Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “bus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

A model-based approach to the symbolic control of space subsystems

A multilayered approach to the symbolic control of complex electromechanical assemblies, such as spaceborne thermal, power, and life subsystems, is discussed. An example of this approach is given in some recent tests of the Thermal Expert System (TEXSYS) in control of the Boeing Aerospace Thermal Bus System (BATBS), a prototype two-phase Space Station Freedom thermal bus. The BATBS hardware requires read-update-act cycles of under a minute, and it is subject to dynamic reconfiguration while operating. These performance requirements are addressed by layering model-based expert system software on a conventional numerical data acquisition and control system. TEXSYS test results demonstrate both nominal control and fault recovery actions with the BATBS. Dynamic modification of the symbolic model used in this approach is compared to that of a classical numerical adaptive controller.

Glass, B. J.↗

Low-temperature thermal control for a lunar base

The generic problem of rejecting low- to moderate-temperature heat from space facilities located in a hot thermal sink environment is studied, and the example of a lunar base located near the equator is described. The effective thermal sink temperature is often above or near nominal room temperature. A three heat pump assisted thermal bus concept appears to be the most viable as they are the least sensitive to environmental conditions. Weight estimates are also developed for each of the five thermal control concepts studied: (1) 149kg/kW for a central thermal loop with unitary heat pumps; (2) 133 kg/kW for a conventional bus connected to large, central heat pumps at the radiator; (3) 134 kg/kW for a central, dual loop heat pump concept; (4) 95 kg/kW for the selective field-of-view radiator; and (5) 126 kg/kW for the regolith concept.

Swanson, Theodore D.↗

Final Report

The discussion of simulators and simulation, data aquisition and transmission and evaluation of Ada compilers and programming environments is presented. The following subject areas are covered: Bus 1553B software development; simulator development; and Ada programs to interface with C-software which drives PC-based interface cards for 1553B bus.

Deacetis, Louis A.↗

Transportable telemetry workstation

The goal was to complete the design of a prototype for a Transportable Telemetry Workstation (TTW). The Macintosh 2 is used to provide a low-cost system which can house real-time cards mounted on the NuBus inside the Macintosh 2 plus provide a standardized user interface on the Macintosh 2 console. Prior to a telemetry run, the user will be able to configure his real-time telemetry processing functions from the Macintosh 2 console. During a telemetry run, the real-time cards will store the telemetry data directly on a hard disk while permitting viewing of the data cards on the Macintosh 2 console on various selectable formats. The user will view the cards in terms of the functions they perform and the selectable paths through the cards, it is not required to become involved directly in hardware issue except in terms of the functional configuration of the system components. The TTW will accept telemetry data from an RS422 serial input data bus, pass it through a frame synchronizer card and on to a real time controller card via a telemetry backplane bus. The controller card will then route the data to a hard disk through a SCSI interface, and/or to a user interface on the Macintosh 2 console by way of the Macintosh 2 NuBus. The three major components to be designed, therefore, are the TTW Controller Card, the TTW Synchronizer Card, and the NuBus/Macintosh 2 User Interface. Design and prototyping of this state-of-the-art, transportable, low-cost, easy-to-use multiprocessor telemetry system is continuing. Other functions are planned for the future.

Collins, Aaron S.↗

The transient performance of a two-phase fluid reservoir

Thermal control of future large, high power spacecraft will require a two-phase fluid central bus. The two-phase fluid reservoir is a critical component in the two-phase fluid bus. It both controls the saturation temperature and provides a space for volumetric changes. A dynamic reservoir simulation model does not currently exist, but it is needed to expedite efforts and reduce risk. During 1989 an effort was made to develop a simulation model of the transient performance of a two-phase fluid reservoir. As a beginning, a preliminary model was developed. It is based upon component mathematical models in lumped parametric form and build upon five component mathematical models for calculating dynamic responses of two-phase fluid reservoirs, primary feedback elements, controller commands, heater actuators, and reservoir heaters. As much as possible, the model took advantage of the available SINDA'85/FLUINT thermal/fluid integrator. Additional calculation logic and computer subroutines were developed to complete implementation of the model. The model is capable of simulating dynamic response of an equilibrium two-phase fluid reservoir. Modification of the model to include the liquid/vapor nonequilibrium is required for applications of the model to simulate performance of reservoir in which the liquid and vapor phases of the reservoir fluid are not in equilibrium. In addition, the model in its present form, needs to be refined in several respects. More empirical data are needed to guide the model development. The model may then be used to conduct a full parametric study of two-phase fluid reservoirs. More complexities in two-phaes flow regions in laboratory and flight conditions may have to be considered eventually if empirical data cannot be simulated satisfactorily. System with other components arrangement also need to be simulated if optimization is ever to be attained. The present model does, however, preliminarily demonstrates that such analyses are quite possible and offers a far less expensive method to understand the transient of a two-phase fluid reservoir system than a totally headware approach.

Chi, Joseph↗

A universal computer control system for motors

A control system for a multi-motor system such as a space telerobot, having a remote computational node and a local computational node interconnected with one another by a high speed data link is described. A Universal Computer Control System (UCCS) for the telerobot is located at each node. Each node is provided with a multibus computer system which is characterized by a plurality of processors with all processors being connected to a common bus, and including at least one command processor. The command processor communicates over the bus with a plurality of joint controller cards. A plurality of direct current torque motors, of the type used in telerobot joints and telerobot hand-held controllers, are connected to the controller cards and responds to digital control signals from the command processor. Essential motor operating parameters are sensed by analog sensing circuits and the sensed analog signals are converted to digital signals for storage at the controller cards where such signals can be read during an address read/write cycle of the command processing processor.

Szakaly, Zoltan F.↗

Performance results of Grumman prototype Space Station Space Erectable Radiator System ground test articles

The paper addresses individual-radiator performance results of the prototype Space Erectable Radiator System (SERS) in both ambient and thermal vacuum environments. The radiator design utilizing a two-phase fluid loop is outlined, along with SERS design requirements, radiator panel hardware, and whiffletree clamp hardware providing a dry-contact interface of the SERS panel with the heat exchanger of the thermal bus. It is observed that throughout integrated thermal-bus tests, SERS panels managed the load demands whether interfacing with twin condensers, in parallel-flow configuration, or with shear-flow condensers, in a cross-flow configuration. It is found that the insulation losses in the integrated and stand-alone test points are approximately 2 to 6 pct. The motorized whiffletree clamp is seen as performing satisfactorily during remote operations as well as maintaining 28,800-lb force throughout the test duration without requiring further adjustments.

Gisondo, Francine↗

Control of multiple resonant power processors in a multi-source system

Analysis and test results show that phasor-regulated, Mapham-derived resonant inverters can be paralleled to provide standardizing interfaces for multiple sources on a utility-type, aerospace power distribution bus. The basic sources do not require matching in any way, and may have grossly different characteristics. Fully stable system architectures with multiple sources, parallel/redundant distribution buses, and a wide variety of loads can be easily constructed and controlled. The commands and parameters available for system control allow for tight tolerance bus voltage control, and absolute power-sharing control from the various sources over the full range of possible source and load variations. That level of control enables simplified load power processing hardware and the distribution of losses to optimally load the source thermal control system. Positive control of all system performance and allocation of losses are not required by all missions or vehicles, and overall vehicle considerations do not always require the loads on vehicle energy sources and thermal control systems to be balanced. In those cases, power system control can be simplified, and a hierarchical set of defaults can be substituted for computer-generated or supervisory input commands to allow for stable, fully autonomous system operation.

Mildice, James↗

Galileo spacecraft power management and distribution system

The Galileo PMAD (power management and distribution system) is described, and the design drivers that established the final as-built hardware are discussed. The spacecraft is powered by two general-purpose heat-source-radioisotope thermoelectric generators. Power bus regulation is provided by a shunt regulator. Galileo PMAD distributes a 570-W beginning of mission (BOM) power source to a user complement of some 137 load elements. Extensive use of pyrotechnics requires two pyro switching subassemblies. They initiate 148 squibs which operate the 47 pyro devices on the spacecraft. Detection and correction of faults in the Galileo PMAD is an autonomous feature dictated by requirements for long life and reliability in the absence of ground-based support. Volatile computer memories in the spacecraft command and data system and attitude control system require a continuous source of backup power during all anticipated power bus fault scenarios. Power for the Jupiter Probe is conditioned, isolated, and controlled by a Probe interface subassembly. Flight performance of the spacecraft and the PMAD has been successful to date, with no major anomalies.

Detwiler, R. C.↗

Modeling and simulation of the space platform power system

A comprehensive computer-aided modeling and simulation technique for the space platform power system is described. Large-signal and small-signal modeling is presented for the system components. The component models have been integrated to form the complete power system model. The system model is shown to be a powerful tool in simulating the behavior of the system with variation of illumination level and load. It can be used to study the bus regulation in each mode and to observe mode changes as the solar array is subjected to transitions from sunlight to eclipse and back to sunlight. System simulations show how the bus regulation is maintained by activating the shunt switching unit, the charger, or the discharger, depending on the available illumination level. The system model is suitable for verifying hardware results of for analyzing the performance of a proposed system where hardware testing is not feasible. The EASY5 dynamic analysis program is used as the host software for the modeling and simulation.

Patil, A. R.↗

TEXSYS - A large scale demonstration of model-based real-time control of a Space Station subsystem

A hybrid approach to qualitative and temporal reasoning, using a device-oriented model-based representation in conjunction with both consistency-based and classification diagnosis methods, can be effectively used to monitor and control a complex electromechanical system. An example of this approach is given in some recent tests of the Thermal Expert System (TEXSYS) in control of the Boeing Aerospace Thermal Bus System (BATBS), a prototype two-phase Space Station Freedom thermal bus. The constraints of realtime performance and changing target hardware led to significant changes in the initial approach, including a reduction in the use of deep structural reasoning and the addition of temporal reasoning capabilities. TEXSYS test results show the successful completion of both nominal control and fault recovery actions with the BATBS.

Glass, B. J.↗

Initializing Embedded Data Processors From A Single Source

Initial-computer-program-loading system provides startup information to all embedded data processors (EDP's) in general-purpose computer system. Remote processors given image of startup diskette so real local diskette and drive unneeded. System less complex and equipment costs less. Additional benefit, initial program loading tests bus. If boot-up program transmitted correctly, bus assumed to be operating properly.

Chavez, Edward A.↗

Fault-tolerance techniques for high-speed fiber-optic networks

Four fiber optic network topologies (linear bus, ring, central star, and distributed star) are discussed relative to their application to high data throughput, fault tolerant networks. The topologies are also examined in terms of redundancy and the need to provide for single point, failure free (or better) system operation. Linear bus topology, although traditionally the method of choice for wire systems, presents implementation problems when larger fiber optic systems are considered. Ring topology works well for high speed systems when coupled with a token passing protocol, but it requires a significant increase in protocol complexity to manage system reconfiguration due to ring and node failures. Star topologies offer a natural fault tolerance, without added protocol complexity, while still providing high data throughput capability.

Deruiter, John↗

Expanded serial communication capability for the transport systems research vehicle laptop computers

A recent upgrade of the Transport Systems Research Vehicle (TSRV) operated by the Advanced Transport Operating Systems Program Office at the NASA Langley Research Center included installation of a number of Grid 1500 series laptop computers. Each unit is a 80386-based IBM PC clone. RS-232 data busses are needed for TSRV flight research programs, and it has been advantageous to extend the application of the Grids in this area. Use was made of the expansion features of the Grid internal bus to add a user programmable serial communication channel. Software to allow use of the Grid bus expansion has been written and placed in a Turbo C library for incorporation into applications programs in a transparent manner via function calls. Port setup; interrupt-driven, two-way data transfer; and software flow control are built into the library functions.

Easley, Wesley C.↗

Microprocessor control of multiple peak power tracking DC/DC converters for use with solar cell arrays

A method and an apparatus is provided for efficiently controlling the power output of a solar cell array string or a plurality of solar cell array strings to achieve a maximum amount of output power from the strings under varying conditions of use. Maximum power output from a solar array string is achieved through control of a pulse width modulated DC/DC buck converter which transfers power from a solar array to a load or battery bus. The input voltage from the solar array to the converter is controlled by a pulse width modulation duty cycle, which in turn is controlled by a differential signal controller. By periodically adjusting the control voltage up or down by a small amount and comparing the power on the load or bus with that generated at different voltage values a maximum power output voltage may be obtained. The system is totally modular and additional solar array strings may be added to the system simply by adding converter boards to the system and changing some constants in the controller's control routines.

Frederick, Martin E.↗

COLD-SAT orbital experiment configured for Altas launch

A study was done of the feasibility of conducting liquid hydrogen orbital storage, acquisition, and transfer experiments aboard a spacecraft launched by a commercial Atlas launch vehicle. Three hydrogen tanks are mated to a spacecraft bus that is similar to that used for three-axis-controlled satellites. The bus provides power, communications, and attitude control along with acceleration levels ranging from 10 exp -6 to 10 exp -4 g. At launch, all the liquid hydrogen is contained in the largest tank, which has an insulation system designed for both space operation and the short-term launch pad and ascent environment. This tank is much lighter and lower in cost than a vacuum-jacketed design, and is made possible by the experiment tanking options available due to the hydrogen-fueled Centaur upper stage of the Atlas I.

Schuster, J. R.↗

The ACTS Spacecraft

The tested physical and performance characteristics of the ACTS spacecraft are presented with emphasis placed on those for the multibeam antenna, the communications electronics panel, and the bus. Performance measurements for the multibeam antenna agree with predicted parameters, and the electronics panel provides four transponder channels for redundancy and system reliability. The spacecraft bus provides unique features including an attitude-control subsystem with autotrack for pitch accuracy, a sun sensor for yaw control, and thruster firing for dual spin turns.

Gargione, Frank↗

A fault-tolerant network architecture for integrated avionics

The Army Fault-Tolerant Architecture (AFTA) under construction at the Charles Stark Draper Laboratory is an example of a highly integrated critical avionics system. The AFTA system must connect to other redundant and nonredundant systems, as well as to input/output devices. A fault-tolerant data bus (FTDB) is being developed to provide highly reliable communication between the AFTA computer and other network stations. The FTDB is being designed for Byzantine resilience and is probably capable of tolerating any single arbitrary fault. The author describes a prototype architecture for the fault-tolerant data bus.

Butler, Bryan↗