Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Calculation of the Non-Inductive Current Profile in High-Performance NSTX Plasmas

The constituents of the current profile have been computed for a wide range of high-performance plasmas in NSTX [M. Ono, et al., Nuclear Fusion 40, 557 (2000)]; these include cases designed to maximize the non-inductive fraction, pulse length, toroidal-β, or stored energy. In the absence of low-frequency MHD activity, good agreement is found between the reconstructed current profile and that predicted by summing the independently calculated inductive, pressure-driven, and neutral beam currents, without the need to invoke any anomalous beam ion diffusion. Exceptions occur, for instance, when there are toroidal Alfven eigenmode avalanches or coupled m/n=1/1+2/1 kink-tearing modes. In these cases, the addition of a spatially and temporally dependent fast ion diffusivity can reduce the core beam current drive, restoring agreement between the reconstructed profile and the summed constituents, as well as bringing better agreement between the simulated and measured neutron emission rate. An upper bound on the fast ion diffusivity of ~0.5-1 m2/sec is found in “MHD-free” discharges, based on the neutron emission, time rate of change of the neutron signal when a neutral beam is stepped, and reconstructed on-axis current density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrochemical mechanisms of leakage‐current in photovoltaic modules

Abstract This paper analyzes the mechanisms and pathways for leakage current flow observed in Si photovoltaic modules subjected to high temperature and humidity and a large voltage bias with respect to ground. The current inside of the frame is in the form of electron motion, but in the glass and polymer, it is in at least a large part attributable to the movement of ions. When the mode of current flow changes from electronic to ionic conduction, electrochemical reactions will take place at the interface. This can include reactions that produce volatile chemical species like H 2 , CO x , and O 2 , along with ionic species such as OH − and H 3 O + . Here, we see evidence of the importance of different charge carriers with different diffusion rates and the influence of electrochemical processes involved. The application of negative voltage to the cell circuit affects the resistivity of glass producing surfaces with poor conductivity but with some increases in the electrochemical potential producing complicated interactions that are important when the voltage is changed. In the polymer, there is the development of a space charge region and a chemical gradient providing two oppositional forces to current flow, which when released create a complicated discharge process. Here, we give a basic understanding of the charge/discharge of PV cells highlighting how the specific mechanisms are important in understanding some of the degradation processes in PV modules. We find that there is evidence of multiple significant charge carrier species with different diffusion time scales. The glass/polymer interface forms a depleted region of higher resistance after prolonged exposure to current. Charge also builds up at the polymer to cell antireflective coating interface and mostly flows to the gridlines to experience electrochemical reactions. These complexities result in non‐linear behavior where the apparent resistivities of the different layers change during charge/discharging processes, making the modeling of the current flow extremely difficult.

14 SOLAR ENERGY↗

Measurement of high-order current correlators

The feasibility of measuring high-order current correlators by means of a linear detector is analyzed. Two different types of measurements are considered: measurement of fluctuation power spectrum and measurement of unequal-time current correlators at fixed points in time. In both cases, formally exact expressions in terms of Keldysh time-ordered electron current operators are derived for the detector output. An explicit time ordering is found for the current correlators under the expectation operator used in measurements of high-order unequal-time current correlators. The situation when a detector measures current correlators at different points of a conductor is considered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Physics-based control-oriented modeling of the current density profile evolution in NSTX-Upgrade

Active control of the toroidal current density profile is among those plasma control milestones that the National Spherical Torus eXperiment-Upgrade (NSTX-U) program must achieve to realize its next-step operational goals. Motivated by the coupled, nonlinear, multivariable, distributed-parameter plasma dynamics, the first step towards control design is the development of a physics-based, control-oriented model for the current profile evolution in response to non-inductive current drives and heating systems. The evolution of the toroidal current density profile is closely related to the evolution of the poloidal magnetic flux profile, whose dynamics is modeled by a nonlinear partial differential equation (PDE) referred to as the magnetic-flux diffusion equation (MDE). The proposed control-oriented model predicts the spatial-temporal evolution of the current density profile by combining the nonlinear MDE with physics-based correlations obtained at NSTX-U for the electron density, electron temperature, and non-inductive current drives (neutral beams). The resulting first-principles-driven, control-oriented model is tailored for NSTX-U based on predictions by the time-dependent transport code TRANSP. Furthermore, main objectives and possible challenges associated with the use of the developed model for the design of both feedforward and feedback controllers are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Factors Affecting Limiting Current in Solid Oxide Fuel Cells or Debunking the Myth of Anode Diffusion Polarization

Limiting current densities for solid oxide fuel cells were measured using both button cells and a flow-through cell. The cell anodes were supplied mixtures of humidified hydrogen and various inert gasses. It was demonstrated that the true limiting current in flow-through cells is reached when either: the hydrogen is nearly or completely depleted at the anode-electrolyte interface near the outlet; or when the concentration of steam at that interface becomes high enough to interfere with adsorption or transport of the remaining hydrogen near the triple-phase boundaries. Choice of inert gas had no effect on limiting currents in the flow-through tests, indicating that diffusion within the porous anode had no significant effect on cell performance at high currents. In the button cells, the apparent limiting currents were significantly changed by the choice of inert gas, indicating that they were determined by diffusion through the bulk gas within the support tube. It was concluded that the apparent limiting currents measured in button cells are influenced more by parameters of the experimental setup, such as the proximity of the fuel tube outlet, than by the physical properties of the anode.

08 HYDROGEN↗

Influence of current density on microstructure of pulse electrodeposited tin coatings

Pulse electrodeposited tin coatings on copper substrate have been synthesized from an aqueous solution containing sodium stannate (Na{sub 2}SnO{sub 3}.3H{sub 2}O) and sodium hydroxide (NaOH). The effect of current density on surface morphology of the deposits has been investigated. As deposited coatings are characterized by X-ray diffraction, scanning electron microscopy, electron backscatter diffraction, and line profile analysis. The X-ray diffraction analysis shows that the deposits consist of tetragonal ({beta}-Sn) structure with microcrystalline grains. The deposits plated at lower current density exhibit (110) texture which decreases with increasing current densities. The effects of current density on Cu-Sn diffusion and whisker growth of the electrodeposited tin coatings are also reported here. - Highlights: Black-Right-Pointing-Pointer Pulse electrodeposition of Sn from aqueous alkaline solution without adding any organic additive. Black-Right-Pointing-Pointer Effect of current density on morphology and whisker growth in tin coatings aged for 1 year. Black-Right-Pointing-Pointer Solution bath is stable and can be operated over a wide range of current density.

36 MATERIALS SCIENCE↗

Current–voltage characteristics of organic heterostructure devices with insulating spacer layers

The dark current density in donor/acceptor organic planar heterostructure devices at a given forward voltage bias can either increase or decrease when an insulating spacer layer is added between the donor and acceptor layers. The dominant current flow process in these systems involves the formation and subsequent recombination of interfacial exciplex states. If the exciplex recombination rate limits current flow, an insulating interface layer decreases the dark current. However, if the exciplex formation rate limits the current, an insulating interface layer may increase the dark current. As a result, we present a device model to describe this behavior, and we discuss relevant experimental data.

25 ENERGY STORAGE↗

The effect of current and lambda on white-etch-crack failures

White etching cracks (WECs) have been associated with premature failure of wind turbine roller bearings. Various drivers for the generation of WECs have been identified such as loading conditions, slip, steel quality, lubrication, hydrogen embrittlement, corrosion fatigue cracking, and stray electrical currents passing through the surface. Here, in this work, a benchtop test rig utilizing a three-ring-on-roller test configuration was used to investigate the effect of electrical current and operation in different lubricating regimes, defined by lambda (λ), on high-quality bearing steel samples tested in a commercially available power transmission EP gear lubricant. It was observed that there is an inverse correlation between the magnitude of electric current applied to the ring/ roller system and time-to-failure. Higher current magnitudes lead to shorter time-to-failure than lower current magnitudes, with macropitting as the main failure mode. Sub-surface investigation revealed the presence of WECs in all cases. For the same current magnitude, tests conducted in boundary and mixed lubrication regimes showed that time-to-failure increased as lambda increased, and the tests resulted in WEC related macropits, whereas tests conducted in near-hydrodynamic regime resulted in surface damage with no macropit. It was also noted that a shift toward near-hydrodynamic lubrication resulted in a distinct surface distress on the roller surface. Furthermore, there seems to be a transition in the mixed regime during which the surface distress occurred. The damage on the surface of the test samples resembled non-spatially, periodic, groove-like corrugations and, in some cases, crater-like depressions. Sub-surface imaging, performed by sequential sectioning, revealed the presence of WECs in all cases, and broad, branching cracks that were more prevalent under the more severe boundary conditions.

17 WIND ENERGY↗

Light-Induced Currents at Domain Walls in Multiferroic BiFeO3.

Multiferroic BiFeO3 (BFO) films with spontaneously formed periodic stripe domains can generate above-gap open circuit voltages under visible light illumination; nevertheless the underlying mechanism behind this intriguing optoelectronic response has not been understood to date. Here, we make contact-free measurements of light-induced currents in epitaxial BFO films via detecting terahertz radiation emanated by these currents, enabling a direct probe of the intrinsic charge separation mechanisms along with quantitative measurements of the current amplitudes and their directions. In the periodic stripe samples, we find that the net photocurrent is dominated by the charge separation across the domain walls, whereas in the monodomain samples the photovoltaic response arises from a bulk shift current associated with the non-centrosymmetry of the crystal. The peak current amplitude driven by the charge separation at the domain walls is found to be 2 orders of magnitude higher than the bulk shift current response, indicating the prominent role of domain walls acting as nanoscale junctions to efficiently separate photogenerated charges in the stripe domain BFO films. These findings show that domain-wall-engineered BFO thin films offer exciting prospects for ferroelectric-based optoelectronics, as well as bias-free strong terahertz emitters.

36 MATERIALS SCIENCE↗

Large Local Currents in a Lithium-Ion Battery during Rest after Fast Charging

Increasing electric vehicle (EV) adoption requires lithium-ion batteries that can be charged quickly and safely. Some EV batteries have caught on fire despite being neither charged nor discharged. While the lithium that plates on graphite during fast charging affects battery safety, so do the internal ionic currents that can occur when the battery is at rest after charging. These currents are difficult to quantify; the external current that can readily be measured is zero. Here we study a graphite electrode at rest after 6C fast charging using operando X-ray microtomography. We quantify spatially resolved current density distributions that originate at plated lithium and end in underlithiated graphite particles. The average current densities decrease from 1.5 to 0.5 mA cm -2 in about 20 min after charging is stopped. Surprisingly, the range of the stripping current density is independent of time, with outliers above 20 mA cm -2 . In conclusion, the persistence of outliers provides a clue as to the origin of catastrophic failure in batteries at rest.

25 ENERGY STORAGE↗

Contribution of Electron Pressure to Ring Current and Ground Magnetic Depression Using RAM-SCB Simulations and Arase Observations During 7–8 November 2017 Magnetic Storm

Understanding the physical processes that control the dynamics of energetic particles in the inner magnetosphere is important for both space-borne and ground-based assets essential to the modern society. The storm time distribution of ring current particles in the inner magnetosphere depends strongly on their transport in the evolving electric and magnetic fields along with particle acceleration and loss. Here, we investigated the ring current particle variations using observations and simulations. We compared the ion (H + , He + , and O + ) and electron flux and plasma pressure variations from Arase observations with the self-consistent inner magnetosphere model: Ring current Atmosphere interactions Model with Self Consistent magnetic field (RAM-SCB) during the 7–8 November 2017 geomagnetic storm. We investigated the contribution of the different species (ions and electrons) to the magnetic field deformation observed at ground magnetic stations (09°–45° MLat) using RAM-SCB simulations. The results show that the ions are the major contributor with ~88% and electrons contribute ~12% to the total ring current pressure. It is also found that the electron contribution is non-negligible (~18%) to the ring current in dawn-side during the main phase of the storm. Thus, the electron contribution to the storm time ring current is important and should not be neglected.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of an all-permanent-magnet microwave ion source equipped with multicusp magnetic fields for high current proton beam production

An all-permanent-magnet (APM) microwave hydrogen ion source was developed to reduce the size and to simplify structure of a conventional solenoid coil microwave ion source developed for reliability improvement of high current proton linac application systems. The difficulty in developing the APM source was sensitive dependence of the source performance on axial magnetic field in the microwave discharge chamber. It was difficult to produce high current proton beam stably without precise tuning of the magnetic field using solenoid coils. We lowered the sensitivity using multicusp magnetic fields for plasma confinement at the discharge chamber sidewall of the source. This enabled stable high current proton beam production with the APM microwave ion source with no tuning coil. The water cooling and the power supply for the coils are not necessary for the APM source, which leads to better reliability and system simplification. The outer diameter of the APM source was around 300 mm, which was 20% lower than the coil source. The APM source produced a maximum hydrogen ion beam current of 65 mA (high current density of 330 mA/cm{sup 2}, proton ratio of 87%, and beam energy of 30 keV) with a 5 mm diameter extraction aperture, pulse width of 400 {mu}s, and 20 Hz repetition rate at 1.3 kW microwave power. This performance is almost the same as the best performances of the conventional coil sources. The extracted ion beams were focused with electrostatic five-grid lens to match beam to acceptance of radio-frequency quadrupole linacs. The maximum focused beam current through the orifice (5 mm radius) and the lens was 36 mA and the 90% focused beam half-width was 1-2 mm.

43 PARTICLE ACCELERATORS↗

A particle simulation of current sheet instabilities under finite guide field

The instability of a Harris current sheet under a broad range of finite guide field (B{sub G}) is investigated using a linearized ({delta}f) gyrokinetic electron and fully kinetic ion particle simulation code. The simulation is carried out in the two-dimensional plane containing the guide field along y and the current sheet normal along z. In this particle model, the rapid electron cyclotron motion is removed, while the realistic mass ratio m{sub i}/m{sub e}, finite electron Larmor radii, and wave-particle interactions are kept. It is found that for a finite B{sub G}/B{sub x0}{<=}1, where B{sub x0} is the asymptotic antiparallel component of magnetic field, three unstable modes, i.e., modes A, B, and C, can be excited in the current sheet. Modes A and C, appearing to be quasielectrostatic modified two-stream instability/whistler mode, are located mainly on the edge of the current sheet. Mode B, on the other hand, is confined in the current sheet center and carries a compressional magnetic field ({delta}B{sub y}) perturbation along the direction of electron drift velocity. Our new finding suggests that mode B may contribute directly to the electron anomalous resistivity in magnetic reconnection. In the cases with extremely large B{sub G}/B{sub x0}>>1, the wave modes evolve to a globally propagating instability. The simulation shows that the presence of finite B{sub G} modifies the physics of the current sheet significantly.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of Charging Control of a Single Wafer High Current Spot Beam Implanter

This paper focuses on the characterization of charging control of an Axcelis Optima HD single wafer high current spot beam implanter using MOS capacitors with attached antennas of different size and shape. Resist patterns are implemented on Infineon Technologies own charging control wafers to investigate the influence of photo resist on charging damage. Compared to batch high current implanters the design of the beamline and the beam shape are comparable to single wafer high current spot beam implanters, however due to the different scanning architecture the dose rate of the single wafer high current spot beam implanters is significantly higher compared to the batch tools. Therefore, the risk of charging damage will be higher. The charging damage was studied as a function of the energy, the beam current and the most important plasma flood gun parameters. The results have shown that for very high antenna ratios the charging damage for single wafer implanters, even spot or ribbon beam implanters, is higher than for high current batch implanters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integration of an Axcelis Optima HD Single Wafer High Current Implanter for p- and n-S/D Implants in an Existing Batch Implanter Production Line

This paper is focused on the integration and qualification of an Axcelis Optima HD single wafer high current spot beam implanter in an existing 200 mm production line with different types of Axcelis batch implanters for high current applications. Both the design of the beamline and the beam shape are comparable between single wafer and batch high current spot beam implanters. In contrast to the single wafer high current ribbon beam implanter, energy contamination is not a concern for the considered spot beam tool because the drift mode can be used down to energies in the 2 keV region. The most important difference between single wafer and batch high current implanters is the significantly higher dose rate and, therefore, the higher damage rate for the single wafer tool due to the different scanning architecture. The results of the integration of high dose implantations, mainly for p- and n-S/D formation, for DRAM 110 nm without pre-amorphization implantation (PAI), CMOS Logic from around 250 nm down to 90 nm without and with PAI, are presented and discussed. Dopant concentration profile analysis using SIMS was performed for different technologies and implantation conditions. The impurity activation was measured using sheet resistance and in some cases spreading resistance technique was applied. The amorphous layer thickness was measured using TEM. Finally, device data are presented in combination with dose, energy and beam current variations. The results have shown that the integration of implantation processes into crystalline structure without PAI is more complex and time consuming than implantations into amorphous layer where the damage difference due to the different dose rates is negligible.

36 MATERIALS SCIENCE↗

Beam Current Improvements on the Axcelis Optima HD Imax Implanter

The ability to use large molecular species such as octadecaborane (B{sub 18}H{sub 22}) has been investigated at semiconductor device manufacturers as a way to significantly increase wafer throughput relative to standard high current ion implanters. Over the past two years, improvements in the machine design to support the use of B{sub 18}H{sub 22} have led to beam current increases of 50% from 30 pmA to 45 pmA of boron at an equivalent boron energy of 4 keV. This boron energy is required by p{sup +} doping of dual poly gate (DPG) structures in DRAM. Beam current has also been significantly improved at the low equivalent boron energies anticipated to be required by 32 nm processes for PMOS source/drain extensions (SDE). For example, at 250 eV equivalent beam energy, a 100% increase in cluster boron beam current has been attained.This paper describes the techniques by which these beam current improvements were accomplished, primarily through the refinement of ion beam optics. Other techniques for increasing overall tool productivity are also described, such as beam utilization and overall operational improvements. Wafer throughputs are presented for critical p{sup +} implant processes such as dual poly gate (DPG), source/drain (S/D), source drain extension (SDE) and S/D contact. The higher throughputs resulting from these changes are translated into a cost per wafer (CPW) model and it is demonstrated that an increase in average beam current is the largest contributor to a reduction in CPW.

36 MATERIALS SCIENCE↗

Search for Antineutrino Charged Current Coherent Pion Production at SciBooNE

The SciBooNE experiment (Fermilab) recently published results of a search for charged current coherent pion production in neutrino mode: muon neutrinos scattering on carbon, v{sub {mu}}{sup 12}C{yields}{mu}{sup -12}C{pi}{sup +}. The results of this study are that no evidence for coherent pion production is observed, and SciBooNE set 90% confidence level upper limits on the cross section ratio of charged current coherent pion production to the total charged current cross section. Recently proposed new coherent pion models predict a production of charged current coherent pion events just below the SciBooNE's upper limit. Motivated by this, we performed a search for charged current coherent pion production using SciBooNE's collected antineutrino data since antineutrino data are expected to be more sensitive to look at coherent pion production than neutrino data.This paper describes preliminary results of a search for antineutrino charged current coherent pion production at the SciBooNE experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low noise constant current source for bias dependent noise measurements

A low noise constant current source used for measuring the 1/f noise in disordered systems in ohmic as well as nonohmic regime is described. The source can supply low noise constant current starting from as low as 1 {mu}A to a few tens of milliampere with a high voltage compliance limit of around 20 V. The constant current source has several stages, which can work in a standalone manner or together to supply the desired value of load current. The noise contributed by the current source is very low in the entire current range. The fabrication of a low noise voltage preamplifier modified for bias dependent noise measurements and based on the existing design available in the MAT04 data sheet is also described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗