Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controllable loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Balance of Plant Modeling and Real-Time Hardware-in-the-Loop Integration with the Microreactor Automated Control System

The advent of novel microreactor technology has driven a focused effort to explore safety and efficiency improvements that can be achieved through the use of automated system control. Development of control strategies, especially for initial demonstration, requires an adequate surrogate environment to safely research failure modes and control integration with realistic hardware delay. However, efficiency gains from control strategies are improved when the scope of controller action is expanded to include system-level dynamics such as downstream heat extraction and mass flow. For this reason, a balance-of-plant (BOP) model of a representative microreactor system has been developed using the TRANsient Simulation Framework of Reconfigurable Models library in Modelica. This model captures a reactor and primary NaK coolant loop that represent corresponding system components of the Microreactor Applications Research Validation and EvaLuation (MARVEL) design as well as a secondary coolant loop and heat extraction representative of the Microreactor Agile Non-Nuclear Experimental Test Bed (MAGNET). This model configuration allows for hardware-in-the-loop (HIL) integration with microreactor automated control system (MACS) hardware in real time through a Python-based gRPC client. Real-time simulation of model performance with emulated hardware and communication delay suggests that under independent proportional-integral-derivative control of BOP model drum dynamics and downstream heat extraction, stable power load following is achievable. A slight delay in load following, filtering of high-frequency dynamics, and localized temperature fluctation suggest room for improvement through the development of higher-level control strategies. The simulated coupling of the MAGNET facility lays the groundwork for future digital twin analysis with a coupled MACS-MAGNET HIL demonstration.

McConnell, Jono [ORNL] (ORCID:0000000238984741)↗

Achieving 5,000-h and 8,000-h Low-PGM Electrode Durability on Automotive Drive Cycles

Whereas total Pt loading in anode and cathode catalysts below 0.125 mg cm −2 is required to meet the stringent cost target for automotive fuel cell systems (FCS) for light duty vehicles, low-loaded cathode catalysts are susceptible to unacceptable aging-related performance losses at high current densities. A framework model, validated by accelerated stress test data, has identified cell voltage, relative humidity (RH) and temperature as the key operating variables that affect degradation of a high-activity d-PtCo/C cathode catalyst with 0.1 mg cm −2 Pt loading. Drive cycle simulations indicate that these can be controlled by properly selecting the minimum FCS power, compressor-expander module (CEM) turndown, and stack coolant temperature. The optimum system parameters are 4-kW e minimum power for an 80-kW e FCS, CEM turndown of 12.5, and 66 °C average coolant exit temperature that combine to limit the maximum cell voltage to 850 mV and outlet RH to 90%–100%. Depending on Pt loading, the mismatch between actual and allowable degradation for 10% power loss over 5,000-h lifetime requires the stack to be oversized by 2.4%–5%, resulting in 8.4%–41% lower Pt utilization and 7.1%–20.5% penalty in stack cost. The corresponding results for 8,000-h lifetime are 10.3%-14% stack oversizing, 23%–51.8% lower Pt utilization, and 24.1%–35.4% stack cost penalty.

08 HYDROGEN↗

Assessing Customer Experience and Business Models around Price-to-Device Communication and Smart Control Pathways in CalFlexHub

California is facing three major challenges in electrical grid operation: renewable overgeneration, steep evening ramping, and growing peak demand. The state has identified dynamic retail price response as a key strategy evidenced by CPUC’s Dynamic Rates proceeding and CEC’s Load Management Standards. Furthermore, the CEC launched a $16M “California Load Flexibility Research and Deployment Hub (CalFlexHub)” administered by Berkeley Lab to accelerate price-response flexible load technologies in buildings and EV charging. There are more than 16 laboratory and field demonstration projects in CalFlexHub, each demonstrating innovative automated price-response technologies. CalFlexHub tests various pathways through which hourly price signals and triggered control commands are communicated to load-flexible devices such as smart thermostats, heat pumps, water heaters, and EVs. We identified seven unique communication and control pathways, which involve combinations of third-party cloud, device OEM’s cloud, building central gateway, and local controller in between the price server and the load-flexible devices. It is important for utilities and policy makers to understand the long-term implications of each pathway in designing future programs and creating related policies and mandates for market transformation. We propose an evaluation framework including the following aspects: ● Functionality: connectivity and uptime, resilience, and optimization; ● Customer experience: simplicity in setup, troubleshooting support, continuity, customer choice, first cost, and ongoing cost; ● Business model and scalability: advance interoperability, holistic solution, bridge unique gap, customer base, and value streams and pricing structures. In this paper, we identify emerging business models associated with each communication pathway and discuss their positive features and challenges from the above aspects.

Liu, Jingjing↗

Vehicle-to-manufacturing (V2M) system: A novel approach to improve energy demand flexibility for demand response towards sustainable manufacturing

The U.S. manufacturing sector accounts for 77% of the industrial energy consumption, but its participation in demand response (DR) programs is largely lagged behind. The limited flexibility in production scheduling under high capacity utilization and the lack of DR schemes that incorporate energy demand flexibility measures are deemed as major barriers. In this study, a framework of the interactive vehicles-to-manufacturing (V2M) energy sharing system is proposed to improve the energy demand flexibility of the aggregated system and enhance the DR effectiveness for manufacturers. The V2M-based DR scheme aims to reduce the energy cost by load shifting through joint production and energy sharing control, which can eventually promote manufacturing DR implementation even under high capacity utilization requirements and dynamic real-time electricity prices. The V2M system is modeled based on a discrete-Markov chain considering the complex interconnections among various manufacturing resources and multi-directional energy flows among manufacturing facilities, electric vehicles, and the power grid. Based on the system model, a mixed-integer nonlinear programming (MINLP) problem is formulated to identify the optimal DR scheme. The effectiveness of the proposed approach is validated through comparisons with traditional manufacturing DR schemes. Finally, the results show that a 2.1 to 6.5 times energy demand flexibility improvement and an additional 4.7% to 6.9% energy cost reduction can be achieved by the proposed approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying particle movement in a spout-fluidized bed with irregular feedstock morphology

Here, the spout-bed fluidization behavior of nonspherical, 140 μm SiC feedstock was quantified via particle image velocimetry for varying gas distributor geometries. A bench-scale, room-temperature fluidization setup was assembled to model a 50 mm fluidized bed chemical vapor deposition (FB-CVD) system, and fluidized bed motion was captured using a high-speed camera. Modular tips with varying inlet geometries were 3D printed and tested on the bench-scale rig using identical feedstock and gas flow rates in the range of 3.0–9.0 L/min. Fluidization behavior was quantified by extracting parameters of the bed velocity, frequency, dead time, and other measurements, which were ranked for each inlet geometry configuration tested. The results from this work demonstrate that changing the path of inlet gas flow can significantly change the hydrodynamics within a spout-fluidized bed under identical feedstock, loading, and flow rate conditions, potentially enabling experimental control of particle fluidization behavior for a given condition. Moreover, composite rankings of fluidization behavior for unique distributor geometries hold potential to guide the design of FB-CVD experiments for various engineering and scientific applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Combined Rotating Disk Slurry Electrodeposition–Spontaneous Galvanic Displacement for Pt-M (M = Co, Ni, and Cu) Catalyst Synthesis for the Oxygen Reduction Reaction in Alkaline Media

Here, platinum-modified first-row transition-metal catalyst (M = Ni, Co, and Cu) nanoparticles on a carbon black Vulcan XC-72R (CBV) support were synthesized using rotating disk slurry electrodeposition (RoDSE) followed by spontaneous galvanic displacement (SGD) reactions. These RoDSE–SGD catalysts were evaluated for the oxygen reduction reaction (ORR) in 0.1 M KOH using rotating disk electrode techniques. The Ni and Co RoDSEs were done by using an electrochemical applied potential of -0.75 V versus the RHE and for Cu, -0.80 V versus the RHE using a CBV slurry solution containing 0.1 M KClO 4 . These metal nanoparticles on CBV (M/CBV) catalysts were modified with a Pt precursor via a spontaneous galvanic displacement (SGD) reaction, producing a Pt-M/CBV material to catalyze the ORR in an alkaline medium. High-resolution scanning transmission electron microscopy (HR-STEM) analysis indicates that the PtM/CBV samples include M clusters and Pt single atoms. The ORR characterization measurements were done under a controlled temperature (25.0 °C) and with a mass loading of 100 μg/cm 2 on a glassy carbon (GC) rotating disk electrode at 1600 rpm. The PtCo/CBV showed the highest ORR mass activity of 0.741 A/mgPt at 0.90 V versus the reversible hydrogen electrode (RHE) compared with commercial Pt/CBV. The M/CBV RoDSE catalysts were also tested for the oxygen evolution reaction (OER), and Ni/CBV provided the lowest overpotential of 450 mV at 10 mA/cm 2 disk in 0.1 M KOH.

30 DIRECT ENERGY CONVERSION↗

Effects of canopy midstory management and fuel moisture on wildfire behavior

Abstract Increasing trends in wildfire severity can partly be attributed to fire exclusion in the past century which led to higher fuel accumulation. Mechanical thinning and prescribed burns are effective techniques to manage fuel loads and to establish a higher degree of control over future fire risk, while restoring fire prone landscapes to their natural states of succession. However, given the complexity of interactions between fine scale fuel heterogeneity and wind, it is difficult to assess the success of thinning operations and prescribed burns. The present work addresses this issue systematically by simulating a simple fire line and propagating through a vegetative environment where the midstory has been cleared in different degrees, leading to a canopy with almost no midstory, another with a sparse midstory and another with a dense midstory. The simulations are conducted for these three canopies under two different conditions, where the fuel moisture is high and where it is low. These six sets of simulations show widely different fire behavior, in terms of fire intensity, spread rate and consumption. To understand the physical mechanisms that lead to these differences, detailed analyses are conducted to look at wind patterns, mean flow and turbulent fluxes of momentum and energy. The analyses also lead to improved understanding of processes leading to high intensity crowning behavior in presence of a dense midstory. Moreover, this work highlights the importance of considering fine scale fuel heterogeneity, seasonality, wind effects and the associated fire-canopy-atmosphere interactions while considering prescribed burns and forest management operations.

54 ENVIRONMENTAL SCIENCES↗

Structured for success: conjugated polymer binders with tailored composition and architecture for lithium-ion batteries

Conjugated polymer binders are replacing conventional binders in lithium-ion batteries. Herein, we examine how molecular engineering and hierarchical nanostructuring govern binder functionality and electrochemical performance. Lithium-ion batteries (LIBs) are the leading energy storage technology, yet enhancing their energy density and cycle life remains critical. Significant progress has been made in high-capacity anodes and high-voltage cathodes, but their performance is hindered by electrode degradation, where it is related to the behaviors of binders at the surface and interface. Conventional non-conductive binders like poly(vinylidene difluoride) (PVDF), combined with conductive additives, often fail to maintain electrical pathways under repeated volume changes. Alternatively, conjugated polymer binders have emerged as a superior alternative, simultaneously offering intrinsic conductivity, mechanical flexibility, and strong adhesion through π-conjugated backbones and functional groups. Their tunable molecular structure enables efficient electron/ion transport while mitigating electrode cracking. Additionally, the development of hierarchically ordered nanostructures in conjugated polymer binder can further enhance their electrochemical performance. This review examines the design principles of conjugated polymer binders, focusing on molecular engineering and nanostructural control to optimize their performance in high-loading electrodes, such as silicon-based anodes. By addressing key challenges in binder functionality, these advanced materials pave the way for next-generation high-energy-density LIBs.

Jin, Xiuyu↗

Fast ion confinement in the presence of core magnetic islands in Wendelstein 7-X

The effect of magnetic islands in the core region of Wendelstein 7-X (W7-X) on fast ion confinement is explored through simulations with the BEAMS3D code. A magnetic configuration where the n/m = 5/5 island chain is shifted to r/a ~ 0.7 allows the exploration of core island physics in W7-X. The control coil system on W7-X allows the tuning of the island size either increasing the island width or decreasing it. A coupling of the BEAMS3D code to the FIELDLINES code provides a versatile mechanism for incorporating magnetic islands and stochastic regions into the BEAMS3D code. Collisionless simulations suggest that the presence of core islands degrade the confinement of passing particles in the region of the island chain. Full neutral beam simulations of W7-X show a similar behavior with confinement decreasing as the island width is increased. Comparisons between a vacuum magnetic field and low beta HINT2 simulation are made showing similar fast ion behavior. Measurements of lost fast ions in W7-X confirm this trend with the control coil suppressed island configuration showing lower losses than that with no control coils applied. Simulations of fast ion wall loads are performed suggesting no drastic change in loss pattern and a slight reduction in losses with minimized islands.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhancement of Unsteady and 3D Aerodynamics Models using Machine Learning

Unsteady aerodynamics will be an important part of the floating wind turbines of the future operating under high shear across the rotor disk coupled with platform motion and atmospheric turbulence. We develop an unsteady aerodynamics and dynamic stall model using a long short-term memory variant of recurrent neural networks. The neural network model is trained using the oscillating airfoil data set from Ohio State University. The predictions from our machine learning (ML)-based model show good agreement with the experimental data and other state-of-the-art dynamic stall models for a wide range of airfoils, Reynolds numbers and reduced frequencies. In some cases the predictions are better than the Beddoes-Leishman model implementation in OpenFAST, when using the default coefficients. The ML-based model is also able to capture the key physics associated with dynamic stall, such as the precedence of moment stall before lift stall and cycle-to-cycle variations in the aerodynamic response. The new unsteady aerodynamics model is expected to improve prediction of fatigue loads for yaw-based wake-steering control scenarios in actuator-line and actuator-disc simulations of wind farms. Our methodology for training the ML-model provides a pathway for improving design level tools using high-fidelity computational fluid dynamics (CFD) simulations in the future.

17 WIND ENERGY↗

Small Hydropower Plant Response Improvement Using Energy Storage

Small hydropower plants contribute significantly to global power generation. However, due to limited storage, these can have low ramping capacity and poor load-frequency regulation. These can prevent small hydropower plants from being used in isolated grids as backup power to critical loads and rural areas. In this paper, a control architecture for frequency control is proposed that facilitates the use of energy storage to improve the response of standalone small hydropower plants. The frequency controller generates power commands using proportional control on frequency deviation and a user-defined power setpoint, and this incorporates with a current controller that facilitates power injection. The distinctive feature of the controller design is that it takes into account frequency thresholds and storage constraints to enable power injections, and it provides the capability to perform automated and manual recharge of the energy storage. Simulations using detailed nonlinear models demonstrate the improved performance of the hydropower with energy storage using the proposed controller. Automated and manual recharge and the impact of the energy storage constraints on the performance of the hydropower plant are demonstrated.

13 HYDRO ENERGY↗

VSC-HVDC Interties for Urban Power Grid Enhancement

Urban power grids are facing many operational and expansion challenges to meet further demand growth and increased reliability requirements. Advanced transmission technologies have been considered by the electric utilities to effectively increase the utilization of existing infrastructure and operational flexibility. The focus of this paper is on VSC-HVDC technologies for urban power grid enhancement and modernization. First, a potential technical scheme is proposed for converting an existing AC circuit to DC operation, which could boost the power transfer capability of the critical transmission corridor and increase network operational flexibility. Second, this paper proposes three operation modes for the VSC-HVDC interties in urban power grids corresponding to normal, emergency and island operating conditions, respectively. An integrated, adaptive emergency control strategy (AEC) is proposed that can enable adaptive power flow responses of the VSC-HVDC intertie under varying system operating conditions and critical contingencies. The flexibility and effectiveness of the proposed operational principles of urban VSC-HVDC intertie and the corresponding control strategies are verified in PSCAD/EMTDC using a realistic urban power grid in China.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Meso-Structured Polymer Electrolyte Fuel Cell Electrode

Increasing the utilization of Pt and Pt alloy catalysts in polymer electrolyte fuel cell cathodes is critical to improving the high power density operation, particularly at low Pt loadings. State of the art electrodes are fabricated in an ink deposition process that leads to uncontrolled electrode architecture with random aggregates of functional domains (catalyst, ionomer, and pore volume) (1). The randomness in the domains induces high tortuosity transport pathways for ions and fluids, which cause severe transport resistance during high current density operation. Thin ionomer films cause additional transport resistance and poisoning of the Pt catalyst, which becomes more significant at low Pt loadings. Reducing the amount of ionomer in the catalyst domain without affecting the ionic transport resistance is key to improving the utilization of the Pt and reducing the transport resistance at low Pt loading. Rational design of the electrode structure with controlled low tortuous ionic transport pathways could improve performance. The introduction of the ionomer pathways could also enable reduction of the ionomer volume in the catalyst domain, reducing the transport resistance. Middelmen et al. proposed electrode structures consisting of aligned components in a low tortuosity configuration to improve performance (2). In this work, we present an alternative electrode structure based on a vertically aligned array of Nafion pillars in the cathode catalyst layer, as shown in Figure 1a. Figure 1b shows the SEM image of the Nafion pillars. Furthermore, Pt supported on carbon catalyst was deposited on the Nafion pillars to fabricate a meso-structured electrode. Nafion pillars provide high conductive and low tortuous pathways for protons, reducing the effective transport distance, and enabling reduction of the ionomer binder in the catalyst domain.

25 ENERGY STORAGE↗

Connected Loads – Grid Connected Appliances: Commercial Refrigeration System Fault Detection and Diagnostics

As one of the most energy-intensive end-uses in the commercial buildings sector, supermarkets consume around 50 kWh/ft 2 (or 537.6 kWh/m 2 ) of electricity annually, or more than 2 million kWh of electricity per year for a typical store. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40–60% of its total electricity usage and is equivalent to about 2–3% of the total energy consumed by commercial buildings in United States, or around 0.5 quadrillion Btu (or 0.53 quadrillion KJ). Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Current supermarket refrigeration systems rely on high global warming potential hydrofluorocarbon refrigerants. Reducing refrigerant usage or using environment friendly alternatives can result in significant climate benefits. Transcritical CO2 refrigeration systems have attracted more attention in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in commercial buildings such as supermarkets. The refrigeration system can also be adapted to handle flexible building loads and be integrated into grid response transactive control to balance the supply and demand of the electric grid. Even minor improvements in the efficiency and operational reliability of supermarket refrigeration systems can create significant value in terms of saving energy, improving food quality, protecting the environment, reducing carbon footprint, and enhancing electric grid resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Connected Loads – Grid Connected Appliances: Deployment IoT Solution for Fault Detection and Diagnostics

As one of the most energy-intensive end-uses in the commercial buildings sector, supermarkets consume around 50 kWh/ft 2 ( or 537.6 kWh/m 2 ) of electricity annually, or more than 2 million kWh of electricity per year for a typical store. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40–60% of its total electricity usage and is equivalent to about 2–3% of the total energy consumed by commercial buildings in United States, or around 0.5 quadrillion Btu (or 0.53 quadrillion KJ). Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Current supermarket refrigeration systems rely on high global warming potential hydrofluorocarbon refrigerants. Reducing refrigerant usage or using environment friendly alternatives can result in significant climate benefits. Transcritical CO2 refrigeration systems have attracted more attention in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in commercial buildings such as supermarkets. The refrigeration system can also be adapted to handle flexible building loads and be integrated into grid response transactive control to balance the supply and demand of the electric grid. Even minor improvements in the efficiency and operational reliability of supermarket refrigeration systems can create significant value in terms of saving energy, improving food quality, protecting the environment, reducing carbon footprint, and enhancing electric grid resilience. For decarbonization, the new administration has set a target to reduce greenhouse gas emissions by 50– 52% by 2030 and targeting a carbon-neutral economy by 2050. For electrification, the goal is to achieve 100% clean electricity by 2035. Such decarbonization and electrification in the building sector require that energy consumption in buildings be reduced significantly. Therefore, the building sector must continuously adopt new technologies to achieve its energy and carbon emission goals. One of the most fundamental technologies is the Internet of Things (IoT). IoT has proven to be an effective solution for the building domain, including building information/energy modeling, smart buildings, etc. Although much progress has been made in the development of IoT-based building energy systems, there is still a lack of reliable, scalable, and affordable IoT-based automated fault and degradation diagnostics (AFDDs) solutions. Such solutions would enable deployment of advanced algorithms into real systems to archive the projected energy benefits. This study reviews existing IoT solutions developed for building energy– related application and developed a simple but effective AFDD IoT deployment solution, including developing a suitable IoT architecture and conducting easy and scalable deployment by leveraging a common cloud-based IoT service.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Metallurgical and mechanical characterization of ATP-5 aluminum alloys for minimizing machining distortion

ATP-5 aluminum alloy was considered as an alternative to 6061-T651 aluminum alloy to minimize machining distortion. ATP-5 is a proprietary cast alloy that is compositionally similar to 5083 aluminum and is purported to have excellent machinability, stability, and corrosion response. Dimensional stability tests, mechanical testing, chemical analysis, microstructural analysis, and fractography were completed to understand the metallurgy of the ATP-5 alloy and assess its potential as a 6061-T651 alloy alternative. Ultimately, the ATP-5 was found to retain dimensional stability issues, albeit to a lesser extent, relative to the 6061-T651 alloy. Combined with the residual cast structure observed microstructurally and lot-to-lot mechanical property variation, the alloy was deemed not suitable for a structural application. Alternative uses of ATP-5 include tooling, molds, vacuum chucks, fixtures, and jigs, where the material can shine in non-load bearing applications with a need for dimensional control and machinability.

36 MATERIALS SCIENCE↗

Peer-to-peer communication control for resilient operations of networked cyberphysical systems

This report includes two main accomplishments of the peer-to-peer communication control for resilient operation of networked microgrids project in FY24, which include a scheme for cyberattack-aware coordination of networked microgrids for supporting voltages of bulk power systems and a scheme for price signal-based operations of EV-rich networked microgrids with mixed ownership. First, the cyberattack-aware scheme enables networked microgrids to distributedly determine the amount of reactive power injection to support the voltage of bulk power system (BPS) in a fair manner. In this scheme, a risk-informed algorithm is presented to generate the peer-to- peer (P2P) communication graph with minimal risk of attack on communication links. To deal with cyberattacks on MG controllers, the resilient consensus algorithm (CA) is utilized for MG controllers to robustly estimate the total reactive power headroom, from which the MGs can accurately provide the needed amount of reactive power injection for supporting the voltage of BPS. The CA implementation and performance within the P2P communication framework are demonstrated on the IEEE 39-bus system with 6 microgrids contained in the distribution feeder under different cyberattack scenarios. Second, the price-based scheme enables the usage of the real-time price signal for the operations of electric vehicle (EV)-rich networked-microgrids with mixed ownership, in which not all the microgrids can communicate with the distribution system operator (DSO). In this scheme, a max consensus is introduced to enable the real-time price signal to be propagated from the DSO to all the microgrids, from which each microgrid controller will manage the DERs to balance the load demand and the power injection from the EV charging stations within its microgrid. Numerical results over one day with 288 slots of 5-minute intervals on the modified 123-node test feeder including 3 microgrids with high penetration of EV are presented to evaluate how the price signal affects the operations of networked microgrids under different charging strategies of the EV charging stations. The result indicates that our proposed EVCS (dis)charging strategy, which leverages the flexibility of EVs to support the grid through discharging during peak demand, proves to be a cost-effective solution that reduces operational costs while improving the social welfare of EV charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗