Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed system architecture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Architectural Approaches for Integrating ADMS and DERMS: Challenges, Comparisons, and Real-World Use Cases

The electrical distribution landscape is rapidly transforming due to the proliferation of distributed energy resources (DERs) such as solar panels, wind turbines, battery storage systems, combined heat and power units, and electric vehicles, introducing variability and uncontrollability that traditional grid operators are ill-equipped to manage. This transformation is further accelerated by advancements in Information and Communication Technology infrastructure that connects control centers with end devices, demanding automation and a deeper understanding of new technologies by utility personnel. Advanced grid control techniques using system-level optimization, Artificial Intelligence, and Machine Learning at the enterprise level and distributed level are evolving to address these issues. There is also an opportunity to utilize the enormous data created by these new DER technologies in the grid. Advanced Distribution Management Systems (ADMS) and Distributed Energy Resource Management Systems (DERMS) are critical in addressing these challenges by automating grid operations and enhancing reliability. Given the relatively recent development of ADMS and DERMS, and the still relatively low level of ADMS and DERMS deployment in the industry, there is a notable deficiency in the comprehensive understanding of the challenges and benefits associated with these new technologies, especially with their complementary natures and integration architectures. This paper aims to bridge the knowledge gap in ADMS and DERMS integration, presenting three distinct integration architectures currently available, and discussing the challenges and benefits of each architecture to guide utilities, industry professionals, and researchers in optimizing grid management and decision-making processes for a resilient and efficient energy future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SciDAC-Center for Plasma Edge Simulation Report

The Common Component Architecture (CCA) effort is the embodiment of a long-range program of research and development into the formulation, roles, and use of component technologies in high-performance scientific computing. CCA components can interoperate with other components in a variety of frameworks, including SCIRun2 from the University of Utah. The SCIRun2 framework is also developing the ability to connect components from a variety of different models through a mechanism called meta-components. The meta component model operates by providing a plugin architecture for component models. Abstract components are manipulated and managed by the SCIRun2 framework, while concrete component models perform the actual work and communicate with each other directly. We will leverage the SCIRun2 framework and the Kepler system to orchestrate components in the Fusion Simulation Project (FSP) and to provide a CCA-based interface with Kepler. The groundwork for this functionality is being performed with the Scientific Data Management center. The SDM center is developing CCA-compliant interfaces for expressing and executing workflows and create workflow components based on SCIRun and Ptolemy (Kepler) execution engines, including development of uniform interfaces for selecting, starting, and monitoring scientific workflows. Accomplishments include Introduction to CCA and Simulation Software Systems, Introduction into SCIRun2 and Bridging within SCIRun2, CCALoop: A scalable design for a distributed component framework, and Combining Workflow methodologies with Component Architectures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Incorporating Valve Switching Losses Into a Static Optimal Control Algorithm for the Hybrid Hydraulic-Electric Architecture (HHEA)

The Hybrid Hydraulic-Electric Architecture (HHEA) has, in recent years, been proposed as an energy efficient alternative to conventional load-sensing architectures in mobile machines such as excavators and wheel-loaders. HHEA leverages the advantages of hydraulic power and electric power to eliminate throttling valves while also improving the energy and control performance of the system. The architecture utilizes a set of common pressure rails to provide a majority of power and and a small electric motor driven pump to modulate this power to meet the exact demand. Previous work has developed a computationally efficient Lagrange Multiplier approach for determining the optimal pressure rail selections that minimizes the energy losses in the system. The static model used considers only the energy use for each pressure rail selection but not the losses associated with the valves during the transition. This paper presents an approach to include the switching losses in the model and in the optimization procedure. To capture the switching losses, switching events between different rails and at various input and output flow rates were simulated with consideration of valve spool dynamics. A parameterized model that summarizes the losses is then obtained, allowing switching losses to be added to the previous energy analysis. The performance of the switching loss model was compared with reference data obtained from a high-fidelity simulation model. To incorporate the switching losses into optimal control algorithm, an efficient dynamic programming approach that prevents frequent switching is adopted in place of the Lagrange multiplier approach. The overall effect of switching losses on the energy consumption and optimal control decisions is presented. In general, switching losses contribute to about 9–10% of input energy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Earth Observing System Data and Information System

The system is described in terms of the broad context of scientific cooperation and research which are facilitated by the architecture designed and the nature of the generated data. The Earth Observing System Data and Information System (EOSDIS) is composed of earth-science and applications data systems which archive global-change data and distribute the information to system users. Several archive centers catalogue selected Pathfinder data sets and generate new data products (such as maps of sea ice, cloud studies, etc.) with consistent calibration of all data. The schedule of three versions of EOSDIS is discussed with reference to the system architecture, programmatic plans, and data policy. The critical issue for EOSDIS is international cooperation to sponsor an infrastructure of global change data of this magnitude for public benefit and scientific research.

Maiden, Martha E.↗

The View from the Top of the Mountain: Building a Community of Practice with the GridWise Transactive Energy Framework

The topic of “transactive energy” has received growing attention over the past eighteen months. It has been a part, for example, of the NY Reforming the Energy Vision discussions and the topic of activities such as the National Institute of Standards Transactive Energy Challenge. The growing discussion stems from the realization that new approaches are needed to efficiently and reliably integrate growing numbers of distributed energy resources. In anticipation of the applicability of transactive energy systems to emerging challenges in Grid integration, the GridWise® Architecture Council (GWAC) began to build a community of practice in the area of transactive energy systems. Starting with a workshop on the topic of “transactive energy” in May 2011, the Council brought together about a dozen interested researchers and practitioners from utilities, vendors, labs and academia to compare their approaches and experience in order to create common definitions and understanding within this topical area. This was followed in March 2012 with a second workshop during which about twice as many attendees continued the discussion. At this workshop the need for both a roadmap and a document documenting the foundations of transactive energy, common vocabulary and other definitional aspects was recognized. These two workshops led to the Council organizing the First International Conference and Workshop on Transactive Energy which took place May 23 – 24, 2013 in Portland, Oregon. The Council has continued this work with additional topical workshops, the Second International Conference and Workshop on Transactive Energy held in December 2014, and is currently organizing the Third International Conference and Workshop on Transactive Energy Systems to be held in May 2016. This article provides a summary of the Council’s work to build the community of practice through creation of a Transactive Energy Framework document and related activities. In addition to seeing transactive energy discussions on the agenda for many conferences there are also group activities relating to transactive energy being coordinated by both NIST and SGIP with which GWAC is also involved. The NIST work aims to develop and enhance modeling and simulation tools and integration into modeling and simulation platforms for Transactive Energy evaluation, as well as demonstrate how different transactive approaches may be used to improve reliability and efficiency of the electric grid. This will be accomplished through development of a set of scenarios that can serve as ongoing reference points for modeling and simulation. It is also an example of helping to develop a Transactive Energy community. The ongoing Transactive Energy Coordination Group formed by SGIP reviews the progress and directions of transactive energy activities in related parts of the SGIP and collaborating organizations such as GWAC. One of its activities is assembling a core set of transactive energy use cases as representative of the transactive energy interface requirements. This will enable assessment of interoperability requirements for transactive energy applications and an analysis of standards coverage, gaps, and future needs.

Tranasactive Energy↗

EWTN: Quantifying Mass Transport to Enable Water Electrolyzer Architectures with Low Flow-Rate Sensitivity

To develop cost-effective and high-performing polymer electrolyte water electrolyzers (PEWEs) for gigawatt-scale applications, researchers have focused on reducing precious metal catalyst loadings and optimizing porous transport layers. However, the performance of PEWEs is also affected by system architecture. Mass transport losses are dependent on localized architecture and material interactions. In-situ measurements, such as current density distribution maps have demonstrated advantages in understanding the intricate characteristics and influence of two-phase flow within PEWEs. This study proposes the parameter of effective water transport number (EWTN) as a quantitative tool to investigate such current density distribution (CDD) measurements for PEWEs. Results show that higher flow-rates have EWTN values of 0.95 and above, indicating no mass transport limitations; while lower flow-rates with large gradients CDD have EWTN values between 0.6-0.8, indicating mass transport limited conditions. The new analysis also identified a correlation between mass transport losses due to bubble accumulation, membrane hydration, and ohmic overpotentials. To address these limitations, an unitized pin-type LGDL/flow-field design was developed, which effectively prevents local gas phase accumulation, resulting in improved mass transport characteristics. The results of this work show reduced flow-rate sensitivity with the pin-type architecture and ∼13% increased performance at 0.24 ml / min / cm 2 .

Electrochemistry↗

Utility-Scale Operational Consequences for Solar Grid Services

This report delves into the critical aspects of grid services provided by solar inverter-based resources (IBRs), with an emphasis on the evolving landscape of microgrids, virtual power plants (VPPs), aggregators, and distributed energy resource management systems (DERMS). As the energy sector undergoes a transformative shift towards more decentralized and resilient grid architectures, understanding the multifaceted risks associated with these technologies becomes paramount. The report categorizes these risks into organizational, technical, and procedural domains, providing a thorough risk assessment framework that stakeholders can utilize to anticipate and mitigate potential issues. In addressing the increasing complexity of grid interconnections, the report highlights the importance of Cyber-Informed Engineering (CIE). By embedding engineering controls and cybersecurity measures into the early stages of system design, this approach aims to fortify grid infrastructure against emerging cyber threats. The analysis includes an exploration of best practices and strategies for integrating CIE principles to enhance grid security and resilience. To provide practical insights, the report conducts a detailed consequence analysis of various grid services and cyber mitigations that can be applied through the interconnection process. This analysis evaluates the potential impacts of different failure modes and vulnerabilities, offering a clear understanding of the consequences that could arise from disruptions within the energy grid. The findings are further enriched by a series of case studies that illustrate real-world scenarios and lessons learned from past incidents. Through this comprehensive examination of grid services and their criticality, the report aims to prepare industry professionals with the knowledge and tools necessary to navigate the complexities of modern energy systems. By providing a comprehensive approach that includes risk assessment, cybersecurity, and consequence analysis, solar stakeholders can more effectively guarantee the reliability, efficiency, and security of the energy grid.

14 SOLAR ENERGY↗

Transportable telemetry workstation for future distributed system environments

A Transportable Telemetry Workstation (TTW) has been developed to meet the need for reduction in size and cost per station while maintaining high performance specifications in distributed system environments. The TTW consists primarily of the adaptation of NASA's Goddard Space Flight Center VLSI components and system architecture to a personal computer and its architecture. The overall system, the architecture, the TTW Controller Card, TTW Synchronizer Card, custom backplane bus, and system software structure are described.

Collins, Aaron↗

High-speed digital fiber optic links for satellite traffic

Large aperture phased array antennas operating at millimeter wave frequencies are designed for space-based communications and imaging platforms. Array elements are comprised of active T/R modules which are linked to the central processing unit through high-speed fiber-optic networks. The system architecture satisfying system requirements at millimeter wave frequency is T/R level data mixing where data and frequency reference signals are distributed independently before mixing at the T/R modules. This paper demonstrates design procedures of a low loss high-speed fiber-optic link used for transmission of data signals over 600-900 MHz bandwidth inside satellite. The fiber-optic link is characterized for transmission of analog and digital data. A dynamic range of 79 dB/MHz was measured for analog data over the bandwidth. On the other hand, for bursted SMSK satellite traffic at 220 Mbps rates, BER of 2 x 10 to the -7th was measured for E(b)/N(o) of 14.3 dB.

Daryoush, A. S.↗

An open, parallel I/O computer as the platform for high-performance, high-capacity mass storage systems

APTEC Computer Systems is a Portland, Oregon based manufacturer of I/O computers. APTEC's work in the context of high density storage media is on programs requiring real-time data capture with low latency processing and storage requirements. An example of APTEC's work in this area is the Loral/Space Telescope-Data Archival and Distribution System. This is an existing Loral AeroSys designed system, which utilizes an APTEC I/O computer. The key attributes of a system architecture that is suitable for this environment are as follows: (1) data acquisition alternatives; (2) a wide range of supported mass storage devices; (3) data processing options; (4) data availability through standard network connections; and (5) an overall system architecture (hardware and software designed for high bandwidth and low latency). APTEC's approach is outlined in this document.

Abineri, Adrian↗

Task-level control for autonomous robots

Task-level control refers to the integration and coordination of planning, perception, and real-time control to achieve given high-level goals. Autonomous mobile robots need task-level control to effectively achieve complex tasks in uncertain, dynamic environments. This paper describes the Task Control Architecture (TCA), an implemented system that provides commonly needed constructs for task-level control. Facilities provided by TCA include distributed communication, task decomposition and sequencing, resource management, monitoring and exception handling. TCA supports a design methodology in which robot systems are developed incrementally, starting first with deliberative plans that work in nominal situations, and then layering them with reactive behaviors that monitor plan execution and handle exceptions. To further support this approach, design and analysis tools are under development to provide ways of graphically viewing the system and validating its behavior.

Simmons, Reid↗

File Management In Space

We propose that the user interact with the spacecraft as if the spacecraft were a file server, so that the user can select and receive data as files in standard formats (e.g., tables or images, such as jpeg) via the Internet. Internet technology will be used end-to-end from the spacecraft to authorized users, such as the flight operation team, and project scientists. The proposed solution includes a ground system and spacecraft architecture, mission operations scenarios, and an implementation roadmap showing migration from current practice to the future, where distributed users request and receive files of spacecraft data from archives or spacecraft with equal ease. This solution will provide ground support personnel and scientists easy, direct, secure access to their authorized data without cumbersome processing, and can be extended to support autonomous communications with the spacecraft.

Critchfield, Anna R.↗

Tenth Goddard Conference on Mass Storage Systems and Technologies in Cooperation with the Nineteenth IEEE Symposium on Mass Storage Systems

This document contains copies of those technical papers received in time for publication prior to the Tenth Goddard Conference on Mass Storage Systems and Technologies which is being held in cooperation with the Nineteenth IEEE Symposium on Mass Storage Systems at the University of Maryland University College Inn and Conference Center April 15-18, 2002. As one of an ongoing series, this Conference continues to provide a forum for discussion of issues relevant to the ingest, storage, and management of large volumes of data. The Conference encourages all interested organizations to discuss long-term mass storage requirements and experiences in fielding solutions. Emphasis is on current and future practical solutions addressing issues in data management, storage systems and media, data acquisition, long-term retention of data, and data distribution. This year's discussion topics include architecture, future of current technology, storage networking with emphasis on IP storage, performance, standards, site reports, and vendor solutions. Tutorials will be available on perpendicular magnetic recording, object based storage, storage virtualization and IP storage.

Kobler, Benjamin↗

Network Theory: A Primer and Questions for Air Transportation Systems Applications

A new understanding (with potential applications to air transportation systems) has emerged in the past five years in the scientific field of networks. This development emerges in large part because we now have a new laboratory for developing theories about complex networks: The Internet. The premise of this new understanding is that most complex networks of interest, both of nature and of human contrivance, exhibit a fundamentally different behavior than thought for over two hundred years under classical graph theory. Classical theory held that networks exhibited random behavior, characterized by normal, (e.g., Gaussian or Poisson) degree distributions of the connectivity between nodes by links. The new understanding turns this idea on its head: networks of interest exhibit scale-free (or small world) degree distributions of connectivity, characterized by power law distributions. The implications of scale-free behavior for air transportation systems include the potential that some behaviors of complex system architectures might be analyzed through relatively simple approximations of local elements of the system. For air transportation applications, this presentation proposes a framework for constructing topologies (architectures) that represent the relationships between mobility, flight operations, aircraft requirements, and airspace capacity, and the related externalities in airspace procedures and architectures. The proposed architectures or topologies may serve as a framework for posing comparative and combinative analyses of performance, cost, security, environmental, and related metrics.

Holmes, Bruce J.↗

Data Centers and Digital Assurance Workshop 3 – Mitigations for Digital Assurance Risks

The third session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort, held on November 18, 2025, focused on developing mitigation strategies for digital assurance risks identified in previous workshops. Hosted by Idaho National Laboratory (INL) and ScottMadden, the session emphasized the application of Cyber-Informed Engineering (CIE) to data center infrastructure, particularly at the utility–data center interface. Participants revisited and ranked key digital assurance risks, including architecture and interface weaknesses, governance gaps, and AI-enabled threats. The workshop introduced the 12 principles of CIE, advocating for consequence-focused design, engineered controls, and secure information architecture to proactively reduce cyber-physical vulnerabilities. These principles were applied to critical data center systems such as power distribution, UPS, cooling, SCADA/BMS, and grid-forming batteries. The session also addressed governance challenges at the interconnection boundary, highlighting the need for clear roles in telemetry sharing, firmware management, and trip settings. Special attention was given to emerging risks from behind-the-meter (BTM) generation, including reverse-power flow and the integration of small modular reactors (SMRs), which shift data centers from large loads to complex generation nodes. Participants explored how interconnection agreements can serve as enforceable instruments for digital assurance, and reviewed gaps in current standards such as NERC CIP, IEC 62443, and IEEE 1547. The workshop concluded with pathways to standardization, including model agreement language, state-level programs, and expanded NERC guidance. INL also presented tools and frameworks for secure procurement and supplier risk management, reinforcing the need for integrated engineering and policy solutions to secure the evolving data center–grid ecosystem. Session 3 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Initial Development of A Digital Twin Model for an Electrified Aircraft Propulsion Emulation Rig

In support of aviation fuel burn and emission reduction goals, NASA is pursing high-payoff research investments that promise to transform aviation. This includes investments in Electrified Aircraft Propulsion (EAP), which relies on the generation, storage, transmission, and use of electrical power for producing thrust and optimizing propulsion system efficiency. Multiple technology challenges must be addressed to unlock the full potential of EAP. This includes advances in propulsion controls, which will be vital for ensuring coordinated efficient operation of the complex integrated subsystems that comprise EAP architectures. To support EAP controls research, the NASA Glenn Research Center has developed the Hybrid Propulsion Emulation Rig (HyPER). The HyPER laboratory hardware includes shaft-mounted electric machines, power converters, power supplies, power distribution cables, and an energy storage device that can be reconfigured to represent a variety of EAP architectures. It also includes an integrated real-time computer system that hosts developed EAP control software and turbomachinery simulations. This enables the electrical system and rotating shafts of EAP designs to be implemented in actual hardware and integrated with turbomachinery simulations and system-level EAP control logic implemented in software. In this form, the HyPER laboratory provides a partially simulated, partially hardware-in-the-loop test environment enabling the initial development and evaluation of EAP control technology. A prerequisite for the development of EAP control designs is the availability of a system model that accurately reflects the operation of the electrical system hardware. To support this need, a digital twin model of the HyPER electrical system hardware is under development. This model is being coded in the MATLAB Simulink environment and uses the NASA-developed Electrical Modeling and Thermal Analysis Toolbox (EMTAT) to construct a digital twin framework. EMTAT contains generic electrical component building blocks that are simulated at turbomachinery timescales. Associated inputs and outputs allow the blocks to be combined to model complete electrical systems. The EMTAT blocks also contain adjustable internal maps and parameters that can be set to reflect the operation of a specific electrical component. For the HyPER digital twin, the settings of these EMTAT block internal maps and parameters is determined through machine learning approaches applied to characterization run data collected from the laboratory. During characterization runs the laboratory electrical system hardware is subjected to a full range of torque, speed, and power settings. Acquired data is then used to estimate EMTAT block parameters using a variety of machine learning techniques. The resulting digital twin model is found to match the operation of actual HyPER hardware with an accuracy suitable for control development purposes. It also holds promise for other applications including modeling the performance of HyPER laboratory reconfigurations and model-based anomaly detection. Planned follow-on work to automate post-processing of acquired laboratory data to update the HyPER digital twin model will also be presented and discussed.

Electrified Aircraft Propulsion↗

National Renewable Energy Laboratory (NREL) Topic 2 Final Report: End-to-End Communication and Control System to Support Clean Energy Technologies

This document is the final report of a two-year development, test, and demonstration project, 'Cohesive Application of Standards- Based Connected Devices to Enable Clean Energy Technologies.' The project was part of the National Renewable Energy Laboratory's (NREL's) Integrated Network Testbed for Energy Grid Research and Technology (INTEGRATE) initiative hosted at Energy Systems Integration Facility (ESIF). This project demonstrated techniques to control distribution grid events using the coordination of traditional distribution grid devices and high-penetration renewable resources and demand response. Using standard communication protocols and semantic standards, the project examined the use cases of high/low distribution voltage, requests for volt-ampere-reactive (VAR) power support, and transactive energy strategies using Volttron. Open source software, written by EPRI to control distributed energy resources (DER) and demand response (DR), was used by an advanced distribution management system (ADMS) to abstract the resources reporting to a collection of capabilities rather than needing to know specific resource types. This architecture allows for scaling both horizontally and vertically. Several new technologies were developed and tested. Messages from the ADMS based on the common information model (CIM) were developed to control the DER and DR management systems. The OpenADR standard was used to help manage grid events by turning loads off and on. Volttron technology was used to simulate a homeowner choosing the price at which to enter the demand response market. Finally, the ADMS used newly developed algorithms to coordinate these resources with a capacitor bank and voltage regulator to respond to grid events.

24 POWER TRANSMISSION AND DISTRIBUTION↗