Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenic temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Development of a compact, light weight magnetic bearing

A compact, lightweight radial-load bearing has been devised with permanent magnet bias and actively controlled radial loading. The novel design uses permanent magnets to generate a coaxial magnetic field that energizes two radial air gaps. Two electromechanical stators modulate the airgap field in order to impart stability and control. Attention is given to the implementation of this design in an application involving operation at ambient and cryogenic temperatures at loads of up to 500 lbs. Stiffnesses of up to 17,500 N/mm have been obtained.

Meeks, Crawford↗

Lightweight Memory-Metal Pin Puller

Memory-metal pin puller designed for use in aperture-cover mechanism of camera aboard spacecraft adapted to small-volume instrument environments that must be kept free of contamination. Includes memory-metal wires pulling pin when heated. Small and light in weight, uses relatively simple electronic drive circuitry consisting of timed source of current. Adapted to operate at cryogenic temperatures and in vacuum as well as in normal-temperature environment, cycled large number of times without degradation of performance.

Ford, Virginia G.↗

Mechanical properties of the fiberglass prepreg system used for the National Transonic Facility replacement blade set

The results are presented of mechanical and physical properties characterization testing for the fiber glass prepreg system used to fabricate 15 of the replacement set of 25 fan blades for the National Transonic Facility. The fan blades were fabricated to be identical to the original blade set with the exception that the 7576 style E glass cloth used for the replacement set has a different surface finish than the original 7576 cloth. The 7781 E glass cloth and resin system were unchanged. The data are presented for elevated, room, and cryogenic temperatures. The results are compared with data from the original blade set and evaluated against selected structural design criteria. Test experience is described along with recommendations for future testing of these materials if required.

Young, Clarence P., Jr.↗

SIRTF/IRS cryogenic grating drive mechanism (ARC second positioning at 4 K)

The requirements, design, and test results of a grating drive mechanism for the Infrared Spectrograph (IRS) science instrument on the proposed superfluid helium-cooled Space Infrared Telescope Facility (SIRTF) are described. The IRS grating drive mechanism, tested in the fall of 1989, satisfied all performance requirements in vacuum at 4 K. Measured mechanism performance included: 1.4 arc sec root-mean-square (rms) error positioning resolution; 2.2 arc sec rms position repeatability error, less than 10 millijoules/deg dissipated power; and 170 deg angular range of travel. Mechanisms that precisely position optical elements at very low cryogenic temperatures (at/below 4 K) are vital to the operating success of a number of proposed infrared scientific instruments like those in SIRTF.

Kubitschek, Michael J.↗

Probability of failure and risk assessment of propulsion structural components

Because of the increasing need to account for the uncertainties in material properties, loading conditions, geometry, etc., a methodology was developed to determine structural reliability and to assess the associated risk. The methodology consists of a probabilistic structural analysis by a probabilistic finite element computer code, numerical evaluation of stochastic structures under stress (NESSUS), and a generic probabilistic material property model. The methodology is versatile and is equally applicable to structures operating at high and cryogenic temperature environments. Results obtained demonstrate that the issues of structural reliability and risk can be formally evaluated by using the methodology developed which is inclusive of the uncertainties in material properties, structural parameters, and loading conditions. The methodology is described in some detail with illustrative examples.

Shiao, Michael C.↗

Lunar base siting

As with any planetary body, the lunar surface is quite heterogeneous. There are widely dispersed sites of particular interest for known and potential resource availability, selenology, and lunar observatories. Discriminating characteristics include solar illumination, view of earth, local topography, engineering properties of the regolith and certain geological features, and local mineralogy and petrology. Space vehicle arrival and departure trajectories constitute a minor consideration. Over time, a variety of base sites will be developed serving different purposes. Resource-driven sites may see the fastest growth during the first decades of lunar development, but selection of the most favorable sites is likely to be driven by suitability for a combination of activities. As on earth, later development may be driven by geographical advantages of surface transportation routes. With the availability of near-constant sunlight for power generation, as well as permanently shadowed areas at cryogenic temperatures, polar sites are attractive because they require substantially less earth-launched mass and lower equipment complexity for an initial permanent base. Discovery of accessible volatiles reservoirs, either in the form of polar permafrost or gas reservoirs at other locations, would dramatically increase the attractiveness of any site from a logistical support and selenological point of view. Amid such speculation, no reliable evidence of such volatiles exist. More reliable evidence exists for areas of certain mineral concentrations, such as ilmenite, which could form a feedstock for some proposed resource extraction schemes. While tentative selections of advantageous base sites are made, new data from lunar polar orbiters and the Galileo polar flybys would be very helpful.

Staehle, Robert L.↗

Electronically scanned multichannel pressure transducer system for cryogenic environments

Research into the application of custom doped piezoresistive silicon pressure sensors has led to a multichannel pressure sensor design that will operate accurately and reliably at cryogenic temperatures. The thermal effects upon multichannel pressure sensors are mapped by thermal calibrations and are represented by sets of nth order coefficients specific to each sensor. The thermal offset and sensitivity variations are corrected by computer algorithms which scan the sensors, recall correction coefficients from thermally induced sensor variations, and apply these to correct the sensor's output measurement uncertainty to within 0.5 percent of full scale output for combined offset and sensitivity. A prototype sensor system has been fabricated, and performance test data are presented.

Chapman, John J.↗

The transient gamma-ray spectrometer

The authors describe the Transient Gamma-Ray Spectrometer (TGRS) to be flown onboard the WIND spacecraft. This instrument is designed to detect cosmic gamma-ray bursts over the energy range of 20 keV to 10 MeV with an expected spectroscopic resolution of 2 keV at 1 MeV (E/Delta-E = 500). The active detection element is a 215-cu cm high-purity n-type Ge crystal cooled to cryogenic temperatures by a passive radiative cooler. The geometric field of view (FOV) defined by the cooler is 170 deg FWFM. Burst data are stored directly in an onboard 2.75-Mb burst memory with an absolute timing accuracy of +/-1.5 ms. This capacity is sufficient to store the entire spectral data set of all but the largest bursts. In addition to burst measurements, the instrument will also study solar flares, search for possible diffuse background lines, and monitor the 511-keV positron annihilation radiation from the galactic center. The experiment is scheduled to be launched on a Delta II launch vehicle from Cape Canaveral on December 31, 1992.

Owens, A.↗

Ribbon Cable Strap Partly Free Of Backlash

Flexible ribbon cable strap carries heat and electrical signals across rotational shaft without creating backlash torques at both extremes of rotation through limited angular range. Keeps its flexibility and nonbacklash properties at cryogenic temperatures. Used to connect delicate equipment, such as movable infrared sensors, requiring precise positioning. Adapted to greater or lesser angular travel by changing its length and offset and bias of ribbon cables.

Farley, Rodger↗

COBE On-Orbit Engineering Performance, volume 1

The Cosmic Background Explorer (COBE) was successfully launched on Nov. 18, 1989. The Delta Launch Vehicle performed flawlessly, and observatory deployments occurred as planned. The dewar cover successfully deployed on day 4, as planned, and the cryogen temperature is currently at 1.41 K. All three instruments are operating and acquiring science data, and the Payload Operational Control Center (POCC)/Network support has been excellent. Various performance aspects of the COBE are presented in view graph form.

Source record↗

The effect of weld porosity on the cryogenic fatigue strength of ELI grade Ti-5Al-2.5Sn

The effect of weld porosity on the fatigue strength of ELI grade Ti-5Al-2.5Sn at cryogenic temperature was determined. A series of high cycle fatigue (HCF) and tensile tests were performed at -320 F on specimens made from welded sheets of the material. All specimens were tested with weld beads intact and some amount of weld offset. Specimens containing porosity and control specimens containing no porosity were tested. Results indicate that for the weld configuration tested, the fatigue life of the material is not affected by the presence of spherical embedded pores.

Rogers, P. R.↗

Strong, Ductile Rotor For Cryogenic Flowmeters

Improved magnetic flowmeter rotor resists cracking at cryogenic temperatures, yet provides adequate signal to magnetic pickup outside flowmeter housing. Consists mostly of stainless-steel alloy 347, which is ductile and strong at low temperatures. Small bead of stainless-steel alloy 410 welded in groove around circumference of round bar of stainless-steel alloy 347; then rotor machined from bar. Tips of rotor blades contain small amounts of magnetic alloy, and passage of tips detected.

Royals, W. T.↗

Performance of ceramic superconductors in magnetic bearings

Magnetic bearings are large-scale applications of magnet technology, quite similar in certain ways to synchronous machinery. They require substantial flux density over relatively large volumes of space. Large flux density is required to have satisfactory force density. Satisfactory dynamic response requires that magnetic circuit permeances not be too large, implying large air gaps. Superconductors, which offer large magnetomotive forces and high flux density in low permeance circuits, appear to be desirable in these situations. Flux densities substantially in excess of those possible with iron can be produced, and no ferromagnetic material is required. Thus the inductance of active coils can be made low, indicating good dynamic response of the bearing system. The principal difficulty in using superconductors is, of course, the deep cryogenic temperatures at which they must operate. Because of the difficulties in working with liquid helium, the possibility of superconductors which can be operated in liquid nitrogen is thought to extend the number and range of applications of superconductivity. Critical temperatures of about 98 degrees Kelvin were demonstrated in a class of materials which are, in fact, ceramics. Quite a bit of public attention was attracted to these new materials. There is a difficulty with the ceramic superconducting materials which were developed to date. Current densities sufficient for use in large-scale applications have not been demonstrated. In order to be useful, superconductors must be capable of carrying substantial currents in the presence of large magnetic fields. The possible use of ceramic superconductors in magnetic bearings is investigated and discussed and requirements that must be achieved by superconductors operating at liquid nitrogen temperatures to make their use comparable with niobium-titanium superconductors operating at liquid helium temperatures are identified.

Kirtley, James L., Jr.↗

Spaceborne Passive Radiative Cooler

Radiative coolers are passive refrigeration devices for satellites and space probes that provide refrigeration for an infrared or other type of detector that operates at cryogenic temperatures. Typically a cooler can supply 20 mW of cooling at about 85 K, and over 500 mW of cooling at about 165 K. The exact cooler temperatures and heat loads are dependent upon the clear field of view of the cooler to space. Some features of the Arthur D. Little passive radiative cooler are given.

Mathias, S.↗

SiC lightweight telescopes for advanced space applications. I - Mirror technology

A SiC based telescope is an extremely attractive emerging technology which offers the lightweight and stiffness features of beryllium, the optical performance of glass to diffraction limited visible resolution, superior optical/thermal stability to cryogenic temperatures, and the cost advantages of an aluminum telescope. SSG has developed various SiC mirrors with and without a silicon coating and tested these mirrors over temperature ranges from +50 C to -250 C. Our test results show less than 0.2 waves P-V in visible wavefront change and no hysteresis over this wide temperature range. Several SSG mirrors are representative of very lightweight SiC/Si mirrors including (1) a 9 cm diameter, high aspect ratio mirror weighing less than 30 grams and (2) a 23 cm diameter eggcrated mirror weighing less than 400 grams. SSG has also designed and analyzed a 0.6 meter SiC based, on axis, three mirror reimaging telescope in which the primary mirror weighs less than 6 kg and a 0.5 meter GOES-like scan mirror. SSG has also diamond turned several general aspheric SiC/Si mirrors with excellent cryo optical performance.

Anapol, Michael I.↗

Micromechanics thermal stress analysis of composites for space structure applications

This paper presents results from a finite element micromechanics analysis of thermally induced stresses in composites at cryogenic temperatures typical of spacecraft operating environments. The influence of microstructural geometry, constituent and interphase properties, and laminate orientation were investigated. Stress field results indicated that significant matrix stresses occur in composites exposed to typical spacecraft thermal excursions; these stresses varied with laminate orientation and circumferential position around the fiber. The major difference in the predicted response of unidirectional and multidirectional laminates was the presence of tensile radial stresses, at the fiber/matrix interface, in multidirectional laminates with off-axis ply angles greater than 15 deg. The predicted damage initiation temperatures and modes were in good agreement with experimental data for both low (207 GPa) and high (517 GPa) modulus carbon fiber/epoxy composites.

Bowles, David E.↗

Cryogenic monocrystalline silicon Fabry-Perot cavity for the stabilization of laser frequency

A 1.6 kg silicon monocrystal was used to make a Fabry-Perot optical cavity operated at cryogenic temperatures. High-resolution thermal expansion measurements were made as the silicon cooled to 4.2 K, in order to characterize the cavity as a length reference standard. A helium-neon laser was then locked to a transmission resonance at liquid-helium temperatures, and the laser frequency tracked the cavity resonance with error fluctuations at the level of 10 Hz/sq rt Hz in the bandwidth dc to 1 Hz. Implications of the combined set of data, thermal expansion plus frequency-tracking fluctuations, for using such a system as a frequency standard are discussed.

Richard, J.-P.↗

Conceptual thermal design and analysis of a far-infrared/mid-infrared remote sensing instrument

This paper presents the conceptual thermal design and analysis results for the Spectroscopy of the Atmosphere using Far-Infrared Emission (SAFIRE) instrument. SAFIRE has been proposed for Mission to Planet Earth to study ozone chemistry in the middle atmosphere using remote sensing of the atmosphere in the far-infrared (21-87 microns) and mid-infrared (9-16 microns) spectra. SAFIRE requires that far-IR detectors be cooled to 3-4 K and mid-IR detectors to 80 K for the expected mission lifetime of five years. A superfluid helium dewar and Stirling-cycle cryocoolers provide the cryogenic temperatures required by the infrared detectors. The proposed instrument thermal design uses passive thermal control techniques to reject 465 watts of waste heat from the instrument.

Roettker, William A.↗