Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “enclosure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Development of a new rectangular NaI(Tl) scintillator and spectroscopy of low-energy charged particles

Standard NaI(Tl) scintillators have only one optical window and are housed in airtight protective enclosures to protect against hygroscopicity from moisture in the air. For these reasons, NaI(Tl) scintillators are unsuitable for the collection of scintillation photons or for the detection of low-energy (<1 MeV) charged particles. To overcome these disadvantages, a rectangular NaI(Tl) scintillator has been newly developed. In this paper, we estimate the photon response of this new scintillator. The energy resolution was {Delta}E (Full Width at Half Maximum)=7.5{+-}0.2% for 662 keV gamma rays from a {sup 137}Cs standard source. The number of photoelectrons was 3,686 for the photoelectric peak. Good energy resolution and photon collection were therefore confirmed for this specialized form of NaI(Tl) scintillator. The ability of this scintillator to detect low-energy particles was confirmed by successful measurement of low-energy charged particles (250-700 keV region) from a {sup 137}Cs thin film radioisotope source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Commissioning Of A Three Dimensional Depolarized Neutron Beamline For Studying The Magnetic Correlation Length Of A Magnetic Material At Tsing Hua Open-Pool Reactor

A new three dimensional neutron depolarization beamline was commissioning at W3 beam port of Tsing Hua Open Pool Reactor (THOR, 2 MW) located in Hsinchu, Taiwan. The beamline consists of a pair of Heusler crystals as neutron polarizer and analyzer. Two three-dimensional rotators were placed before and after the sample position. The sample chamber was enclosed in a mu-metal enclosure with a gradient field at incident and exit ports. Typically, 0.237 nm of monoenergetic neutron was selected for experiments. A flipping ratio of 23 can be obtained which corresponds to a polarization ratio of 92% of this beamline. The typical intensity is 400 n/cm{sup 2}s at 1 MW operation. Magnetic correlation lengths of Ni-ferrite powders with different packing densities were measured to understand the characteristics of this beamline. The magnetic correlation lengths were observed to be 2 mum at virgin state and about 3.1 mum at remanent state. This magnetic correlation length in the virgin state is similar than the particle size. No significant change of domain size at packing density up to 60% implies that the domain wall motion is hindered by the porosity of the sample.

36 MATERIALS SCIENCE↗

Thermosolutal Convection in a Shallow Layer of a Binary Fluid

This paper reports an analytical and numerical study of the combined Soret and thermosolutal effects on natural convection in a shallow rectangular cavity filled with a binary mixture. Neumann boundary conditions for temperature and concentration are applied to the horizontal walls of the enclosure, while the two vertical ones are assumed impermeable and insulated. For convection in an infinite layer, analytical solutions for the stream function, temperature and concentration fields are obtained using a parallel flow approximation in the core region of the cavity and an integral form of the energy and constituent equations. The critical Rayleigh numbers for the onset of supercritical and subcritical convection are predicted explicitly by the present model. Numerical solutions of the full governing equations are obtained for a wide range of the governing parameters. A good agreement is observed between the analytical model and the numerical simulations.

36 MATERIALS SCIENCE↗

Asymmetrically cut crystal pair as x-ray magnifier for imaging at high intensity laser facilities

The potential of an x-ray magnifier prepared from a pair of asymmetrically cut crystals is studied to explore high energy x-ray imaging capabilities at high intensity laser facilities. OMEGA-EP and NIF when irradiating mid and high Z targets can be a source of high-energy x-rays whose production mechanisms and use as backlighters are a subject of active research. This paper studies the properties and potential of existing asymmetric cut crystal pairs from the National Institute of Standards and Technology (NIST) built in a new enclosure for imaging x-ray sources. The technique of the x-ray magnifier has been described previously. This new approach is aimed to find a design that could be used at laser facilities by magnifying the x-ray source into a screen far away from the target chamber center, with fixed magnification defined by the crystals' lattice spacing and the asymmetry angles. The magnified image is monochromatic and the imaging wavelength is set by crystal asymmetry and incidence angles. First laboratory results are presented and discussed.

36 MATERIALS SCIENCE↗

A thermal porosimetry method to estimate pore size distribution in highly porous insulating materials

Standard pore size determination methods such as mercury porosimetry, nitrogen sorption, microscopy, or x-ray tomography are not always applicable to highly porous, low density, and thus very fragile materials. For this kind of materials, a method based on thermal characterization is proposed. Indeed, the thermal conductivity of a highly porous and insulating medium is significantly dependent on the thermal conductivity of the interstitial gas that depends on both gas pressure and size of the considered pore (Knudsen effect). It is also possible to link the pore size with the thermal conductivity of the medium. Thermal conductivity measurements are realized on specimens placed in an enclosure where the air pressure is successively set to different values varying from 10{sup -1} to 10{sup 5} Pa. Knowing the global porosity ratio, an effective thermal conductivity model for a two-phase air-solid material based on a combined serial-parallel model is established. Pore size distribution can be identified by minimizing the sum of the quadratic differences between measured values and modeled ones. The results of the estimation process are the volume fractions of the chosen ranges of pore size. In order to validate the method, measurements done on insulating materials are presented. The results are discussed and show that pore size distribution estimated by the proposed method is coherent.

36 MATERIALS SCIENCE↗

An oscillator circuit to produce a radio-frequency discharge and application to metastable helium saturated absorption spectroscopy

We present a rf gas discharge apparatus which provides an atomic frequency reference for laser manipulation of metastable helium. We discuss the biasing and operation of a Colpitts oscillator in which the discharge coil is part of the oscillator circuit. Radiofrequency radiation is reduced by placing the entire oscillator in a metal enclosure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modular instrument mounting system for variable environment in operando X-ray experiments

In the growing field of in operando and in situ X-ray experiments, there exists a large disparity in the types of environments and equipment to control them. This situation makes it challenging to conduct multiple experiments with a single mechanical interface to the diffractometer. Here, we describe the design and implementation of a modular instrument mounting system that can be installed on a standard six-circle diffractometer (e.g., 5021 Huber GmbH). This new system allows for the rapid changeover of different chambers and sample heaters and permits accurate sample positioning (x, y, z, and azimuthal rotation) without rigid coupling to the chamber body. Isolation of the sample motion from the chamber enclosure is accomplished through a combination of custom rotary seals and bellows. Control of the pressure and temperature has been demonstrated in the ranges of 10{sup -6}-10{sup 3} Torr and 25 Degree-Sign C-900 Degree-Sign C, respectively. We have utilized the system with several different modular instruments. As an example, we provide in situ sputtering results, where the growth dynamics of epitaxial LaGaO{sub 3} thin films on (001) SrTiO{sub 3} substrates were investigated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization and performance of a field aligned ion cyclotron range of frequency antenna in Alcator C-Mod

Ion cyclotron range of frequency (ICRF) heating is expected to provide auxiliary heating for ITER and future fusion reactors where high Z metallic plasma facing components (PFCs) are being considered. Impurity contamination linked to ICRF antenna operation remains a major challenge particularly for devices with high Z metallic PFCs. Here, we report on an experimental investigation to test whether a field aligned (FA) antenna can reduce impurity contamination and impurity sources. We compare the modification of the scrape of layer (SOL) plasma potential of the FA antenna to a conventional, toroidally aligned (TA) antenna, in order to explore the underlying physics governing impurity contamination linked to ICRF heating. The FA antenna is a 4-strap ICRF antenna where the current straps and antenna enclosure sides are perpendicular to the total magnetic field while the Faraday screen rods are parallel to the total magnetic field. In principle, alignment with respect to the total magnetic field minimizes integrated E|| (electric field along a magnetic field line) via symmetry. A finite element method RF antenna model coupled to a cold plasma model verifies that the integrated E|| should be reduced for all antenna phases. Monopole phasing in particular is expected to have the lowest integrated E||. Consistent with expectations, we observed that the impurity contamination and impurity source at the FA antenna are reduced compared to the TA antenna. In both L and H-mode discharges, the radiated power is 20%–30% lower for a FA-antenna heated discharge than a discharge heated with the TA-antennas. However, inconsistent with expectations, we observe RF induced plasma potentials (via gas-puff imaging and emissive probes to be nearly identical for FA and TA antennas when operated in dipole phasing). Moreover, the highest levels of RF-induced plasma potentials are observed using monopole phasing with the FA antenna. Thus, while impurity contamination and sources are indeed reduced with the FA antenna configuration, the mechanism determining the SOL plasma potential in the presence of ICRF and its impact on impurity contamination and sources remains to be understood.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Graphlocons: Large dendritic graphene crystals and their electronic properties

Submillimeter dendritic-shaped crystals were synthesized by low pressure vapor chemical vapor deposition inside a copper enclosure. With their sixfold symmetry and fractal-like shape, the resulting crystals resemble snowflakes. The electronic properties of the devices were investigated down to sub-Kelvin temperatures, showing mobilities over 5000 cm{sup 2}/Vs and the quantum Hall effect at 8T. The magnetoresistance also displayed a sharp peak at zero field which we attribute to weak localization.

36 MATERIALS SCIENCE↗

Ionization energy shift of characteristic K x-ray lines from high-Z materials for plasma diagnostics

The energy of the characteristic x-rays emitted by high atomic number atoms in a plasma that contains energetic electrons depends on the atom's ionization. For tungsten, the ionization energy shift of the L-lines has recently been used to diagnose the plasma's ionization; the change in energy of a K-line has been measured for iridium and observed for ytterbium. Here, we present detailed computations of the ionization energy shift to K-lines of these and an additional element, dysprosium; for these atoms, some K-lines nearly coincide in energy with K-edges of slightly lower Z atoms so that a change in transmission behind a K-edge filter betrays a change in energy. The ionization energy shift of such high-energy K-lines may enable a unique diagnostic when the plasma is inside an otherwise opaque enclosure such as hohlraums used on the National Ignition Facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of a field-aligned ICRF antenna

Impurity contamination and localized heat loads associated with ion cyclotron range of frequency (ICRF) antenna operation are among the most challenging issues for ICRF utilization.. Another challenge is maintaining maximum coupled power through plasma variations including edge localized modes (ELMs) and confinement transitions. Here, we report on an experimental assessment of a field aligned (FA) antenna with respect to impurity contamination, impurity sources, RF enhanced heat flux and load tolerance. In addition, we compare the modification of the scrape of layer (SOL) plasma potential of the FA antenna to a conventional, toroidally aligned (TA) antenna, in order to explore the underlying physics governing impurity contamination linked to ICRF heating. The FA antenna is a 4-strap ICRF antenna where the current straps and antenna enclosure sides are perpendicular to and the Faraday screen rods are parallel to the total magnetic field. In principle, alignment with respect to the total magnetic field minimizes integrated E∥ (electric field along a magnetic field line) via symmetry. Consistent with expectations, we observed that the impurity contamination and impurity source at the FA antenna are reduced compared to the TA antenna. In both L and H-mode discharges, the radiated power is 20–30% lower for a FA-antenna heated discharge than a discharge heated with the TA-antennas. Further we observe that the fraction of RF energy deposited upon the antenna is less than 0.4 % of the total injected RF energy in dipole phasing. The total deposited energy increases significantly when the FA antenna is operated in monopole phasing. The FA antenna also exhibits an unexpected load tolerance for ELMs and confinement transitions compared to the TA antennas. However, inconsistent with expectations, we observe RF induced plasma potentials to be nearly identical for FA and TA antennas when operated in dipole phasing. In monopole phasing, the FA antenna has the highest plasma potentials and poor heating efficiency despite calculations indicating low integrated E∥. In mode conversion heating scenario, no core waves were detected in the plasma core indicating poor wave penetration. For monopole phasing, simulations suggest the antenna spectrum is peaked at very short wavelength and full wave simulations show the short wavelength has poor wave penetration to the plasma core.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical bandgap of ultra-thin amorphous silicon films deposited on crystalline silicon by PECVD

An optical study based on spectroscopic ellipsometry, performed on ultrathin hydrogenated amorphous silicon (a-Si:H) layers, is presented in this work. Ultrathin layers of intrinsic amorphous silicon have been deposited on n-type mono-crystalline silicon (c-Si) wafers by plasma enhanced chemical vapor deposition (PECVD). The layer thicknesses along with their optical properties –including their refractive index and optical loss- were characterized by spectroscopic ellipsometry (SE) in a wavelength range from 250 nm to 850 nm. The data was fitted to a Tauc-Lorentz optical model and the fitting parameters were extracted and used to compute the refractive index, extinction coefficient and optical bandgap. Furthermore, the a-Si:H film grown on silicon was etched at a controlled rate using a TMAH solution prepared at room temperature. The optical properties along with the Tauc-Lorentz fitting parameters were extracted from the model as the film thickness was reduced. The etch rate for ultrathin a-Si:H layers in TMAH at room temperature was found to slow down drastically as the c-Si interface is approached. From the Tauc-Lorentz parameters obtained from SE, it was found that the a-Si film exhibited properties that evolved with thickness suggesting that the deposited film is non-homogeneous across its depth. It was also found that the degree of crystallinity and optical (Tauc) bandgap increased as the layers were reduced in thickness and coming closer to the c-Si substrate interface, suggesting the presence of nano-structured clusters mixed into the amorphous phase for the region close to the crystalline silicon substrate. Further results from Atomic Force Microscopy and Transmission Electron Microscopy confirmed the presence of an interfacial transitional layer between the amorphous film and the underlying substrate showing silicon nano-crystalline enclosures that can lead to quantum confinement effects. Quantum confinement is suggested to be the cause of the observed increase in the optical bandgap of a-Si:H films close to the a-Si:H/cSi interface.

36 MATERIALS SCIENCE↗

Probes for investigating the effect of magnetic field, field orientation, temperature and strain on the critical current density of anisotropic high-temperature superconducting tapes in a split-pair 15 T horizontal magnet

We present the designs of probes for making critical current density (J{sub c}) measurements on anisotropic high-temperature superconducting tapes as a function of field, field orientation, temperature and strain in our 40 mm bore, split-pair 15 T horizontal magnet. Emphasis is placed on the design of three components: the vapour-cooled current leads, the variable temperature enclosure, and the springboard-shaped bending beam sample holder. The vapour-cooled brass critical-current leads used superconducting tapes and in operation ran hot with a duty cycle (D) of ∼0.2. This work provides formulae for optimising cryogenic consumption and calculating cryogenic boil-off, associated with current leads used to make J{sub c} measurements, made by uniformly ramping the current up to a maximum current (I{sub max}) and then reducing the current very quickly to zero. They include consideration of the effects of duty cycle, static helium boil-off from the magnet and Dewar (b{sup ′}), and the maximum safe temperature for the critical-current leads (T{sub max}). Our optimized critical-current leads have a boil-off that is about 30% less than leads optimized for magnet operation at the same maximum current. Numerical calculations show that the optimum cross-sectional area (A) for each current lead can be parameterized by LI{sub max}/A=[1.46D{sup −0.18}L{sup 0.4}(T{sub max}−300){sup 0.25D{sup −{sup 0{sup .{sup 0{sup 9}}}}}}+750(b{sup ′}/I{sub max})D{sup 10{sup −{sup 3I{sub m}{sub a}{sub x}−2.87b{sup ′}}}}]× 10{sup 6}A m{sup −1} where L is the current lead's length and the current lead is operated in liquid helium. An optimum A of 132 mm{sup 2} is obtained when I{sub max} = 1000 A, T{sub max} = 400 K, D = 0.2, b{sup ′} = 0.3 l h{sup −1} and L = 1.0 m. The optimized helium consumption was found to be 0.7 l h{sup −1}. When the static boil-off is small, optimized leads have a boil-off that can be roughly parameterized by: b/I{sub max } ≈ (1.35 × 10{sup −3})D{sup 0.41} l h{sup ‑1} A{sup −1}. A split-current-lead design is employed to minimize the rotation of the probes during the high current measurements in our high-field horizontal magnet. The variable-temperature system is based on the use of an inverted insulating cup that operates above 4.2 K in liquid helium and above 77.4 K in liquid nitrogen, with a stability of ±80 mK to ±150 mK. Uniaxial strains of −1.4% to 1.0% can be applied to the sample, with a total uncertainty of better than ±0.02%, using a modified bending beam apparatus which includes a copper beryllium springboard-shaped sample holder.

43 PARTICLE ACCELERATORS↗

Limitation of parallel flow in double diffusive convection: Two- and three-dimensional transitions in a horizontal porous domain

Two-dimensional (2D) and three-dimensional (3D) numerical simulations of double diffusion natural convection in an elongated enclosure filled with a binary fluid saturating a porous medium are carried out in the present work. The Boussinesq approximation is made in the formulation of the problem, and Neumann boundary conditions for temperature and concentration are adopted, respectively, on vertical and horizontal walls of the cavity. The used numerical method is based on the control volume approach, with the third order quadratic upstream interpolation scheme in approximating the advection terms. A semi implicit method algorithm is used to handle the velocity-pressure coupling. To avoid the excessively high computer time inherent to the solution of 3D natural convection problems, full approximation storage with full multigrid method is used to solve the problem. A wide range of the controlling parameters (Rayleigh-Darcy number Ra, lateral aspect ratio Ay, Lewis number Le, and the buoyancy ration N) is investigated. We clearly show that increasing the depth of the cavity (i.e., the lateral aspect ratio) has an important effect on the flow patterns. The 2D perfect parallel flows obtained for small lateral aspect ratio are drastically destabilized by increasing the cavity lateral dimension. This yields a 3D fluid motion with a much more complex flow pattern and the usually considered 2D parallel flow model cannot be applied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analyzer-based phase-contrast imaging system using a micro focus x-ray source

Here we describe a new in-laboratory analyzer based phase contrast-imaging (ABI) instrument using a conventional X-ray tube source (CXS) aimed at bio-medical imaging applications. Phase contrast-imaging allows visualization of soft tissue details usually obscured in conventional X-ray imaging. The ABI system design and major features are described in detail. The key advantage of the presented system, over the few existing CXS ABI systems, is that it does not require high precision components, i.e., CXS, X-ray detector, and electro-mechanical components. To overcome a main problem introduced by these components, identified as temperature stability, the system components are kept at a constant temperature inside of three enclosures, thus minimizing the electrical and mechanical thermal drifts. This is achieved by using thermoelectric (Peltier) cooling/heating modules that are easy to control precisely. For CXS we utilized a microfocus X-ray source with tungsten (W) anode material. In addition the proposed system eliminates tungsten's multiple spectral lines by selecting monochromator crystal size appropriately therefore eliminating need for the costly mismatched, two-crystal monochromator. The system imaging was fine-tuned for tungsten Kα{sub 1} line with the energy of 59.3 keV since it has been shown to be of great clinical significance by a number of researchers at synchrotron facilities. In this way a laboratory system that can be used for evaluating and quantifying tissue properties, initially explored at synchrotron facilities, would be of great interest to a larger research community. To demonstrate the imaging capability of our instrument we use a chicken thigh tissue sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-channel Doppler backscattering measurements in the C-2 field reversed configuration

A versatile heterodyne Doppler Backscattering (DBS) system is used to measure density fluctuation levels (in the wavenumber range kρ{sub s} ≤ 50), and the toroidal E × B flow velocity in the C-2 Field-Reversed Configuration (FRC). Six tunable frequencies in three waveguide bands (26 GHz ≤ f ≤ 90 GHz) are launched using monostatic beam optics, via a quasi-optical beam combiner/polarizer and an adjustable parabolic focusing mirror (inside the vacuum enclosure) achieving Gaussian beam spot sizes of 3–5.5 cm at the X/O-mode cutoff. The DBS system covers plasma densities of 0.8 × 10{sup 13} ≤ n{sub e} ≤ 1 × 10{sup 14} cm{sup −3}, and provides access to the FRC core (up to the field null) and across the FRC separatrix into the scrape-off layer plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Knudsen torque on heated micro beams

Thermally induced mechanical loading has been shown to have significant effects on micro/nano objects immersed in a gas with a non-uniform temperature field. While the majority of existing studies and related applications focus on forces, we investigate the torque, and thus the rotational motion, produced by such a mechanism. Using the asymptotic analysis in the near continuum regime, the Knudsen torque acting on an asymmetrically located uniformly heated microbeam in a cold enclosure is investigated. The existence of a non-zero net torque is demonstrated. In addition, it has been found that by manipulating the system configuration, the rotational direction of the torque can be changed. Two types of rotational motion of the microbeam have been identified: the pendulum motion of a rectangular beam, and the unidirectional rotation of a cylindrical beam. A rotational frequency of 4 rpm can be achieved for the cylindrical beam with a diameter of 3μm at Kn = 0.005. Illustrated by the simulations using the direct simulation of Monte Carlo, the Knudsen torque can be much increased in the transition regime, demonstrating the potential of Knudsen torque serving as a rotation engine for micro/nano objects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗