The bright frontiers of microbial metabolic optogenetics

In recent years, light-responsive systems from the field of optogenetics have been applied to several areas of metabolic engineering with remarkable success. By taking advantage of light's high tunability, reversibility, and orthogonality to host endogenous processes, optogenetic systems have enabled unprecedented dynamical controls of microbial fermentations for chemical production, metabolic flux analysis, and population compositions in co-cultures. In this article, we share our opinions on the current state of this new field of metabolic optogenetics. Furthermore, we make the case that it will continue to impact metabolic engineering in increasingly new directions, with the potential to challenge existing paradigms for metabolic pathway and strain optimization as well as bioreactor operation.

59 BASIC BIOLOGICAL SCIENCES↗

Screening and modular design for metabolic pathway optimization

Biological conversion of substrate sugars to a variety of products is an increasingly popular option for chemical transformation due to its high specificity and because of significant interest in the use of renewable feedstocks. Yet, pathway optimization through metabolic engineering is often needed to make such molecules economically at a relevant scale. Employing effective methods to search and narrow the immense pathway parameter space is essential to meet performance metrics such as high titer, yield and productivity with efficiency. This review focuses on two practices that increase the likelihood of finding a more advantageous pathway solution: implementing a screen to identify high producers and utilizing modular pathway design to streamline engineering efforts. While screens seek to couple product titer with a high-throughput measurement output, modular design aims to rationally construct pathways to allow parallel optimization of various units. Both of these methodologies have proven widely successful in metabolic engineering, with combinations of them resulting in synergistic enhancements to pathway optimization. This review will specifically illustrate their utility for microbially derived acid and alcohol products, which are of interest as fuels and value added products.

59 BASIC BIOLOGICAL SCIENCES↗

Conditional guide RNA deactivation by mRNA and small molecule triggers in Saccharomyces cerevisiae

CRISPR interference (CRISPRi) technologies have revolutionized bioengineering by providing precise tools for gene expression modulation, enabling targeted gene perturbation and metabolic pathway optimization. Despite these advances, achieving dynamic control over gene expression by CRISPR-based regulation remains a challenge due to its inherently static nature. Utilizing toehold-mediated strand displacement and ligand-responsive ribozymes (aptazymes), this study introduces switchable guide RNAs (gRNAs) that facilitate tunable gene expression mediated by mRNA or small molecule signals. We demonstrate complete silencing of gRNA via strategically designed 5’ or 3’ extensions that impede the gRNA spacer or the dCas9 handle, with subsequent restoration of function through sequestration or cleavage of the obstructive sequence. The resulting toehold-embedded or aptazyme-embedded gRNAs can be deactivated by specific signals, including two full-length translatable mRNAs and two small molecule triggers, thereby lifting CRISPRi repression on targeted genes. This modular approach allows for gRNA-based biocomputing through multi-layer or multi-input genetic logic gates in Saccharomyces cerevisiae . Offering a versatile strategy for post-CRISPR regulation in response to environmental signals or cellular states, this methodology expands the toolkit in eukaryotic systems for reversible control of gene expression.

Aptazyme↗

A resettable in-line particle concentrator using AC electrokinetics for distributed monitoring of microalgae in source waters

Green algae have been studied as an important and effective biomarker to indicate water quality due to their sensitivity to toxic agents in freshwater sources. But, conventional methods to monitor algal physiology use a chlorophyll fluorometer whose use is hampered by high-cost, large footprint, and limited sensitivity for practical samples containing low algal concentration. In order to overcome these constraints, we developed a multi-level electrode platform for resettable trapping of algae via AC electro-osmosis (ACEO) and negative dielectrophoresis. Preliminary experiments were performed in freshwater with conductivity of 0.02 S/m. Algal trapping was demonstrated at a low voltage of 2 V. The concentration effect was experimentally verified by measuring the fluorescence intensity of algae and using hemocytometer counting chambers at the inlet and outlet of the multilevel microchannel lab-on-a-chip. An optimal frequency was found for trapping, which agrees with the frequency dependence of ACEO flow velocity. Through-flow rate and electrode dimensions were optimized as well. Trapping efficiencies within the range of 26% - 65% have been obtained. A maximum trapping rate of 182 cells/s was obtained with a flow rate of 20 l/min. Our lab-on-a-chip shows high potential for improving the limit of detection in algal monitoring and enabling the development of a portable, integrated and automated system for monitoring the quality of source drinking waters.

30 DIRECT ENERGY CONVERSION↗

Machine learning enabled acoustic detection of sub-nanomolar concentration of trypsin and plasmin in solution

Here, we demonstrate a machine learning enabled low-cost acoustic detection of protease which may find application in assuring quality and safety of dairy products, drug screening, molecular profiling, and disease diagnostics. A hydrophilic SiO 2 -coated quartz crystal microbalance (QCM) acts as a substrate to assemble α-, β-, and κ-casein layers (protease reporters) and as a transducer for measuring changes in frequency as casein is removed by protease. We demonstrate that α-, β-, and κ-caseins can form stable assembly on SiO 2 from phosphate-buffered solution (PBS) solution. Exposure to protease results in cleaving of casein which changes the frequency of the 1st–11th odd harmonics of QCM. Monitoring β-casein cleavage allows ~0.2 nM detection of trypsin and ~0.5 nM detection of plasmin and enables differentiation between trypsin and plasmin after <2 min of protease exposure. The casein-coated QCM allows sub-nanomolar detection and classification of protease.

47 OTHER INSTRUMENTATION↗

Scripting a new dialogue between diazotrophs and crops

Diazotrophs are bacteria and archaea that can reduce atmospheric dinitrogen (N 2 ) into ammonium. Plant–diazotroph interactions have been explored for over a century as a nitrogen (N) source for crops to improve agricultural productivity and sustainability. This scientific quest has generated much information about the molecular mechanisms underlying the function, assembly, and regulation of nitrogenase, ammonium assimilation, and plant–diazotroph interactions. This review presents various approaches to manipulating N fixation activity, ammonium release by diazotrophs, and plant–diazotroph interactions. Here, we discuss the research avenues explored in this area, propose potential future routes, emphasizing engineering at the metabolic level via biorthogonal signaling, and conclude by highlighting the importance of biocontrol measures and public acceptance.

59 BASIC BIOLOGICAL SCIENCES↗

Advances in Assays and Analytical Approaches for Botulinum Toxin Detection

Methods to detect botulinum toxin, the most poisonous substance known, are reviewed. Current assays are being developed with two main objectives in mind: 1) to obtain sufficiently low detection limits to replace the mouse bioassay with an in vitro assay, and 2) to develop rapid assays for screening purposes that are as sensitive as possible while requiring an hour or less to process the sample an obtain the result. This review emphasizes the diverse analytical approaches and devices that have been developed over the last decade, while also briefly reviewing representative older immunoassays to provide background and context.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic Electrochemical Sensing Platform for Biomonitoring of Exposure to Organophosphorus Pesticides and Nerve Agents Based on Simultaneous Measurement of Total Enzyme Amount and Enzyme Activity

We report a new approach for electrochemical quantification of enzymatic inhibition and phosphorylation for biomonitoring of exposure to organophosphorus (OP) pesticides and nerve agents based on a magnetic beads (MBs) immunosensing platform. The principle of this approach is based on the combination of MBs immuno-capture based enzyme activity assay and competitive immunoassay of total amount of enzyme for simultaneous detection of enzyme inhibition and phosphorylation in biological fluids. Butyrylcholinesterase (BChE) was chosen as a model enzyme. In competitive immunoassay, the target total BChE in a sample (mixture of OP-inhibited BChE and active BChE) competes with the BChE modified on the MBs to bind to the limited anti-BChE antibody labeled with quantum dots (QDs-anti-BChE), and followed by electrochemical stripping analysis of the bound QDs conjugate on the MBs. This assay shows a linear response over the total BChE concentration range of 0.1~20 nM. Simultaneously, real time BChE activity was measured on an electrochemical carbon nanotube-based sensor coupled with microflow injection system after immuno-capture by MBs-anti-BChE conjugate. Therefore, the formed phosphorylated adduct (OP-BChE) can be estimated by the difference values of the total amount BChE (including active and OP-inhibited) and active BChE from established calibration curves. This approach not only eliminates the difficulty in screening of low-dose OP exposure (less than 20% inhibition of BChE) because of individual variation of BChE values, but also avoids the drawback of the scarce availability of OP-BChE antibody. It is sensitive enough to detect 0.5 nM OP-BChE, which is less than 2% BChE inhibition. This method offers a new method for rapid, accurate, selective and inexpensive quantification of phosphorylated adducts and enzyme inhibition for biomonitoring of OP and nerve agent exposures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Remote Floating-Gate Field-Effect Transistor with 2-Dimensional Reduced Graphene Oxide Sensing Layer for Reliable Detection of SARS-CoV-2 Spike Proteins

Despite intensive research of nanomaterials-based field-effect transistors (FETs) as a rapid diagnostic tool, it remains to be seen for FET sensors to be used for clinical applications due to a lack of stability, reliability, reproducibility, and scalability for mass production. In this work, we propose a remote floating-gate (RFG) FET configuration to eliminate device-to-device variations of two-dimensional reduced graphene oxide (rGO) sensing surfaces and most of the instability at the solution interface. Also, critical mechanistic factors behind the electrochemical instability of rGO such as severe drift and hysteresis were identified through extensive studies on rGO–solution interfaces varied by rGO thickness, coverage, and reduction temperature. rGO surfaces in our RFGFET structure displayed a Nernstian response of 54 mV/pH (from pH 2 to 11) with a 90% yield (9 samples out of total 10), coefficient of variation (CV) < 3%, and a low drift rate of 2%, all of which were calculated from the absolute measurement values. As proof-of-concept, we demonstrated highly reliable, reproducible, and label-free detection of spike proteins of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in a saliva-relevant media with concentrations ranging from 500 fg/mL to 5 μg/mL, with an R 2 value of 0.984 and CV < 3%, and a guaranteed limit of detection at a few pg/mL. Taken together, this new platform may have an immense effect on positioning FET bioelectronics in a clinical setting for detecting SARS-CoV-2.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of silica matrix composition and functional component additives on the bioactivity and viability of encapsulated living cells

The remarkable impact encapsulation matrix chemistry can have on the bioactivity and viability of integrated living cells is reported. Two silica chemistries (aqueous silicate and alkoxysilane), and a functional component additive (glycerol), are employed to generate three distinct silica matrices. These matrices are used to encapsulate living E. coli cells engineered with a synthetic riboswitch for cell-based biosensing. Following encapsulation, membrane integrity, reproductive capability, and riboswitch-based protein expression levels and rates are measured over a 5 week period. Striking differences in E. coli bioactivity, viability, and biosensing performance are observed for cells encapsulated within the different matrices. E. coli cells encapsulated for 35 days in aqueous silicate-based (AqS) matrices showed relatively low membrane integrity, but high reproductive capability in comparison to cells encapsulated in glycerol containing sodium silicate-based (AqS + g) and alkoxysilane-based (PGS) gels. Further, cells in sodium silicate-based matrices showed increasing fluorescence output over time, resulting in a 1.8-fold higher fluorescence level, and a faster expression rate, over cells free in solution. Furthermore, this unusual and unique combination of biological properties demonstrates that careful design of the encapsulation matrix chemistry can improve functionality of the biocomposite material, and result in new and unexpected physiological states.

59 BASIC BIOLOGICAL SCIENCES↗

A Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca 2+ and pH

Homeostasis of ionized calcium in biofluids is critical for human biological functions and organ systems. Measurement of ionized calcium for clinical applications is not easily accessible due to its strict procedures and dependence on pH. pH balance in body fluids greatly affects metabolic reactions and biological transport systems. Here, we demonstrate a wearable electrochemical device for continuous monitoring of ionized calcium and pH of body fluids using a disposable and flexible array of Ca 2+ and pH sensors that interfaces with a flexible printed circuit board. This platform enables real-time quantitative analysis of these sensing elements in body fluids such as sweat, urine, and tears. Accuracy of Ca 2+ concentration and pH measured by the wearable sensors is validated through inductively coupled plasma-mass spectrometry technique and a commercial pH meter, respectively. Our results show that the wearable sensors have high repeatability and selectivity to the target ions. Real-time on-body assessment of sweat is also performed, and our results indicate that calcium concentration increases with decreasing pH. Finally, this platform can be used in noninvasive continuous analysis of ionized calcium and pH in body fluids for disease diagnosis such as primary hyperparathyroidism and kidney stones.

47 OTHER INSTRUMENTATION↗

Wearable Microsensor Array for Multiplexed Heavy Metal Monitoring of Body Fluids

A flexible and wearable microsensor array is described for simultaneous multiplexed monitoring of heavy metals in human body fluids. Zn, Cd, Pb, Cu, and Hg ions are chosen as target analytes for detection via electrochemical square wave anodic stripping voltammetry (SWASV) on Au and Bi microelectrodes. The oxidation peaks of these metals are calibrated and compensated by incorporating a skin temperature sensor. High selectivity, repeatability, and flexibility of the sensor arrays are presented. Human sweat and urine samples are collected for heavy metal analysis, and measured results from the microsensors are validated through inductively coupled plasma mass spectrometry (ICP-MS). Real-time on-body evaluation of heavy metal (e.g., zinc and copper) levels in sweat of human subjects by cycling is performed to examine the change in concentrations with time. Finally, this platform is anticipated to provide insightful information about an individual's health state such as heavy metal exposure and aid the related clinical investigations.

47 OTHER INSTRUMENTATION↗

A Wearable Microfluidic Sensing Patch for Dynamic Sweat Secretion Analysis

Wearable sweat sensing is a rapidly rising research area driven by its promising potential in health, fitness, and diagnostic applications. Despite the growth in the field, major challenges in relation to sweat metrics remain to be addressed. These challenges include sweat rate monitoring for its complex relation with sweat compositions and sweat sampling for sweat dynamics studies. Here, we present a flexible microfluidic sweat sensing patch that enhances real-time electrochemical sensing and sweat rate analysis via sweat sampling. The device contains a spiral-patterned microfluidic component that is embedded with ion-selective sensors and an electrical impedance-based sweat rate sensor on a flexible plastic substrate. The patch is enabled to autonomously perform sweat analysis by interfacing the sensing component with a printed circuit board that is capable of on-site signal conditioning, analysis, and transmission. Progressive sweat flow in the microfluidic device, governed by the pressure induced by the secreted sweat, enhances sweat sampling and electrochemical detection via a defined sweat collection chamber and a directed sweat route. The characteristic of the sweat rate sensor is validated through a theoretical simulation, and the precision and accuracy of the flow rate is verified with a commercial syringe pump and a Macroduct sweat collector. On-body simultaneous monitoring of ion (H + , Na + , K + , Cl – ) concentration and sweat rate is also demonstrated for sensor functionality. This sweat sensing patch provides an integrated platform for a comprehensive sweat secretion analysis and facilitates physiological and clinical investigations by closely monitoring interrelated sweat parameters.

47 OTHER INSTRUMENTATION↗

A Fully Integrated and Self-Powered Smartwatch for Continuous Sweat Glucose Monitoring

Wearable devices for health monitoring and fitness management have foreseen a rapidly expanding market, especially those for noninvasive and continuous measurements with real-time display that provide practical convenience and eliminated safety/infection risks. In this research, a self-powered and fully integrated smartwatch that consists of flexible photovoltaic cells and rechargeable batteries in the forms of a “watch strap”, electrochemical glucose sensors, customized circuits, and display units integrated into a “dial” platform is successfully fabricated for real-time and continuous monitoring of sweat glucose levels. The functionality of the smartwatch, including sweat glucose sensing, signal processing, and display, can be supported with the harvested/converted solar energy without external charging devices. The Zn-MnO 2 batteries serve as intermediate energy storage units and the utilization of aqueous electrolytes eliminated safety concerns for batteries, which is critical for wearable devices. Such a wearable system in a smartwatch fashion realizes integration of energy modules with self-powered capability, electrochemical sensors for noninvasive glucose monitoring, and in situ and real-time signal processing/display in a single platform for the first time. The as-fabricated fully integrated and self-powered smartwatch also provides a promising protocol for statistical study and clinical investigation to reveal correlations between sweat compositions and human body dynamics.

47 OTHER INSTRUMENTATION↗

Smart Microbial Cells Couple Catalysis and Sensing to Provide High-Throughput Selection of an Organophosphate Hydrolase

Enzyme engineering for gain of function requires navigating a large combinatorial sequence space efficiently. Typically, many mutations are needed to get significant improvements, while a single “bad” mutation can inactivate the enzyme. To establish high-throughput screening and achieve enhanced resolution between two variants, genetic libraries of the organophosphate hydrolase enzyme paraoxonase 1 (PON 1 ) were rapidly screened via an engineered positive-feedback circuit: a p-nitrophenol (PNP)-specific transcription factor (TF) regulated expression of PON 1 , which catalyzed paraoxon breakdown and PNP production. Rare active mutant colonies, picked by simple visual fluorescence of a PON 1 –green fluorescent protein (GFP) fusion, were characterized. Furthermore, in a single screening round, high (library-scale) throughput enabled the discovery of enhanced paraoxon degradation activity in PON 1 , including structurally unexpected mutations.

59 BASIC BIOLOGICAL SCIENCES↗