Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electromagnetic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Measurement of the phase between strong and electromagnetic amplitudes in the decay J/ψ → ϕη

The first direct measurement of the relative phase between the strong and electromagnetic amplitudes for a J/ψ decaying into a vector-pseudoscalar final state is performed using 26 energy points of e + e − annihilation data between 3.00 GeV and 3.12 GeV. The data sets were collected by the BESIII detector with a total integrated luminosity of 452 pb −1 . By investigating the interference pattern in the cross section lineshape of e + e − → ϕη, the relative phase between the strong and electromagnetic amplitudes of J/ψ decay is determined to be within [133°, 228°] at 68% confidence level.

QCD↗

Valence quark contributions for the gamma N -> P11(1440) transition

A covariant spectator quark model is applied to estimate the valence quark contributions to the$ F1*(Q2) and F2*(Q2) transition form factors for the gamma N -> P11(1440) reaction. The Roper resonance, P11(1440), is assumed to be the first radial excitation of the nucleon. The model requires no extra parameters except for those already fixed by the previous studies for the nucleon. The results are consistent with the experimental data in the high Q2 region, and those from the lattice QCD. Finally the model is also applied to estimate the meson cloud contributions from the CLAS and MAID analysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Field–potential finite-difference time-domain (FiPo FDTD) technique for computational electromagnetics

Modeling light–matter interactions at the nanoscale requires accurate handling of coupled quantum and electromagnetic systems. This coupling requires information about the electric scalar potential Φ and the magnetic vector potential A, which are not typically calculated in standard computational electromagnetics implementations. To that end, we have developed a field–potential finite-difference time-domain (FiPo FDTD) algorithm, which solves a set of first-order equations for Φ and A alongside equations for the electric and magnetic fields E and H. The FiPo Basic code is essentially conventional FDTD, but with an added module that calculates the potentials. The FiPo Hybrid code self-consistently calculates both fields and potentials and is particularly suitable for coupling with quantum electronic transport solvers because it can be sourced by the potentials themselves. To terminate the domain and mimic infinite space, we have derived and implemented a convolutional perfectly matched layer (CPML) absorbing boundary condition for FiPo FDTD whose performance is on par with state-of-the-art CPMLs for standard FDTD. We present FiPo simulation results on several example systems.

Avazpour, L. [University of Wisconsin-Madison, WI ↗

Electromagnetic and Rotational Characteristics of a Superconducting Flywheel Energy Storage System Utilizing a Radial-Type High-Temperature Superconducting Bearing

A 2 kW/28.5 kJ superconducting flywheel energy storage system (SFESS) with a radial-type high-temperature superconducting (HTS) bearing was set up to study the electromagnetic and rotational characteristics. The structure of the SFESS as well as the design of its main parts was reported. A mathematical model based on the finite element method (FEM) was established to research the electromagnetic characteristics of the HTS bearing during the levitation process, which show that a part of the magnetic flux penetrates into the edge of the HTS bulks and then goes back to the opposite pole of the permanent magnet rotor (PMR). The induced current mainly distributes in the edge of the HTS bulks, indicating that larger force acts on the edge part of the HTS bulks and probably causes them to crack. The free rotations of the rotor at different steady-state speeds of 2500–5000 rpm and its radial vibration were displayed. The induced voltage of the stator winding of the motor in this process was analyzed. The rotational characteristics are related to the vibration of the rotor. Below the resonant frequency, the vibration increases significantly with the speed. Enhancing the radial stiffness to limit the vibration amplitude of the rotor is an effective approach to improve the speed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermal Conductivity Measurement of Molten Cu-Co Alloy Using an Electromagnetic Levitator Superimposed with a Static Magnetic Field

The thermal conductivity of molten Cu-Co alloy with different compositions around the liquidus line temperature was measured by the periodic laser-heating method using an electromagnetic levitator superimposed with a static magnetic field to suppress convection in a levitated droplet sample. During the measurement, a static magnetic field of 10 T was applied to the levitated droplet. To confirm that the strength of the static magnetic field was sufficient to suppress convection in the droplet, numerical simulations were performed for the flow and thermal fields in an electromagnetically levitated droplet under a static magnetic field, and moreover, for the periodic laser-heating method to determine the thermal conductivity. It was found that the thermal conductivity of molten Cu-Co alloy increased gradually with increasing Cu composition up to 80 at. pct, beyond which it increased markedly and reached that of pure Cu. In addition, it was found that the composition dependence of the thermal conductivity can be explainable by the Wiedemann–Franz law.

36 MATERIALS SCIENCE↗

Evolutions of the Micro- and Macrostructure and Tensile Property of Cu-15Ni-8Sn Alloy During Electromagnetic Stirring-Assisted Horizontal Continuous Casting

The present study investigates the evolution of the micro- and macrostructure and tensile property of the Cu-15Ni-8Sn (weight percent) alloy prepared by horizontal continuous casting and electromagnetic stirring (EMS). The results show that the application of EMS is beneficial for grain refinement and for microstructure transformation from the dendrite to the rosette structure and that it leads to a significant improvement in the tensile property. The forced flow induced by EMS homogenizes the temperature field ahead of the solid-liquid interface, disturbing the heat flow direction and resulting in the columnar to equiaxed transition. The grain refinement under different electromagnetic stirring frequencies is mainly derived from the homogenization of the temperature and the remelting of dendritic arms. In addition, the evolution of the tensile property with and without EMS is discussed from the perspective of fracture mode and fine-grain strengthening.

36 MATERIALS SCIENCE↗

Autoencoder-Based Anomaly Detection System for Online Data Quality Monitoring of the CMS Electromagnetic Calorimeter

The CMS detector is a general-purpose apparatus that detects high-energy collisions produced at the LHC. Online data quality monitoring of the CMS electromagnetic calorimeter is a vital operational tool that allows detector experts to quickly identify, localize, and diagnose a broad range of detector issues that could affect the quality of physics data. A real-time autoencoder-based anomaly detection system using semi-supervised machine learning is presented enabling the detection of anomalies in the CMS electromagnetic calorimeter data. A novel method is introduced which maximizes the anomaly detection performance by exploiting the time-dependent evolution of anomalies as well as spatial variations in the detector response. The autoencoder-based system is able to efficiently detect anomalies, while maintaining a very low false discovery rate. The performance of the system is validated with anomalies found in 2018 and 2022 LHC collision data. In addition, the first results from deploying the autoencoder-based system in the CMS online data quality monitoring workflow during the beginning of Run 3 of the LHC are presented, showing its ability to detect issues missed by the existing system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic mixing laws: A supersymmetric approach

In this article we address the old problem of finding the effective dielectric constant of materials described either by a local random dielectric constant, or by a set of non-overlapping spherical inclusions randomly dispersed in a host. We use a unified theoretical framework, such that all the most important Electromagnetic Mixing Laws (EML) can be recovered as the first iterative step of a family of results, thus opening the way to future improvements through the refinements of the approximation schemes. When the material is described by a set of immersed inclusions characterized by their spatial correlation functions, we exhibit an EML which, being featured by a minimal approximation scheme, does not come from the multiple scattering paradigm. It is made of a pure Hori-Yonezawa formula, corrected by a power series of the inclusion density. The coefficients of the latter, which are given as sums of standard diagrams, are recast into electromagnetic quantities which calculation is amenable numerically thanks to codes available on the web. The methods used and developed in this work are generic and can be used in a large variety of areas ranging from mechanics to thermodynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electromagnetic and gravitational interactions from Lagrangian mechanics

Highlights: • Background Maxwell and Einstein fields are universal features of Lagrangian systems. • The Lagrangian function is promoted to a dynamic field. • The Einstein–Maxwell theory is derived from Lagrangian mechanics. Background fields of electromagnetic and gravitational type emerge in the low kinetic energy limit of any regular Lagrangian system and, in particular, in the corresponding limit of any spacetime theory in which the free motion of test particles is described by an unspecified regular Lagrangian. Electromagnetic and gravitational type interactions are therefore a universal feature of low kinetic energy Lagrangian systems. These background interactions can be consistently turned into dynamic Einstein–Maxwell fields by promoting the Lagrangian function to a dynamic scalar field on the tangent bundle of the configuration space. Accordingly, Einstein–Maxwell theory can be deduced from the assumption that the motion of elementary test particles in spacetime is described by Lagrangian mechanics. For higher kinetic energy-type values, identified with the square of the invariant mass of the particle, the Lagrangian induces higher rank interactions that seem however too weak to have been detected in spacetime physics, but which might prove relevant at the Planck scale.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-intensity electromagnetic irradiation of 70.6 and 73 GHz frequencies enhances the effects of disulfide bonds reducer on Escherichia coli growth and affects the bacterial surface oxidation-reduction state

Highlights: {yields} Low intensity 70.6 and 73 GHz electromagnetic irradiation (EMI) strongly suppressed Escherichia coli growth at 73 GHz and pH 7.3. {yields} Reducer DL-dithiothreitol had bactericidal effect and disturbed the SH-groups number. {yields} EMI enhanced E. coli sensitivity toward dithiothreitol. {yields} EMI decreased the SH-groups number of membrane disturbed by ATP and N,N'-dicyclohexycarbodiimide. {yields} The changed membrane oxidation-reduction state could be the primary mechanisms in EMI effects. -- Abstract: Low-intensity electromagnetic irradiation (EMI) of 70.6 and 73 GHz frequencies (flux capacity - 0.06 mW cm{sup -2}) had bactericidal effects on Escherichia coli. This EMI (1 h) exposure suppressed the growth of E. coli K-12({lambda}). The pH value (6.0-8.0) did not significantly affect the growth. The lag-phase duration was prolonged, and the growth specific rate was inhibited, and these effects were more noticeable after 73 GHz irradiation. These effects were enhanced by the addition of DL-dithiothreitol (DTT), a strong reducer of disulfide bonds in surface membrane proteins, which in its turn also has bactericidal effect. Further, the number of accessible SH-groups in membrane vesicles was markedly decreased by EMI that was augmented by N,N'-dicyclohexycarbodiimide and DTT. These results indicate a change in the oxidation-reduction state of bacterial cell membrane proteins that could be the primary membranous mechanism in the bactericidal effects of low-intensity EMI of the 70.6 and 73 GHz frequencies.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Achieving superior electromagnetic wave absorbers through the novel metal-organic frameworks derived magnetic porous carbon nanorods

High absorption capacity and broad absorption bandwidth electromagnetic wave (EMW) absorption materials (namely, EMW absorbers) are highly desirable due to the interference with electronics and harms on human beings’ health. In search for rational design on nanostructured absorbers, we have synthesized and demonstrated the rod-shape composites with Fe-containing magnetic nanoparticles (Fe 3 O 4 , Fe 3 C and Fe NPs) embedded into nano-porous carbon (NPC) through pyrolysis of Fe-based metal-organic frameworks (MOFs). The morphologies, compositions, and graphitization degree of the Fe-MOFs derived magnetic NPC nanorods can be effectively controlled via adjusting the pyrolysis temperatures. The graphitization level has a significant influence on the permittivity of the composites upon variation of pyrolysis temperatures, thereby a tunable electromagnetic wave (EMW) absorption is observed. Consequently, the resulting magnetic NPC nanorods obtained at pyrolysis temperature of 600 and 700 °C exhibit the most remarkable EMW absorption performance with a strong reflection loss of -52.9 dB and broad effective bandwidth (f e ) of 4.64 GHz at 3.07 mm. With a thickness of 3.5 mm, the f e for the magnetic NPC nanorods at 600 °C covers the whole X-band from 7.92 to 12.48 GHz. Finally, the noticeable EMW absorption performances have been greatly enhanced compared to those reported Fe 3 O 4 based absorbers, owing to the synergy of multiple components and the porous structures inherited from MOFs.

36 MATERIALS SCIENCE↗

A multi-dimensional, energy- and charge-conserving, nonlinearly implicit, electromagnetic Vlasov–Darwin particle-in-cell algorithm

For decades, the Vlasov–Darwin model has been recognized to be attractive for particle-in-cell (PIC) kinetic plasma simulations in non-radiative electromagnetic regimes, to avoid radiative noise issues and gain computational efficiency. However, the Darwin model results in an elliptic set of field equations that renders conventional explicit time integration unconditionally unstable. We explore a fully implicit PIC algorithm for the Vlasov–Darwin model in multiple dimensions, which overcomes many difficulties of traditional semi-implicit Darwin PIC algorithms. The finite-difference scheme for Darwin field equations and particle equations of motion is space–time-centered, employing particle sub-cycling and orbit-averaging. This algorithm conserves total energy, local charge, canonical-momentum in the ignorable direction, and preserves the Coulomb gauge exactly. An asymptotically well-posed fluid preconditioner allows efficient use of large cell sizes, which are determined by accuracy considerations, not stability, and can be orders of magnitude larger than required in a standard explicit electromagnetic PIC simulation. Finally, we demonstrate the accuracy and efficiency properties of the algorithm with various numerical experiments in 2D–3V.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A hybrid nodal-staggered pseudo-spectral electromagnetic particle-in-cell method with finite-order centering

Electromagnetic particle-in-cell (PIC) codes are widely used to perform computer simulations of a variety of physical systems, including fusion plasmas, astrophysical plasmas, plasma wakefield particle accelerators, and secondary photon sources driven by ultra-intense lasers. In a PIC code, Maxwell's equations are solved on a grid with a numerical method of choice. This article focuses on pseudo-spectral analytical time-domain (PSATD) algorithms and presents a novel hybrid PSATD PIC scheme that combines the respective advantages of standard nodal and staggered methods. The novelty of the hybrid scheme consists in using finite-order centering of grid quantities between nodal and staggered grids, in order to combine the solution of Maxwell's equations on a staggered grid with the deposition of charges and currents and the gathering of electromagnetic forces on a nodal grid. The correctness and performance of the novel hybrid scheme are assessed by means of numerical tests that employ different classes of PSATD equations in a variety of physical scenarios, ranging from the modeling of electron-positron pair creation in vacuum to the simulation of laser-driven and particle beam-driven plasma wakefield acceleration. It is shown that the novel hybrid scheme offers significant numerical and computational advantages, compared to purely nodal or staggered methods, for all the test cases presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spatial decay of electromagnetic waves from hypervelocity impact plasmas

Due to the high kinetic energy of impactors in space, hypervelocity impacts on spacecraft can ablate spacecraft material and produce plasmas. These plasmas have been observed in ground-based experiments to produce electromagnetic pulses (EMPs) and are suspected to be a cause of spacecraft anomalies. The initial EMP that is produced after plasma formation is replicated using a 2D electromagnetic plasma simulation, consisting of a discontinuous Galerkin, particle-in-cell (DG-PIC) framework. The spontaneous formation of EMPs from an initial quasineutral plasma is consistent with previous works and show behavior similar to that of waves emitted by antennas. The EMP emits from the plasma with a frequency less than the plasma frequency associated with the point of maximum density, showing the importance of the density gradient, and the far-field region of the “plasma antenna” is estimated. From the proportionality between plasma frequency and EMP frequency, there is a direct correlation between plasma density and radiation. Finally, as the plasma density decreases, the EMP frequency decreases, which suggests that several observable phenomena, such as optical flashes, radio frequency emission, and microwave emission, all result from the same plasma-related mechanism within a single hypervelocity impact.

42 ENGINEERING↗

Fiducial-Based Translational Localization Accuracy of Electromagnetic Tracking System and On-Board Kilovoltage Imaging System

Purpose: The Calypso medical four-dimensional localization system uses AC electromagnetics, which do not require ionizing radiation, for accurate, real-time tumor tracking. This investigation compared the static and dynamic tracking accuracy of this system to that of an on-board imaging kilovoltage X-ray system for concurrent use of the two systems. Methods and Materials: The localization accuracies of a kilovoltage imaging system and a continuous electromagnetic tracking system were compared. Using an in-house developed four-dimensional stage, quality-assurance fixture containing three radiofrequency transponders was positioned at a series of static locations and then moved through the ellipsoidal and nonuniform continuous paths. The transponder positions were tracked concurrently by the Calypso system. For static localization, the transponders were localized using portal images and digitally reconstructed radiographs by commercial matching software. For dynamic localization, the transponders were fluoroscopically imaged, and their positions were determined retrospectively using custom-written image processing programs. The localization data sets were synchronized with and compared to the known quality assurance fixture positions. The experiment was repeated to retrospectively track three transponders implanted in a canine lung. Results: The root mean square error of the on-board imaging and Calypso systems was 0.1 cm and 0.0 cm, respectively, for static localization, 0.22 mm and 0.33 mm for dynamic phantom positioning, and 0.42 mm for the canine study. Conclusion: The results showed that both localization systems provide submillimeter accuracy. The Calypso and on-board imaging tracking systems offer distinct sets of advantages and, given their compatibility, patients could benefit from the complementary nature of the two systems when used concurrently.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integration of Real-Time Internal Electromagnetic Position Monitoring Coupled With Dynamic Multileaf Collimator Tracking: An Intensity-Modulated Radiation Therapy Feasibility Study

Purpose: Continuous tumor position measurement coupled with a tumor tracking system would result in a highly accurate radiation therapy system. Previous internal position monitoring systems have been limited by fluoroscopic radiation dose and low delivery efficiency. We aimed to incorporate a continuous, electromagnetic, three-dimensional position tracking system (Calypso 4D Localization System) with a dynamic multileaf collimator (DMLC)-based dose delivery system. Methods and Materials: A research version of the Calypso System provided real-time position of three Beacon transponders. These real-time three-dimensional positions were sent to research MLC controller with a motion-tracking algorithm that changed the planned leaf sequence. Electromagnetic transponders were embedded in a solid water film phantom that moved with patient lung trajectories while being irradiated with two different plans: a step-and-shoot intensity-modulated radiation therapy (S-IMRT) field and a dynamic IMRT (D-IMRT) field. Dosimetric results were recorded under three conditions: no intervention, DMLC tracking, and a spatial gating system. Results: Dosimetric accuracy was comparable for gating and DMLC tracking. Failure rates for gating/DMLC tracking are as follows: {+-}3 cGy 10.9/ 7.5% for S-IMRT, 3.3/7.2% for D-IMRT; gamma (3mm/3%) 0.2/1.2% for S-IMRT, 0.2/0.2% for D-IMRT. DMLC tracking proved to be as efficient as standard delivery, with a two- to fivefold efficiency increase over gating. Conclusions: Real-time target position information was successfully integrated into a DMLC effector system to modify dose delivery. Experimental results show both comparable dosimetric accuracy as well as improved efficiency compared with spatial gating.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Linear Accelerator Gating With Real-Time Electromagnetic Tracking

Purpose: Intrafraction organ motion can produce dosimetric errors in radiotherapy. Commonly, the linear accelerator is gated using real-time breathing phase obtained by way of external sensors. However, the external anatomy does not always correlate well with the internal position. We examined a beam gating technique using signals from implanted wireless transponders that provided real-time feedback on the tumor location without an imaging dose to the patient. Methods and Materials: An interface was developed between Calypso Medical's four-dimensional electromagnetic tracking system and a Varian Trilogy linear accelerator. A film phantom was mounted on a motion platform programmed with lung motion trajectories. Deliveries were performed when the beam was gated according to the signal from the wireless transponders. The dosimetric advantages of beam gating and the system latencies were quantified. Results: Beam gating using on internal position monitoring provided up to a twofold increase in the dose gradients. The percentage of points failing to be within {+-}10 cGy of the planned dose (maximal dose, {approx}200 cGy) was 3.4% for gating and 32.1% for no intervention in the presence of motion. The mean latencies between the transponder position and linear accelerator modulation were 75.0 {+-}12.7 ms for beam on and 65.1 {+-} 12.9 ms for beam off. Conclusion: We have presented the results from a novel method for gating the linear accelerator using trackable wireless internal fiducial markers without the use of ionizing radiation for imaging. The latencies observed were suitable for gating using electromagnetic fiducial markers, which results in dosimetric improvements for irradiation in the presence of motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of Electromagnetic Transponder Use to Monitor Inter- and Intrafractional Motion in Locally Advanced Pancreatic Cancer Patients

Purpose: The primary objective of this study was to determine the feasibility of electromagnetic transponder implantation in patients with locally advanced unresectable pancreatic cancer. Secondarily, the use of transponders to monitor inter- and intrafractional motion, and the efficacy of breath holding for limiting target motion, were examined. Methods and Materials: During routine screening laparoscopy, 5 patients without metastatic disease were implanted with transponders peri-tumorally. The Calypso System's localization and tracking modes were used to monitor inter- and intrafractional motion, respectively. Intrafractional motion, with and without breath holding, was also examined using Calypso tracking mode. Results: Transponder implantation was well tolerated in all patients, with minimal migration, aside from 1 patient who expulsed a single transponder. Interfractional motion based on mean shifts from setup using tattoos/orthogonal imaging to transponder based localization from 164 treatments was significant in all dimensions. Mean shift (in millimeters), followed by the standard deviation and p value, were as follows: X-axis: 4.5 mm (1.0, p = 0.01); Y axis: 6.4 mm (1.9, p = 0.03); and Z-axis 3.9 mm (0.6, p = 0.002). Mean intrafractional motion was also found to be significant in all directions: superior, 7.2 mm (0.9, p = 0.01); inferior, 11.9 mm (0.9, p < 0.01); anterior: 4.9 mm (0.5, p = 0.01); posterior, 2.9 mm (0.5, p = 0.02); left, 2.2 mm (0.4, p = 0.02); and right, 3.1 mm (0.6, p = 0.04). Breath holding during treatment significantly decreased tumor motion in all directions. Conclusions: Electromagnetic transponder implantation appears to be safe and effective for monitoring inter- and intrafractional motion. Based on these results a larger clinical trial is underway.

62 RADIOLOGY AND NUCLEAR MEDICINE↗