Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Next-to-leading order corrections to e{sup +}e{sup -{yields}}W{sup +}W{sup -}Z and e{sup +}e{sup -{yields}}ZZZ

We calculate the one-loop electroweak corrections to e{sup +}e{sup -{yields}}W{sup +}W{sup -}Z and e{sup +}e{sup -{yields}}ZZZ and analyze their impacts on both the total cross section and some key distributions. These processes are important for the measurements of the quartic couplings of the massive gauge bosons which can be a window on the mechanism of spontaneous symmetry breaking. We find that even after subtracting the leading QED corrections, the electroweak corrections can still be large, especially as the energy increases. We compare and implement different methods of dealing with potential instabilities in the routines pertaining to the loop integrals. For the real corrections we apply a dipole subtraction formalism and compare it to a phase-space slicing method.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Weak corrections to associated Higgs-bottom quark production

In models with an enhanced coupling of the Higgs boson to the bottom quark, the dominant production mechanism in hadronic collisions is often the partonic subprocess, bg{yields}bH. We derive the weak corrections to this process and show that they can be accurately approximated by an 'improved Born approximation'. At the Tevatron, these corrections are negligible and are dwarfed by PDF and scale uncertainties for M{sub H}<200 GeV. At the LHC, the weak corrections are small for M{sub H}<500 GeV. For large Higgs boson masses, the corrections become significant and are {approx}18% for M{sub H{approx}}1 TeV at {radical}(s)=10 TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Medium corrections to the CP-violating parameter in leptogenesis

In two recent papers, it has been demonstrated that one can obtain quantum-corrected Boltzmann kinetic equations for leptogenesis using a top-down approach based on the Schwinger-Keldysh/Kadanoff-Baym formalism. These 'Boltzmann-like' equations are similar to the ones obtained in the conventional bottom-up approach but differ in important details. In particular there is a discrepancy between the CP-violating parameter obtained in the first-principle derivation and in the framework of thermal field theory. Here we demonstrate that the two approaches can be reconciled if causal n-point functions are used in the thermal field theory approach. The new result for the medium correction to the CP-violating parameter is qualitatively different from the conventional one. The analogy to a toy model considered earlier enables us to write down consistent quantum-corrected Boltzmann equations, for thermal leptogenesis in the standard model extended by three right-handed neutrinos, which include quantum statistical terms and medium-corrected expressions for the CP-violating parameter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photonic supersymmetric two-loop corrections to the muon magnetic moment

Photonic SUSY two-loop corrections to the muon magnetic moment are contributions from diagrams where an additional photon loop is attached to a SUSY one-loop diagram. These photonic corrections are evaluated exactly, extending a leading-log calculation by Degrassi and Giudice. Compact analytical expressions are provided and the numerical behavior is discussed. The photonic corrections reduce the SUSY one-loop result by 7%-9%. The new terms are typically around 10 times smaller than the leading logarithms, but they can be larger and have either sign in cases with large SUSY mass splittings. We also provide details on renormalization and regularization and on how to incorporate the photonic corrections into a full SUSY two-loop calculation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Next-to-leading order QCD corrections to a heavy resonance production and decay into top quark pair at the LHC

We present a complete next-to-leading order (NLO) QCD calculation to a heavy resonance production and decay into a top quark pair at the LHC, where the resonance could be either a Randall-Sundrum Kaluza-Klein graviton G or an extra gauge boson Z{sup '}. The complete NLO QCD corrections can enhance the total cross sections by about 80%-100% and 20%-40% for the G and the Z{sup '}, respectively, depending on the resonance mass. We also explore in detail the NLO corrections to the polar angle distributions of the top quark, and our results show that the shapes of the NLO distributions can be different from the leading order ones for the Kaluza-Klein graviton. Moreover, we study the NLO corrections to the spin correlations of the top quark pair production via the above process, and find that the corrections are small.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of two-photon corrections in the pp{yields}e{sup +}e{sup -} process: Hard rescattering mechanism

We investigate the two-photon corrections to the process pp{yields}e{sup +}e{sup -} at large momentum transfer, aimed to access the timelike nucleon form factors. We estimate the two-photon corrections using a hard rescattering mechanism, which has already been used to calculate the corresponding corrections to elastic electron-proton scattering. Using different nucleon distribution amplitudes, we find that the two-photon corrections to the pp{yields}e{sup +}e{sup -} cross sections in the momentum transfer range 5-30 GeV{sup 2} is below the 1% level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dispersion {gamma}Z-Box Correction to the Weak Charge of the Proton

We consider elastic scattering of electrons off a proton target. The parity-violating (PV) asymmetry arises at leading order in {alpha} due to interference of {gamma} and Z exchange. The radiative corrections to this leading mechanism were calculated in the literature and included in experimental analyses, except for {gamma}Z-box and cross-box contributions. We present here a dispersion calculation of these corrections in forward kinematics. We demonstrate that at the GeV energies of current PV experiments, such corrections are not suppressed by the small vector weak charge of the electron, as occurs in the atomic parity violation. Our results suggest that the current theoretical uncertainty in the analysis of the QWEAK experiment might be substantially underestimated, and more accurate accounts of the dispersion corrections are needed in order to interpret the PV data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ancilla-Free Quantum Error Correction Codes for Quantum Metrology

Quantum error correction has recently emerged as a tool to enhance quantum sensing under Markovian noise. It works by correcting errors in a sensor while letting a signal imprint on the logical state. This approach typically requires a specialized error-correcting code, as most existing codes correct away both the dominant errors and the signal. To date, however, few such specialized codes are known, among which most require noiseless, controllable ancillas. We show here that such ancillas are not needed when the signal Hamiltonian and the error operators commute, a common limiting type of decoherence in quantum sensors. We give a semidefinite program for finding optimal ancilla-free sensing codes in general, as well as closed-form codes for two common sensing scenarios: qubits undergoing dephasing, and a lossy bosonic mode. Lastly, we analyze the sensitivity enhancement offered by the qubit code under arbitrary spatial noise correlations, beyond the ideal limit of orthogonal signal and noise operators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pion-Induced Radiative Corrections to Neutron β Decay

In this work, we compute the electromagnetic corrections to neutron β decay using a low-energy hadronic effective field theory. We identify new radiative corrections arising from virtual pions that were missed in previous studies. The largest correction is a percent-level shift in the axial charge of the nucleon proportional to the electromagnetic part of the pion-mass splitting. Smaller corrections, comparable to anticipated experimental precision, impact the β-ν angular correlations and the β asymmetry. We comment on implications of our results for the comparison of the experimentally measured nucleon axial charge with first-principles computations using lattice QCD and on the potential of β decay experiments to constrain beyond-the-standard-model interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Perturbative Stability and Error-Correction Thresholds of Quantum Codes

Topologically ordered phases are stable to local perturbations, and topological quantum error-correcting codes enjoy thresholds to local errors. We connect the two notions of stability by constructing classical statistical mechanics models for decoding general Calderbank-Shor-Steane codes and classical linear codes. Our construction encodes correction success probabilities under uncorrelated bit-flip and phase-flip errors, and simultaneously describes a generalized ℤ 2 lattice-gauge theory with quenched disorder. We observe that the clean limit of the latter is precisely the discretized imaginary-time path integral of the corresponding quantum code Hamiltonian when the errors are turned into a perturbative 𝑋 or 𝑍 magnetic field. Motivated by error-correction considerations, we define general order parameters for all such generalized ℤ 2 lattice-gauge theories, and show that they are generally lower bounded by success probabilities of error correction. For CSS codes satisfying the low-density parity-check condition and with a sufficiently large code distance, we prove the existence of a low-temperature ordered phase of the corresponding lattice-gauge theories, particularly for those lacking Euclidean spatial locality and/or when there is a nonzero code rate. We further argue that these results provide evidence for stable phases in the corresponding perturbed quantum Hamiltonians, obtained in the limit of continuous imaginary time. To do so, we distinguish space- and timelike defects in the lattice-gauge theory. A high free-energy cost of spacelike defects corresponds to a successful “memory experiment” and suppresses the energy splitting among the ground states, while a high free-energy cost of timelike defects corresponds to a successful “stability experiment” and points to a nonzero gap to local excitations.

quantum error correction↗

Expanding Lorentz and spectrum corrections to large volumes of reciprocal space for single-crystal time-of-flight neutron diffraction

Evidence is mounting that potentially exploitable properties of technologically and chemically interesting crystalline materials are often attributable to local structure effects, which can be observed as modulated diffuse scattering (mDS) next to Bragg diffraction (BD). BD forms a regular sparse grid of intense discrete points in reciprocal space. Traditionally, the intensity of each Bragg peak is extracted by integration of each individual reflection first, followed by application of the required corrections. In contrast, mDS is weak and covers expansive volumes of reciprocal space close to, or between, Bragg reflections. For a representative measurement of the diffuse scattering, multiple sample orientations are generally required, where many points in reciprocal space are measured multiple times and the resulting data are combined. The common post-integration data reduction method is not optimal with regard to counting statistics. A general and inclusive data processing method is needed. In this contribution, a comprehensive data analysis approach is introduced to correct and merge the full volume of scattering data in a single step, while correctly accounting for the statistical weight of the individual measurements. Development of this new approach required the exploration of a data treatment and correction protocol that includes the entire collected reciprocal space volume, using neutron time-of-flight or wavelength-resolved data collected at TOPAZ at the Spallation Neutron Source at Oak Ridge National Laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid Cascading Outage Analysis of Extreme Events with Optimized Corrective Actions

Power system are vulnerable to extreme contingencies (like an outage of a major generating substation) that can cause significant generation and load loss and can lead to further cascading outages of other transmission facilities and generators in the system. Some cascading outages are seen within minutes following a major contingency, which may not be captured exclusively using the dynamic simulation of the power system. The utilities plan for contingencies either based on dynamic or steady state analysis separately which may not accurately capture the impact of one process on the other. We address this gap in cascading outage analysis by developing Dynamic Contingency Analysis Tool (DCAT) that can analyze hybrid dynamic and steady state behavior of the power system, including protection system models in dynamic simulations, and simulating corrective actions in post-transient steady state conditions. One of the important implemented steady state processes is to mimic operator corrective actions to mitigate aggravated states caused by dynamic cascading. This paper presents an Optimal Power Flow (OPF) based formulation for selecting corrective actions that utility operators can take during major contingency and thus automate the hybrid dynamic-steady state cascading outage process. The improved DCAT framework with OPF based corrective actions is demonstrated on IEEE 300 bus test system.

Cascading outage↗

Corrective Control to Handle Forecast Uncertainty: A Chance Constrained Optimal Power Flow

Higher shares of electricity generation from renewable energy sources and market liberalization is increasing uncertainty in power systems operation. At the same time, operation is becoming more flexible with improved control systems and new technology such as phase shifting transformers (PSTs) and high voltage direct current connections (HVDC). Previous studies have shown that the use of corrective control in response to outages contributes to a reduction in operating cost, while maintaining N-1 security. In this work, we propose a method to extend the use of corrective control of PSTs and HVDCs to react to uncertainty. We characterize the uncertainty as continuous random variables, and define the corrective control actions through affine control policies. This allows us to efficiently model control reactions to a large number of uncertainty sources. The control policies are then included in a chance constrained optimal power flow formulation, which guarantees that the system constraints are enforced with a desired probability. Lastly, by applying an analytical reformulation of the chance constraints, we obtain a second-order cone problem for which we develop an efficient solution algorithm. In a case study for the IEEE 118 bus system, we show that corrective control for uncertainty leads to a decrease in operational cost, while maintaining system security. Further, we demonstrate the scalability of the method by solving the problem for the IEEE 300 bus and the Polish system test cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Monte Carlo calculations of correction factors for plastic phantoms in clinical photon and electron beam dosimetry

The purpose of this study is to calculate correction factors for plastic water (PW) and plastic water diagnostic-therapy (PWDT) phantoms in clinical photon and electron beam dosimetry using the EGSnrc Monte Carlo code system. A water-to-plastic ionization conversion factor k{sub pl} for PW and PWDT was computed for several commonly used Farmer-type ionization chambers with different wall materials in the range of 4-18 MV photon beams. For electron beams, a depth-scaling factor c{sub pl} and a chamber-dependent fluence correction factor h{sub pl} for both phantoms were also calculated in combination with NACP-02 and Roos plane-parallel ionization chambers in the range of 4-18 MeV. The h{sub pl} values for the plane-parallel chambers were evaluated from the electron fluence correction factor {phi}{sub pl}{sup w} and wall correction factors P{sub wall,w} and P{sub wall,pl} for a combination of water or plastic materials. The calculated k{sub pl} and h{sub pl} values were verified by comparison with the measured values. A set of k{sub pl} values computed for the Farmer-type chambers was equal to unity within 0.5% for PW and PWDT in photon beams. The k{sub pl} values also agreed within their combined uncertainty with the measured data. For electron beams, the c{sub pl} values computed for PW and PWDT were from 0.998 to 1.000 and from 0.992 to 0.997, respectively, in the range of 4-18 MeV. The {phi}{sub pl}{sup w} values for PW and PWDT were from 0.998 to 1.001 and from 1.004 to 1.001, respectively, at a reference depth in the range of 4-18 MeV. The difference in P{sub wall} between water and plastic materials for the plane-parallel chambers was 0.8% at a maximum. Finally, h{sub pl} values evaluated for plastic materials were equal to unity within 0.6% for NACP-02 and Roos chambers. The h{sub pl} values also agreed within their combined uncertainty with the measured data. The absorbed dose to water from ionization chamber measurements in PW and PWDT plastic materials corresponds to that in water within 1%. Both phantoms can thus be used as a substitute for water for photon and electron dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Accuracy of Spencer-Attix cavity theory and calculations of fluence correction factors for the air kerma formalism

EGSnrc calculations of ion chamber response and Spencer-Attix (SA) restricted stopping-power ratios are used to test the assumptions of the SA cavity theory and to assess the accuracy of this theory as it applies to the air kerma formalism for {sup 60}Co beams. Consistent with previous reports, the EGSnrc calculations show that the SA cavity theory, as it is normally applied, requires a correction for the perturbation of the charged particle fluence (K{sub fl}) by the presence of the cavity. The need for K{sub fl} corrections arises from the fact that the standard prescription for choosing the low-energy threshold {Delta} in the SA restricted stopping-power ratio consistently underestimates the values of {Delta} needed if no perturbation to the fluence is assumed. The use of fluence corrections can be avoided by appropriately choosing {Delta}, but it is not clear how {Delta} can be calculated from first principles. Values of {Delta} required to avoid K{sub fl} corrections were found to be consistently higher than {Delta} values obtained using the conventional approach and are also observed to be dependent on the composition of the wall in addition to the cavity size. Values of K{sub fl} have been calculated for many of the graphite-walled ion chambers used by the national metrology institutes around the world and found to be within 0.04% of unity in all cases, with an uncertainty of about 0.02%.

61 RADIATION PROTECTION AND DOSIMETRY↗

Correction for patient table-induced scattered radiation in cone-beam computed tomography (CBCT)

Purpose: In image-guided radiotherapy, an artifact typically seen in axial slices of x-ray cone-beam computed tomography (CBCT) reconstructions is a dark region or ''black hole'' situated below the scan isocenter. The authors trace the cause of the artifact to scattered radiation produced by radiotherapy patient tabletops and show it is linked to the use of the offset-detector acquisition mode to enlarge the imaging field-of-view. The authors present a hybrid scatter kernel superposition (SKS) algorithm to correct for scatter from both the object-of-interest and the tabletop. Methods: Monte Carlo simulations and phantom experiments were first performed to identify the source of the black hole artifact. For correction, a SKS algorithm was developed that uses separate kernels to estimate scatter from the patient tabletop and the object-of-interest. Each projection is divided into two regions, one defined by the shadow cast by the tabletop on the imager and one defined by the unshadowed region. The region not shadowed by the tabletop is processed using the recently developed fast adaptive scatter kernel superposition (fASKS) method which employs asymmetric kernels that best model scatter transport through bodylike objects. The shadowed region is convolved with a combination of slab-derived symmetric SKS kernels and asymmetric fASKS kernels. The composition of the hybrid kernels is projection-angle-dependent. To test the algorithm, pelvis phantom and in vivo data were acquired using a CBCT test stand, a Varian Acuity simulator, and a Varian On-Board Imager, all of which have similar geometries and components. Artifact intensities and Hounsfield unit (HU) accuracies in the reconstructions were assessed before and after the correction. Results: The hybrid kernel algorithm provided effective correction and produced substantially better scatter estimates than the symmetric SKS or asymmetric fASKS methods alone. HU nonuniformities in the reconstructed pelvis phantom were reduced from 220 to 50 HU (i.e., 22%-5%). In the in vivo scans, the black hole artifact was reduced by up to 147 HU, a 73% improvement, and anatomical details in the prostate and rectum areas were made considerably more visible. Conclusions: Radiotherapy tabletops, which are generally flatter and larger than those used for diagnostic CT, can produce significant scatter-related artifacts. The proposed hybrid SKS algorithm accurately estimates scatter from both the object-of-interest and the patient tabletop, and resulting image uniformities and HU accuracies are greatly improved.

60 APPLIED LIFE SCIENCES↗

Small fields output factors measurements and correction factors determination for several detectors for a CyberKnife{sup Registered-Sign} and linear accelerators equipped with microMLC and circular cones

Purpose: The use of small photon fields is now an established practice in stereotactic radiosurgery and radiotherapy. However, due to a lack of lateral electron equilibrium and high dose gradients, it is difficult to accurately measure the dosimetric quantities required for the commissioning of such systems. Moreover, there is still no metrological dosimetric reference for this kind of beam today. In this context, the first objective of this work was to determine and to compare small fields output factors (OF) measured with different types of active detectors and passive dosimeters for three types of facilities: a CyberKnife{sup Registered-Sign} system, a dedicated medical linear accelerator (Novalis) equipped with m3 microMLC and circular cones, and an adaptive medical linear accelerator (Clinac 2100) equipped with an additional m3 microMLC. The second one was to determine the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors introduced in a recently proposed small field dosimetry formalism for different active detectors.Methods: Small field sizes were defined either by microMLC down to 6 Multiplication-Sign 6 mm{sup 2} or by circular cones down to 4 mm in diameter. OF measurements were performed with several commercially available active detectors dedicated to measurements in small fields (high resolution diodes: IBA SFD, Sun Nuclear EDGE, PTW 60016, PTW 60017; ionizing chambers: PTW 31014 PinPoint chamber, PTW 31018 microLion liquid chamber, and PTW 60003 natural diamond). Two types of passive dosimeters were used: LiF microcubes and EBT2 radiochromic films.Results: Significant differences between the results obtained by several dosimetric systems were observed, particularly for the smallest field size for which the difference in the measured OF reaches more than 20%. For passive dosimeters, an excellent agreement was observed (better than 2%) between EBT2 and LiF microcubes for all OF measurements. Moreover, it has been shown that these passive dosimeters do not require correction factors and can then be used as reference dosimeters. Correction factors for the active detectors have then been determined from the mean experimental OF measured by the passive dosimeters.Conclusions: Four sets of correction factors needed to apply the new small field dosimetry formalism are provided for several active detectors. A protocol for small photon beams OF determination based on passive dosimeters measurements has been recently proposed to French radiotherapy treatment centers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Transcranial phase aberration correction using beam simulations and MR-ARFI

Purpose: Transcranial magnetic resonance-guided focused ultrasound surgery is a noninvasive technique for causing selective tissue necrosis. Variations in density, thickness, and shape of the skull cause aberrations in the location and shape of the focal zone. In this paper, the authors propose a hybrid simulation-MR-ARFI technique to achieve aberration correction for transcranial MR-guided focused ultrasound surgery. The technique uses ultrasound beam propagation simulations with MR Acoustic Radiation Force Imaging (MR-ARFI) to correct skull-caused phase aberrations. Methods: Skull-based numerical aberrations were obtained from a MR-guided focused ultrasound patient treatment and were added to all elements of the InSightec conformal bone focused ultrasound surgery transducer during transmission. In the first experiment, the 1024 aberrations derived from a human skull were condensed into 16 aberrations by averaging over the transducer area of 64 elements. In the second experiment, all 1024 aberrations were applied to the transducer. The aberrated MR-ARFI images were used in the hybrid simulation-MR-ARFI technique to find 16 estimated aberrations. These estimated aberrations were subtracted from the original aberrations to result in the corrected images. Each aberration experiment (16-aberration and 1024-aberration) was repeated three times. Results: The corrected MR-ARFI image was compared to the aberrated image and the ideal image (image with zero aberrations) for each experiment. The hybrid simulation-MR-ARFI technique resulted in an average increase in focal MR-ARFI phase of 44% for the 16-aberration case and 52% for the 1024-aberration case, and recovered 83% and 39% of the ideal MR-ARFI phase for the 16-aberrations and 1024-aberration case, respectively. Conclusions: Using one MR-ARFI image and noa priori information about the applied phase aberrations, the hybrid simulation-MR-ARFI technique improved the maximum MR-ARFI phase of the beam's focus.

62 RADIOLOGY AND NUCLEAR MEDICINE↗