Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Accelerating Adoption of Energy-Efficient Technology with the Thermalize Model

The accelerating impacts of climate change destabilize food systems and ecosystems alongside the communities that rely on them. Thus, climate resilience is a health equity issue at both a physical (relating to biological impacts of pollution and environmental degradation) and a cultural level (loss of subsistence lifestyles, languages, etc). With roughly 20% of US energy-related greenhouse gas emissions stemming from heating, cooling, and powering households, accessible energy-efficient home retrofits are a critical element of climate change mitigation strategies. For communities already producing electricity from renewable sources, like Juneau, incentivizing ductless heat pump upgrades and energy efficiency retrofits provides an accessible pathway to transition households away from oil heating and drastically reduce emissions. Thermalize Juneau is a pilot program that will explore a repeatable framework for accelerating the adoption of energy-efficient technology in Alaska communities. This poster will describe Thermalize Juneau's goals and framework, progress through spring 2021, and future plans.

ductless heat pumps↗

Empirical Estimation of the Energy Impacts of Projects Installed through Residential Property Assessed Clean Energy Financing Programs in California

We examine the energy use impacts of energy efficiency and solar PV projects financed by residential property assessed clean energy (R-PACE) programs in California. We leverage household-level interval meter data to apply normalized metered energy consumption (NMEC) methods at significant scale—more than 25,000 electric meters and more than 15,000 gas meters. We develop a comparison group to account for non-project-related changes in usage. The projects include homes that replaced existing HVAC equipment with higher-efficiency units and homes that installed central heating or air conditioning equipment for the first time. We have limited information on pre-project household equipment stock so we develop a method to infer new installations. We find that projects that installed energy efficiency technologies reduce electricity consumption by approximately 3% and gas consumption by approximately 3.5% on average. When we remove homes that installed new cooling and heating equipment for the first time, savings rise to approximately 5% for electricity and approximately 6% for gas. Given the California climate and the results of an existing study of similar California projects, these results are in line with expectations. Solar PV projects produce electricity that offsets approximately 69% of household electricity consumption on average. We estimate that California R-PACE projects installed through the end of 2019 produce annual reductions in grid-tied electricity consumption of 506 GWh (equivalent to the electricity consumption of approximately 74,000 California households) and gas consumption reductions of 2 million therms (equivalent to the gas consumption of approximately 4700 California households) in a typical weather year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Electric Cooking Equipment

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past three years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. “Measures” refers to energy efficiency variables that can be applied to buildings during modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Console Water-to-Air Geothermal Heat Pump

Executive Summary Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past several years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. This measure models the conversion of an existing heating, ventilating, and air-conditioning (HVAC) system to a series of “console” water-to-air heat pumps served by a ground heat exchanger. Console water-to-air geothermal heat pumps (GHP) are all-in-one packages that have no or minimal ductwork and serve individual spaces. Properly designed ground heat exchanger-coupled systems can offer benefits in energy efficiency relative to “conventional” HVAC systems, as well as facilitating beneficial electrification. Console GHPs can be coupled to a ground loop on the source side and can directly replace electric baseboard heaters or air-source packaged terminal heat pumps. Console GHPs can also bring in outdoor air for ventilation. This measure will be referred to throughout the document as the “Console GHP” upgrade.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Climate-Water-Electricity Interactions in the U.S. Under Alternative Decarbonized Futures

The U.S. electric sector is rapidly evolving, with widespread renewable energy deployment, building and transport electrification, and nuanced decarbonization policies. Climate change influences the supply and demand for electricity by altering water resources for cooling and hydropower, thermal plant efficiencies, and heating and cooling demand. This research combines global climate model data, asset-level water and streamflow modeling, and electric sector capacity expansion modeling to study climate-water-electricity interactions across myriad future climate and electricity scenarios that consider electrification and decarbonization using renewable, hydrogen, carbon capture, and nuclear technologies. Multi-model integration leads to insights into power-water sector interactions and their impacts on grid economics and environmental outcomes.

climate change↗

Origin of enhanced water oxidation activity in an iridium single atom anchored on NiFe oxyhydroxide catalyst

The efficiency of the synthesis of renewable fuels and feedstocks from electrical sources is limited, at present, by the sluggish water oxidation reaction. Single-atom catalysts (SACs) with a controllable coordination environment and exceptional atom utilization efficiency open new paradigms toward designing high-performance water oxidation catalysts. Here, using operando X-ray absorption spectroscopy measurements with calculations of spectra and electrochemical activity, we demonstrate that the origin of water oxidation activity of IrNiFe SACs is the presence of highly oxidized Ir single atom (Ir 5.3+ ) in the NiFe oxyhydroxide under operating conditions. We show that the optimal water oxidation catalyst could be achieved by systematically increasing the oxidation state and modulating the coordination environment of the Ir active sites anchored atop the NiFe oxyhydroxide layers. Based on the proposed mechanism, we have successfully anchored Ir single-atom sites on NiFe oxyhydroxides (Ir 0.1 /Ni 9 Fe SAC) via a unique in situ cryogenic–photochemical reduction method that delivers an overpotential of 183 mV at 10 mA · cm – 2 and retains its performance following 100 h of operation in 1 M KOH electrolyte, outperforming the reported catalysts and the commercial IrO 2 catalysts. These findings open the avenue toward an atomic-level understanding of the oxygen evolution of catalytic centers under in operando conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interdigitated electrode geometry variation and external quantum efficiency of GaN/AlGaN-based metal-semiconductor-metal UV photodetectors

Aluminum gallium-nitride (Al x Ga 1–x N)-based metal–semiconductor–metal (MSM) ultraviolet photodetectors photodetectors (PD’s) have been successfully designed and fabricated using conventional photolithography techniques and tested experimentally to study their spectral sensitivity across different Al content, x, with x varying from 0 to 0.3. (Al)GaN-based UV PD’s have wide and tunable direct band gaps. The ability to easily select the photodetected wavelength by simply varying the aluminum content of GaN thin film (Al x Ga 1–x N) is a significant advantage of these group III–V compounds. Typically, MSM PD’s grown on (Al)GaN thin films result in ultrafast photodetection because of their highly mobile carriers. These devices are limited by the carrier transit time due to the negligible capacitance presented by the interdigitated fingers. Various electrode geometries were fabricated to investigate the influence of metal contact shapes on the devices’ performance indices with emphasis on the response speed and bias-voltage–independent efficiency. Here, coupled with the independently measured Hall mobility and electric field, we computed the carrier transit time of the devices to be as short as 1.31 ps and the bias-voltage–independent external quantum efficiencies were as high as 70% at 60 V for n-doped and intrinsic devices when operated in the reverse bias regime. Here, (Al x )Ga 1–x N photodetectors were designed to explore spectral sensitivity by altering x from 0 to 0.3.

42 ENGINEERING↗

South Texas Industrial Assessment Center (Final Report)

The South Texas Industrial Assessment Center (ST-IAC) provides small to mid-size manufacturing companies and water treatment plants in the Rio Grande Valley of Texas, free energy assessments to help them reduce costs and stay competitive for sustainable development. The ST-IAC operates within the University of Texas Rio Grande Valley (UTRGV), and is the largest Hispanic-serving IAC in the U.S. Created in 2016, the ST-IAC, situated in the most economically disadvantaged region in the country, has been successful in training students and assessing local industries served by a predominantly Hispanic population. UTRGV, now the second largest Hispanic Serving Institution (HSI) of higher education in the U.S., has a student population of 32,000, of which 90% is Hispanic. While Covid-19 had a negative impact to our program during Budget Periods (BP) 4 and 5, the center still managed to provide opportunities for individuals, manufacturing and water industries in the local region. The program developed an energy engineering program in the region and further advanced national priorities. Those include resilience and sustainability of operations by implementing energy efficiency processes, renewable energy sources, decarbonization, battery storage, and cybersecurity in south Texas.

14 SOLAR ENERGY↗

AOI.1 Application of Artificial Intelligence techniques enabling coal fired power plants the ability to achieve higher efficiency, improved availability, and increased reliability of their operations (Final Report)

During this effort, SparkCognition with support from the Electric Power Research Institute (EPRI) was tasked with applying artificial intelligence (AI) to improve the reliability, efficiency, and safety of operations at a coal-fired plant. By implementing AI techniques, like machine learning (ML), it is believed that operators can leverage existing data sources to gain more insights such as advanced warning of machine degradation. With enough lead time, a reliability engineer can take action to minimize, or even avoid, impact to production. To complete this work effort, SparkCognition developed and refined an ML-based model using sensor data for a Steam Turbine unit at a host site. The models were deployed in an online, web-based solution that allows users to visualize model outputs and supporting data. The final solution, based on SparkCognition’s proprietary software platform called SparkPredict®, was shared with EPRI who completed an online evaluation of results to determine the solution’s ability to detect actionable events.

20 FOSSIL-FUELED POWER PLANTS↗

Incorporating Valve Switching Losses Into a Static Optimal Control Algorithm for the Hybrid Hydraulic-Electric Architecture (HHEA)

The Hybrid Hydraulic-Electric Architecture (HHEA) has, in recent years, been proposed as an energy efficient alternative to conventional load-sensing architectures in mobile machines such as excavators and wheel-loaders. HHEA leverages the advantages of hydraulic power and electric power to eliminate throttling valves while also improving the energy and control performance of the system. The architecture utilizes a set of common pressure rails to provide a majority of power and and a small electric motor driven pump to modulate this power to meet the exact demand. Previous work has developed a computationally efficient Lagrange Multiplier approach for determining the optimal pressure rail selections that minimizes the energy losses in the system. The static model used considers only the energy use for each pressure rail selection but not the losses associated with the valves during the transition. This paper presents an approach to include the switching losses in the model and in the optimization procedure. To capture the switching losses, switching events between different rails and at various input and output flow rates were simulated with consideration of valve spool dynamics. A parameterized model that summarizes the losses is then obtained, allowing switching losses to be added to the previous energy analysis. The performance of the switching loss model was compared with reference data obtained from a high-fidelity simulation model. To incorporate the switching losses into optimal control algorithm, an efficient dynamic programming approach that prevents frequent switching is adopted in place of the Lagrange multiplier approach. The overall effect of switching losses on the energy consumption and optimal control decisions is presented. In general, switching losses contribute to about 9–10% of input energy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exploring impacts of electricity tariff on charging infrastructure planning: An activity-based approach

In the past decade, electric vehicles (EVs) have gained popularity for their efficiency and environmental benefits. Advances in battery technology and charging equipment have yielded long-range EVs and fast-charging. However, many major cities lack adequate charging infrastructure for daily EV use. This study addresses this gap by integrating activity-based modeling, charging behavior simulation, and charging infrastructure optimization. The research utilizes the POLARIS agent-based transportation model to accurately capture user activities, trip patterns, and traffic flows. Additionally, the study investigates the impact of fixed and spatiotemporal electricity rate distributions on optimal charging infrastructure deployment. The framework is applied to the Chicago regional area network and analyzed under various EV ownership scenarios. Further, the results reveal significant impacts of the charging pricing strategy on user decision-making and charging demand distribution. There is also a need for consistent pricing policies in charging infrastructure planning and operational phases to avoid drops in service quality.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Airport Ground Support Equipment Infrastructure & Logistics Electrification Assessment Tool: 2025 Data Development, Modeling and Analysis for DFW

The aviation industry is increasingly turning to modernize freight facilities by integrating electric Ground Support Equipment (eGSE) to enhance operational efficiency of freight facility moving vehicles and equipment. Airports worldwide are adopting eGSE to streamline cargo movement, reduce fuel and maintenance costs, and improve logistics coordination.1 North America, with its advanced aviation infrastructure, leads this transition, leveraging Internet of things (IoT)-enabled automation and zero emission technologies to boost reliability and reduce human errors.2 Electrification of freight facility moving vehicles and equipment boosts turnaround times, improves equipment reliability, and optimizes logistics coordination, giving operators a competitive advantage. With rising fuel price volatility and the pressure to meet stringent performance benchmarks, airports are focusing on cost-effective, scalable solutions for long-term financial and operational gains. To further accelerate electrification, airports are integrating Zero Emission Vehicles (ZEVs) into rental car fleets and deploying electric baggage carts, requiring strategic investments in charging infrastructure. 3 The shift, however, presents challenges, such as limited technical expertise, high capital costs, and complex procurement processes. By forging strategic partnerships, leveraging advanced technologies, and optimizing infrastructure investments, airports can create a resilient, future-ready ecosystem that enhances the movement of people and goods through electrification-driven efficiency. Supported by the U.S. Department of Energy (DOE) Vehicle Technologies Office (VTO), this electrification effort provides a scalable, cost-effective solution to improve airport freight operations. Through targeted investments and innovation, airports enhance efficiency, reduce costs, and meet performance benchmarks while advancing toward a resilient, electrified future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Debate on Vehicle Triad: Examining the Utilization Patterns of Gasoline, Hybrid, and Electric Vehicles in Households

Light-duty vehicles contribute to approximately half of the transport sector's emissions, a sector challenging to decarbonize owing to the autocentric nature of many American cities. The U.S. Department of Transportation's blueprint outlines three key decarbonization strategies: increasing convenience, improving efficiency, and transitioning to zero-emission vehicles. Among these, the adoption of Electric Vehicles (EVs) offers a promising opportunity to reduce emissions from light-duty vehicles, which are predominantly gasoline-powered. Although substantial literature identifies and addresses factors influencing EV adoption, understanding their utilization within households who own vehicles with mixed fuel types is crucial for accurately assessing their environmental benefits. This paper addresses two key questions: (a) Are EVs utilized more, equally, or less than gasoline vehicles (GVs) and (b) What factors influence mileage utilization patterns in households with multiple vehicle fuel types, accounting for substitution and complementary effects? Analysis of 2022 National Household Travel Survey (NHTS) data indicates that EVs are utilized more than GVs within households that own multiple mixed fuel fleets. Findings reveal that households with a higher number of younger individuals and multiple workers use EVs more extensively, and those with older adults and larger households with multiple vehicles tend to use GVs more. Rural households have higher use of hybrid vehicles (HVs). The study identifies a substitution effect between EVs and GVs, while complementary relationship between HVs and EVs, suggesting nuances in vehicle utilization patterns. This nuanced understanding of vehicle utilization patterns informs the development of targeted policies and infrastructure investments to optimize household transportation efficiency.

ADVANCED PROPULSION SYSTEMS↗

Research Priorities and Opportunities in U.S. Wholesale Electricity Markets: Market Design under Deep Decarbonization

This report contributes to the body of literature by reviewing key challenges for competitive wholesale electricity market design in deeply decarbonized power systems and establishing potential solutions and associated research needs. We provide a long-term perspective on ways in which competitive wholesale electricity markets can evolve to ensure that they still operate efficiently throughout the transition to a deeply decarbonized future. In this report, we use the term “deep decarbonization” to refer broadly to systems that generate nearly all their electricity from zero-carbon or carbon-neutral resources, while recognizing that there are many potential configurations of such systems. We also stress that many of these issues will arise to varying degrees as systems move toward full decarbonization, even if they are not truly 100% carbon-free.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Efficient Reformulation and Optimization for SC-ACOPF with Line Switching

This project aims to develop efficient and robust computational methods for solving the security-constrained alternating current optimal power flow problem (SC-ACOPF). The SC-ACOPF problem is a central problem in operating the electric power grids in the United States. It determines the most economically efficient way to operate the generation and transmission system to meet daily electricity demand. The solution found by solving an SC-ACOPF problem must satisfy the physics of the alternating current (AC) power flows, various generator and network operational constraints, and must maintain secure operation under various contingency scenarios, where a generator, a transmission branch, or a transformer may unexpectedly trip offline.

97 MATHEMATICS AND COMPUTING↗

Tin–Lead Alloying for Efficient and Stable All-Inorganic Perovskite Solar Cells

Cesium containing all-inorganic perovskites have received considerable interest in photovoltaics research because of their potential for improved stability compared to their organic-inorganic hybrid counterparts. However, the inorganic perovskites studied thus far still suffer from lower power conversion efficiency and long-term instability, due to an unfavorable bandgap and either phase instability or air-sensitivity. Herein, A strategy to mitigate these concerns is investigated by alloying tin and lead on the B site to form tin-lead alloyed low-bandgap (~1.34 eV) inorganic CsSn 0.3 Pb 0.7 I 3 perovskites. Solar cells made using this material in an inverted full-structured architecture with a PEDOT:PSS hole transport materials (HTM) attain power conversion efficiency (PCE) up to 9.41% (stabilized PCE 7.23%). Furthermore, a simple HTM-free device without PEDOT:PSS layer is demonstrated more stable than the full-structured device and exhibits a PCE of 7.60% (stabilized PCE 7.31%) – the highest efficiency to date for an inorganic perovskite with a bandgap below 1.40 eV. This simplified device structure shows good reproducibility and stability. Finally, this work provides a possible route for fabricating low-cost, high stability devices with competitive efficiencies.

14 SOLAR ENERGY↗

The Transactive Energy Network Template Metamodel

While transactive energy, which is defined as an allocation of electricity based on dynamically discovered values or prices, has been extensively studied, its uptake and use has been slow. This report describes a tool, the transactive network template, which should hasten the creation and uptake of transactive energy networks. Some basic principles of transactive energy are familiar from existing wholesale electricity markets. Locational prices are calculated today for zones within bulk electric transmission systems. Locational prices differ while accounting for the locational costs of electricity generation and the losses and constraints incurred when electricity is transmitted from generators and distributed to consumers. A transactive energy network might include these transmission zones. However, current research strives to apply transactive energy also in electricity distribution circuits, buildings, and even for individual generating and consuming devices. At the same time, researchers explore how to apply transactive energy in real time during increasingly shorter time intervals. Automated computational agents become necessary as transactive energy becomes applied to smaller circuit zones and at faster dynamic timescales. A transactive energy network is an example of a multi-agent system. Each zone in the network is represented by its transactive agent, which makes decisions for and acts on behalf of a business entity that is responsible for and manages one of the circuit regions. A transactive energy network is also an example of a decentralized, distributed control system. Control decisions and responsibilities are distributed among the network’s transactive agents. The transactive agents are independent; that is, there typically is no centralized authority or oversight function. Instead, transactive agents exchange transactive signals and thereby negotiate the prices and quantities of electricity that they will exchange. Initially, the circuit regions and responsibilities of transactive agents appear to be very dissimilar. Each circuit region may comprise transmission, distribution, or building-level circuits. Each has a unique position and electrical connectivity within the transactive energy network. Each possesses unique assets that either generate or consume electricity, and these (e.g., renewable energy generator, diesel generator, aggregate utility load, building load, space conditioning, refrigerator, etc.) may further differ in their price flexibility and in their strategies for responding to dynamic electricity prices. Given such diversity, an implementer’s first inclination might be to start from scratch to define all these devices and to engineer their seemingly unique interactions. Given that each implementer’s perspective may be narrow within a transactive energy network, it is unlikely that uniquely engineered systems would interact well. This is where the transactive network template is applicable. The transactive network template is a metamodel that has been developed to guide implementers as they configure their own transactive agent within a network of such agents. The object-oriented design of the transactive network template provides basic code object types that may be used and extended by implementers to represent each of the assets in their circuit region. These objects further facilitate the transactive agent’s necessary computations, which are divided among responsibilities to schedule power usage, balance electric supply and demand, and coordinate the exchange of electricity with the other transactive agents. This report addresses the conceptual transactive network template design. Implementers are directed to more formal design documents and reference implementations. A Python™-based1 reference implementation of the transactive network template has been coded, and three implementations have been configured to represent a national laboratory and two university campuses. Version 2 of the transactive node template generalizes the market class and its methods to facilitate multiple, and more diverse market coordination mechanisms than were facilitated by and demonstrated using Version 1. Version 3 includes new Appendix B, which addresses the designs of methods that would make dynamic prices track approved electricity rates. In the future, the author wishes to make the transactive network template more generally applicable to networks that require more accurate power flow. Development of the transactive network template is jointly funded by the U.S. Department of Energy (DOE) Energy Efficiency and Renewable Energy and the DOE Office of Electricity. In late 2015, one of the first projects to be funded by the DOE Grid Laboratory Modernization Laboratory Consortium was the Clean Energy and Transactive Campus project, led by Pacific Northwest National Laboratory. DOE funds were matched by an investment by the Washington Department of Commerce through its Clean Energy Fund. The transactive network template was developed to guide the implementation of transactive energy networks within this project’s scope.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Informing electrification strategies of residential neighborhoods with urban building energy modeling

Electrifying end uses is a key strategy to reducing GHG emissions in buildings. However, it may increase peak electricity demand that triggers the need to upgrade the existing power distribution system, leading to delays in electrification and needs of significant investment. There is also concern that building electrification may cause an increase of energy costs, leading to further energy burden for low-income communities. This study uses the urban scale building modeling tool CityBES to assess the electrification impacts of more than 43,000 residential buildings in a neighborhood of Portland, Oregon, USA. Energy efficiency upgrades were investigated on their potential to mitigate the increase of peak electricity demand and energy burden. Simulation results from the calibrated EnergyPlus models show that electrification with heat pumps for space heating and cooling as well as for domestic water heating can reduce CO2e emissions by 38%, but increase peak electricity demand by about 9% from the baseline building stock. Combining electrification measures and energy efficiency upgrades can reduce CO2e emissions by 48% while reducing peak electricity demand by 6% and saving the median household energy costs by 28%. City and utility decision makers should consider integrating energy efficiency upgrades with electrification measures as an effective residential building electrification strategy, which significantly reduces carbon emissions, caps or even decreases peak demand while reducing energy burden of residents.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗