Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Corruption of radio metric Doppler due to solar plasma dynamics: S/X dual-frequency Doppler calibration for these effects

Doppler data from Mariner 6, 7, 9, and 10 and Pioneer 10 and 11 were discussed and the rms noise level for various sun-earth-probe angles were shown. The noise levels of both S- and X-band Doppler data for sun-earth-probe angles smaller than 20 deg were observed to be orders of magnitude greater than nominal. Such solar plasma-related Doppler degradation reduced the Mariner 10-Mercury 11 encounter navigation accuracy by nearly a factor of 10. Furthermore, this degradation was shown to be indirectly related to plasma dynamics and not a direct measure of the dynamics.

Winn, F. B.↗

Experimental and analytical study on the flutter and gust response characteristics of a torsion-free-wing airplane model

Experimental data and correlative analytical results on the flutter and gust response characteristics of a torsion-free-wing (TFW) fighter airplane model are presented. TFW consists of a combined wing/boom/canard surface and was tested with the TFW free to pivot in pitch and with the TFW locked to the fuselage. Flutter and gust response characteristics were measured in the Langley Transonic Dynamics Tunnel with the complete airplane model mounted on a cable mount system that provided a near free flying condition. Although the lowest flutter dynamic pressure was measured for the wing free configuration, it was only about 20 deg less than that for the wing locked configuration. However, no appreciable alleviation of the gust response was measured by freeing the wing.

Murphy, A. C.↗

Orbit Determination System for Low Earth Orbit Satellites

The IAI/MBT Precise Orbit Determination system for Low Earth Orbit satellites is presented. The system is based on GPS pesudorange and carrier phase measurements and implements the Reduced Dynamics method. The GPS measurements model, the dynamic model, and the least squares orbit determination are discussed. Results are shown for data from the CHAMP satellite and for simulated data from the ROKAR GPS receiver. In both cases the one sigma 3D position and velocity accuracy is about 0.2 m and 0.5 mm/sec respectively.

Elisha, Yossi↗

Experimental measurements of the rotating frequencies and mode shapes of a full scale helicopter rotor in a vacuum and correlations with calculated results

This paper presents results of an experimental program conducted to obtain data which can be used for correlations of rotor blade dynamic analyses. Measurements were made of the rotating frequencies and mode shapes of a representative full-scale, two-bladed helicopter rotor in a vacuum. The blades were cantilevered to the hub. Mode shape data were obtained optically using a system of cameras developed specifically for this purpose. Excitation of the rotor was provided by vertical oscillatory motion of the hub. To compare experimental and analytical results, correlations of some experimental measurements with calculations from an existing blade modes computer program based on a Holzer-Myklestad procedure are presented, and the differences between the results are discussed. The experimental and analytical natural frequencies were generally in good agreement as were the principal components of the modal deflections for the flap and lag modes. The torsion mode shape indicated disagreement between the measured and calculated results in regard to the amount of flap and lag motions present in this mode, while the spanwise variations of the measured and calculated torsional components were in agreement.

Lee, B. L.↗

The right conditions for high-precision dynamic temperature and heat capacity measurement via pyrometry and conductivity

The pursuit of accurate bulk temperature T under extreme conditions has been a long-standing goal of the high pressure science community, complicated by a lack of data to inform models. To reach these extremely high-pressure, high-temperature (high P − T) conditions, a combination of dynamic and heated static experiments (e.g., diamond or gem anvil cel experiments) are used. For example, in a diamond anvil cell (DAC) experiment, a sample placed in the DAC is first pressurized. Following pressurization, the sample T is increased either by heating the entire DAC (usually using resistive heating, and limited to ∼1000K) or by applying intense laser power to the sample surfaces. In a dynamic experiment, the process of pressurizing the sample also heats it. In the case of shock physics experiments, such heating is substantial, easily reaching thousands of Kelvin; in our work we have seen T ∼17000K. Most methods of measuring temperature at ambient are not compatible with experiments under these high-pressure, high-temperature conditions: thermocouples break, melt, or have conductivity properties that differ from ambient where they are calibrated; thermometers would melt; both are too slow. As a result most methods are based on non-contact techniques such as x-ray diffraction broadening, neutron scattering, or optical methods. Of these, optical methods using the visible and near-infrared region of the spectrum are the most commonly used as the sources and detectors are readily available. In the case of optical methods the optical depth, and therefore the measurement location, is limited to the surface. When a window or anvil material is used, heat flows from the sample into the window/anvil. Likewise, if the sample undergoes a change in thermodynamic state, such as expansion upon release, different T may be expected. As a result, the surface or apparent temperature T app measurement will differ from the bulk or interior temperature that is desired. This surface measurement must be related to the bulk measurement using thermal transport models and material models. While it is tempting to conclude that one should just use x-ray methods that directly probe the interior, even these methods have been shown to depend on thermal transport and material models. Regardless of the method used to create the high P − T condition, therefore, we must understand the role of thermal transport and material models upon our interpretation of the T measurement, as well as the errors and uncertainties associated with the choice of models used in the analysis. This is a substantial area of research and this paper is by no means a complete survey of the relevant sources of uncertainty. For example, we have yet to begin to address alternate transport models in a detailed manner (e.g., Tan-Ahrens), or the many models that use additional layers to approximate melting, turbulence, or epitaxial phenomena). Likewise, we have not explored the impact upon uncertainty of thermal models that use temperature-dependent thermal transport coefficients, or the wide range of material models that can be applied. Instead, this paper focuses on using one simple model, the Urtiew-Grover model, to understand the sources of error in T measurement so that we may identify how best to focus future research efforts to return the best improvements and avoid working on over-optimizing a single type of measurement. To this end, we work through some of the best and worst case scenarios for T measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Volatile propellant droplet evaporation measurements in metered dose inhaler sprays

Many aerosol products rely on the rapid vaporization of volatile propellants to produce a fine spray. In the simplest case, these are binary mixtures of propellant and a delivered product which undergo a flash-evaporation process leaving only the less volatile product in the resultant droplet. In more complex applications, such as pressurized metered-dose inhalers, the non-propellant component may contain dissolved or suspended drug which precipitates or dries to form a matured particle. The size and morphology of the particles depend strongly on the time-history of the droplet as the propellant evaporates. However, measuring the dynamic evaporation processes that occur in dense sprays containing millions of droplets is challenging. In this paper, we demonstrate a novel application of Ultra Small Angle X-ray Scattering to measure the bulk composition of volatile HFC134a–ethanol sprays and compare the obtained results with simple evaporation models in a dry nitrogen environment. The data reveal that diffusion-limiting processes inside the droplet are equally important as external convection and mixing-limited factors in determining evaporative timescales.

42 ENGINEERING↗

Transonic flow about a thick circular-arc airfoil

An experimental and theoretical study of transonic flow over a thick airfoil, prompted by a need for adequately documented experiments that could provide rigorous verification of viscous flow simulation computer codes, is reported. Special attention is given to the shock-induced separation phenomenon in the turbulent regime. Measurements presented include surface pressures, streamline and flow separation patterns, and shadowgraphs. For a limited range of free-stream Mach numbers the airfoil flow field is found to be unsteady. Dynamic pressure measurements and high-speed shadowgraph movies were taken to investigate this phenomenon. Comparisons of experimentally determined and numerically simulated steady flows using a new viscous-turbulent code are also included. The comparisons show the importance of including an accurate turbulence model. When the shock-boundary layer interaction is weak the turbulence model employed appears adequate, but when the interaction is strong, and extensive regions of separation are present, the model is inadequate and needs further development.

Mcdevitt, J. B.↗

High sensitivity pump–probe measurements of magnetic, thermal, and acoustic phenomena with a spectrally tunable oscillator

We describe an optical pump/probe system for sensitive measurements of time-resolved optical measurements of material dynamics. The instrument design is optimized for time-resolved magneto-optic Kerr effect (TR-MOKE) measurements of dynamics in magnetic materials. The system also allows for time-domain thermoreflectance (TDTR) measurements of thermal transport properties and picosecond acoustic measurements of film thickness and/or elastic constants. The system has several advantages over the conventional designs for TRMOKE and/or TDTR systems. Measurements of pump-induced changes to the probe beam intensity are shot-noise limited. The system’s design allows for MOKE and/or thermoreflectance measurements of both sides of a sample. Pumping and probing the sample on opposite sides allows nanoscale flash diffusivity measurements of transport properties. The wavelengths of the pump and probe beams are straightforward to tune between 350–525 nm and 690–1050 nm. A tunable wavelength allows for optical resonances in a wide array of materials to be excited and/or probed. Finally, the setup is calibrated to allow for the real and imaginary components of Kerr signals to be separately quantified.

47 OTHER INSTRUMENTATION↗

Survey of Primary Flow Measurement Parameters at the NASA Langley Transonic Dynamics Tunnel

An assessment of the methods and locations used to measure the primary flow conditions in the NASA Langley Transonic Dynamics Tunnel was conducted during calibration activities following the facility conversion from a Freon-12 heavy-gas test medium to R-134a. A survey of stagnation pressure, plenum static pressure, and stagnation temperature was undertaken at many pertinent locations in the settling chamber, plenum, and contraction section of the wind tunnel and these measurements were compared to those of the existing primary flow measurement systems. Local flow velocities were measured in the settling chamber using a pitot probe. Results illustrate that small discrepancies exist between measured primary tunnel flow conditions and the survey measurements. These discrepancies in tunnel stagnation pressure, plenum pressure, and stagnation temperature were found to be approximately +/- 1-3 psf and 2-3 degrees Fahrenheit. The propagation of known instrument errors in measured primary flow conditions and its impact on tunnel Mach number, dynamic pressure, flow velocity, and Reynolds number have been investigated analytically and shown to require careful attention when considering the uncertainty in measured test section conditions.

Piatak, David J.↗

An Investigation of the Effect of Downwash from a VTOL Aircraft and a Helicopter in the Ground Environment

Dynamic-pressure measurement, in ground effect, have been obtained about a single-rotor helicopter and a dual-propeller VTOL (Vertical Take-Off and Landing) aircraft. The results indicate that the slipstream dynamic pressure along the ground, some distance from the center of rotation, is not a function of disk loading but merely a function of the gross weight or thrust of the aircraft. Furthermore, for a given gross weight the thickness of this outward flowing sheet of air is less for a small-diameter propeller (higher disk loading propeller). The variation of the dynamic-pressure flow field for single and dual propellers or rotors is significantly different in the plane of symmetry between the two rotors than in a direction normal to this plane. The interaction of the two flows produces a region of upflow in this plane where the fuselage is located, and the decay of the maximum dynamic pressure with distance ahead of the fuselage is slower.

O'Bryan, Thomas C.↗

Performance Evaluation of a High Bandwidth Liquid Fuel Modulation Valve for Active Combustion Control

At the NASA Glenn Research Center, a characterization rig was designed and constructed for the purpose of evaluating high bandwidth liquid fuel modulation devices to determine their suitability for active combustion control research. Incorporated into the rig s design are features that approximate conditions similar to those that would be encountered by a candidate device if it were installed on an actual combustion research rig. The characterized dynamic performance measures obtained through testing in the rig are planned to be accurate indicators of expected performance in an actual combustion testing environment. To evaluate how well the characterization rig predicts fuel modulator dynamic performance, characterization rig data was compared with performance data for a fuel modulator candidate when the candidate was in operation during combustion testing. Specifically, the nominal and off-nominal performance data for a magnetostrictive-actuated proportional fuel modulation valve is described. Valve performance data were collected with the characterization rig configured to emulate two different combustion rig fuel feed systems. Fuel mass flows and pressures, fuel feed line lengths, and fuel injector orifice size was approximated in the characterization rig. Valve performance data were also collected with the valve modulating the fuel into the two combustor rigs. Comparison of the predicted and actual valve performance data show that when the valve is operated near its design condition the characterization rig can appropriately predict the installed performance of the valve. Improvements to the characterization rig and accompanying modeling activities are underway to more accurately predict performance, especially for the devices under development to modulate fuel into the much smaller fuel injectors anticipated in future lean-burning low-emissions aircraft engine combustors.

Saus, Joseph R.↗

Hydrogen density measurements using an open-ended microwave cavity.

The density measurement of liquid hydrogen and two-phase mixtures of liquid and gaseous hydrogen is considered. This paper describes a complete prototype system that uses an open-ended microwave cavity for making dynamic density measurements of flowing hydrogen in a transfer line. The theory of operation along with test results for both the single- and two-phase cases are presented and discussed.

Wenger, N. C.↗

Dynamics of graphite fiber intercalation: In situ resistivity measurements with a four point probe

The dynamics of ferric chloride intercalation of single graphite fibers were studied, in situ, using a four point dc bridge. Measurements before, during and after the intercalation showed that the intercalation occurred within minutes at 200 C. Changes in fiber resistivity after exposure to air suggested hydration of the graphite intercalation compound. Deintercalation of the ferric chloride was initiated at temperatures in excess of 400 C. cycling the intercalant into and out of the graphite fiber gave no improvements in fiber resistivity. The activation energy of the ferric chloride intercalation reaction was found to be 17 + or - 4 kcal/mol 1 consistent with the concept of a preliminary nucleation step in the intercalation reaction.

Jaworske, D. A.↗

Efficient prediction of attosecond two-colour pulses from an X-ray free-electron laser with machine learning

Abstract X-ray free-electron lasers are sources of coherent, high-intensity X-rays with numerous applications in ultra-fast measurements and dynamic structural imaging. Due to the stochastic nature of the self-amplified spontaneous emission process and the difficulty in controlling injection of electrons, output pulses exhibit significant noise and limited temporal coherence. Standard measurement techniques used for characterizing two-coloured X-ray pulses are challenging, as they are either invasive or diagnostically expensive. In this work, we employ machine learning methods such as neural networks and decision trees to predict the central photon energies of pairs of attosecond fundamental and second harmonic pulses using parameters that are easily recorded at the high-repetition rate of a single shot. Using real experimental data, we apply a detailed feature analysis on the input parameters while optimizing the training time of the machine learning methods. Our predictive models are able to make predictions of central photon energy for one of the pulses without measuring the other pulse, thereby leveraging the use of the spectrometer without having to extend its detection window. We anticipate applications in X-ray spectroscopy using XFELs, such as in time-resolved X-ray absorption and photoemission spectroscopy, where improved measurement of input spectra will lead to better experimental outcomes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pore Distortion in a Metal–Organic Framework for Regulated Separation of Propane and Propylene

The development of porous solids for adsorptive separation of propylene and propane remains an important and challenging line of research. State-of-the-art sorbent materials often suffer from the trade-off between adsorption capacity and selectivity. Here, we report the regulated separation of propylene and propane in a metal–organic framework via designed pore distortion. Here, the distorted pore structure of HIAM-301 successfully excludes propane and thus achieved simultaneously high selectivity (>150) and large capacity (~3.2 mmol/g) of propylene at 298 K and 1 bar. Dynamic breakthrough measurements validated the excellent separation of propane and propylene. In situ neutron powder diffraction and inelastic neutron scattering revealed the binding domains of adsorbed propylene molecules in HIAM-301 as well as host–guest interaction dynamics. This study presents a new benchmark for the adsorptive separation of propylene and propane.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative x-ray scattering of free molecules

Advances in x-ray free electron lasers have made ultrafast scattering a powerful method for investigating molecular reaction kinetics and dynamics. Accurate measurement of the ground-state, static scattering signals of the reacting molecules is pivotal for these pump-probe x-ray scattering experiments as they are the cornerstone for interpreting the observed structural dynamics. Here, this article presents a data calibration procedure, designed for gas-phase x-ray scattering experiments conducted at the Linac Coherent Light Source x-ray Free-Electron Laser at SLAC National Accelerator Laboratory, that makes it possible to derive a quantitative dependence of the scattering signal on the scattering vector. A self-calibration algorithm that optimizes the detector position without reference to a computed pattern is introduced. Angle-of-scattering corrections that account for several small experimental non-idealities are reported. Their implementation leads to near quantitative agreement with theoretical scattering patterns calculated with ab-initio methods as illustrated for two x-ray photon energies and several molecular test systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

NASA’s Geospace Dynamics Constellation—Providing the first Systematic Measurements of Global Magnetospheric Energy Inputs and Ionosphere-Thermosphere Responses

The Geospace Dynamics Constellation (GDC) is NASA's next strategic Living With a Star mission. GDC's goals are: 1) Understand how the high-latitude ionosphere-thermosphere system responds to variable solar wind/magnetosphere forcing; and 2) Understand how internal processes in the global ionosphere-thermosphere system redistribute mass, momentum, and energy. Planned for launch by the end of the decade, GDC will use six identical observatories, each identically instrumented to fully characterize the magnetospheric drivers of the I-T system as well as the global response of the ionized and neutral gases. GDC will do this with a series of orbital configurations that will enable it to study the widest range of spatial and temporal scales to date, ranging from hundreds of kilometers and several seconds to tens of minutes, and extending through the regional to the global scale. This talk presents GDC's current status, measurement capabilities, sampling scheme, and model development efforts and show how GDC will fit into the larger Heliophysics ecosystem, by 1) obtaining critically needed scientific observations; 2) providing a source for real-time space weather and situational awareness, as well as retrospective studies to further the science of space weather; 3) serving as a "strategic hub" for other space-based and ground-based efforts that want to leverage GDC to perform complementary science. To get the most benefit from GDC’s observations, it will be critical to identify partnerships with other research efforts in the ITM and Geospace arenas, including those utilizing space-based, ground-based, or theoretical investigations. We particularly would like to discuss with groups who are planning or considering observational campaigns during the GDC era, to find ways to leverage GDC observations to do synergistic science that could not be done otherwise.

Douglas E Rowland↗

Metabolic rate meter and method

A method is described for measuring the dynamic metabolic rate of a human or animal. The ratio of the exhaled carbon dioxide to a known amount of C(13)02 introduced into the exhalation is determined by mass spectrometry. This provides an instantaneous measurement of the carbon dioxide generated.

Taylor, T. I.↗