Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Transfer of EP and Doping Technology for PIP-II HB650 Cavities from Fermilab to Industry

Fermilab has optimized the surface processing conditions for PIP-II high beta 650 MHz cavities. This encompasses conditions for bulk electropolishing, heat treatment, nitrogen doping, post-doping final electropolishing, and post-processing surface rinsing. The technology has been effectively transitioned to industry. This paper highlights the efforts made to fine-tune the process and to smoothly share them with the partner labs and an associated vendor.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ferrite-Free Circulator for Precise Measurements of SRF Cavities with High Q-Factor

In this work, we suggest and investigate new magnetless circulators based on three resonators connected in a loop and parametrically modulated in time with mutual phase lag. The first design consists of three Fano resonators with a spectrally asymmetric response, in contrast to schemes based on the Lorentz resonators explored thus far. The second design includes three Fano-Lorentz resonators, i.e., it also possesses spatial asymmetry. We demonstrate that the asymmetric approach provides strong and reversible isolation for the practically feasible modulation amplitude and rate. The results of our work are promising for precise measurements of superconducting radio frequency cavities with high Q-factor.

43 PARTICLE ACCELERATORS↗

Extended Range SRF Cavity Tuner for LCLS II HE Project

The off-frequency detune method is being considered to be applied in the LCLS-II-HE superconducting linac to produce multi-energy electron beams for supporting multiple undulator lines simultaneously. To deliver off-frequency operation (OFO) requirements for SRF cavity tuner must be changed. Tuner design modifications and results of the testing eight cavity/tuner system, deployed in verification cryomodule (vCM), will be presented.

43 PARTICLE ACCELERATORS↗

LCLS-II-HE Cavity Qualification Testing

Acceptance testing of the LCLS-II-HE production cavities is approximately 65% complete. In this report, we present details of the test results, including summaries of the quench fields, intrinsic quality factors, and experience with field emission. We also offer an outlook on the remaining tests to be performed.

43 PARTICLE ACCELERATORS↗

Exploring innovative pathway for SRF cavity fabrication

This article shows a study on an alternative pathway for the fabrication of a complete 1.3 GHz SRF cavity, aiming at improving production reliability, reducing the use of chemical polishing (EP or BCP) which is a costly and safety-critical step, and preserving surface quality after forming. Unlike the conventional pathway, the fabrication process is performed after polishing. This point is crucial as the used polishing technology could be applied only to flat geometries. The performed investigation demonstrates that damages during the fabrication process are considered minor, localized, and limited to the near-surface. Moreover, these studies confirm that the damaged layer (100-200 µm) is mainly caused by the rolling process, and not by the subsequent fabrication steps. A laser confocal microscope and SEM-EBSD technique were used to compare samples before and after forming. The preliminary results are discussed and presented in this paper.

Hryhorenko, O.↗

Conduction-Cooled Operation of an SRF Multi-Cell Cavity

The development of compact, SRF-based accelerators for applications beyond research is experiencing notable advancements due to the use of cryocoolers for conduction-cooling instead of traditional liquid cryogens. Following the successful demonstration of a single-cell cavity operated through conduction cooling with three two-stage cryocoolers, Jefferson Lab (JLab) has made strides in the operation of a multi-cell resonator. This milestone paves the way for high-energy applications of compact, conduction-cooled SRF machines. The demonstration, carried out in collaboration with General Atomics, will take place in a dedicated horizontal test cryostat (HTC) at their San Diego facility. This presentation will highlight the technological developments, the latest results, and valuable lessons learned.

Vennekate, J. [Thomas Jefferson National Accelerat↗

An Experimental Study of Design and Performance for the Water-Based Reactor Cavity Cooling System

The document summarizes the test activity conducted at the Texas A&M University water-cooled Reactor Cavity Cooling System experimental facility. Flow and temperature characterization of the risers' panel is conducted using advanced measurement techniques. Steady-state and transient scenarios are studied, analyzed, and discussed in the report. The experimental work is complemented with modeling and simulations using system level codes.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Developing Conduction-Cooled SRF Cavities and First Test Results [Slides]

Summary and Future Work: Development of conduction cooling for SRF; practical thermal link design; experimental setup ready; first results are promising; 6.6 MV/m cwrecorded on a single cell 650 MHz Nb3Sn cavity Activities: ongoing and planned; improve magnetic hygiene of our cryostat; test with improved Nb3Sn coating; and identity and mitigate potential microphonics due to cryocooler vibrations.

43 PARTICLE ACCELERATORS↗

Cryocooler conduction-cooled SRF cavities for compact particle accelerators

Cryocooler conduction cooling offers simple, reliable cryogenics for developing industrial SRF e-beam accelerators. Conduction-cooled SRF R&D at Fermilab: first demonstration >6.5 MV/m cw on a 650 MHz Nb 3 Sn coated cavity; prototype development and high power accelerators designs in progress. Cryocooler conduction cooling can greatly expand access to SRF: university groups, industries can embark on in house SRF R&D without needing full stack helium cryogenic systems

43 PARTICLE ACCELERATORS↗

Development of a Novel Electrical Characterization Technique for Measuring Hidden Joint Contacts in Weapons Cavities (LDRD Final Report 218470)

This report summarizes research performed in the context of a REHEDS LDRD project that explores methods for measuring electrical properties of vessel joints. These properties, which include contact points and associated contact resistance, are “hidden” in the sense that they are not apparent from a computer-assisted design (CAD) description or visual inspection. As is demonstrated herein, the impact of this project is the development of electromagnetic near-field scanning capabilities that allow weapon cavity joints to be characterized with high spatial and/or temporal resolution. Such scans provide insight on the hidden electrical properties of the joint, allowing more detailed and accurate models of joints to be developed, and ultimately providing higher fidelity shielding effectiveness (SE) predictions. The capability to perform high-resolution temporal scanning of joints under vibration is also explored, using a multitone probing concept, allowing time-varying properties of joints to be characterized and the associated modulation to SE to be quantified.

42 ENGINEERING↗

Preliminary Design of Reactor Cavity Cooling System for a Horizontal Compact HTGR

The Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed MIGHTR in 3 years and support its commercialization as a safe and low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. This report documents the preliminary design study of the RCCS for the HC-HTGR. It includes the establishment of the design requirements, a high-level design study by initial scoping calculations, and preliminary performance calculations of the HC-HTGR RCCS design. Design requirements for the HC-HTGR RCCS have been established to guide preliminary design activities and scoping performance calculations. Initial scoping calculations including estimation of the water inventory, estimation of HVAC thermal capability, and a parametric study on loop dimensions by standalone RCCS analysis. Based on scoping calculation results, a set of baseline dimensions of the HC-HTGR RCCS was derived. A water panel modeling approach was investigated to explore various potential design options for the water panel under consideration for the HC-HTGR RCCS using RELAP5-3D. A test case study was performed to assess the prediction capability of two modeling approaches. The results were compared with CFD simulations conducted in constant RPV temperature and heat flux boundary conditions. It confirms the capability of the RELAP5-3D modeling approach to include all important heat transfer mechanisms expected in the HC-HTGR RCCS operation conditions. Then, a reference RELAP5-3D model for the 1/8 th of a compartment of the preliminary design of the HC-HTGR RCCS was developed. A preliminary performance analysis was conducted to evaluate single-phase natural circulation performance with different top tank temperature values and panel conduction performance in various operation conditions. From single-phase natural circulation performance analysis, the system operation mode was investigated in normal operating and limiting design conditions. It showed operation mode in a subcooled state with a proper top tank water cooling system. Parasitic heat loss by both internal air flow and RCCS was estimated, showing it satisfies maintaining below target maximum heat loss of the HC-HTGR RCCS. From the panel conduction performance analysis, two candidate materials for the riser tube such as carbon steel and stainless steel were compared in the thermal performance of HC-HTGR RCCS. From a single water panel test compared with CFD simulation results, it was confirmed that the current capability of the RELAP5-3D modeling approach for the water panel predicts the thermal conduction of two different materials of the water panel. Then, system-level thermal performance analysis was performed for 1/8 th of the compartment of the preliminary HC-HTGR RCCS design. It was first observed that the current preliminary HC-HTGR RCCS design had minimal impact on the overall thermal performance of the water panel by changing pipe material from carbon steel to stainless steel. From Argonne’s effort on the ongoing water-based NSTF testing program, several considerations other than the thermal performance point of view were addressed to be considered in selecting pipe materials.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-efficiency microwave-optical quantum transduction based on a long-coherence-time cavity electro-optic system

We propose a 3D quantum transduction architecture based on a long-coherence-time superconducting cavity coupled to an electro-optic resonator. The 3D hybrid system enables high-efficiency conversion between microwave and optical quantum signals, with potential applications in optical readout of qubits, high-fidelity entanglement generation and high-precision sensing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗