ensemble of nitrogen-vacancy (NV) centers in diamond through optimized dynamical decoupling (DD). Cooling the sample down to 77 K suppresses longitudinal spin relaxation T 1 effects and DD microwave pulses are used to increase the transverse coherence time T 2 from ~0.7ms up to ~30ms. Furthermore, we extend previous work of single-axis (Carr-Purcell-Meiboom-Gill) DD towards the preservation of arbitrary spin states. Following a theoretical and experimental characterization of pulse and detuning errors, we compare the performance of various DD protocols. We also identify that the optimal control scheme for preserving an arbitrary spin state is a recursive protocol, the concatenated version of the XY8 pulse sequence. The improved spin coherence might have an immediate impact on improvements of the sensitivities of ac magnetometry. Moreover, the protocol can be used on denser diamond samples to increase coherence times up to NV-NV interaction time scales, a major step towards the creation of quantum collective NV spin states.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of Mixing and CP Violation in the Two-Body D0 decays to KK, pipi and Kpi with the BaBar Experiment

In this thesis we present the measurement of D 0 - $\bar{D}$ 0 mixing parameter yCP using the full BABAR data sample. We also searched for CP violation in the D 0 → K + K - , π + π - channels, finding the parameter ΔY compatible with zero. In Chapter 1, we briefly review the SM and introduce the theoretical framework of neutral meson mixing and CP violation. The BABAR detector and the performance of each sub-detector are described in Chapter 2. In Chapter 3, we present an overview of the analysis including a brief description of the previous similar BABAR analyses and the expected improvements in the present analysis. The candidate reconstruction and selection are described in Chapter 4, together with the optimization of the signal region. The signal and background event classes are described in Chapter 5, where we also provide the probability density functions used to extract the mixing and CP violating parameter. In Chapter 6 we describe the various crosschecks performed to validate the analysis and the evaluation of the systematic error. Finally in Chapter 7 we present the final results and their interpretation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High precision tests of QCD without scale or scheme ambiguities: The 40th anniversary of the Brodsky–Lepage–Mackenzie method

A key issue in making precise predictions in QCD is the uncertainty in setting the renormalization scale μ r and thus determining the correct values of the QCD running coupling α s (μ r ) at each order in the perturbative expansion of a QCD observable. It has often been conventional to simply set the renormalization scale to the typical scale of the process Q and vary it in the range μ r $\in$ [Q/2, 2Q] in order to estimate the theoretical error. This is the practice of Conventional Scale Setting (CSS). The resulting CSS prediction will however depend on the theorist’s choice of renormalization scheme and the resulting pQCD series will diverge factorially. It will also disagree with renormalization scale setting used in QED and electroweak theory thus precluding grand unification. A solution to the renormalization scale-setting problem is offered by the Principle of Maximum Conformality (PMC), which provides a systematic way to eliminate the renormalization scale-and-scheme dependence in perturbative calculations. The PMC method has rigorous theoretical foundations, it satisfies Renormalization Group Invariance (RGI) and preserves all self-consistency conditions derived from the renormalization group. The PMC cancels the renormalon growth, reduces to the Gell-Mann–Low scheme in the N c → 0 Abelian limit and leads to scale- and scheme-invariant results. The PMC has now been successfully applied to many high-energy processes. In this article we summarize recent developments and results in solving the renormalization scale and scheme ambiguities in perturbative QCD. In particular, we present a recently developed method the PMC ∞ and its applications, comparing the results with CSS. The method preserves the property of renormalizable SU(N)/U(1) gauge theories defined as Intrinsic Conformality (iCF). This property underlies the scale invariance of physical observables and leads to a remarkably efficient method to solve the conventional renormalization scale ambiguity at every order in pQCD. This new method reflects the underlying conformal properties displayed by pQCD at NNLO, eliminates the scheme dependence of pQCD predictions and is consistent with the general properties of the PMC. A new method to identify conformal and β-terms, which can be applied either to numerical or to theoretical calculations is also shown. We present results for the thrust and C-parameter distributions in e + e - annihilation showing errors and comparison with the CSS. We also show results for a recent innovative comparison between the CSS and the PMC ∞ applied to the thrust distribution investigating both the QCD conformal window and the QED N c → 0 limit. In order to determine the thrust distribution along the entire renormalization group flow from the highest energies to zero energy, we consider the number of flavors near the upper boundary of the conformal window. In this flavor-number regime the theory develops a perturbative infrared interacting fixed point. These results show that PMC ∞ leads to higher precision and introduces new interesting features in the PMC. In fact, this method preserves with continuity the position of the peak, showing perfect agreement with the experimental data already at NNLO. We also show a detailed comparison of the PMC ∞ with the other PMC approaches: the multi-scale-setting approach (PMCm) and the single-scale-setting approach (PMCs) by comparing their predictions for three important fully integrated quantities R e+e- , R$_Τ$ and Γ (H→$b\bar{b}$) up to the four-loop accuracy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-492: Implementing a Method for Brain Irradiation in Rats Utilizing a Commercially Available Radiosurgery Irradiator

Purpose: The purpose of the study was to implement a method for accurate rat brain irradiation using the Gamma Knife Perfexion unit. The system needed to be repeatable, efficient, and dosimetrically and spatially accurate. Methods: A platform (“rat holder”) was made such that it is attachable to the Leskell Gamma Knife G Frame. The rat holder utilizes two ear bars contacting bony anatomy and a front tooth bar to secure the rat. The rat holder fits inside of the Leskell localizer box, which utilizes fiducial markers to register with the GammaPlan planning system. This method allows for accurate, repeatable setup.A cylindrical phantom was made so that film can be placed axially in the phantom. We then acquired CT image sets of the rat holder and localizer box with both a rat and the phantom. Three treatment plans were created: a plan on the rat CT dataset, a phantom plan with the same prescription dose as the rat plan, and a phantom plan with the same delivery time as the rat plan. Results: Film analysis from the phantom showed that our setup is spatially accurate and repeatable. It is also dosimetrically accurate, with an difference between predicted and measured dose of 2.9%. Film analysis with prescription dose equal between rat and phantom plans showed a difference of 3.8%, showing that our phantom is a good representation of the rat for dosimetry purposes, allowing for +/- 3mm diameter variation. Film analysis with treatment time equal showed an error of 2.6%, which means we can deliver a prescription dose within 3% accuracy. Conclusion: Our method for irradiation of rat brain has been shown to be repeatable, efficient, and accurate, both dosimetrically and spatially. We can treat a large number of rats efficiently while delivering prescription doses within 3% at millimeter level accuracy.

60 APPLIED LIFE SCIENCES↗

A LEO Satellite Navigation Algorithm Based on GPS and Magnetometer Data

The Global Position System (GPS) has become a standard method for low cost onboard satellite orbit determination. The use of GPS as an attitude and rate sensor has also been developed in the recent past. Additionally, focus has been given to attitude and orbit estimation using the magnetometer, a low cost, reliable sensor. Combining measurements from both GPS and a magnetometer can provide a robust navigation system which takes advantage of the estimation qualities of both measurements. Ultimately a low cost, accurate navigation system can result, potentially eliminating the need for more costly sensors, including gyroscopes. This work presents the development and preliminary testing of a unified navigation algorithm which produces estimates of attitude, angular rate, position, and velocity for a low earth orbit (LEO) spacecraft. The system relies on GPS phase, range, and range rate data as well as magnetometer data. The algorithm used is an extended Kalman filter (EKF) developed to provide LEO attitude, orbit, and rate estimates using magnetometer and sun sensor data. Incorporating sun sensor data into the EKF improved the attitude and rate estimates. For many LEO spacecraft the sun data is available during only a portion of the orbit. However, GPS data is available continuously throughout the orbit. GPS can produce accurate orbit estimates and combining GPS and magnetometer data improves the attitude and rate estimates. The magnetometer based EKF can converge from large initial errors in position, velocity, and 3 attitude . Combining the magnetometer and GPS data into a single EKF will provide a more robust and accurate system. The EKF is based on an existing EKF. The GPS measurement models for phase, range, and range rate are incorporated into the existing structure of the filter. The original EKF produced the orbit estimates in terms of Keplerian elements. Due to the nature of the GPS measurements and ease of computation, the orbit estimates are converted to the Cartesian position and velocity. The measurement model for the magnetometer is adjusted for this change in the state and the measurements. Preliminary test results based on simulated GPS and magnetometer data are included.

Deutschmann, Julie↗

Measurements of Time-Dependent CP-Asymmetry Parameters in B Meson Decays to η' K 0 and of Branching Fractions of SU(3) Related Modes with BaBar Experiment at SLAC

In this thesis work we have measured the following upper limits at 90% of confidence level, for B meson decays (in units of 10 -6 ), using a statistics of 465.0 x 10 6 B$\bar{B}$ pairs: β(B 0 → ηK 0 ) < 1.6 β(B 0 → ηη) < 1.4 β(B 0 → η'η') < 2.1 β(B 0 → ηΦ) < 0.52 β(B 0 → ηω) < 1.6 β(B 0 → η'Φ) < 1.2 β(B 0 → η'ω) < 1.7 We have no observation of any decay mode, statistical significance for our measurements is in the range 1.3-3.5 standard deviation. We have a 3.5σ evidence for B → ηω and a 3.1 σ evidence for B → η'ω. The absence of observation of the B 0 → ηK 0 open an issue related to the large difference compared to the charged mode B + → ηK + branching fraction, which is measured to be 3.7 ± 0.4 ± 0.1 [118]. Our results represent substantial improvements of the previous ones [109, 110, 111] and are consistent with theoretical predictions. All these results were presented at Flavor Physics and CP Violation (FPCP) 2008 Conference, that took place in Taipei, Taiwan. They will be soon included into a paper to be submitted to Physical Review D. For time-dependent analysis, we have reconstructed 1820 ± 48 flavor-tagged B 0 → η'K 0 events, using the final BABAR statistic of 467.4 x 10 6 B$\bar{B}$ pairs. We use these events to measure the time-dependent asymmetry parameters S and C. We find S = 0.59 ± 0.08 ± 0.02, and C = -0.06 ± 0.06 ± 0.02. A non-zero value of C would represent a directly CP non-conserving component in B 0 → η'K 0 , while S would be equal to sin2β measured in B 0 → J/ΨK s 0 [108], a mixing-decay interference effect, provided the decay is dominated by amplitudes of a single weak phase. The new measured value of S can be considered in agreement with the expectations of the 'Standard Model', inside the experimental and theoretical uncertainties. Inconsistency of our result for S with CP conservation (S = 0) has a significance of 7.1 standard deviations (statistical and systematics included). Our result for the direct-CP violation parameter C is 0.9 standard deviations from zero (statistical and systematics included). Our results are in agreement with the previous ones [18]. Despite the statistics is only 20% larger than the one used in previous measurement, we improved of 20% the error on S and of 14% the error on C. This error is the smaller ever achieved, by both BABAR and Belle, in Time-Dependent CP Violation Parameters measurement is a b → s transition.

43 PARTICLE ACCELERATORS↗

Results of the Magnetometer Navigation (MAGNAV) Inflight Experiment

The Magnetometer Navigation (MAGNAV) algorithm is currently running as a flight experiment as part of the Wide Field Infrarad Explorer Post-Science Engineer- ing Testbed. Initialization of MAGNAV occured on September 4, 2004. MAGNAV is designed to autonomously estimate the spacecraft orbit, attitude, and rate using magnetometer and sun sensor data. Since the earth s magnetic field is a function of time and position, and since time is known quite precisely, the differences between the computed magnetic field and measured magnetic field components, as measured by the magnetometer throughout the entire spacecraft orbit, are a function of the spacecraft trajectory and attitude errors. Therefore, these errors are used to estimate both trajec- tory and attitude. In addition, the time rate of change of the magnetic field vector is used to estimate the spacecraft rotation rate. The estimation of the attitude and tra- jectory is augmented with the rate estimation into an Extended Kalman filter blended with a pseudc-linear Kalman filter. Sun sensor data is also used to improve the accu- racy and observability of the attitude and rate estimates. This test serves to validate MAGNAV as a single low cost navigation system which utilizes reliable, flight qualified sensors. MAGNAV is intended as a backup algorithm, an initialization algorithm, or possibly a prime navigation algorithm for a mission with coarse constraints.

Thienel, Julie↗

High temperature static strain gage development

Final results are presented from a program to develop a thin film static strain gage for use on the blades and vanes of running, test stand gas turbine engines with goals of an 3 x 3 mm gage area and total errors of less than 10 pct. of + or - 2,000 microstrain after 50 hrs at 1250 K. Pd containing 13 Wt. pct. Cr was previously identified as a new strain sensor alloy that appeared to be potentially usable to 1250 K. Subsequently, it was discovered, in contrast with its behavior in bulk, that Pd-13Cr suffered from oxidation attack when prepared as a 4.5 micron thick thin film. Continuing problems with electrical leakage to the substrate and the inability of sputtered alumina overcoats to prevent oxidation led to the discovery that sputtered alumina contains appreciable amounts of entrapped argon. After the argon has been exsolved by heating to elevated temperatures, the alumina films undergo a linear shrinkage of about 2 pct. resulting in formation of cracks. These problems can be largely overcome by sputtering the alumina with the substrate heated to 870 K. With 2 micron thick hot sputtered alumina insulation and overcoat films, total 50 hr drifts of about 100 microstrain (2 tests) and about 500 microstrain (1 test) were observed at 1000 and 1100 K, respectively. Results of tests on complete strain gage systems on constant moment bend bars with Pd temperature compensation grids revealed that oxidation of the Pd grid was a major problem even when the grid was overcoated with a hot or cold sputtered alumina overcoat.

Hulse, C. O.↗

New near-infrared period–luminosity–metallicity relations for RR Lyrae stars and the outlook for GAIA

We present results of the analysis of 70 RR Lyrae stars located in the bar of the Large Magellanic Cloud (LMC). Combining the spectroscopically determined metallicity of these stars from the literature with precise periods from the OGLE III catalog and multi-epoch K{sub s} photometry from the VISTA survey of the Magellanic Clouds system, we derive a new near-infrared period–luminosity–metallicity (PL{sub K{sub s}}Z) relation for RR Lyrae variables. In order to fit the relation we use a fitting method developed specifically for this study. The zero-point of the relation is estimated two different ways: by assuming the value of the distance to the LMC and by using Hubble Space Telescope parallaxes of five RR Lyrae stars in the Milky Way (MW). The difference in distance moduli derived by applying these two approaches is ∼0.2 mag. To investigate this point further we derive the PL{sub K{sub s}}Z relation based on 23 MW RR Lyrae stars that had been analyzed in Baade–Wesselink studies. We compared the derived PL{sub K{sub s}}Z relations for RR Lyrae stars in the MW and LMC. Slopes and zero-points are different, but still consistent within the errors. The shallow slope of the metallicity term is confirmed by both LMC and MW variables. The astrometric space mission Gaia is expected to provide a huge contribution to the determination of the RR Lyrae PL{sub K{sub s}}Z relation; however, calculating an absolute magnitude from the trigonometric parallax of each star and fitting a PL{sub K{sub s}}Z relation directly to period and absolute magnitude leads to biased results. We present a tool to achieve an unbiased solution by modeling the data and inferring the slope and zero-point of the relation via statistical methods.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of branching fractions of B decays to K 1 (1270)π and K 1 (1400)π and determination of the CKM angle α from B 0 → a 1 (1260) ± π ∓

In the Standard Model, CP violation in weak interactions involving quarks is parameterized by an irreducible complex phase in the Cabibbo-Kobayashi-Maskawa (CKM) quark-mixing-matrix. The precise determination of the CKM elements is a necessary ingredient for a stringent test of the Standard Model predictions, and is a crucial input for reducing the theoretical error in many New Physics searches with flavor, e.g., in the kaon sector. The unitarity of the CKM matrix is typically expressed as a triangle relationship among its parameters, where the area of the so-called Unitarity Triangle visually depicts the amount of asymmetry between the decays of B particles and their antimatter counterparts. In the past few years, the BABAR and Belle experiments have been able to measure all three angles of the triangle from CP asymmetry measurements. The first asymmetry measurements in B particle decays, about ten years ago, allowed to determine β, which is now known to better than 5% precision. The angles α and γ, measured in much rarer processes, required several years of data taking before analyses could yield reliable answers. A remarkable feature is that the direct measurement of the angles of the Unitarity Triangle generates an area that is consistent with the area predicted by measurement of the sides. In this thesis we have presented the branching fraction measurements of charged and neutral B meson decays to K 1 (1270)π and K 1 (1400)π, obtained from a data sample of 454 million Υ(4S) → B$\bar{B}$ events. This analysis is particularly challenging from the experimental side since the branching fractions involved are very low, at the level of 10 -6 - 10 -7 , and the signal is characterized by the simultaneous presence of two overlapping resonances, which exhibit sizeable interference effects. The combined K 1 (1270)π and K 1 (1400)π signal is therefore modeled with a K-matrix formalism, which accounts for the effects of interference between the K 1 (1270) and K 1 (1400) mesons by introducing two effective parameters. The model is derived from the analysis, performed by the ACCMOR Collaboration, of the diffractive production of strange mesons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved Modeling in a Matlab-Based Navigation System

An innovative approach to autonomous navigation is available for low earth orbit satellites. The system is developed in Matlab and utilizes an Extended Kalman Filter (EKF) to estimate the attitude and trajectory based on spacecraft magnetometer and gyro data. Preliminary tests of the system with real spacecraft data from the Rossi X-Ray Timing Explorer Satellite (RXTE) indicate the existence of unmodeled errors in the magnetometer data. Incorporating into the EKF a statistical model that describes the colored component of the effective measurement of the magnetic field vector could improve the accuracy of the trajectory and attitude estimates and also improve the convergence time. This model is identified as a first order Markov process. With the addition of the model, the EKF attempts to identify the non-white components of the noise allowing for more accurate estimation of the original state vector, i.e. the orbital elements and the attitude. Working in Matlab allows for easy incorporation of new models into the EKF and the resulting navigation system is generic and can easily be applied to future missions resulting in an alternative in onboard or ground-based navigation.

Deutschmann, Julie↗

Results of the Magnetometer Navigation (MAGNAV)lnflight Experiment

The Magnetometer Navigation (MAGNAV) algorithm is currently running as a flight experiment as part of the Wide Field Infrared Explorer (WIRE) Post-Science Engineering Testbed. Initialization of MAGNAV occurred on September 4, 2003. MAGNAV is designed to autonomously estimate the spacecraft orbit, attitude, and rate using magnetometer and sun sensor data. Since the Earth's magnetic field is a function of time and position, and since time is known quite precisely, the differences between the computed magnetic field and measured magnetic field components, as measured by the magnetometer throughout the entire spacecraft orbit, are a function of the spacecraft trajectory and attitude errors. Therefore, these errors are used to estimate both trajectory and attitude. In addition, the time rate of change of the magnetic field vector is used to estimate the spacecraft rotation rate. The estimation of the attitude and trajectory is augmented with the rate estimation into an Extended Kalman filter blended with a pseudo-linear Kalman filter. Sun sensor data is also used to improve the accuracy and observability of the attitude and rate estimates. This test serves to validate MAGNAV as a single low cost navigation system which utilizes reliable, flight qualified sensors. MAGNAV is intended as a backup algorithm, an initialization algorithm, or possibly a prime navigation algorithm for a mission with coarse requirements. Results from the first six months of operation are presented.

Thienel, Julie K.↗