Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “control algorithm”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) (Final Scientific/Technical Report)

This report summarizes the activities conducted under the DOE VTO funded project DE- EE0008451, where ABB Inc. (ABB), in collaboration with Idaho National Laboratory (INL), APS Global (APS), and XOS Trucks (XOS) pursued the development of a cyber-resilient extreme fast charging (XFC) management system. This project entitled Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) focuses on a resilient architecture for smart charging EV Supply Equipment (EVSE) device control and Coordinated Anomaly Detection System (CADS) features that can be added at the charging site depot level to increase cybersecurity. The project was split into two budget periods focused first on developing the threat model and resilient control concepts and second on testing, improving, and validating those developed resilient control algorithms and features with a focus on key vulnerabilities identified during the threat assessment portion of the project. During the first budget period of the CyberX project, the ABB led team focused on activities to identify, model, and quantitatively prioritize high-impact attack scenarios with potential cyber-physical effects while also modeling and developing concepts for a resilient control system that could securely address integration of DERs and other resources with EV charging. Development of the security focused XFC management system (XMS) was accomplished first by offline simulation using a developed XFC station or depot with 480V input level and simulating measurement inputs to monitoring and control systems in concept development. A representative distribution grid model was developed supporting an EV charging site model with BESS and 6 general EV charging models. These EV charging models allowed multiple configurations of charging level, multiple connected protection and measurement devices, and simulation function to show general compromise of EV, BESS, and protection features based on parallel threat analysis. During the second budget period, the EV site and supporting systems model was developed in more detail and converted from offline model to real-time to real-time with EV charging hardware in the loop (HIL). The resilient control architecture developed as concept in the first part of the project was further tested and validated for integration of local energy resources and XFC charging station site equipment while maintaining cybersecure operating principles. The proposed resilient architecture for smart charging and cybersecurity features consists of two main concepts developed and tested within the project. The first concept is an XFC management system (XMS) consisting of a hardware gateway, software platform, and Supervisory Control and Data Acquisition (SCADA) or Distribution Management System integration components. The second concept is a Coordinated Anomaly Detection System (CADS) which forms a primarily software-related subsystem of the total CyberX solution focused on monitoring system measurements, estimation of measurement states, and predicting current at the utility point of interaction based on machine learning for anomaly detection.

33 ADVANCED PROPULSION SYSTEMS↗

Guidance and control analysis of the entry of a lifting body personnel launch vehicle

NASA is currently involved in definition studies of a Personnel Launch System (PLS) that could be used to transport people to and from low-earth orbit. This vehicle would serve both to complement the Space Shuttle and to provide alternative access to space in the event the Space Shuttle fleet were unavailable for a prolonged period. The PLS would consist of a manned spacecraft launched by an expendable vehicle, e.g., Titan 4. One promising candidate for the manned component of the PLS is the NASA Langley Research Center HL-20 lifting body. Many studies are currently underway to assess this vehicle, and one of the main areas of study is the development of the capability to successfully enter, glide to the landing site, and land. To provide this capability, guidance and control algorithms have been developed, incorporated into a six-degree-of-freedom simulation, and evaluation in the presence of off-nominal atmospheric conditions, consisting of both density variations and steady-state winds. In addition, the impact of atmospheric turbulence was examined for the portion of flight from Mach 3.5 to touchdown. This analysis showed that the vehicle remained controllable and could successfully land even in the presence of off-nominal atmospheric conditions.

Powell, Richard W.↗

Experimental Testing of Advanced Generalized Predictive Control for Stability Augmentation and Vibration Reduction of Tiltrotor Aircraft

Generalized Predictive Control (GPC) is an advanced form of an adaptive control algorithm that uses experimentally acquired data to determine the input-output relationship of complex systems through a process called system identification (system ID). GPC has historically been applied to wind tunnel tests of dynamically-scaled tiltrotor aircraft for stability augmentation and vibration reduction since the complex nature of these dynamic systems does not lend itself well to traditional control theory. Advanced GPC (AGPC) improves upon traditional GPC by enabling self-adaptation as conditions change from those used to acquire the system ID and controller performance would normally erode. The present research expands upon previous analytical development and demonstration of AGPC with experimental demonstration. To support AGPC, this present work also identifies and describes figures of merit that define a good working controller and quantifies the uniqueness of the control inputs and quality of the system ID parameters. The present research demonstrates that AGPC consistently performs better than traditional GPC and can successfully adapt to changing conditions.

Active Controls↗

Experimental Testing of Advanced Generalized Predictive Control for Stability Augmentation and Vibration Reduction of Tiltrotor Aircraft

Generalized Predictive Control (GPC) is an advanced form of an adaptive control algorithm that uses experimentally acquired data to determine the input-output relationship of complex systems through a process called system identification (system ID). GPC has historically been applied to wind tunnel tests of dynamically-scaled tiltrotor aircraft for stability augmentation and vibration reduction since the complex nature of these dynamic systems does not lend itself well to traditional control theory. Advanced GPC (AGPC) improves upon traditional GPC by enabling self-adaptation as conditions change from those used to acquire the system ID and controller performance would normally erode. The present research expands upon previous analytical development and demonstration of AGPC with experimental demonstration. To support AGPC, this present work also identifies and describes figures of merit that define a good working controller and quantifies the uniqueness of the control inputs and quality of the system ID parameters. The present research demonstrates that AGPC consistently performs better than traditional GPC and can successfully adapt to changing conditions.

Active Controls↗

A general algorithm for relating ground trajectory distance, elapsed flight time, and aircraft airspeed and its application to 4-D guidance

A general solution using an elliptic integral approximation which relates flight time, aircraft airspeed, and ground distance on straight-line and circular-arc trajectory segments is developed. The solution procedure is applicable to both constant and accelerating aircraft flight. In addition, wind shear including both magnitude and heading change is incorporated in the solution. The solution equations are used in a four-dimensional (4-D) control algorithm where both flight time and final airspeed are specified. The results show that the algorithm converges rapidly and accurately.

Foudriat, E. C.↗

DISTRI: Distributed Multi-Facility HPC Simulator (DISTRI) v2.1

DISTRI is an advanced network simulator designed for multi-facility computational infrastructures with agentic behavior. It simulates HPC facilities where computational resources act as autonomous agents, making intelligent decisions about job scheduling, load balancing, and resource allocation. The simulator focuses on developing and testing decentralized algorithms that promote resilience and efficiency in multi-facility environments. Key Features: - Agentic Resource Behavior: Processors and DTNs act as autonomous agents with decision-making capabilities - Pheromone-Based Load Balancing: Decentralized load balancing inspired by ant colony optimization - Dual Topology Support: Mesh (normal operations) and Dumbell (network testing) topologies - Comprehensive TCP Simulation: Realistic TCP implementations with multiple congestion control algorithms - Failure Resilience Testing: Processor failure simulation with automatic job reassignment - Extensive Visualization: Detailed performance analysis and metrics collection - Research-Ready: Designed for algorithm development and benchmarking

Bez, Jean Luca [Lawrence Berkeley National Laborat↗

Model-predictive optimal control of ferrofluidic microrobots in three-dimensional space

Ferrofluid microrobots have emerged as promising tools for minimally invasive medical procedures. Their unique properties to navigate complex fluids and reach otherwise inaccessible regions of the human body have enabled new applications in targeted drug delivery, tissue engineering, and diagnostics. Here, this paper proposes a model-predictive controller for the external magnetic manipulation of ferrofluid microrobots in three dimensions (3D). The internal optimization routine of the controller determines appropriate changes in the applied electromagnetic field to minimize the deviation between the actual and desired trajectories of the microrobot. A linear system governing locomotion is derived and used as the equality constraints of the optimization problems associated with the feedback index. In addition to ferrofluid droplets, the controller presented in this work may be applied to other magnetically-pulled microrobots. Several experiments are performed to validate the controller and showcase its ability to adapt to changes in system parameters such as the desired tracking trajectory and the size, orientation, deformation, and velocity of the microrobot. The accuracy of the controller is analyzed for each experiment, and the average error is found to be within 0.25 mm for small velocities. An additional experiment is performed to demonstrate significant improvement over a PID controller that is optimally tuned using Bayesian optimization. The results presented in this paper suggest that the proposed control algorithm could enable new microrobotic capabilities in minimally invasive medical procedures, lab-on-a-chip applications, and microfluidics.

60 APPLIED LIFE SCIENCES↗

Towards Erecting Straighter Lightweight Towers on the Moon Using Deployable Guy Wires

This paper reports our static stability test findings for a simple guy wire system to correct the natural lateral deflections of an 8.5m tall, compact deployable composite tower intended to support exploration of lunar permanently shadowed regions by nearby robotic assets. Deployable composite booms with microgravity flight heritage are currently being investigated at NASA Langley Research Center (LaRC) and Massachusetts Institute of Technology(MIT)’s Space Resources Workshop for their potential to be vertically deployed in the lunar gravity field, in support of NASA’s Artemis campaign. These applications include vertical solar arrays and the provision of elevated lines-of-sight to science or engineering payloads on landers and rovers, in support of nearby or distant crewed or robotic assets exploring scientifically interesting and hard to reach areas. Useful elevated payloads include radio repeaters, remote sensing and imaging, navigation and power beaming systems. However, while these lightweight booms have an excellent height to mass ratio, they typically exhibit slight axial curvature upon deployment resulting in appreciable lateral dead-load deflection of the tip mass relative to the tower base. This static deflection increases with tower height and tip mass, not only constraining the value delivered by the tower but also endangering its integrity. To develop a competitive, lightweight deployable composite boom tower, a capability to correct static deflections during and after deployment may be required. This paper presents a pathfinder deployable guy wire stability system for the MIT / LaRC self-erecting composite boom lunar tower that provides real time measurements, maintains tension passively, and can serve as a reconfigurable platform to test new guy wire components, configurations and control algorithms. Using a validated, calibrated photogrammetry system, the natural lateral deflection of the boom tip relative to the boom base at different deployed heights in Earth’s gravity field was recorded. With real-time tension measurements it was found that guy wires can significantly reduce the tip deflection of a deployable composite boom under dead load. Specifically, we found that (1) control capability is greatest where it is needed most, i.e. for the lever arm closest to being opposite the direction of deflection, and (2) for a tower height of at least 8.5 m and arm length of at least 60 cm, a solution of differential tension in all three arms exists and, in principle, provides sufficient control capability to correct or significantly reduce boom deflections. We also found that natural deflections occur almost entirely out-of-plane of the seams of the boom cross-section, which was expected, and that the natural boom tip lateral deflection under dead load upon deployment was ~5% of boom deployed length, unexpectedly exceeding the manufacturing acceptance specification of 1%.Ongoing and future collaborative work between LaRC and MIT includes the further investigation of the unexpected lateral deflection, testing of alternative guy wire system designs at higher tensions and higher deployed heights, as well as trade studies of costs and benefits of an optimized integrated guywire system compared to other types of static stability solutions.

lunar towers↗

Safe microburst penetration techniques: A deterministic, nonlinear, optimal control approach

A relatively large amount of computer time was used for the calculation of a optimal trajectory, but it is subject to reduction with moderate effort. The Deterministic, Nonlinear, Optimal Control algorithm yielded excellent aircraft performance in trajectory tracking for the given microburst. It did so by varying the angle of attack to counteract the lift effects of microburst induced airspeed variations. Throttle saturation and aerodynamic stall limits were not a problem for the case considered, proving that the aircraft's performance capabilities were not violated by the given wind field. All closed loop control laws previously considered performed very poorly in comparison, and therefore do not come near to taking full advantage of aircraft performance.

Psiaki, Mark L.↗

50 MW Segmented Ultralight Morphing Rotors for Wind Energy

A multi-institutional team designed a 50 Megawatt (MW) rated wind turbine featuring downwind aeroelastic morphing to reduce blade loads and allow an ultralight segmented rotor (mass reduction of about 25% compared to a conventional upwind rotor). The team used a control co-design approach with state-of-the art simulations including for the rotor and tower design using non-linear fluid-structure interactions and control algorithms, and the team also designed, built, and field-tested an aeroelastically-scaled downwind rotor to demonstrate this novel technology and validate the design tool fidelity. In a follow-on phase, these results were used along with an updated Levelized Cost Of Energy (LCOE) methodology to co-design a more detailed set of 25 MW rated turbine designs (including individual pitch control) based on minimum LCOE with highly flexible blades for an Atlantic Ocean offshore fixed-bottom design targeted towards market technology evaluation. A set of upwind and downwind designs at 25 MW rated scales were found to provide the best LCOE, with strong improvements over all previous offshore reference turbines (NREL 5MW, DTU 10 MW and IEA 15 MW). The optimized design would represent the world’s largest offshore turbine design, which combines several state-of-the-art structural, aerodynamic, and control technologies into a new and optimized system concept.

17 WIND ENERGY↗

Analysis of MHD stability and active mode control on KSTAR for high confinement, disruption-free plasma

Long-pulse plasma operation at high normalized beta, $β_N$, above the $\textit{n}$= 1 ideal MHD no-wall stability limit in KSTAR is presently limited by tearing instabilities rather than resistive wall modes. H-mode plasma operation during the recent KSTAR device campaign produced discharges having strong $\textit{m/n}$= 2/1 tearing instabilities at $β_N$ lower than the ideal MHD no-wall beta limit. The unstable tearing mode consequently reduced plasma confinement and toroidal plasma rotation significantly. We report the experiment confirmed that an extended duration of electron cyclotron heating (ECH) at the initial phase of the discharge plays a critical role in mode destabilization. To study destabilizing mechanisms that affect the mode growth, the stability of the observed tearing modes from plasmas with significantly different $β_N$ is computed by using the resistive DCON code and the M3D-C 1 code. Equilibrium reconstructions that include constraints from internal profile diagnostics, and computed fast particle pressure are used as input for reliable computation of stability. The classical tearing stability index, Δ', from resistive DCON is computed to be unstable when the island is fully saturated with large amplitude, while the unstable mode is not computed by M3D-C 1 . The modified Rutherford equation (MRE) describing the evolution of the island width has been constructed for KSTAR plasmas by using plasma parameters computed by the TRANSP code. The MRE model estimates a saturated island width corresponding to ~10% of the plasma minor radius for equilibrium at high $β_N$ 3 having a stable Δ' from the resistive DCON. In preparation for long-pulse plasma operation at higher beta utilizing increased plasma heating power, a resistive wall mode (RWM) active feedback control algorithm has been completed and enabled on KSTAR. To accurately determine the $\textit{n}$= 1component produced by RWMs, an algorithm has been developed that includes magnetic sensor compensation of the prompt applied field and the field from the induced current on the passive conductors. Use of multiple toroidal sensor arrays is enabled by modifying the sensor toroidal angles assumed in mode decomposition to include the effect of varied mode helicities in the outboard region where the mode measurement is made. This analysis on stability, transport, and control provides the required foundation for disruption prediction and avoidance research on KSTAR.

resistive wall mode (RWM)↗

Validation of an Integrated Airframe and Turbofan Engine Simulation for Evaluation of Propulsion Control Modes

The National Aeronautics and Space Administration (NASA) has developed independent airframe and engine models that have been integrated into a single real-time aircraft simulation for piloted evaluation of propulsion control algorithms. In order to have confidence in the results of these evaluations, the integrated simulation must be validated to demonstrate that its behavior is realistic and that it meets the appropriate Federal Aviation Administration (FAA) certification requirements for aircraft. The paper describes the test procedures and results, demonstrating that the integrated simulation generally meets the FAA requirements and is thus a valid testbed for evaluation of propulsion control modes.

aircraft engine simulation↗

Validation of an Integrated Airframe and Turbofan Engine Simulation for Evaluation of Propulsion Control Modes

The National Aeronautics and Space Administration (NASA) has developed independent airframe and engine models that have been integrated into a single real-time aircraft simulation for piloted evaluation of propulsion control algorithms. In order to have confidence in the results of these evaluations, the integrated simulation must be validated to demonstrate that its behavior is realistic and that it meets the appropriate Federal Aviation Administration (FAA) certification requirements for aircraft. The paper describes the test procedures and results, demonstrating that the integrated simulation generally meets the FAA requirements and is thus a valid testbed for evaluation of propulsion control modes.

aircraft engine simulation↗

Automation in the Space Station module power management and distribution Breadboard

The Space Station Module Power Management and Distribution (SSM/PMAD) Breadboard, located at NASA's Marshall Space Flight Center (MSFC) in Huntsville, Alabama, models the power distribution within a Space Station Freedom Habitation or Laboratory module. Originally designed for 20 kHz ac power, the system is now being converted to high voltage dc power with power levels on a par with those expected for a space station module. In addition to the power distribution hardware, the system includes computer control through a hierarchy of processes. The lowest level process consists of fast, simple (from a computing standpoint) switchgear, capable of quickly safing the system. The next level consists of local load center processors called Lowest Level Processors (LLP's). These LLP's execute load scheduling, perform redundant switching, and shed loads which use more than scheduled power. The level above the LLP's contains a Communication and Algorithmic Controller (CAC) which coordinates communications with the highest level. Finally, at this highest level, three cooperating Artificial Intelligence (AI) systems manage load prioritization, load scheduling, load shedding, and fault recovery and management. The system provides an excellent venue for developing and examining advanced automation techniques. The current system and the plans for its future are examined.

Walls, Bryan↗

Traffic Signal Control With Adaptive Online-Learning Scheme Using Multiple-Model Neural Networks

This article proposes a new traffic signal control algorithm to deal with unknown-traffic-system uncertainties and reduce delays in vehicle travel time. Unknown-traffic-system dynamics are approximated using a recurrent neural network (NN). To accurately identify the traffic system model, an online-learning scheme is developed to switch among a set of candidate NNs (i.e., multiple-model NNs) based on their estimation errors. Then, a bank of optimal signal-timing controllers is designed based on the online identification of the traffic system. Simulation studies have been carried out for the obtained control strategies using multiple-model NNs, and the desired results have been obtained. Moreover, compared with the widely used actuated traffic signal control schemes, it is shown that the proposed method can reduce vehicle travel delays and improve traffic system robustness.

99 GENERAL AND MISCELLANEOUS↗

An Edge-Cloud Integrated Solution for Buildings Demand Response Using Reinforcement Learning

Buildings, as major energy consumers, can provide great untapped demand response (DR) resources for grid services. However, their participation remains low in real-life. One major impediment for popularizing DR in buildings is the lack of cost-effective automation systems that can be widely adopted. Existing optimization-based smart building control algorithms suffer from high costs on both building-specific modeling and on-demand computing resources. To tackle these issues, this paper proposes a cost-effective edge-cloud integrated solution using reinforcement learning (RL). Beside RL’s ability to solve sequential optimal decision-making problems, its adaptability to easy-to-obtain building models and the off-line learning feature are likely to reduce the controller’s implementation cost. Using a surrogate building model learned automatically from building operation data, an RL agent learns an optimal control policy on cloud infrastructure, and the policy is then distributed to edge devices for execution. Simulation results demonstrate the control efficacy and the learning efficiency in buildings of different sizes. A preliminary cost analysis on a 4-zone commercial building shows the annual cost for optimal policy training is only 2.25% of the DR incentive received. Results of this study show a possible approach with higher return on investment for buildings to participate in DR programs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microreactor Automated Control System Test Bed Digital Architecture for Real-Time, Hardware-in-the-Loop Simulation

This work describes progress made towards the development of a real-time hardware-in-the-loop (HIL) test bed for non-nuclear testing of microreactor control schemes and failure modes. Non-nuclear testing is a crucial step in developing robust control algorithms for managing microreactor dynamics. The creation of an HIL simulation harnesses the realistic dynamics of physical analogue systems while additionally considering the challenges of variable communication delay. This collaborative effort between Oak Ridge National Laboratory and Idaho National Laboratory has resulted in a LabVIEW-based gRPC communication protocol which couples a TRANSFORM Modelica simulation of nuclear components to the ViBRANT physical hardware for realistic feedback and visual representation of control action in real time. A modular python client structure is developed to manage FMU-based Modelica simulation and real-time gRPC communication. HIL testing suggests that the modeled reactor with natural convection molten salt loop coolant configuration responds well to PID control of drum positioning for modulation of reactor core power, however, future efforts will be made to explore the added thermal inertial delay of system level control and downstream demand changes. Development of this platform with a generalized methodology provides a foundation for exploring a variety of reactor configurations and failure modes in rapid order to provide insight into the most effective avenues of study for further research and development.

McConnell, Jono [ORNL] (ORCID:0000000238984741)↗

Algorithms for the Automated Power Systems Management

The system breadboard for the demonstration of Automated Power Systems Management (APSM) functions has been designed, fabricated, and is in the final stages of verification and testing. APSM functions fall into categories of fault detection and correction, commanding system and subsystem test and diagnoses, relay position monitoring, data acquisition and processing, and power management. All these functions are accomplished through software residing in 8-bit microprocessors dedicated to each group of Viking Orbiter power breadboard subassemblies and a 16-bit microprocessor serving as the central processor for the power system. This paper describes key monitoring, diagnostic, and control algorithms used in the APSM breadboard.

Moser, R. L.↗