Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical resistivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Determination of Ground Subsidence Around Snow Fences in the Arctic Region

In this study, we analyzed the effects of snow cover changes caused by snow fences (SFs) installed in 2017 in the Alaskan tundra to examine ground subsidence. Digital surface model data obtained through LiDAR-based remote sensing in 2019 and 2022, combined with a field survey in 2021, revealed approximately 0.2 m of ground subsidence around the SF. To investigate the relationship between SF-induced snow cover changes and ground subsidence, geophysical methods, electrical resistivity tomography (ERT) and ground-penetrating radar (GPR), were applied in 2023 to analyze subsurface characteristics. The increased snow cover due to the SF-enhanced insulation, delaying the penetration of winter cold into the subsurface. This delay caused subsurface temperatures to decrease more slowly, melting the upper permafrost and increasing the thickness of the active layer. ERT and GPR surveys well delineated the boundary between the active layer and permafrost, confirming that the increased snow cover thickened the active layer. This thickening led to the melting of pore ice, causing water runoff and ground compaction, which resulted in subsidence. The runoff also formed channels flowing eastward over the SF. This study highlights how changes in snow cover can influence active layer properties, leading to localized environmental changes and ground subsidence.

54 ENVIRONMENTAL SCIENCES↗

Kinetic effects of self-organization in low-temperature magnetized plasmas (Final Report for DE-SC0019045: 9/1/2018-8/31/2019)

The research goal of this Early Career Research Program project is to advance the science of low temperature magnetized plasmas using first-principles kinetic, e.g., solving the Boltzmann equation, models. A better understanding of the plasma transport properties, such as electrical resistivity and thermal conductivity must be obtained to better control and design magnetized plasma sources. A key physical phenomenon in low-temperature magnetized plasmas is the self-organization of plasma flows, e.g., coherent plasma structures and transition between different discharge modes. Understanding the physics of coherent plasma structures has been identified as one of the four important frontier topics in a recent workshop by the Office of Fusion Energy Science. These self-emerging plasma patterns results from the nonlinear coupling between plasma constituents (ions, electrons, and neutral atoms), electromagnetic fields, and materials. The physics of low-temperature magnetized plasmas is particularly complex because (i) the collisionless instabilities affect collisional phenomena (ionization, transport, etc.) and vice versa and (ii) the presence of materials (sheath, electron injection, etc.) influences the bulk plasma properties in low-temperature plasma (LTP) devices. Computational models of these plasma flows remain challenging because the plasma density can vary several orders of magnitudes, a wide range of temporal and spatial scales must be resolved, the phenomena are inherently three-dimensional, and various physical processes, such as wall interaction, instabilities, inelastic collisions, etc., must be simultaneously and self-consistently taken into account. Understanding the fundamental transport mechanisms in cross-field configurations enables additional controllability of plasma properties and electron energy distribution functions (EEDFs).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Project Plan: Salt in Situ Heater Test

This project plan gives a high-level description of the US Department of Energy Office of Nuclear Energy (DOE-NE) Spent Fuel and Waste Disposition (SFWD) campaign in situ borehole heater test project planned for the Waste Isolation Pilot Plant (WIPP) site, titled the Brine Availability Test in Salt (BATS). BATS is the first stage in a planned sequence of tests to bolster the technical basis for disposal of heat generating waste in salt. This plan provides an overview of the schedule and responsibilities of the parties involved. This project is a collaborative effort by Sandia, Los Alamos, and Lawrence Berkeley National Laboratories to execute a series of small-diameter borehole heater tests in salt for the DOE-NE SFWD campaign. Design of a heater test in salt at WIPP has evolved over several years. The experiment has begun in January 2020 and the first phase will continue for several months with the possibility for follow on testing. BATS comprises a suite of modular tests, which consist of a group of adjacent horizontal boreholes in the wall of drifts at WIPP. Each test is centered around a packer-isolated heated borehole (12.2 cm [4.81 diameter) containing equipment for water-vapor collection and borehole closure monitoring, surrounded by smaller-diameter (up to 5.3 cm [2.11 diameter) satellite observation boreholes. Observation boreholes contain grouted-in temperature sensors, electrical resistivity tomography (ERT) sensors, and fiber optics; packer-isolated tracer release and sampling intervals; and acoustic emission (AE) piezoelectric sensors. A larger-diameter (12.2 cm [4.81) satellite borehole includes sorel and salt cement plugs, as part of an engineered barrier sealing test. The first two tests, to be implemented in parallel, are heated (target borehole wall temperature of 120 °C) and unheated, with similar arrays of observation borehole monitoring changes. Follow-on tests will be designed using information gathered from the first two tests, and may be conducted at other borehole wall temperatures, use multiple observation boreholes, and may include different measurement types and test designs. This 2020 update of the original 2018 project plan satisfies DOE-NE Spent Fuel and Waste Science and Technology (SFWST) milestone M3SF-205N010303034, as part of the SNL "Salt Disposal R&D" work package.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transient voltage-reversal in transformers with multiple secondary coils

By using a transformer with multiple secondary coils, a single unipolar power source can drive multiple loads that have different steady-state operating-voltage requirements. We show that, during initial turn-on, a transient voltage that is opposite in sign to the operating voltage can be induced in one or more of the secondary coils. This is because the surging currents in the coils during turn-on produce a strong inductive interaction between all the coils. In a particular secondary coil, the voltage induced by a neighboring secondary can be larger, and opposite in sign to, the voltage directly induced by the primary coil. The effect is transient because, when the secondary circuits reach their steady-state operating currents, they no longer couple inductively to each other. We also show that, during the turn-on period, the voltage induced in a secondary coil can be significantly larger than its steady-state voltage. These transient effects are controlled by the values of the "coil-coupling" parameters, which are functions of the transformer geometry and of the magnetic permeability and electrical resistivity of the materials used. The results are derived from the circuit equations, and verified using PSpice simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Technology Development and Field Monitoring in nZEB - US Country report IEA HPT Annex 49 Task 3

The International Energy Agency (IEA) Heat Pumping Technologies (HPT) Annex 49, “Design and Integration of Heat Pumps for Nearly Zero Energy Buildings,” deals with the application of heat pumps (HPs) as a core component of the HVAC system for nearly or net-zero energy buildings. This report covers the Task 3 activities of the US team. Three institutions are involved on the US team and have worked on the following projects. 1) Oak Ridge National Laboratory (ORNL) summarized development activities since the conclusion of IEA HPT Annex 40 for several integrated HP (IHP) systems - electric ground-source IHP and air-source IHP versions and engine-driven AS-IHP version. 2) The University of Maryland partnered with ORNL and Blue Bear Management to develop a personal cooling device called RoCo that can provide personalized conditioned air to occupants in inadequately or unconditioned environments. With RoCo, building facility management can elevate the HVAC thermostat settings without compromising occupants’ thermal comfort. Researchers have found that a 4°F increase in thermostat settings can save 12–30% energy savings. Therefore, RoCo is a promising technology that can help reduce building energy consumption and facilitate achievement of net-zero energy building performance. 3) The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net-Zero Energy Residential Test Facility. Two air-source split-system HPs were installed in a residential, net-zero energy home that was constructed as a laboratory on the NIST campus in Gaithersburg, Maryland. The first HP was a two-stage, 7 kW (2 ton), 15.8 seasonal energy efficiency ratio (SEER), 9.05 heating seasonal performance factor (HSPF) conventionally ducted system; the second HP was a variable-speed, 10.6 kW (3 ton), 14 SEER, 8.35 HSPF, high-velocity ducted system. These two systems operated side by side, using separate supply ducts and a common return duct, on a weekly alternating schedule to condition the home that was operated with very consistent simulated thermal loads. The team wanted to determine whether the high-velocity system could provide comparable energy-use efficiency to the conventional system. The results of this study showed that it did meet the required loads and had slightly greater efficiency; the average cooling coefficient of performance (COP) was (0.40 ± 0.11) higher, and the average heating COP was statistically equal. A new firmware was provided at the end of the heating season that greatly improved the performance of the high-velocity system; its average heating COP went from (1.8 ± 0.9) to (2.5 ± 1.1) at a 95% confidence level. The new firmware heating COP averaged (1.05 ± 0.23) higher than the old firmware over the same outdoor temperatures. The defrost performance is very different for these two systems, yet they consumed equivalent energy per HDD. The conventional system uses a timed-initiate, temperature-terminate algorithm with auxiliary electric resistive heating, whereas the high-velocity system uses calculated evaporator parameters with a hot-gas bypass before a full reverse-cycle defrost with no supplementary resistive heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fast Computational Algorithms for Partial Differential Equations and Uncertainty Quantifications

This project concerned the construction, testing and analysis of computational algorithms for solving parameterized and stochastic partial differential equations. The study and understanding of equations of this type is of fundamental importance in numerous engineering and scientific applications. Examples include simulation of plasma dynamics in models of electric propulsion and nuclear fusion, simulation of multiphase flows, such as the flow of water, gas and oil in reservoirs, and structural analysis of the dependence of structures on materials. Parametrization is used in such settings when properties of the models such as viscosity of fluids or electric resistivity of materials are not precisely understood and instead are treated as random variables. The resulting solutions are themselves random, and having such solutions will enable engineers to use probabilistic methods to assess the likelihood of events, for example, whether a pollutant in a liquid will exceed a limit, and to use such analyses to develop ways to ensure positive outcomes. Construction of accurate (high resolution) computational solutions is expensive, requiring significant computer time and computational resources, and there is need to reduce computational cost to make simulation useful and effective. The aim of the project was to construct algorithms to efficiently compute surrogate solutions to parameterized problems to allow for efficient and accurate simulation. The technical approach used focused on two related strategies, based on rank-reduction methods and reduced-order models. These methods construct surrogate solutions of parameter-dependent models by projection or interpolation into low-dimensional approximation spaces. Cost savings are achieved if the low-dimensional spaces can be identified and constructed efficiently and if the resulting low-dimensional algebraic systems can be solved cheaply. Accomplishments include: Theoretical and empirical demonstration of the effectiveness of fast multigrid solution strategies for computing low-rank representations of parameter-dependent solutions to discrete partial differential equations, including the first proof establishing so-called textbook convergence properties for low-rank methods. Development of efficient solution algorithms for solving nonlinear parameter-dependent partial differential equations used in models of fluid dynamics. Developent of efficient algorithms for low-rank representation of solutions of time-dependent simulations of fluid dynamics using multi-dimensional tensor representations of solutions.

97 MATHEMATICS AND COMPUTING↗

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of a Potential Groundwater Tracer Test in the Ringold Upper Mud Aquifer at the 100-H Area of the Hanford Site

This document presents an evaluation of a potential groundwater tracer test in the uppermost RUM (Ringold Formation member of Wooded Island – upper mud unit) aquifer in the 100-H Area of the Hanford Site. The results from field electrical resistivity tomography (ERT) investigations, numerical flow and transport (F&T) modeling, coupled ERT-F&T model simulations, and laboratory resin experiments provide the technical basis for evaluating tracer test scenarios that minimize impacts to the 100-HX pump and treat (HX P&T) operations, and maximize hydrologic data acquisitions including the use of advanced surface geophysical techniques for monitoring tracer transport.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Damage Detection and Electrical Performance Impact of Flat-Flexible Circuits

Flat-flexible circuits or ‘flex circuits’ have varied applications in electronics and in explosive detonation systems. They pose advantages over conventional coaxial cables in their ability to fit into small mechanical envelopes and routings. A typical flex circuit is composed of a laminated assembly of multiple layers of conductor and dielectric materials. Copper, because of its high electrical conductivity, is one of the primary materials used in flex circuit conductors. The conductor must maintain structural integrity and electrical continuity when the flexible circuit is bent during processing or to fit an application envelope. Under some strain conditions a cable may have degraded electrical performance even though visible damage may not be evident. Dislocation density can increase by mechanisms such as dislocation forest hardening, where gliding dislocations in primary slip planes get pinned at obstacles and form Frank-Read sources. Dislocation density increases within the conductor layers may impact electrical resistivity but would not necessarily result in visible mechanical failure. In some detonation applications, such as for building implosion for demolition, the time for signal transmission and voltage used for firing detonators can be critical. If the resistance in a single flex cable within a building demolition array is too high, the resultant demolition shape may be asymmetric, leading to unplanned damage to nearby structures and potential hazards to public safety. This study will apply non-destructive evaluation techniques to evaluate the detectability of damage accumulation in flat, flexible copper-conductor cables and discuss potential implications to their practical use.

42 ENGINEERING↗

Continuous Particle Monitoring and Removal for Molten Chloride CSP Systems

This report describes the technologies that were developed as part of the Continuous Particle Monitoring and Removal for Molten Chloride CSP Systems project that was funded by the EERE Solar Energy Technologies Office during FY2021. This project consisted of two main tasks: (1) the development electrical resistance tomography (ERT) sensors to provide particle sensing capabilities for CSP-relevant molten chloride salts, and (2) the development of vortex separation technologies to enable efficient removal of particles from the salt. Both of these tasks are crucial because, although the Gen3 CSP chloride heat transfer fluid is inexpensive and can achieve high temperatures, major issues with erosion corrosion and clogging can arise from the presence of MgO particles within the salt. The particle monitoring and removal technologies were both demonstrated over the course of this project. The ERT sensors were able to achieve their performance targets by providing accurate particle concentration measurements over a range from 0.0 to 8.0 wt%. The vortex separators were able to demonstrate separation of particles from molten salt streams, but the separation efficiencies were lower than the targeted level of 90%. With further development and deployment, these technologies will ultimately help to enable successful long-term operations of CSP systems that make use of high-temperature chloride salts.

14 SOLAR ENERGY↗

Creation of Laboratory-scale Testbed for Autonomous Monitoring and Control of Subsurface Systems

This report describes the results of an LDRD project aiming to develop a laboratory-scale testbed for autonomous subsurface monitoring and control systems. Modifications were made to an existing polyaxial loading frame to incorporate electrical resistivity tomography (ERT) and acoustic emission (AE) monitoring systems. This allows engineered subsurface processes to be studied under realistic temperatures and stresses in a scaled-down laboratory environment with similar monitoring systems as are deployed in field-scale systems. The paper outlines some challenges that were faced in implementing the ERT system at the laboratory scale and the solutions that were devised. Results are shown from two demonstration tests—one focusing on the ERT system, and one focusing on the AE system.

42 ENGINEERING↗

Deep Learning At Depth: Estimating subsurface parameters from geophysical monitoring data

Geophysical imaging techniques are a non-invasive way to image the subsurface and understand both subsurface solid (rock/soil) and fluid property distributions and their evolution in time. Inversions of the geophysical data, such as Electrical Resistance Tomography (ERT) data, are solved to estimate the subsurface property distributions, such as conductivity, and many inversion techniques smooth out sharp gradients in rock or fluid property distributions. Sharp gradients in subsurface properties tend to be present in situations with complex subsurface structures, which are common in many subsurface applications. We have successfully demonstrated that it is possible to inform, or constrain, inversions with neural networks trained on synthetic data with complex subsurface structures. Initial results suggest this process may be optimizable to yield property distributions that better represent the true property distributions than the same inversion process without the neural network constraint. Future work would optimize the neural network performance for this application and then apply the synthetic-data trained neural network to real data to understand the utility and performance of this technique for real data sets.

47 OTHER INSTRUMENTATION↗

Field Validation of Innovative Air-Source Heat Pumps for Cold-Climate Heating Applications

Air-source heat pumps (ASHPs) have historically found application in milder climates in the United States (US). Their application in cold climates has been hindered by reduced performance as outdoor temperatures fall below freezing and the need for backup or auxiliary electric resistance heaters to meet peak heating loads. Recent advances in cold-climate air-source heat pumps (ccASHPs) with features such as variable-speed compressors, multistage systems, and highly optimized thermal design have improved performance by increasing the coefficient of performance (COP), low-ambient-temperature capacity, and heating seasonal performance factor (HSPF) dramatically. Despite their benefits, ccASHPs are still not widely prescribed for cold climate conditions. This is due in part to a lack of verified, demonstrated performance and analysis in cold climates. Ultimately, high-efficiency ccASHPs play a key role in emerging energy/grid renovation efforts in addition to their potential energy savings and avoided carbon emissions, but their actual performance in various cold climate field settings must be better understood. The primary objective of this project was to measure the in-field performance of variable-capacity air-source heat pumps in cold climates with the goal of enabling the development of field-based performance maps. Specifically, the study looked at how the heat pumps operated in the field, the frequency of cycling, the frequency of defrost events, and the time spent in each mode of operation. The results are intended to be used by DOE to inform research and development of energy-efficient equipment and to develop guidelines for optimizing primary energy savings when using air-source heat pumps in heating-dominated regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Qualification of Commercially Available Silicon Carbide for Passive Thermometry in Reactor Experiments – FY23 Status Report

Silicon carbide (SiC) is often used as a passive temperature indicator for uninstrumented in-core nuclear experiments. For the past several decades, Oak Ridge National Laboratory has relied primarily on SiC thermometry manufactured by Dow Chemical Company, formerly Rohm and Haas because of the material’s high density and reduced grain boundary elements. Although Dow SiC has performed well in this application, this material is no longer commercially available, and a new supplier is needed for future experiments. To determine a suitable replacement, a study was initiated on five types of SiC from four commercial vendors. Several critical properties, including density, electrical resistivity, chemical purity, grain structure, crystal structure, and strength were measured in samples from each material. Additionally, thermometry specimens were manufactured for irradiation in the High Flux Isotope Reactor at nominal temperatures of 300°C, 600°C, and 900°C, which will be measured using continuous dilatometry at a later date. This report provides an update of commercially available SiC material characterization and the irradiation capsule design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solar+Storage for Household Back-up Power: Implications of building efficiency, load flexibility, and electrification for backup during long-duration power interruptions [Slides]

The study analyzes the evolving role of solar+storage for home backup power during long-duration power interruptions. In particular, it evaluates how required storage sizing is impacted as homes become more efficient, flexible, and electrified. The study relies on NREL’s ResStock building modeling platform to create statistically representative distributions of the existing building stock in ten locations across the United States. It then shows how the amount battery storage required for backup power rises or falls as a series of building envelope efficiency, load flexibility, and electrification measures are applied across the building stock in each region. The study also includes sensitivities to show how backup power requirements are impacted by the timing and duration of power interruptions, and explores variation in backup power requirements across the building stock within each study location. The results demonstrate the value of pairing solar+storage with efficiency upgrades, smart home controls, and (in mild winter climates) efficient heat pump retrofits. That value comes in the form of reducing the amount of storage required and/or extending the range of interruption conditions over which a given system can provide backup power (i.e., more extreme weather and/or longer interruptions). Heat pumps in cold-weather climates can pose a challenge for solar+storage backup power, given the amount of storage required, though are a vast improvement over electric-resistance heating. Retaining existing fossil-based heating systems for occasional use during power interruptions, as either the primary or supplementary source of heat, can mitigate this challenge. Other forms of building electrification (e.g., cooking and water heating) generally have marginal impacts on backup battery sizing, given their relatively small energy demand.

14 SOLAR ENERGY↗

Evaluation of a CFD Commercial Package to the Modeling of Acoustic Wave Propagation in Bubbly-Liquid Column

This document reports on the considerations and development of an initial computational model based on the first principles for predicting acoustic propagation in a wellbore based on a logging-while-drilling (LWD) tool. This tool could be used to create a large database of simulated signals mimicking gas-influx-while-drilling events (so-called “kicks”). While other logging techniques, such as electrical resistivity and bulk density, are available in LWD tools, the acoustic logging method was identified in a complementary experimental endeavor as the most appropriate for early kick detection due to its high sensitivity to the presence of gas in liquids.

03 NATURAL GAS↗

End-Use Savings Shapes: Measure Documentation: Add Exhaust Air Heat/Energy Recovery

This documentation focuses on a single end-use savings shape measure—Add Exhaust Air Heat/Energy Recovery. This measure adds exhaust air energy recovery or heat recovery to existing air handling units (AHU) with outdoor air. Systems that already have energy/heat recovery are not modified. Furthermore, food service building types are also not modified by this measure due to the added complication of integrating cooking hood exhaust that could cause heat exchanger fouling from kitchen exhaust. In total, this measure is applicable airloops serving ~70% of the floor area in ComStock. In practice, energy/heat recovery systems are retrofitted to existing air delivery systems either as separate systems that provide outdoor air to the AHUs or are directly integrated to an AHU; the modeling approach used in this study is agnostic of the energy recovery type and simply accounts recovery effectiveness, added static pressure, and other controls which are described further in this document. Energy recovery with sensible and latent exchange gets added in humid climate zones, while heat recovery with sensible-only exchange gets added in drier climate zones. Energy recovery is modeled as a fixed membrane plate counterflow heat exchanger, while heat recovery is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and electric resistance preheat coil for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Geophysical Information to Investigate Subsurface Structure within the High-Hydraulic Conductivity Analysis Zone

Within the 200 East Area of the Central Plateau and southeastward toward the Columbia River, a high-hydraulic conductivity zone (HCZ) has been interpreted to extend through the 200-PO-1 and 200-BP-5 operable units on the Hanford Site. The HCZ is a controlling hydraulic feature that impacts groundwater flow out of the 200 East Area and the fate of eastwardly migrating plumes from the 200 West Area. The lateral extent of the HCZ is highly uncertain, and despite strong evidence for the existence of the HCZ based on water-level data and contaminant plume tracking, there is still a limited understanding of how to define its boundaries. To provide additional information on the nature and extent of the HCZ, three surface geophysical methods – electrical resistivity tomography (ERT), time-domain electromagnetics (TEM), and seismic methods – were used to collect data south of 200 East. In addition, existing data from 200 East, consisting of surface seismic data, a borehole check shot survey in 699-37-47A, and borehole stratigraphic interpretations, were used to aid interpretations of newly collected seismic data south of 200 East. This work presumed that the contrast in subsurface geophysical properties would be a first-order aid identifying a transmissive zone(s) within the HCZ analysis area by imaging contrasts and/or anomalies in geophysical properties. While seismic, ERT, and TEM methods have sensitivity to overlapping physical properties (porosity, moisture content, lithology), the resolution and physics used to acquire each of these datasets are different, and therefore the information can also be different. Figure S.1 shows the locations of the geophysical data considered in this report.

58 GEOSCIENCES↗