Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Beam-dump ceiling and its experimental implications: The case of a portable experiment

We generalize the nature of the so-called beam-dump “ceiling” beyond which the improvement on the sensitivity reach in the search for fast-decaying mediators dramatically slows down, and we point out its experimental implications that motivate tabletop-sized beam-dump experiments for the search. Light (bosonic) mediators are well-motivated new-physics particles, as they can appear in dark-sector portal scenarios and models to explain various laboratory-based anomalies. Due to their low mass and feebly interacting nature, beam-dump-type experiments, utilizing high-intensity particle beams, can play a crucial role in probing the parameter space of such visibly decaying mediators—in particular, the “prompt decay” region, where the mediators feature relatively large coupling and mass. We present a general and semianalytic proof that the ceiling effectively arises in the prompt-decay region of an experiment and show its insensitivity to data statistics, background estimates, and systematic uncertainties, considering a concrete example, the search for axion-like particles interacting with ordinary photons at three benchmark beam facilities: PIP-II at FNAL, and SPS and LHC-dump at CERN. We then identify optimal criteria to perform a cost-effective and short-term experiment to reach the ceiling, demonstrating that very short-baseline compact experiments enable access to the parameter space unreachable thus far.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Demonstration of a code coupling framework for modeling beam-collimator impacts in the advanced photon source

The high-brightness beams being produced in current and future accelerators present new machine protection concerns with the potential for high-energy-density (HED) conditions ( >100 J/mm 3 ) in beam-intercepting components. Simulating HED conditions in accelerators requires utilizing a suite of physics codes for particle dynamics, particle-matter interactions, and hydrodynamics. This paper describes a method of coupling the codes elegant, fluka, and flash to simulate the effects of a rapid beam loss in the advanced photon source storage ring and the resulting interaction of the beam and collimators. This paper expands previous work [J. Dooling et al., Collimator irradiation studies at the advanced photon source, in Proceedings of the IBIC-2023 (2023), pp. 245–249] by introducing a definition of the evolving geometry of the collimator surface as well as providing methods for simulating the absorption of synchrotron radiation and tracking shower particles produced during beam strikes. We demonstrate this framework by simulating machine conditions of the APS ring before and after its recent upgrade. Simulation results are compared with observed damage to collimators and test samples taken from the APS ring.

Accelerator/storage ring control systems↗

Single-Shot Reconstruction of Electron Beam Longitudinal Phase Space in a Laser Wakefield Accelerator

We report on a single-shot longitudinal phase-space reconstruction diagnostic for electron beams in a laser wakefield accelerator via the experimental observation of distinct periodic modulations in the angularly resolved spectra. Such modulated angular spectra arise as a result of the direct interaction between the ultrarelativistic electron beam and the laser driver in the presence of the wakefield. A constrained theoretical model for the coupled oscillator, assisted by a genetic algorithm, can recreate the experimental electron spectra and, thus, fully reconstructs the longitudinal phase-space distribution of the electron beam with a temporal resolution of approximately 1.3 fs. In particular, it reveals the slice energy spread of the electron beam, which is important to measure for applications such as x-ray free electron lasers. In our experiment, the root-mean-square energy spread retrieved is bounded at 9.9 MeV, corresponding to a 0.9%–3.0% relative spread, despite the overall GeV energy beam having approximately 100% relative energy spread.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Delivery of H - / H + Beams to Area A

We explore the relative merits of transporting the beam from the H + ion source and from the H - ion source to Area-A for low current applications. Transporting the H - beam to Area-A using the laser neutralization approach has some risk associated with it and will require some development. Alternative method of delivering H - beam to Area-A includes replacing LDBM00 bending magnet with kicker for sharing beam between Line D and modified Line A. Transporting the H + beam to Area-A will have significant impact on the operation the IPF facility and maintaining high pulse rate to IPF will require major modifications to the transition region of the accelerator and Drift Tube Linac.

43 PARTICLE ACCELERATORS↗

Simulation and measurement of beam-induced heating of ceramic vacuum chambers

In this article, we summarize recent theoretical and experimental studies of the impedance and beam-induced heating of titanium-coated ceramic vacuum chambers used in the NSLS-II injection kickers. The impedance was calculated using the field matching theory assuming planar approximation and compared with the mpedanceake2 code. For the coating thickness of a few microns, we demonstrated that the beam-induced power is dissipated in the titanium coating and that the longitudinally averaged two-dimensional power density is approximated by an analytical expression, thus allowing the use of a simplified model of the power density as input for the code to simulate the temperature distribution with realistic nonuniform thickness of the Ti coating. For a few values of the NSLS-II beam current, we measured the beam-induced heating of two ceramic chambers using thermal sensors installed along the chamber and compared the measurement results with the simulations. Published by the American Physical Society 2024

36 MATERIALS SCIENCE↗

Peak‐in‐Valley Metal Nano‐Architectures via E‐Beam‐Guided Metal Oxide Redox

Focused electron beams enable nanoscale material modification via localized etching or deposition. In liquid-phase electron-beam-mediated processing, radiolysis-driven redox reactions present an opportunity to control both etching and deposition simultaneously. Here, this duality using a water-ammonia solvent as a tunable redox mediator on copper surfaces is demonstrated. At lower ammonia concentrations, the oxidation process dominates, etching copper to sub-50-nm depths. The copper ions and ion-complexes released during this initial oxidation step are reduced by solvated electrons resulting in metal deposition into the etched sites, over longer e-beam exposures, producing characteristic peak-in-valley nanostructures. Conversely, at higher ammonia concentrations copper-ammine ion complexation and radiolytic oxidizing species scavenging by ammonia occur at higher rates, creating a reducing environment conducive to rapid beam-guided copper deposition. Reaction-transport simulations and experiments are performed to show the effects of ammonia-mediated radiolysis chemistry, describing the direct influence of solvent concentration on redox balance and the outcome of e-beam guided processing. By uniting both etching and deposition within a single framework, this work provides a versatile route for controlled surface nanostructuring.

copper nanostructures↗

Isotope harvesting from a NSCL beam blocker: Isolation of 173,174 lu

A decommissioned beam blocker from the National Superconducting Cyclotron Laboratory was processed for recovery of long-lived Lu radioisotopes at Lawrence Livermore National Laboratory. The beam blocker was a W alloy that had built up considerable levels of activation from high energy particle irradiation over the course of 20 years. The isolation of 173,174 Lu from the bulk material required a complex chemical separation scheme due to the large mass and the wide variety of elements present. The final yield of 173,174 Lu was 76.7 ± 4.8% with an extremely high radiopurity and chemical purity. The reduction in W mass from the initial material to the final sample was 8 × 10 10 . In conclusion, the results show great promise for extracting large quantities of Lu radioisotopes from these types of W beam blockers at the Facility for Rare Isotope Beams, which will be irradiated at levels significantly higher than the beam blocker investigated here.

and nuclear chemistry↗

Ion-beam radiation-induced Eshelby transformations: The mean and variance in hydrostatic and shear residual stresses

Ion beam plays a pivotal role in ion implantations and the fabrication of nanostructures. However, there lacks a quantitative model to describe the residual stresses associated with the ion-beam radiation. Radiation-induced residual stress/transformation strain have been mostly recognized in the hydrostatic sub strain space. Here, in this study, we use molecular dynamics (MD) simulations to show that the response of a material to irradiation is generally anisotropic that depends on the ion-beam direction, and should be described using tensorial quantities. We demonstrate that accelerator-based ion beam irradiation, combined with the intrinsic lattice anisotropy and externally induced anisotropy (such as anisotropic mechanical loadings), causes radiation-actuated shear transformation strains in addition to hydrostatic expansion. We map out these complex correlations for several materials. Radiation-induced defects are shown to be responsible for residual shear stresses in the manner of Eshelby inclusion transformation. We propose such tensorial response model should be considered for accurate nanoscale fabrication using ion-beam irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quasi-optical beam tracing module development for millimeter-wave high-wavenumber collective scattering on the NSTX-U and EAST tokamaks

A Python3-based beam tracing code utilizing Quasi-Optics has been developed to track both incident and receiving beams in high-k collective millimeter wave scattering systems within magnetic fusion plasmas. In contrast to existing ray tracing codes that solely consider refraction, this beam tracing code incorporates diffraction phenomena, providing a more comprehensive calculation. Here, this enhanced capability allows for a more accurate calculation of the scattering volume and spatial resolution in high-k collective scattering systems, crucial for evaluating system performance and facilitating data analysis. Unlike Geometrical Optics, Quasi-Optics employs the complex eikonal method, representing a Gaussian beam as a collection of coupled rays to accurately preserve diffraction characteristics. The developed code is intended for application in NSTX-Upgrade and EAST high-k beam tracing analyses, targeting frequencies of 693 GHz and 270 GHz, respectively. The high-k system's primary objective is the observation of electron-scale instabilities. Employing a symplectic integrator, the code ensures numerical accuracy, assessed through the conservation of the Hamiltonian. With its precision and efficiency, the code facilitates rapid inter-shot analyses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

E-beam-enhanced solid-state mechanical amorphization of α-quartz: Reduced deformation barrier via localized excess electrons as network modifiers

Under hydrostatic pressure, α-quartz (α-SiO 2 ) undergoes solid-state mechanical amorphization wherein the interpenetration of [SiO 4 ] 2- tetrahedra occurs and the material loses crystallinity. This phase transformation requires a high hydrostatic pressure of 14GPa because the repulsive forces resulting from the ionic nature of the Si–O bonds prevent the severe distortion of the atomic configuration. Herein, we experimentally and computationally demonstrate that e-beam irradiation changes the nature of the interatomic bonds in α-quartz and enhances the solid-state mechanical amorphization at nanoscale. Specifically, during in situ uniaxial compression, a larger permanent deformation occurs in α-quartz submicron pillars compressed during e-beam irradiation than in those without e-beam irradiation. Microstructural analysis reveals that the large permanent deformation under e-beam irradiation originates from the enhanced mechanical amorphization of α-quartz and the subsequent viscoplastic deformation of the amorphized region. Further, atomic-scale simulations suggest that the delocalized excess electrons introduced by e-beam irradiation move to highly distorted atomic configurations and alleviate the repulsive force, thus reducing the barrier to the solid-state mechanical amorphization. In conclusion, these findings deepen our understanding of electron–matter interactions and can be extended to new glass forming and processing technologies at nano- and microscale.

36 MATERIALS SCIENCE↗

Molten pool dynamics and humping suppression in high-speed laser welding via tailored beam configurations

High-speed laser welding is essential for increasing the production rate of fuel cell fabrication. However, when the welding speed exceeds a critical limit, humping occurs and reduces the weld quality. In this study, two tailored beam configurations, including an adjustable ring mode and a dual-beam configuration, were employed to suppress humping. Computational fluid dynamics simulations were performed to elucidate the underlying suppression mechanisms. Here, the results show that, in the adjustable ring mode, humping mitigation arises from a reduced backward cross-sectional melt flow rate and a more stable molten pool. In the dual-beam configuration, humping suppression is attributed to the deceleration of melt flow, the conduction-mode behavior of the trailing beam, and the widening of the molten pool induced by the trailing laser. Furthermore, because the dual-beam configuration directly modifies the trailing molten pool dynamics, it achieves more effective humping suppression, extending the welding speed limit to 1.50 m/s, compared with 1.00 m/s for the adjustable ring mode.

08 HYDROGEN↗

Effects of low-temperature neutron irradiation on the microstructure and tensile properties of duplex 2304 stainless steel and its electron-beam welds

A lean duplex stainless steel material (2304-grade) in its base metal and electron beam (e-beam) welded conditions were studied microstructurally and mechanically as a function of irradiation conditions to evaluate its use as a structural material at low temperatures (60–100 °C). Neutron irradiation up to a fluence of 1.40 × 10 19 n/cm 2 (E > 0.1 MeV) or ~0.011 dpa decreased the total elongation of both base metal and e-beam welded samples. Overall, radiation hardening was observed in all the samples. The transversely cut irradiated samples showed some nonuniform quasi-cleavage and shearing in their fracture surfaces, indicating the variance of ductile nature of the two-phased (deformable austenite and harder ferrite) duplex structure. The e-beam welded samples also showed quasi-cleavage fracture, which is a characteristic of radiation-induced embrittlement. Furthermore, these observations of the e-beam welded samples were attributed to the formation of coarse ferrites, grain boundary and intragranular phases such as γ 2 and γ 3 , and minor impurity phases such as CrN and Cr 2 N in the weld pool and/or heat-affected zone of the samples. Radiation-induced elemental segregation was also identified in the post-irradiated base metal.

36 MATERIALS SCIENCE↗

The new Batch Mode Ion Source for stand-alone operation at the Facility for Rare Isotope Beams (FRIB)

Gas stoppers have been used for a long-standing successful science program at Michigan State University with stopped and rare-isotope beams produced by projectile fragmentation. The National Superconducting Cyclotron Laboratory’s Coupled Cyclotron Facility has recently transitioned into the Facility for Rare Isotope Beams (FRIB) laboratory to provide rare isotopes using a high-power superconducting linear accelerator and new production facilities. To allow the science program with stopped and reaccelerated beams to continue during the transition period, a stand-alone capability was added. The Batch Mode Ion Source (BMIS) was built and has been providing beams of long-lived and stable isotopes of a variety of elements for successful user experiments. Finally, the BMIS system is described and results from the production of various beams are presented.

47 OTHER INSTRUMENTATION↗

Direct comparison of gamma, electron beam and X-ray irradiation doses on characteristics of low-density polyethylene, polypropylene homopolymer, polyolefin elastomer and chlorobutyl rubber medical device polymers

There is a growing need for increased efficiency in the sterilization of single use medical devices and other products that contain polymer components. Gamma radiation is widely used for devices suited for radiation sterilization; however, safety, throughput and cobalt-60 source availability are challenging the prospect of relying on gamma radiation to meet the anticipated needs of the industry. Use of electron beam (e-beam) and X-rays as alternatives to gamma for radiation sterilization have been hampered in part by a concern that these modalities may adversely affect polymer integrity and performance relative to the gamma method, for which the industry has had much more experience. To address this concern, the effects of sterilization-relevant doses of ebeam, X-ray and gamma radiation were directly compared using common medical device polymers found in two prototypical commercial devices currently sterilized using cobalt-60 gamma irradiation. The Becton, Dickinson and Company (BD) Vacutainer™ Plus tube contains low-density polyethylene and chlorobutyl rubber components, while the BD Vacutainer™ Push Button Blood Collection Set contains polypropylene homopolymer and polyolefin elastomer components. Injection-molded samples prepared from the polymers used in these products were exposed to target doses of 15, 35, 50 and 80 kGy using gamma, e-beam and X-ray radiation. Changes in coloration, tensile properties and hardness were measured for each condition, and the effects of e-beam and X-ray irradiation compared with the effects of gamma irradiation on these properties. Both e-beam and X-ray appear as viable alternatives to gamma irradiation for sterilization of the polymers tested.

sterilization, gamma, X-ray, electron beam, radiat↗

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam↗

Origin and Suppression of Beam Damage-Induced Oxygen-K Edge Artifact from γ-Al 2 O 3 using Cryo-EELS

Gamma-alumina (γ-Al 2 O 3 ), like other low-Z oxides, is readily damaged when exposed to an electron beam. This typically results in the formation of a characteristic pre-edge peak in the oxygen-K edge of electron energy-loss spectra (EELS) acquired during or after the damage process. This artifact can mask the presence of intrinsic O-K edge fine structure that would reveal chemical properties of the material; therefore, its suppression is key. In this work, we systematically investigate the conditions that give rise to the damage-induced O-K pre-edge peak and show that it can be effectively suppressed by performing EELS experiments at cryogenic (cryo) temperatures. Prolonged exposure of γ-Al 2 O 3 to a focused electron beam results in a hole bored through the sample; this was used as a reproducible beam damage condition. O-K edge EELS spectra were collected from a single-crystal γ-Al 2 O 3 sample both during and after focused 2 electron beam hole drilling, and at room and cryo temperatures, using a monochromated scanning transmission electron microscope (STEM). Furthermore, the characteristic 531 eV pre-edge peak visible in the room temperature EELS spectra was completely suppressed in the cryo-EELS spectra, even in the presence of a visible drilled hole. We then correlated these experimental observations with multiple-scattering EELS simulations to determine the likely atomistic origin of the damage-induced O-K pre-edge peak. The findings indicate that the pre-edge peak is caused primarily by the presence of surface O dimer (O-O) bonds formed during beam damage, and that operating at cryo temperature suppresses the formation of surface O-O bonds, thus preventing formation of the O-K pre-edge peak. Additionally, Al-L 2,3 edge EELS spectra revealed Al loss primarily from tetrahedral sites during hole drilling.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Contrast Mechanisms in Secondary Electron e-Beam-Induced Current (SEEBIC) Imaging

Abstract Over the last few years, a new mode for imaging in the scanning transmission electron microscope (STEM) has gained attention as it permits the direct visualization of sample conductivity and electrical connectivity. When the electron beam (e-beam) is focused on the sample in the STEM, secondary electrons (SEs) are generated. If the sample is conductive and electrically connected to an amplifier, the SE current can be measured as a function of the e-beam position. This scenario is similar to the better-known scanning electron microscopy-based technique, electron beam-induced current imaging, except that the signal in the STEM is generated by the emission of SEs, hence the name secondary electron e-beam-induced current (SEEBIC), and in this case, the current flows in the opposite direction. Here, we provide a brief review of recent work in this area, examine the various contrast generation mechanisms associated with SEEBIC, and illustrate its use for the characterization of graphene nanoribbon devices.

47 OTHER INSTRUMENTATION↗

Validating and optimizing mismatch tolerance of Doppler backscattering measurements with the beam model (invited)

In this work, we use the beam model of Doppler backscattering (DBS), which was previously derived from beam tracing and the reciprocity theorem, to shed light on mismatch attenuation. This attenuation of the backscattered signal occurs when the wavevector of the probe beam’s electric field is not in the plane perpendicular to the magnetic field. Correcting for this effect is important for determining the amplitude of the actual density fluctuations. Previous preliminary comparisons between the model and Mega-Ampere Spherical Tokamak (MAST) plasmas were promising. In this work, we quantitatively account for this effect on DIII-D, a conventional tokamak. We compare the predicted and measured mismatch attenuation in various DIII-D, MAST, and MAST-U plasmas, showing that the beam model is applicable in a wide variety of situations. Finally, we performed a preliminary parameter sweep and found that the mismatch tolerance can be improved by optimizing the probe beam’s width and curvature at launch. This is potentially a design consideration for new DBS systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗