Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “analytical sensitivity analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Raman Spectroscopy for Analysis of Thorium Compounds

The thorium fuel cycle is an alternative to the uranium fuel cycle in that when 232Th is irradiated with neutrons it is converted to 233U, another fissile isotope. There are several chemical forms of thorium which are used in the Th fuel cycle. Recently, Raman spectroscopy has become a very portable and facile analytical technique useful for many applications, including e.g. determining the chemical composition of different materials such as for thorium compounds. The technique continues to improve with the development of ever-more sensitive instrumentation and better software. Using a laboratory Fourier-transform (FT)-Raman spectrometer with a 785 nm wavelength laser, we were able to obtain Raman spectra from a series of thorium-bearing compounds of unknown origin. These spectra were compared to the spectra of in-stock-laboratory thorium compounds including ThO2, ThF4, Th(CO3)2 and Th(C2O4)2. The unknown spectra showed very good agreement to the known standards, demonstrating the applicability of Raman spectroscopy for detection and identification of these nuclear materials.

Su, Yin-Fong↗

Charge Recombination Dynamics in Sensitized SnO 2 /TiO 2 Core/Shell Photoanodes

Studies have been conducted to examine the mechanisms of charge recombination in dye-sensitized SnO 2 /TiO 2 core/shell films. Nanostructured SnO 2 /TiO 2 core/shell films varying in TiO 2 shell thicknesses were prepared via atomic layer deposition and sensitized with a phosphonate-derivatized ruthenium chromophore [Ru(bpy) 2 (4,4$'$-(PO 3 H 2 ) 2 bpy)] 2+ . Transient absorption spectroscopy was used to study the interfacial charge recombination dynamics for these core/shell materials. Charge recombination for sensitized, as-deposited SnO 2 /TiO 2 core/shell systems is dominated by a tunneling mechanism for shell thicknesses between 0 and 3.2 nm, with $β$ = 0.25 Å–1. For shell thicknesses greater than 3.2 nm, recombination primarily proceeds directly via electrons localized in the relatively thick TiO 2 shell. Annealing the SnO 2 /TiO 2 core/shell structure at 450°C affects the recombination dynamics substantially; charge recombination dynamics for the annealed films do not show a dependence on shell thickness and are comparable to ZrO 2 /TiO 2 control samples, suggesting the annealing process perturbs the core/shell interface. This analysis of charge recombination dynamics indicates that there is an optimum shell thickness to maximize charge separation lifetimes in dye-sensitized core/shell photoanodes and that the nature of the core/shell interface influences the efficacy of these materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The U.S. national nuclear forensics library, nuclear materials information program, and data dictionary

Nuclear forensics assessments to determine material process history requires careful comparison of sample data to both measured and modeled nuclear material characteristics. Developing centralized databases, or nuclear forensics libraries, to house this information is an important step to ensure all relevant data will be available for comparison during a nuclear forensics analysis and help expedite the assessment of material history. The approach most widely accepted by the international community at this time is the implementation of National Nuclear Forensics libraries, which would be developed and maintained by individual nations. This is an attractive alternative toan international database since it provides an understanding that each country has data on materials produced and stored within their borders, but eliminates the need to reveal any proprietary or sensitive information to other nations. To support the concept of National Nuclear Forensics libraries, the United States Department of Energy has developed a model library, based on a data dictionary, or set of parameters designed to capture all nuclear forensic relevant information about a nuclear material. Specifically, information includes material identification, collection background and current location, analytical laboratories where measurements were made, material packaging and container descriptions, physical characteristics including mass and dimensions, chemical and isotopic characteristics, particle morphology or metallurgical properties, process history including facilities, and measurement quality assurance information. While not necessarily required, it may also be valuable to store modeled data sets including reactor burn-up or enrichment cascade data for comparison. It is fully expected that only a subset of this information is available or relevant to many materials, and much of the data populating a National Nuclear Forensics library would be process analytical or material accountability measurement data as opposed to a complete forensic analysis of each material in the library.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

On the pair correlations of nuclear fission neutrons with small relative momenta

The theoretical analysis of pair correlations of low-energy neutrons produced in nuclear fission is performed on the basis of the general method of pair correlations of particles at small relative momenta. The analytical approach to the description of the effect of final-state interaction on narrow pair correlations of neutrons is used. It is shown that, at small but nonzero values of relative momenta, the two-neutron correlation function is sensitive to the Fermi statistics and final-state interaction effects only for pairs of scission neutrons, whereas for ordinary fission neutrons (emitted from fission fragments) these correlation effects are absent. Thus, the correlation method makes it possible, in principle, to determine the fraction of pairs of scission neutrons in the total amount of neutron pairs emitted in some fission process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TH-EF-BRB-10: Dosimetric Validation of a Trajectory Based Cranial SRS Treatment Technique On a Varian TrueBeam Linac

Purpose: This work investigates the dosimetric accuracy of a trajectory based delivery technique in which an optimized radiation beam is delivered along a Couch-Gantry trajectory that is formed by simultaneous rotation of the linac gantry and the treatment couch. Methods: Nine trajectory based cranial SRS treatment plans were created using in-house optimization software. The plans were calculated for delivery on the TrueBeam STx linac with 6MV photon beam. Dose optimization was performed along a user-defined trajectory using MLC modulation, dose rate modulation and jaw tracking. The pre-defined trajectory chosen for this study is formed by a couch rotation through its full range of 180 degrees while the gantry makes four partial arc sweeps which are 170 degrees each. For final dose calculation, the trajectory based plans were exported to the Varian Eclipse Treatment Planning System. The plans were calculated on a homogeneous cube phantom measuring 18.2×18.2×18.2 cm3 with the analytical anisotropic algorithm (AAA) using a 1mm3 calculation voxel. The plans were delivered on the TrueBeam linac via the developer’s mode. Point dose measurements were performed on 9 patients with the IBA CC01 mini-chamber with a sensitive volume of 0.01 cc. Gafchromic film measurements along the sagittal and coronal planes were performed on three of the 9 treatment plans. Point dose values were compared with ion chamber measurements. Gamma analysis comparing film measurement and AAA calculations was performed using FilmQA Pro. Results: The AAA calculations and measurements were in good agreement. The point dose difference between AAA and ion chamber measurements were within 2.2%. Gamma analysis test pass rates (2%, 2mm passing criteria) for the Gafchromic film measurements were >95%. Conclusion: We have successfully tested TrueBeam’s ability to deliver accurate trajectory based treatments involving simultaneous gantry and couch rotation with MLC and dose rate modulation along the trajectory.

60 APPLIED LIFE SCIENCES↗

On the pair correlations of nuclear fission neutrons with small relative momenta

The theoretical analysis of pair correlations of low-energy neutrons produced in nuclear fission is performed on the basis of the general method of pair correlations of particles at small relative momenta. The analytical approach to the description of the effect of final-state interaction on narrow pair correlations of neutrons is used. It is shown that, at small but nonzero values of relative momenta, the two-neutron correlation function is sensitive to the Fermi statistics and final-state interaction effects only for pairs of scission neutrons, whereas for ordinary fission neutrons (emitted from fission fragments) these correlation effects are absent. Thus, the correlation method makes it possible, in principle, to determine the fraction of pairs of scission neutrons in the total amount of neutron pairs emitted in some fission process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ambient Ion Trapping and Separations for High Throughput Structurally Selective Material Deposition

While ion mobility coupled to mass spectrometry (IMS/MS) has been increasingly adapted to biological analysis, the structural and molecular specificity offered by IMS/MS has untapped potential for creating novel materials (for energy, catalysis, biomolecular switches etc.) with rationally tailored properties by precisely controlling the chemical structure and composition of these materials. While electrochemical and catalytic properties of the bulk material are understood by mass-selective ion-soft-landing, different structures of one molecule can exhibit distinct properties from the bulk. Many biological phenomenon occur at interfaces and are highly structurally specific. IMS/MS offers means to separate molecules in a sample (which is first ionized and released to gas phase from the condensed phase) based on mass and structure. Species thus separated can potentially be deposited onto surfaces with molecular and structural specificity, to perform fundamental investigations for understanding critical interfacial phenomenon. Key performance metrics for IMS/MS analysis are resolution of separations and sensitivity. Recently developed Structures for Lossless Ion Manipulations (SLIM)4 enabled unprecedented resolution in IMS separations. In addition, high sensitivity was enabled in SLIM due to lossless confinement of ions using radio frequency fields. Thus, SLIM enabled extremely long path length separations (up to 0.1 km thus far) providing efficient separation of molecular ions never before achieved (e.g. isotopologues, D&L amino acids). While SLIM has unprecedented analytical separations power/utility, the use of SLIM platform for depositing mobility and mass selected molecular ions has two specific technological challenges: (a) Pulsed nature of IMS separations and their low duty cycle and (b) the need for a low vacuum of ~4 torr for lossless ion confinement. These limitations lead to long deposition times due to loss of ions generated from the sample. Enabling ion confinement at atmospheric pressure will be path-breaking contribution to the fundamental understanding of ion manipulations and separations and will also enable novel science currently precluded due to the inability of the present technologies to confine ions under ambient conditions. Traditionally used radio frequency fields are ineffective in confining ions at high pressures due to ion/neutral collisions. To address these, we propose to (a) develop methods for confining and manipulating ions for lossless IMS separations at atmospheric pressure enabling high sensitivity and throughput and (b) use the high specificity of IMS/MS and high throughput from ambient ion confinement to perform mobility and mass selective ion deposition at atmospheric pressure. Our goal is to enable the study of the fundamental properties of energy/catalysis materials and biomolecules. This project paves the way for high-throughput, mass and structure selective material deposition for highly specific surface creation/functionalization (discussed in Section 2 of the report). Further, the developments reported continue to push the boundaries of this process to ambient conditions (discussed in Section 3 of the report). We conclude with a list of specific intellectual property and publications which have been the outcome of this funded project.

36 MATERIALS SCIENCE↗

Spectroscopic Chemical Analysis Methods and Apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Spectroscopic Chemical Analysis Methods and Apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

LeWRON: Agentic Analysis of Electroweak Phase Transitions

The electroweak phase transition (EWPT) is a central topic in particle physics and cosmology, connecting collider phenomenology, baryogenesis, and gravitational-wave observatories. Its analysis requires a technically demanding, convention-sensitive, and model-dependent pipeline, from constructing the finite-temperature effective potential to tracking thermal histories, computing bubble nucleation rates, and predicting gravitational-wave spectra. We present LeWRON (Learning ElectroWeak phase tRansitiON), an agentic framework that orchestrates this pipeline starting from an input Lagrangian. LeWRON combines audited toolbox construction with an Explorer module that uses the generated model-specific code for further analysis, including scans and plots. Intermediate analytic outputs are checked by auditor agents and stored as structured artifacts, enabling reproducible human inspection and downstream use through both a command-line interface and a public Python API. The framework supports a reproduction mode, which infers conventions from the literature and reproduces published results, and a discovery mode, which guides users through structured checkpoints for new models. We demonstrate LeWRON across representative beyond-the-Standard-Model scenarios and release the code on GitHub.

Wang, Isaac R. [Fermilab] (ORCID:000000030789218X)↗

Mapping of lanthanide-tagged proteins on western blot paper using microextraction-inductively coupled plasma-mass spectrometry

A microextraction (ME) sampling system, paired with inductively coupled plasma-mass spectrometry (ICP-MS), was employed to spatially analyze proteins tagged with lanthanum (La), gadolinium (Gd), or terbium (Tb) on the surface of western blot paper. The proteins were covalently tagged, separated via gel electrophoresis, and transferred to western blot paper for analysis by ME-ICP-MS. The ME-ICP-MS method enables the direct sampling of the tagged species on the western blot paper, without any sample preparation. Traditionally, the tagged analyte would need to be stained, excised, and digested to be analyzed by ICP-MS for its elemental and isotopic characterization. Preliminary detection limits for the ME-ICP-MS method applied to western blot paper were established to be 564, 54, and 2.5 fg for La, Gd, and Tb, respectively. The developed ME-ICP-MS method was compared to laser ablation (LA) ICP-MS, another direct solid sampling technique; it was readily determined that ME-ICP-MS can effectively map the elemental constituents on the western blot paper with comparable analysis time and measurement sensitivity. The analysis time per 2 × 4 mm extraction is ∼1 minute; if protein spots are directly targeted (rather than systematically mapping the entire blot paper), the analysis time per protein spot is ∼1 min. This developed method proved to be fast, effective, and accessible for correlating protein molecular weight with the detection of the inorganic tagant. The ME-ICP-MS approach could be widely applicable in research areas that involve metal-tagged protein bioconjugates, such as in the development of diagnostic and therapeutic agents and other biochemical probes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating the Utility of Permethylated Polysaccharide Solution NMR Data for Characterization of Insoluble Plant Cell Wall Polysaccharides

Plant cell wall polysaccharide analysis encompasses the utilization of a variety of analytical tools, including gas and liquid chromatography, mass spectrometry (MS), and nuclear magnetic resonance (NMR) spectroscopy. These methods provide complementary data, which enable confident structural proposals of the many complex polysaccharide structures that exist in the complex matrices of plant cell walls. However, cell walls contain fractions of varying solubilities, and a few techniques are available that can analyze all fractions simultaneously. We have discovered that permethylation affords the complete dissolution of both soluble and insoluble polysaccharide fractions of plant cell walls in organic solvents such as chloroform or acetonitrile, which can then be analyzed by a number of analytical techniques including MS and NMR. In this work, NMR structure analysis of 10 permethylated polysaccharide standards was undertaken to generate chemical shift data providing insights into spectral changes that result from permethylation of polysaccharide residues. This information is of especial relevance to the structure analysis of insoluble polysaccharide materials that otherwise are not easily investigated by solution-state NMR methodologies. The preassigned NMR chemical shift data is shown to be vital for NMR structure analysis of minor polysaccharide components of plant cell walls that are particularly difficult to assign by NMR correlation data alone. With the assigned chemical shift data, we analyzed the permethylated samples of destarched, alcohol-insoluble residues of switchgrass and poplar by two-dimensional NMR spectral profiling. Thus, we identified, in addition to the major polysaccharide components, two minor polysaccharides, namely, <5% 3-linked arabinoxylan (switchgrass) and <2% glucomannan (poplar). In particular, the position of the arabinose residue in the arabinoxylan of the switchgrass sample was confidently assigned based on chemical shift values, which are highly sensitive to local chemical environments. Furthermore, the high resolution afforded by the 1H NMR spectra of the permethylated switchgrass and poplar samples allowed facile relative quantitative analysis of their polysaccharide composition, utilizing only a few milligrams of the cell wall material. As a result, the concepts herein developed will thus facilitate NMR structure analysis of insoluble plant cell wall polysaccharides, more so of minor cell wall components that are especially challenging to analyze with current methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis and design of insulation systems for LH2-fueled aircraft

An analytical program was conducted to evaluate the performance of 15 potential insulations for the fuel tanks of a subsonic LH2-fueled transport aircraft intended for airline service in the 1990-1995 time period. As a result, two candidate insulation systems are proposed for subsonic transport aircraft applications. Both candidates are judged to be the optimum available and should meet the design requirements. However, because of the long-life cyclic nature of the application and the cost sensitivity of airline operations, an experimental tank/insulation development or proof-of-concept program is recommended. This program should be carried out with a nearly full-scale system which would be subjected to the cyclic thermal and mechanical inputs anticipated in aircraft service.

Cunnington, G. R., Jr.↗

Quantum dots in proteomic studies and medical diagnostics

Modern medical diagnostics requires the detection of minor amounts of target proteins at the background of numerous different biological components. With rare exception, these problems cannot be solved by purely physical research methods. In this case, the simplest and efficient approach is concerned with the principles of complementary affine interactions of biopolymers. In this case, high sensitivity of the analysis is achieved by the introduction of labels with certain physical properties in affinity bioreagents. This review is focused on the development of proteomic studies and medical diagnostics with the use of colloidal quantum dots (QDs) as labels in affinity bioreagents. This review is devoted to the description of in vitro proteomic approaches used in the studies and diagnostics, where the problem related to toxicity is not as crucial as in therapy and no restrictions on the types and composition of QDs are imposed. In this case, QDs are considered to be one of the key components of a bioanalytical system. The problems of proteomic medical diagnostics are discussed from the viewpoint of analytical chemistry with the account for the structure and properties of macromolecular analytes and appropriate bioreagents.

60 APPLIED LIFE SCIENCES↗

Heat capacity measurements of sub-nanoliter volumes of liquids using bimaterial microchannel cantilevers

Lab-on-a-Chip compatible techniques for thermal characterization of miniaturized volumes of liquid analytes are necessary in applications such as protein blotting, DNA melting, and drug development, where samples are either rare or volume-limited. We developed a closed-chamber calorimeter based on a bimaterial microchannel cantilever (BMC) for sub-nanoliter level thermal analysis. When the liquid-filled BMC is irradiated with infrared (IR) light at a specific wavelength, the IR absorption by the liquid analyte results in localized heat generation and the subsequent deflection of the BMC, due to a thermal expansion mismatch between the constituent materials. The time constant of the deflection, which is dependent upon the heat capacity of the liquid analyte, can be directly measured by recording the time-dependent bending of the BMC. We have used the BMC to quantitatively measure the heat capacity of five volatile organic compounds. With a deflection noise level of ∼10 nm and a signal-to-noise ratio of 68:1, the BMC offers a sensitivity of 30.5 ms/(J g{sup −1 }K{sup −1}) and a resolution of 23 mJ/(g K) for ∼150 pl liquid for heat capacity measurements. This technique can be used for small-scale thermal characterization of different chemical and biological samples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamically tunable membrane metasurfaces for infrared spectroscopy and strong light-matter interactions

Mid-infrared spectroscopy enables biochemical sensing by identifying vibrational molecular fingerprints, but it faces limitations in instrumentation portability and analytical sensitivity. Optical metasurfaces with strong mid-infrared photonic resonances provide an attractive solution towards on-chip spectrometry and sensitive molecular detection, yet their static nature hinders their anticipated impact. Here, we introduce and demonstrate dynamically tunable silicon membrane metasurfaces exhibiting high-Q transmissive resonances in the fingerprint region. By harnessing silicon’s thermo-optical properties, we achieve continuous modulation of coupling-induced transparency (CIT) modes that emerge upon the interference of quasi-bound states in the continuum (q-BICs) and surface lattice modes (SLMs). We measure a spectral tuning rate of 0.06 cm −1 K −1 by continuously sweeping the sharp CIT resonances over a 23.5 cm −1 spectral range across a temperature range of 300–700 K. In the current proof‑of‑concept implementation, the dynamic transmission control enables non-contact chemical analysis of polymer films by detecting characteristic absorption bands of polystyrene (1450 and 1492 cm −1 ) and poly(methyl methacrylate) (1730 cm −1 ) without requiring conventional spectrometers. When analyte molecules fill the metasurface-generated photonic cavities, we demonstrate vibrational strong coupling between the poly(methyl methacrylate)’s carbonyl band and the CIT mode, manifested in a Rabi splitting of ~43 cm −1 . Our results establish a new photonic platform that unites spectral precision, strong field enhancement, and reconfigurability, offering diverse potential for compact mid-infrared spectroscopy, molecular sensing, and programmable polaritonic photonics.

74 ATOMIC AND MOLECULAR PHYSICS↗

Investigation of Fundamental Modeling and Thermal Performance Issues for a Metallic Thermal Protection System Design

A study was performed to develop an understanding of the key factors that govern the performance of metallic thermal protection systems for reusable launch vehicles. A current advanced metallic thermal protection system (TPS) concept was systematically analyzed to discover the most important factors governing the thermal performance of metallic TPS. A large number of relevant factors that influence the thermal analysis and thermal performance of metallic TPS were identified and quantified. Detailed finite element models were developed for predicting the thermal performance of design variations of the advanced metallic TPS concept mounted on a simple, unstiffened structure. The computational models were also used, in an automated iterative procedure, for sizing the metallic TPS to maintain the structure below a specified temperature limit. A statistical sensitivity analysis method, based on orthogonal matrix techniques used in robust design, was used to quantify and rank the relative importance of the various modeling and design factors considered in this study. Results of the study indicate that radiation, even in small gaps between panels, can reduce significantly the thermal performance of metallic TPS, so that gaps should be eliminated by design if possible. Thermal performance was also shown to be sensitive to several analytical assumptions that should be chosen carefully. One of the factors that was found to have the greatest effect on thermal performance is the heat capacity of the underlying structure. Therefore the structure and TPS should be designed concurrently.

Blosser, Max L.↗