Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “environmental contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Chemical Aging of Environmentally Friendly Cleaners

Use of cleaners in the manufacturing area demands bottles that will hold a sufficient amount of material and allow for easy and controlled dispensing by the operator without contamination or material leaching from the bottle. The manufacturing storage conditions are also a factor that may affect cleaner chemical integrity and its potential to leave a residue on the part. A variety of squeeze bottles stored in mild (72 F, 10 % R.H., dark) and harsh (105 F, 50 % R.H., fluorescent lighting) conditions were evaluated to determine the effect of environment and bottle exposure on the chemical composition of TCA (1,1,1 trichloroethane) replacement solvents. Low Density Polyethylene (LDPE) bottles were found to be quite permeable to all the cleaners evaluated in this study indicating this bottle type should not be used in the manufacturing area. Fluorinated Polyethylene (FLPE) bottles showed little cleaner loss and change in cleaner chemical composition over time suggesting these bottles would be acceptable for use. Chemical analysis indicates limonene-containing cleaners show increased non-volatile residue (NVR) content with storage under harsh conditions. Some cleaners use BHT (butylated hydroxytoluene) as stabilizer and to protect against limonene oxidation. Under harsh conditions, BHT was quickly depleted resulting in higher NVR levels.

Evans, K.↗

US EPA Superfund Remediation Program Update: Revisions to Risk and Dose Assessment Models - 20368

The U.S. Environmental Protection Agency (EPA) Superfund remedial program is finishing up a significant number of revisions to its guidance for the risk assessment process at radioactively contaminated Superfund sites. The six Preliminary Remediation Goal (PRG) and Dose Compliance Concentration (DCC) internet-based calculators for radiation risk and dose assessment at Superfund sites are being reformatted to match the chemical calculators and improve the user experience, revised to add a new peak risk and dose output option, and to add some adjustment options for external exposure. A new Radon Vapor Intrusion Screening Level (RVISL) calculator is expected to be finished in 2020, will be similar to the Vapor Intrusion Screening Level (VISL) for chemical calculator that was finished in 2018. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Genomic reconstruction of Bacillus anthracis from complex environmental samples enables high-throughput identification and lineage assignment in Pakistan

Bacillus anthracis, the causative agent of anthrax, is a highly virulent zoonotic pathogen primarily affecting domesticated and wild herbivores. Human exposure to B. anthracis is primarily through contact with infected animals or contaminated animal products. In Pakistan, where livestock vaccines are largely unavailable and infected carcasses are often disposed of improperly, the risk to humans, wildlife and livestock is significant. Currently, the diagnosis of anthrax infections and outbreak tracing necessitates the isolation and culturing of B. anthracis, a process that requires BSL-3 facilities. In this study, we show that positive identification, genome reconstruction and lineage assignment can be accomplished using bioinformatic analysis of DNA extracted directly from environmental samples that would otherwise provide the starting material for isolation and culturing. This approach does not require laboratory target enrichment as is necessary for other pathogens, due in part to the extremely high bacterial load in the bloodstream in the deceased animals. Using these methods, we greatly expand the knowledge of endemic B. anthracis in Pakistan. We provide the first reference B. anthracis genomes from Pakistan since the 1970s and identify A.Br.014 Aust94 as a minor circulating sublineage alongside the dominant A.Br.047 Vollum. Future work will focus on the limits of detection and will determine if this bioinformatic method can be expanded more broadly for B. anthracis or other pathogens to replace typical culture-based methods.

A.Br.047 Vollum↗

The space station - An overview of the design process

The design factors being considered in the NASA space-station development program are summarized. The currently envisioned mission requirements are listed, and the system architecture is defined as a core station, mission-dedicated elements, and supporting equipment such as an orbit maneuvering vehicle. System design factors discussed include orbit selection, contamination control, autonomy, system safety, technology implementation, long life, reliability and maintainability, and cost; subsystem design factors include structural considerations, electrical power, environmental control and life support, data management, communications and tracking, onboard propulsion, habitability, and crew support. Configurational design is seen as driven by a number of factors, primarily the need to fit all components into the Shuttle payload bay for assembly in LEO by the Shuttle crew.

Covington, C.↗

Alternative Green Solvents Project

Necessary for safe and proper functioning of equipment. Mainly halogenated solvents. Tetrachloride, Trichloroethylene (TCE), CFC-113. No longer used due to regulatory/safety concerns. Precision Cleaning at KSC: Small % of total parts. Used for liquid oxygen (LOX) systems. Dual solvent process. Vertrel MCA (decafluoropentane (DFP) and trons-dichloroethylene) HFE-7100. DFP has long term environmental concerns. Project Goals: a) Identify potential replacements. b) 22 wet chemical processes. c) 3 alternative processes. d) Develop test procedures. e) Contamination and cleaning. f) Analysis. g) Use results to recommend alternative processes. Conclusions: a) No alternative matched Vertrel in this study. b) No clear second place solvent. c) Hydrocarbons- easy; Fluorinated greases- difficult. d) Fluorinated component may be needed in replacement solvent. e) Process may need to make up for shortcoming of the solvent. f) Plasma and SCC02 warrant further testing.

Maloney, Phillip R.↗

Hybrid Sorbents for 129 I Capture from Contaminated Groundwater

Radioiodine ( 129 I) poses a risk to the environment due to its long half-life, toxicity, and mobility. It is found at the U.S. Department of Energy Hanford Site due to legacy releases of nuclear wastes to the subsurface where 129 I is predominantly present as iodate (IO 3 – ). To date, a cost-effective and scalable cleanup technology for 129 I has not been identified, with hydraulic containment implemented as the remedial approach. Here, novel high-performing sorbents for 129 I remediation with the capacity to reduce 129 I concentrations to or below the US Environmental Protection Agency (EPA) drinking water standard and procedures to deploy them in an ex-situ pump and treat (P&T) system are introduced. Furthermore, this includes implementation of hybridized polyacrylonitrile (PAN) beads for ex-situ remediation of IO 3 – -contaminated groundwater for the first time. Iron (Fe) oxyhydroxide and bismuth (Bi) oxyhydroxide sorbents were deployed on silica substrates or encapsulated in porous PAN beads. In addition, Fe–, cerium (Ce)–, and Bi–oxyhydroxides were encapsulated with anion-exchange resins. The PAN–bismuth oxyhydroxide and PAN–ferrihydrite composites along with Fe- and Ce-based hybrid anion-exchange resins performed well in batch sorption experiments with distribution coefficients for IO 3 – of >1000 mL/g and rapid removal kinetics. Of the tested materials, the Ce-based hybrid anion-exchange resin was the most efficient for removal of IO 3 – from Hanford groundwater in a column system, with 50% breakthrough occurring at 324 pore volumes. The functional amine groups on the parent resin and amount of active sorbent in the resin can be customized to improve the iodine loading capacity. These results highlight the potential for IO 3 – remediation by hybrid sorbents and represent a benchmark for the implementation of commercially available materials to meet EPA standards for cleanup of 129 I in a large-scale P&T system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Source Contaminant Control System Design, Operation, and Testing for the Trash Compaction and Processing System

The Trash Compaction and Processing System (TCPS) aims to reduce volume, biologically safen, physically stabilize, manage effluents, and recover resources from astronaut trash in the International Space Station (ISS). This process involves heating the trash to high temperatures, which in turn releases gaseous contaminants. Effluent management scenarios involve releasing these gases back to the ISS cabin after processing and/or directly venting these gases out to space via the Vacuum Exhaust System (VES). Concerns for recovering the gases back to cabin are crew health, safety, and spacecraft environmental impact. The Heat Melt Compactor (HMC) at NASA Ames Research Center (ARC) serves as a test system that supports TCPS development by conducting risk reduction activities associated with an ISS flight demonstration. Previous gas effluent studies were conducted on the HMC. The results consisted of contaminants from the trash exhaust to exceed Spacecraft Maximum Allowable Concentrations (SMAC), which are selected airborne contaminants that can elicit toxicity symptoms to crewmembers via exposure. The Source Contaminant Control System (SCCS) aims to reduce that risk by converting the contaminants into carbon dioxide (CO2) and water (H2O) vapor. The SCCS is composed of a carbon adsorbent bed, to avoid catalyst poisoning, and a catalytic oxidizer (CatOx), which promotes oxidation of the contaminants to CO2 and H2O. In turn, the gases coming out of the SCCS should be compatible to the ISS cabin and systems such as the Trace Contaminant Control System (TCCS). Preparation for SCCS testing alongside the HMC Gen 3 are currently underway at ARC. The main objectives are to evaluate CatOx efficiency by CO2 conversion and characterize effectiveness of removal by comparing contaminant results before and after CatOx. This paper will report on the SCCS design, operation, and testing with results.

Janine Young↗

Source Contaminant Control System Design, Operation, and Testing for the Trash Compaction and Processing System

The Trash Compaction and Processing System (TCPS) aims to reduce volume, biologically safen, physically stabilize, manage effluents, and recover resources from astronaut trash in the International Space Station (ISS). This process involves heating the trash to high temperatures, which in turn releases gaseous contaminants. Effluent management scenarios involve releasing these gases back to the ISS cabin after processing and/or directly venting these gases out to space via the Vacuum Exhaust System (VES). Concerns for recovering the gases back to cabin are crew health, safety, and spacecraft environmental impact. The Heat Melt Compactor (HMC) at NASA Ames Research Center (ARC) serves as a test system that supports TCPS development by conducting risk reduction activities associated with an ISS flight demonstration. Previous gas effluent studies were conducted on the HMC. The results consisted of contaminants from the trash exhaust to exceed Spacecraft Maximum Allowable Concentrations (SMAC), which are selected airborne contaminants that can elicit toxicity symptoms to crewmembers via exposure. The Source Contaminant Control System (SCCS) aims to reduce that risk by converting the contaminants into carbon dioxide (CO2) and water (H2O) vapor. The SCCS is composed of a carbon adsorbent bed, to avoid catalyst poisoning, and a catalytic oxidizer (CatOx), which promotes oxidation of the contaminants to CO2and H2O. In turn, the gases coming out of the SCCS should be compatible to the ISS cabin and systems such as the Trace Contaminant Control System (TCCS). Preparation for SCCS testing alongside the HMC Gen 3 are currently underway at ARC. The main objectives are to evaluate CatOx efficiency by CO2conversion and characterize effectiveness of removal by comparing contaminant results before and after CatOx. This paper will report on the SCCS design, operation, and testing with results.

TCPS↗

NASA Technology Evaluation for Environmental Risk Mitigation Remediation Technology Collaboration Development

NASA is committed to finding solutions to agency cleanup problems that are better, cheaper, and more effective than the status quo. Unfortunately, some potential solutions involve innovative technologies for which NASA remediation managers may not have a high level of understanding or confidence. Since 2004, NASA's Stennis Space Center (SSC) in Mississippi has been pumping groundwater contaminated with trichloroethylene (TCE) and other halogenated volatile organic compounds (HVOC) from their cleanup location designated "Area G" through extraction wells to an aboveground treatment system. Over time, however, the effectiveness of this treatment strategy has diminished and an alternative approach is needed. In 2012, professionals from NASA's Principal Center for Technology Evaluation for Environmental Risk Mitigation (TEERM) introduced SSC managers to an innovative technology for enhancing the performance of SSC's existing pump and treat system. The technology, generally referred to as in situ chemical oxidation (ISCO), involves slowly and continuously injecting a strong but safe chemical oxidant into the groundwater. Treatment is enhanced by a "surfactant-type effect" which causes residual contamination from saturated soil to be released into the dissolved-phase where it can be readily oxidized. Any dissolved-phase contamination that was not oxidized can be collected by the extraction well network and treated aboveground. SSC was not familiar with the technology so to increase their confidence, TEERM identified a contractor who was willing to demonstrate their product and process at a significantly reduced price. An initial, small-scale demonstration of ISCO began at sse in March 2012 and completed in August 2012. This successful demonstration was followed by three larger-scale ISCO demonstrations between August and December 2012. The contractor's innovative Continuous Injection System (CIS) incorporated "green" and sustainable technologies and practices. A slow injection rate was maintained autonomously by the CIS, eliminating the need for multiple mobilizations of personnel and powered equipment. The CIS was calibrated to deliver only as much reagent as the formation would accept without "short circuiting", minimizing material waste. Public utility water pressure was used to mix, dilute, and inject the reagent. NASA personnel were trained to operate and maintain the system and remote monitoring and injection control capabilities were developed, further reducing the need for contractor mobilizations to the site. An integrated solar photovoltaic panel was used to power the control valves and web monitoring telemetry. SSC provided hydrogen peroxide for the process using their existing supplier for the aboveground pump and treat systems. The only consumable required from the contractor was their proprietary activator to catalyze SSC's peroxide.

Romeo, James↗

The effects of environmental exposure on reusable surface insulation for space shuttle

Coated specimens of reusable surface insulation (RSI) were exposed to alternate radiant heating and atmospheric exposure cycles to study the effects of surface contamination on the RSI coating. Different methods of heating were employed on clean and artificially contaminated specimens to determine the contributions of heating conditions to coating devitrification.

Ransone, P. O.↗

Space Station atmospheric monitoring systems

A technology assessment study on atmospheric monitoring systems was performed by Battelle Columbus Division for the National Aeronautics and Space Administration's John F. Kennedy Space Center under Contract No. NAS 10-11033. In this assessment, the objective was to identify, analyze, and recommend systems to sample and measure Space Station atmospheric contaminants and identify where additional research and technology advancements were required. To achieve this objective, it was necessary to define atmospheric monitoring requirements and to assess the state of the art and advanced technology and systems for technical and operational compatibility with monitoring goals. Three technical tasks were defined to support these needs: Definition of Monitoring Requirements, Assessment of Sampling and Analytical Technology, and Technology Screening and Recommendations. Based on the analysis, the principal candidates recommended for development at the Space Station's initial operational capability were: (1) long-path Fourier transform infrared for rapid detection of high-risk contamination incidences, and (2) gas chromatography/mass spectrometry utilizing mass selective detection (or ion-trap) technologies for detailed monitoring of extended crew exposure to low level (ppbv) contamination. The development of a gas chromatography/mass spectrometry/matrix isolation-Fourier transform infrared system was recommended as part of the long range program of upgrading Space Station trace-contaminant monitoring needs.

Air Pollution, Indoor/analysis↗

Policy-Driven Sustainable Saline Drainage Disposal and Forage Production in the Western San Joaquin Valley of California

Environmental policies to address water quality impairments in the San Joaquin River of California have focused on the reduction of salinity and selenium-contaminated subsurface agricultural drainage loads from westside sources. On 31 December 2019, all of the agricultural drainage from a 44,000 ha subarea on the western side of the San Joaquin River basin was curtailed. This policy requires the on-site disposal of all of the agricultural drainage water in perpetuity, except during flooding events, when emergency drainage to the River is sanctioned. The reuse of this saline agricultural drainage water to irrigate forage crops, such as ‘Jose’ tall wheatgrass and alfalfa, in a 2428 ha reuse facility provides an economic return on this pollutant disposal option. Irrigation with brackish water requires careful management to prevent salt accumulation in the crop root zone, which can impact forage yields. The objective of this study was to optimize the sustainability of this reuse facility by maximizing the evaporation potential while achieving cost recovery. This was achieved by assessing the spatial and temporal distribution of the root zone salinity in selected fields of ‘Jose’ tall wheatgrass and alfalfa in the drainage reuse facility, some of which have been irrigated with brackish subsurface drainage water for over fifteen years. Electromagnetic soil surveys using an EM-38 instrument were used to measure the spatial variability of the salinity in the soil profile. The tall wheatgrass fields were irrigated with higher salinity water (1.2–9.3 dS m -1 ) compared to the fields of alfalfa (0.5–6.5 dS m -1 ). Correspondingly, the soil salinity in the tall wheatgrass fields was higher (12.5 dS m -1 –19.3 dS m -1 ) compared to the alfalfa fields (8.97 dS mm -1 –14.4 dS mm -1 ) for the years 2016 and 2017. Better leaching of salts was observed in the fields with a subsurface drainage system installed (13–1 and 13–2). The depth-averaged root zone salinity data sets are being used for the calibration of the transient hydro-salinity computer model CSUID-ID (a one-dimensional version of the Colorado State University Irrigation Drainage Model). This user-friendly decision support tool currently provides a useful framework for the data collection needed to make credible, field-scale salinity budgets. In time, it will provide guidance for appropriate leaching requirements and potential blending decisions for sustainable forage production. This paper shows the tie between environmental drainage policy and the role of local governance in the development of sustainable irrigation practices, and how well-directed collaborative field research can guide future resource management.

54 ENVIRONMENTAL SCIENCES↗

Closure Report for Corrective Action Unit 116: Area 25 Test Cell C Facility, Nevada National Security Site, Nevada with ROTC-1

CR loaded to this OSTI record. Just adding new file which includes CR plus new ROTC 1 and update the metadata to the following: This Closure Report (CR) presents information supporting closure of Corrective Action Unit (CAU) 116, Area 25 Test Cell C Facility. This CR complies with the requirements of the Federal Facility Agreement and Consent Order (FFACO) that was agreed to by the State of Nevada; the U.S. Department of Energy (DOE), Environmental Management; the U.S. Department of Defense; and DOE, Legacy Management (FFACO, 1996 [as amended March 2010]). CAU 116 consists of the following two Corrective Action Sites (CASs), located in Area 25 of the Nevada National Security Site: (1) CAS 25-23-20, Nuclear Furnace Piping and (2) CAS 25-41-05, Test Cell C Facility. CAS 25-41-05 consisted of Building 3210 and the attached concrete shield wall. CAS 25-23-20 consisted of the nuclear furnace piping and tanks. Closure activities began in January 2007 and were completed in August 2011. Activities were conducted according to Revision 1 of the Streamlined Approach for Environmental Restoration Plan for CAU 116 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2008). This CR provides documentation supporting the completed corrective actions and provides data confirming that closure objectives for CAU 116 were met. Site characterization data and process knowledge indicated that surface areas were radiologically contaminated above release limits and that regulated and/or hazardous wastes were present in the facility. The Record of Technical Change 1 updated the use restriction information.

54 ENVIRONMENTAL SCIENCES↗

Hurricanes and turbulent floods threaten arsenic-contaminated coastal soils and vulnerable communities

Coastal environments, particularly those adjacent to Superfund sites, are at increased risk of contaminant release during natural disasters, posing serious threats to nearby communities. To investigate this issue, we employed an advanced laboratory flood simulator to impose arsenic-contaminated sediments to turbulent flooding events. We further monitored changes in arsenic collocation and solid-phase speciation using advanced synchrotron radiation-based techniques to understand the impacts of flooding on arsenic mobility. Our results demonstrate that turbulent conditions significantly enhance the resuspension of arsenic-rich sediments, resulting in increased arsenic release into the water. This mobilization is driven by the erosion of the reduced sediments and the redox-mediated transformation and dissolution of Fe and Mn (oxyhydr) oxides, which promote the release of As(III). We found that arsenic speciation on resuspended particles is closely tied to shear stress, with As(V) prevailing at low stress and the more toxic As(III) dominating at higher stress levels. In the post-erosion phase, solid-phase As(III) decreased while dissolved As(III) increased, indicating ongoing desorption. The persistence of multiple arsenic species on resuspended particles marks them as potential long-range transport vectors. Thus, the environmental impact of flooding and sediment resuspension extends beyond the event itself, raising longer-term concerns for arsenic mobility. Our comprehensive geospatial analysis revealed substantial overlap between arsenic-contaminated soils and regions at high risk of flooding and hurricanes across the conterminous United States. This overlap disproportionately impacts economically disadvantaged and marginalized communities. Approximately 40 million Americans reside within 10 kilometers of these high-risk contaminated zones, with nearly 28 million exposed to hurricane threats and around 18 million vulnerable to flooding risks. Alarmingly, over 40% of those affected by hurricanes and 33% of those impacted by flooding belong to underrepresented minority and low-income populations. These findings highlight the urgent need for targeted mitigation strategies to protect public health and address environmental justice concerns.

54 ENVIRONMENTAL SCIENCES↗

Impacts of divalent cations (Mg 2+ and Ca 2+ ) on PFAS bioaccumulation in freshwater macroinvertebrates representing different foraging modes

Per- and polyfluoroalkyl substances (PFAS) have extensively contaminated freshwater aquatic ecosystems where they can be transported in water and partition to sediment and biota. In this paper, three freshwater benthic macroinvertebrates with different foraging modes were exposed to environmentally relevant concentrations of eight perfluoroalkyl carboxylates (PFCA), three perfluoroalkyl sulfonates (PFSA), and three fluorotelomer sulfonates (FTS) at varying divalent cation concentrations of magnesium (Mg 2+ ) and calcium (Ca 2+ ). Divalent cations can impact PFAS partitioning to solids, especially to sediments, at higher concentrations. Sediment dwelling worms (Lumbriculus variegatus), epibenthic grazing snails (Physella acuta), and sediment-dwelling filter-feeding bivalves (Elliptio complanata) were selected due to their unique foraging modes. Microcosms were composed of synthetic sediment, culture water, macroinvertebrates, and PFAS and consisted of a 28-day exposure period. L. variegatus had significantly higher PFAS bioaccumulation than P. acuta and E. complanata, likely due to higher levels of interactions with and ingestion of the contaminated sediment. “High Mg 2+ ” (7.5 mM Mg 2+ ) and “High Ca 2+ ” (7.5 mM Ca 2+ ) conditions generally had statistically higher bioaccumulation factors (BAF) than the “Reference Condition” (0.2 mM Ca 2+ and 0.2 mM Mg 2+ ) for PFAS with perfluorinated chain lengths greater than eight carbons. Long-chain PFAS dominated the PFAS profiles of the macroinvertebrates for all groups of compounds studied (PFCA, PFSA, and FTS). Furthermore, these results indicate that the study organism has the greatest impact on bioaccumulation, although divalent cation concentration had observable impacts between organisms depending on the environmental conditions. Elevated cation concentrations in the microcosms led to significantly greater bioaccumulation in the test organisms compared to the experimental reference conditions for long-chain PFAS.

54 ENVIRONMENTAL SCIENCES↗

Application of a Null-Space Monte Carlo Flow Model Set to the Composite Analysis Base Case Fate and Transport Modeling

The Plateau to River Groundwater Model (P2R Model) is a groundwater flow and contaminant fate and transport (F&T) simulation model used to support remedial activities conducted by CH2M HILL Plateau Remediation Company at the Hanford Site in Washington State. Figure 1-1 illustrates the P2R Model extents, discretization, and boundary conditions. The P2R Model is utilized in the Composite Analysis (CA) for the Hanford Site as the computational engine for computing F&T predictions as described in CP-60406, Hanford Site Composite Analysis Technical Approach Description: Groundwater. The model simulates contaminants of concern within the saturated zone of the uppermost aquifer beneath the Central Plateau and downgradient to the Columbia River. CP-57037, Model Package Report for the Plateau to River Model Version 8.3, documents the current version of the P2R Model including a description of the conceptual site model, model development and calibration, and limitations to the model application. The overall objective of the saturated zone modeling effort is to provide a basis for making informed remedial action decisions based on descriptions of current and expected future contaminant concentrations in groundwater at decision points within and downgradient of the Central Plateau of the Hanford Site. Specifically, the purpose of this environmental calculation is to describe the application of the hydraulic property fields and recharge parameters documented in ECF-HANFORD-20-0027, Null Space Monte Carlo Evaluation of the Plateau to River Model, to the CA flow and fate and transport simulation results to quantify the uncertainty in the simulated results due to input parameter selection. Use of numerical groundwater models is always accompanied with uncertainty in the results produced by a model because models are approximations of reality. Thus, by definition, models lack the detail to fully represent observed behavior. Use of numerical techniques, such as a NSMC analysis, can help in identifying and quantifying the potential uncertainties associated with a numerical model such as the P2R Model. The result of NSCM analysis is a set of F&T simulations that provide an estimate of the range of possible outcomes that are used to quantify the uncertainty in simulated concentrations produced using the base case simulations. The simulated concentrations from all simulations will support calculation of the uncertainty of the total dose calculated in a separate calculation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Review of Carbon-14 Removal by Ion Exchange Resins and Potential Remediation Application in the 100-K Area

During operations at the U.S. Department of Energy Hanford Site, releases of chemical and radioactive waste resulted in contamination of the soil and groundwater beneath portions of the site, including inadvertent releases of carbon-14 in the 100-K Area. Ongoing environmental cleanup efforts in the 100-K Area are focused on hexavalent chromium [Cr(VI)] and thus have not yet addressed the two carbon-14 groundwater plumes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗