Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron tubes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Hot rolling of ZK60 magnesium sheet with isotropic tensile properties from tubing made by Shear Assisted Processing and Extrusion (ShAPE)

In order to evaluate the viability of ShAPE processed Mg alloys as a feedstock for fabricating lightweight sheet material, tubes consisting of ShAPE-extruded Mg alloy ZK60 were flattened into plates and hot rolled at 450 °C to reductions of 37%, 68%, and 93%. The mechanical properties and microstructure of the rolled material were characterized through tensile testing and electron backscattered diffraction (EBSD). ZK60 specimens rolled to 68% reduction had tensile properties similar to published properties of rolled ZK60 sheets fabricated using conventional processes, and exhibited negligible tensile anisotropy referenced to the rolling direction. Additional rolling from 68% to 93% reduced the ultimate tensile stress in the rolling direction from 341.74±5.96 MPa to 260.76±22.4MPa. The yield stress and elongation to failure of the material also decreased from 292.16±1.11 MPa to 256.93±18.4 MPa and 6.95±1.94% to 3.38±0.51%, respectively, but negligible little anisotropy was observed with respect to loading direction. EBSD mapping indicated that the as-extruded ZK60 had texture rotated away from the basal direction which developed into a strong basal texture over numerous hot rolling steps. This evolution in texture has been observed after rolling for hot-rolled ZK60 fabricated through conventional extrusion processes. The initial grain structure was found to have experienced noticeable twinning from flattening the tube into plate. After hot rolling, the grain structure became more equiaxed, but the average grain diameter did not change appreciably from 5.15 ± 3.39 µm in the ShAPE extruded material, to 5.27 ± 12.44 µm in the 93% hot rolled sheet. This response to hot rolling is similar to the response of ZK60 fabricated using other methods such as Equal Channel Angular Processing (ECAP). Therefore, this work demonstrates ShAPE has the potential as an alternative method to producing feedstock for Mg alloy sheets. Modifications to the experimental procedure which could lead to improvements in observed properties are briefly discussed.

36 MATERIALS SCIENCE↗

Exosomes secreted from mesenchymal stem cells mediate the regeneration of endothelial cells treated with rapamycin by delivering pro-angiogenic microRNAs

Highlights: • MSC-derived exosomes play an important role in promoting endothelial regeneration treated with rapamycin in vitro. • A distinct class of exosomal miRNAs is identified to be tightly related to endothelial regeneration. • The therapeutic effects of MSC-exosomes may be ascribed to the delivery of pro-angiogenic miRNAs to endothelial cells. • MSC-exosomes may serve as a cell-free therapy for clinical treatment of delayed endothelial healing after DES implantation. Delayed endothelial healing after drug eluting stent (DES) implantation is a critical clinical problem in treatment of coronary artery diseases. Exosomes exhibit proangiogenic potential in a variety of ischemic diseases. However, the association of exosomes with endothelial regeneration after DES implantation has been rarely reported. In this study, we aimed to investigate the therapeutic effects of mesenchymal stem cell (MSC)-derived exosomes on endothelial cells treated with rapamycin and explore the potential mechanisms of MSC-derived exosomes in promoting endothelial regeneration. Exosomes were isolated from MSCs by ultracentrifugation and identified by transmission electron microscopy, nanoparticle tracking analysis, and Western blot assay. The in vitro effects of MSC-derived exosomes on the proliferation and migration of endothelial cells treated with rapamycin were evaluated by integrated experiment, cell counting kit-8, scratch, tube formation, and transwell assays. And the apoptosis of rapamycin-induced endothelial cells loaded with MSC-derived exosomes was detected using TUNEL and Annexin-V FITC and PI double-staining assays. The microRNA (miRNA) cargo of MSC-derived exosomes was identified by high-throughput RNA sequencing. Pro-angiogenic miRNAs and key pathways were further characterized. Our results indicated that MSC-derived exosomes could be ingested into umbilical vein endothelial cells (HUVECs) and significantly enhanced cell proliferation rate, migratory and tube-forming capabilities in vitro. MSC-derived exosomes also inhibited the apoptosis of HUVECs induced by rapamycin. A distinct class of exosomal miRNAs was further identified, including six miRNAs tightly related to neovasculogenesis. Silencing the expression of exosomal miRNA-21–5p and let-7c-5p attenuated the pro-proliferative and pro-migratory capacity of MSC-derived exosomes. Moreover, functional enrichment analysis indicated that metabolic pathways might contribute to reendothelialization. This study highlights a proregenerative effect of MSC-derived exosomes in vitro, which may be partly explained by the delivery of pro-angiogenic miRNAs to endothelial cells.

60 APPLIED LIFE SCIENCES↗

Direct conversion of light to radio frequency energy

A description is presented of the test results obtained with the latest models of the phototron. The phototron was conceived as a replacement for the high voltage solar cell-high power klystron combination for the solar power satellite concept. Physically, the phototron is a cylindrical evacuated glass tube with a photocathode, two grids, and a reflector electrode in a planar configuration. The phototron can be operated either in a biased mode where a low voltage is used to accelerate the electron beam produced by the photocathode or in an unbiased mode referred to as self-oscillation. The device is easily modulated by light input or voltage to broadcast in AM or FM. The range of operation of the present test model phototrons is from 2 to 200 MHz.

Freeman, J. W.↗

Key Intermediate Nanostructures in the Self-Assembly of Amphiphilic Polypeptoids Revealed by Cryo-TEM

Amphiphilic copolypeptoids are known to form a variety of nanostructures (fibers, tubes, sheets, etc.), but the assembly mechanisms and key intermediates remain underexplored. This study investigates the intermediate structures formed during the early stages of self-assembly in diblock copolypeptoids using cryo-transmission electron microscopy (cryo-TEM). Here we focused on two diblock copolypeptoids, one with a free N-terminus and the other with a capped N-terminus, which ultimately form less-ordered nanofibers and well-ordered nanosheets, respectively. Through cryo-TEM imaging of vitrified solutions at various time points during the self-assembly process, the study identified micelles and vesicles as key intermediate structures. Notably, the formation of vesicles as intermediates is unusual in crystallization-driven self-assembly and suggests a unique pathway in polypeptoid self-assembly. The study provides direct imaging evidence of key intermediates in polypeptoid self-assembly, advancing the understanding of their self-assembly mechanisms.

59 BASIC BIOLOGICAL SCIENCES↗

Global gyrokinetic simulations of kinetic-ballooning-mode turbulence in Wendelstein 7-X

We apply the global gyrokinetic code GENE-3D to perform kinetic-ballooning-mode (KBM) turbulence simulations in the Wendelstein 7-X (W7-X) stellarator using experimentally relevant parameters. In contrast to the flux-tube approach, we observe saturation of the turbulent fluctuations at finite amplitude. Analyzing the turbulent characteristics, we identify the presence of weakly driven KBM turbulence hybridizing with ion-temperature-gradient and trapped-electron-mode turbulence in the scenario under consideration, showing that it is possible that KBM activity can be driven in W7-X, opening up the path for studying this type of turbulence, which is highly relevant for future fusion power plants.

Electrostatics↗

Design, construction and evaluation of a 12.045 GHz, 2.0 kW-cw permanent-magnet focused klystron amplifier

An analytical and experimental program to demonstrate the technical feasibility of a lightweight, high-efficiency, 1-2 kW cw, permanent magnet focused klystron operating at 12.0 GHz was described. The design is based on use of a samarium-cobalt permanent magnet for focusing of the electron beam and choice of the most optimum parameters for maximum efficiency. A filter-loaded output circuit is used for the required bandwidth. The design incorporates a collector which is demountable from the tube to facilitate multistage depressed collector experiments, permitting replacement with a NASA-designed axisymmetric, electrostatic collector for linear beam microwave tubes. A further requirement is that the focusing field between the last interaction gap and the collector decay in a prescribed manner referred to as adiabatic expansion.

Nishida, J. M.↗

Thermal alteration of young kerogen in relation to petroleum genesis

Kerogen, humic acid, and lipid material were separated from a young marine sediment and heated in sealed tubes in a nitrogen atmosphere at 150 and 410 C. Gaseous and liquid products generated during heating, and also the residual organic material, were characterized by gas-liquid chromatography, elemental analysis, infrared and electron spin resonance spectroscopy, and X-ray diffraction.

Ishiwatari, R.↗

Integrated development facility for the calibration of low-energy charged particle flight instrumentation

The design of a low-energy ion facility for development and calibration of thermal ion instrumentation is examined. A directly heated cathode provides the electrons used to produce ions by impact ionization and an applied magnetic field increases the path length followed by the electrons. The electrostatic and variable geometry magnetic mirror configuration in the ion source is studied. The procedures for the charge neutralization of the beam and the configuration and function of the 1.4-m drift tube are analyzed. A microcomputer is utilized to control and monitor the beam energy and composition, and the mass- and angle-dependent response of the instrument under testing. The facility produces a high-quality ion beam with an adjustable range of energies up to 150 eV; the angular divergence and uniformity of the beam is obtained from two independent retarding potential analyzers. The procedures for calibrating the instrument being developed are described.

Biddle, A. P.↗

Balloon measurements of cosmic ray protons and helium over half a solar cycle 1965-1969.

Evaluation of differential energy spectra for protons and helium covering the energy range from 100 to 260 MeV/nucleon obtained from balloon flights made each summer (1965 to 1969) at Churchill, Manitoba, with the aid of a Geiger-tube hodoscope operated in conjunction with two scintillation elements used to measure dE/dx and E. Supplementary data from balloon flights at Minneapolis, Minn., and Sioux Falls, S. Dak. and from calibration exposures to protons and electrons were used to define backgrounds and to verify the predicted detector response. The observed proton spectra are characterized over a wide range of energy (30 to 300 MeV) by a simple relationship between cosmic-ray intensity J and kinetic energy T: J = AT. The helium spectra also follow this law at solar maximum but rise less steeply near solar minimum. This characteristic behavior can be interpreted in terms of a simple model in which convection is balanced by adiabatic deceleration.-

Rygg, T. A.↗

Evaluation of magnetic refocusing in linear-beam microwave tubes

Magnetic field configurations in which the axial component of the field decays linearly to a constant plateau field are evaluated for use in refocusing the output beam of linear beam microwave tubes. The slope of the decay and the value of the plateau field are parameters in this study. A uniform beam with a space charge force only in the radial direction is assumed, and the electron trajectories are computed for various classes. For a given magnetic configuration (slope and plateau value) the plateau length is calculated for a specified class and the rms deviation of the output angles for all classes is computed at the end of this plateau length. A minimum condition for a refocused beam is defined to be one in which the rms value of the output angles is less than the rms input. Many of the configurations satisfied this criteria and successfully reduced the rms value by half.

Stankiewicz, N.↗

Flow sensor for biomedical fluids

Electronic sensor accurately measures and controls flow of plasma, whole blood, or drugs in solution. Since sensor does not directly contact fluid, it does not have to be sterilized. It is compatible with disposable bottles, tubes, and hypodermic needles widely used in hospitals. Only modification necessary is in tube, which must contain two small metal inserts, spaced to fit in curved thermistor plates.

Winkler, H. E.↗

Production of hydrogen by electron transfer catalysis using conventional and photochemical means

Alternate methods of generating hydrogen from the sulfuric acid thermal or electrochemical cycles are presented. A number of processes requiring chemical, electrochemical or photochemical methods are also presented. These include the design of potential photoelectrodes and photocatalytic membranes using Ru impregnated nafion tubing, and the design of experiments to study the catalyzed electrolytic formation of hydrogen and sulfuric acid from sulfur dioxide and water using quinones as catalysts. Experiments are carried out to determine the value of these approaches to energy conversion.

Rillema, D. P.↗

In situ measurements of the plasma bulk velocity near the Io flux tube

The flow around the Io flux tube was studied by analyzing the eleven spectra taken by the Voyager 1 Plasma Science (PLS) experiment in its vicinity. The bulk plasma parameters were determined using a procedure that uses the full response function of the instrument and the data in all four PLS sensors. The mass density of the plasma in the vicinity of Io is found to be 22,500 + or - 2,500 amu/cu cm and its electron density is found to be 1500 + or - 200/cu cm. The Alfven speed was determined using three independent methods; the values obtained are consistent and taken together yield V sub A = 300 + or - 50 km/sec, corresponding to an Alfven Mach number of 0.19 + or - 0.02. For the flow pattern, good agreement was found with the model of Neubauer (1980), and it was concluded that the plasma flows around the flux tube with a pattern similar to the flow of an incompressible fluid around a long cylinder obstacle of radius 1.26 + or - 0.1 R sub Io.

Barnett, A.↗

Thermodynamic effect of the ion sound instability in the ionosphere

During geomagnetic disturbances when the ring current interacts intensely with the plasmasphere, the plasma of this region undergoes a strong heating due to an ion cyclotron instability. This is followed by the transfer of heat along geomagnetic field lines from the heating region to the ionosphere. One of the results of this process is the formation of non-isothermal region (in which T(sub e) greater than 3.4 T(sub i) at ionospheric heights) caused by a rapid cooling the H(+) ions due to their resonant charge exchange with neutral hydrogen. Heat transfer from the top of the flux tube to the ionosphere is investigated using a hydrodynamic model for the ionosphere-plasmasphere coupling. Field-aligned currents, present in the topside ionosphere, are often accompanied by ion sound turbulence. The turbulence scatters electrons, increasing the total electron collision frequency through wave-particle effects. The influence of wave-particle interactions introduces an anomalous component to the total collision frequency, which modifies substantially the heat conduction coefficient of the plasma. As a result, the plasma is heated more intensely above than below this region of ion sound turbulence.

Khazanov, G. V.↗

DyFK Simulation of Field-Aligned Ion Flows Observed by POLAR within Convecting Flux Over the Polar Ionosphere

Ion (O+ and H+) parallel flows along antisunward convecting flux tubes across the polar ionosphere from day to night side are simulated by an extended Dynamic Fluid semiKinetic (DyFK) model. The collision dominated portion of the flux tubes is treated with a moment-based fluid model for altitudes from 120 ?1100 km, while the generalized semikinetic model is used for the topside through 3 RE region. The effects of cleft/auroral soft electron precipitation and wave-driven transverse ion heating are incorporated into the generalized semi-kinetic treatment of topside ionosphere. The simulated evolution of field-aligned ion flow parameters is compared with observations made by the Thermal Ion Dynamics Experiment (TIDE) on board the POLAR satellite near 5000 km altitude over the southern hemisphere polar ionosphere.

Tu, J.-N.↗

Integrated Microbatteries for Implantable Medical Devices

Integrated microbatteries have been proposed to satisfy an anticipated need for long-life, low-rate primary batteries, having volumes less than 1 mm3, to power electronic circuitry in implantable medical devices. In one contemplated application, such a battery would be incorporated into a tubular hearing-aid device to be installed against an eardrum. This device is based on existing tube structures that have already been approved by the FDA for use in human ears. As shown in the figure, the battery would comprise a single cell at one end of the implantable tube. A small volume of Li-based primary battery cathode material would be compacted and inserted in the tube near one end, followed by a thin porous separator, followed by a pressed powder of a Li-containing alloy. Current-collecting wires would be inserted, with suitably positioned insulators to prevent a short circuit. The battery would contain a liquid electrolyte consisting of a Li-based salt in an appropriate solvent. Hermetic seals would be created by plugging both ends with a waterproof polymer followed by deposition of parylene.

Whitacre, Jay↗

Video simulator with electronic ranging

Gimbal orientation, raster shrinkage and deflection, and track movement are used to simulate attitude and range. Key component in system is video digitizer that converts vidicon camera signal to digital form, processes it to reduce image size, and reconverts processed data to analog signal for display on cathode ray tube.

Kraemer, W.↗

Study of the production of some superconducting and magnetic materials by solidification in the drop tube and drop tower

A systematic study on the relationship between the microstructure and physical properties of several superconducting materials prepared by solidification in low gravity was conducted. Further study of the materials, such as the applications of hydrostatic pressure which is known to be an effective mean to vary the electronic structure of materials, in conjunction with the detailed microstructure analysis of the samples was also performed to better understand the low gravity effects on the enhancement of the electronic properties. Results of the studies on the directionally solidified AlInSn alloys processed in the KC-135 aircraft and immiscible GaBi alloy prepared during free fall in the Marshall Space Flight Center Drop Tower are presented.

Wu, M. K.↗