Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “acceptance sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Absolute absorption cross sections of ozone in the 185- to 350-nm wavelength range

The absorption cross sections of ozone have been measured in the wavelength range 185-350 nm and in the temperature range 225-298 K. The absolute ozone concentrations were established by measuring the pressure of pure gaseous samples in the 0.08to 300-torr range, and the UV spectra were recorded under conditions where less than 1 percent of the sample decomposed. The temperature dependence is significant for wavelengths longer than about 280 nm. The absorption cross-section values around 210 nm were found to be about 10 percent larger than the previously accepted values.

Molina, L. T.↗

Operations concepts for Mars missions with multiple mobile spacecraft

Missions are being proposed which involve landing a varying number (anywhere from one to 24) of small mobile spacecraft on Mars. Mission proposals include sample returns, in situ geochemistry and geology, and instrument deployment functions. This paper discusses changes needed in traditional space operations methods for support of rover operations. Relevant differences include more frequent commanding, higher risk acceptance, streamlined procedures, and reliance on additional spacecraft autonomy, advanced fault protection, and prenegotiated decisions. New methods are especially important for missions with several Mars rovers operating concurrently against time limits. This paper also discusses likely mission design limits imposed by operations constraints .

Dias, William C.↗

EXPERIMENTAL RESULTS FOR THE ISOTOPIC EXCHANGE OF A 1600 LITER TITANIUM HYDRIDE STORAGE VESSEL

Titanium is used as a low pressure tritium storage material. The absorption/desorption rates and temperature rise during air passivation have been reported previously for a 4400 gram prototype titanium hydride storage vessel (HSV). A desorption limit of roughly 0.25 Q/M was obtained when heating to 700 C which represents a significant residual tritium process vessel inventory. To prepare an HSV for disposal, batchwise isotopic exchange has been proposed to reduce the tritium content to acceptable levels. A prototype HSV was loaded with deuterium and exchanged with protium to determine the effectiveness of a batch-wise isotopic exchange process. A total of seven exchange cycles were performed. Gas samples were taken nominally at the beginning, middle, and end of each desorption cycle. Sample analyses showed the isotopic exchange process does not follow the standard dilution model commonly reported. Samples taken at the start of the desorption process were lower in deuterium (the gas to be removed) than those taken later in the desorption cycle. The results are explained in terms of incomplete mixing of the exchange gas in the low pressure hydride.

36 MATERIALS SCIENCE↗

Per- and Polyfluoroalkyl Substances Confirmatory Sampling Report, South Repeater Building (SWMU 121), Kennedy Space Center, Florida

This Per- and Polyfluoroalkyl Substances (PFAS) Confirmatory Sampling (CS) Report was prepared by AECOM Technical Services, Inc. (AECOM) for the National Aeronautics and Space Administration (NASA) under Contract 80KSC019D0010, Task Order 80KSC021F0096. The purpose of this report is to document CS activities at the South Repeater Building, Solid Waste Management Unit (SWMU) 121, formerly known as the Area 3 Repeater Building (A3RB). A Phase I SWMU Assessment and Confirmatory Sampling Report (NASA 2019) and a Phase II and III SWMU Assessment and Confirmatory Sampling Report (NASA 2022b) were previously submitted detailing Center-Wide assessment activities performed at the John F. Kennedy Space Center (KSC) in Florida that identified 33 locations of concern and 19 areas of potential concern at KSC associated with the storage, use, or release of materials containing PFAS. A review of the analytical results from investigation derived waste samples collected in 2020 from the South Repeater Building area indicated concentrations of perfluorooctanesulfonic acid (PFOS) were above Florida Department of Environmental Protection (FDEP) provisional Groundwater Cleanup Target Levels of 70 nanograms per liter (ng/L) at a concentration of 1,750 ng/L. Following this review, the KSC Fire Chief was contacted; the Chief recalled fighting a brush fire in 1998 in the area, during which an unknown volume of aqueous film-forming foam was used to extinguish the fire. The Phase II and Phase III SWMU Assessment Report recommended this area proceed to CS. Historical results in this area are provided in Appendix A . PFAS CS activities were contracted at the South Repeater Building. Initial CS activities were conducted in accordance with the PFAS Assessment and Mitigation Work Plan (AECOM 2022), which was submitted to the NASA Remediation Project Management team and accepted by the team on November 1 and 8, 2021. The objectives of the PFAS CS were to: - - Confirm and begin to assess the extent of PFAS affected media in the South Repeater Building area. - - Identify locations for groundwater, soil, surface water, and soil core sampling. - - Qualitatively characterize the migration potential of released PFAS to environmental media (soil, groundwater, and surface water). The following activities were completed to meet the PFAS CS objectives: - - Installation of monitoring wells via direct push technology (DPT) and rotosonic techniques - - Groundwater, soil, and surface water sampling - - Collection of soil cores to evaluate site lithology - - Development of initial PFAS plume characterization

PFAS↗

Acceptance testing of the prototype electrometer for the SAMPIE flight experiment

The Solar Array Module Plasma Interaction Experiment (SAMPIE) has two key instruments at the heart of its data acquisition capability. One of these, the electrometer, is designed to measure both ion and electron current from most of the samples included in the experiment. The accuracy requirement, specified by the project's Principal Investigator, is for agreement within 10 percent with a calibrated laboratory instrument. Plasma chamber testing was performed to assess the capabilities of the prototype design. Agreement was determined to be within 2 percent for electron collection and within 3 percent for ion collection.

Hillard, G. Barry↗

Data sharing report characterization of the surveillance and maintenance project miscellaneous process inventory waste items Oak Ridge National Laboratory, Oak Ridge, TN

The U.S. Department of Energy (DOE) Oak Ridge Office of Environmental Management (EM-OR) requested Oak Ridge Associated Universities (ORAU), working under the Oak Ridge Institute for Science and Education (ORISE) contract, to provide technical and independent waste management planning support under the American Recovery and Reinvestment Act (ARRA). Specifically, DOE EM-OR requested ORAU to plan and implement a sampling and analysis campaign to target certain items associated with URS|CH2M Oak Ridge, LLC (UCOR) surveillance and maintenance (S&M) process inventory waste. Eight populations of historical and reoccurring S&M waste at the Oak Ridge National Laboratory (ORNL) have been identified in the Waste Handling Plan for Surveillance and Maintenance Activities at the Oak Ridge National Laboratory, DOE/OR/01-2565&D2 (WHP) (DOE 2012) for evaluation and processing for final disposal. This waste was generated during processing, surveillance, and maintenance activities associated with the facilities identified in the process knowledge (PK) provided in Appendix A. A list of items for sampling and analysis were generated from a subset of materials identified in the WHP populations (POPs) 4, 5, 6, 7, and 8, plus a small number of items not explicitly addressed by the WHP. Specifically, UCOR S&M project personnel identified 62 miscellaneous waste items that would require some level of evaluation to identify the appropriate pathway for disposal. These items are highly diverse, relative to origin; composition; physical description; contamination level; data requirements; and the presumed treatment, storage, and disposal facility (TSDF). Because of this diversity, ORAU developed a structured approach to address item-specific data requirements necessary for acceptance in a presumed TSDF that includes the Environmental Management Waste Management Facility (EMWMF)—using the approved Waste Lot (WL) 108.1 profile—the Y-12 Sanitary Landfill (SLF) if appropriate; EnergySolutions Clive; and the Nevada National Security Site (NNSS) (ORAU 2013b). Finally, the evaluation of these wastes was more suited to a judgmental sampling approach rather than a statistical design, meaning data were collected for each individual item, thereby providing information for item-byitem disposition decisions. ORAU prepared a sampling and analysis plan (SAP) that outlined data collection strategies, methodologies, and analytical guidelines and requirements necessary for characterizing targeted items (ORAU 2013b). The SAP described an approach to collect samples that allowed evaluation as to whether or not the waste would be eligible for disposal at the EMWMF. If the waste was determined not to be eligible for EMWMF disposal, then there would be adequate information collected that would allow the waste to be profiled for one of the alternate TSDFs listed above.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Multiplicity Trigger for long-lived particles in CMS detector

Searches for long-lived particles (LLPs) at the CMS experiment often involve unconventional event topologies that are difficult to efficiently select using standard trigger strategies. To improve sensitivity to such signatures during LHC Run 3 operation, a dedicated High Multiplicity Trigger (HMT) has been developed and deployed in the CMS trigger system. The trigger targets events containing unusually large numbers of hits in the CMS cathode strip chamber (CSC) muon detectors, a characteristic signature of several LLP scenarios involving displaced decays in the muon system. The HMT implementation, trigger logic, rate dependence with pileup, and operational stability are described. Optimized hit multiplicity thresholds are used to maintain acceptable trigger rates under high-luminosity and high-pileup conditions while preserving high efficiency across a broad range of LLP lifetimes and kinematic regimes. The trigger performance is evaluated using both simulated event samples and proton-proton collision data collected during Run 3 of the LHC. The HMT substantially extends the CMS sensitivity to non-standard signatures associated with LLP decays and provides a flexible platform for future searches for physics beyond the Standard Model.

47 OTHER INSTRUMENTATION↗

Characterization and Sampling of Ultralow Permeability Geomaterials using Electrokinetics (LDRD Final Report 209234)

This final report on Laboratory Directed Research and Development (LDRD) project 209234 presents background material for electrokinetics at the pore and porous media scales. We present some theoretical developments related to uncoupling electrokinetic flow solutions, from a manuscript recently accepted into Mathematical Geosciences for publication. We present a summary of two pore-scale modeling efforts undertaken as part of the academic alliance with University of Illinois, resulting in one already submitted journal publication to Transport in Porous Media and another in preparation for submission to a journal. We finally show the laboratory apparatus built in Laboratory B59 in Building 823 and discuss some of the issues that occurred with it.

58 GEOSCIENCES↗

Longitudinal Solid P Longitudinal Solid Polarized Target for CL get for CLAS12 and Study of Spin AS12 and Study of Spin Structure of Nucleons

A suite of experiments measuring target-spin observables in electron-nucleon scattering (dubbed Run Group C) was conducted at Jefferson Lab's Hall B in Newport News, VA with a new polarized nuclear target known as 'APOLLO' (Ammonia POLarized LOngitudinally). This innovative target is engineered to seamlessly integrate with the advanced 12GeV CEBAF (Continuous Electron Beam Accelerator Facility) accelerator and the Hall B CLAS12 (12 GeV CEBAF Large Acceptance Spectrometer) detector array. The 'APOLLO' target harnesses the power of Dynamic Nuclear Polarization (DNP) to achieve longitudinal polarization of solid ammonia, thereby creating a net polarization in both protons (NH3) and deuterons (ND3). These samples are subjected to a 5 Tesla magnetic field produced by the CLAS12 spectrometer central solenoid, cooled to 1 K using helium evaporation, and subsequently exposed to microwave radiation at a frequency of 140 GHz. This project was made possible through a collaborative partnership between the Jefferson Lab Target Group, Old Dominion University, University of Virginia, Christopher Newport University, and the CLAS Collaboration. Integrating the APOLLO target into CLAS12 presented unique challenges because of its specific spatial and dimensional constraints. This dissertation will highlight the innovative solutions developed to address these challenges, including the creation of a new target material transport system, the incorporation of superconducting magnetic correction coils, and the development of a customized Nuclear Magnetic Resonance (NMR) system. In addition to a detailed description of the development and operation of APOLLO, and an overview of RGC, this document also describes the global data fitting of proton asymmetries in the Deep Inelastic scattering (DIS) and the Resonance regions, and it offers insights into the comprehensive analysis of target polarization data.

Pandey, Pushpa↗

Towards Fast and Accurate Predictions of Radio Frequency Power Deposition and Current Profile via Data-driven Modeling

Three machine learning techniques (multilayer perceptron, random forest, and Gaussian process) provide fast surrogate models for lower hybrid current drive (LHCD) simulations. A single GENRAY/CQL3D simulation without radial diffusion of fast electrons requires several minutes of wall-clock time to complete, which is acceptable for many purposes, but too slow for integrated modeling and real-time control applications. The machine learning models use a database of 16,000+ GENRAY/CQL3D simulations for training, validation, and testing. Latin hypercube sampling methods ensure that the database covers the range of 9 input parameters ($n_{e0}$, $T_{e0}$, $I_p$, $B_t$, $R_0$, $n_{||}$, $Z_{eff}$, $V_{loop}$, $P_{LHCD}$) with sufficient density in all regions of parameter space. The surrogate models reduce the inference time from minutes to ~ms with high accuracy across the input parameter space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermophysical properties of foodstuffs

Minimum overall nutritional deterioration of foodstuffs is generally attained by maximizing the rate of heat input and minimizing the duration of heating. Measurement of thermophysical data for foodstuffs is discussed in terms of specific heat, latent energy, enthalpy, thermal conductivity, thermal diffusivity, and density. Since phase change in foodstuffs occurs over a temperature range rather than at a discrete temperature, enthalpy is preferred over sensible and latent energy measurements as it can be used to fix the state of a sample very accurately; also, in the fusion process there is no precise way of separating sensible and latent energies. The first step in determining property data for foodstuffs is to describe the material in conventionally accepted terms. Future work should be concentrated in the area of thermal diffusivity and enthalpy measurements.

Witte, L. C.↗

Lunar and Planetary Science XXXII

This CD-ROM publication contains the extended abstracts that were accepted for presentation at the 32nd Lunar and Planetary Science Conference held at Houston, TX, March 12-16, 2001. The papers are presented in PDF format and are indexed by author, keyword, meteorite, program and samples for quick reference.

Source record↗

Lunar and Planetary Science XXXIII

This CD-ROM publication contains the extended abstracts that were accepted for presentation at the 33rd Lunar and Planetary Science Conference held in Houston, TX, March 11-15, 2002. The papers are presented in PDF format and are indexed by author, keyword, meteorite, program and samples for quick reference.

Source record↗

Resolution Versus Error for Computational Electron Microscopy

Images that are collected via scanning transmission electron microscopy (STEM) can be undersampled to avoid damage to the specimen while maintaining resolution [1, 2]. We have used BPFA to impute missing data and reduce noise [3]. The reconstruction is typically evaluated using the peak signal-to-noise ratio (PSNR). This measure is too conservative for STEM images and we propose that the Fourier ring correlation (FRC) is used instead to evaluate the reconstruction. We are not concerned with exact reconstruction of the truth image, and therefore PSNR is a conservative estimation of the quality of the reconstruction. Instead, we are concerned with the visual resolution of the image and whether atoms can be distinguished. We have evaluated the reconstruction of a simulated STEM image using the FRC and compared the results with the PSNR measurements. The FRC captures the resolution of the image and is not affected by a large MSE if the atom peaks are still distinguishable. The noisy and reconstructed images are shown in Figure 1. The simulated STEM image was sampled at 100%, 80%, 40%, and 20% of the original pixels to simulate an undersampled scan. The reconstruction was done using BPFA with a patch size of 10 x 10 and no overlapping patches. Not having overlapping patches produces inferior results but they are still acceptable. The dictionary size is 64 and 30 iterations were completed during each reconstruction. The 100% image was denoised instead of reconstructed. Poisson noise was applied to the simulated image with λ values of 500, 50, and 5 to simulate lower imaging dose. The original simulated STEM image was also included in our calculations and was generated using a dose of 1000. The simulated STEM image is 100 by 100 pixels and has essentially no high frequency components. The image reconstruction tends to smooth the data, also resulting in no high frequency components. This causes the FRC of the two images to be large at higher resolutions and may be misleading. For this reason, the BPFA has no overlap to avoid excessive smoothing. Moreover, the resolution of the simulated image is approximately 9.2 (1/nm), so we only look that far in the frequency domain when performing FRC. If the FRC curve does not crossover the threshold, a resolution value of 9.2 is used. We emphasize that our reported results are conservative. The FRC and PSNR values using the ground truth and the reconstructed images are shown in Tables 1 and 2. The left side show the metrics without using BPFA (missing pixels) and the right side show the metrics after using BPFA. When we did not use BPFA, the Fourier transform was estimated [4]. Some threshold curves have been studied [5], but they are derived for additive noise models. Since we have a Poisson noise model, we have used the more conservative threshold of 0.5 for our calculations. Ten images were used to construct each cell of tables in the form of the mean of the metric plus or minus its standard deviation. As expected, the PSNR dies off much quicker than the FRC values for the same image. For the 100% and 80% sampled versions of the truth image, the resolution only dies off when the dose is 5. However, the PSNR dies off rapidly as the dose is reduced. For the 1000, 500, and 50 dose images, the FRC is the maximum, or close, until we undersample at 20%. The PSNR for these values tapers down as we get into the bottom right hand corner of the table, even though the resolution remains high. Overall, we find that undersampled images can be reconstructed to acceptable resolution even when the dose per pixel is also reduced[6]. References: [1]A Stevens, H Yang, L Carin et al. Microscopy 63(1), (2014), pp. 41. [2]A Stevens, L Kovarik, P Abellan et al. Advanced Structural and Chemical Imaging 1(1), (2015), pp. 1. [3]M Zhou, H Chen, J Paisley et al. Image Processing, IEEE Transactions on 21(1), (2012), pp. 130. [4]V. Y. Liepin’sh. Automatic control and computer sciences 30(3), (1996), pp. 20.

Luzi, Lorenzo↗

In Situ Monitoring of Groundwater Contamination for Sustainable Remediation Using the Kalman Filter - 18423

Groundwater monitoring is critical for nuclear-related facilities as well as radioactively contaminated sites. Recent advances in sensing, data analytics and simulation capabilities provide substantial opportunities to improve and change current monitoring procedures. In particular, we need a paradigm shift from contaminant-only or compliance-only monitoring programs to comprehensive monitoring, i.e., including other ancillary environmental variables for a holistic understanding of the groundwater systems and plume behaviors. Such new approaches are needed for the effective implementation of sustainable remediation (enhanced and natural attenuation), and they have great potential for cost reduction in site monitoring. This paper reviews recent developments for improving long-term monitoring, with focus on the effective use of in situ sensors, data analytics and simulation capabilities. In particular, we highlight a recent application of the Kalman filter algorithm to estimate contaminant concentrations continuously in real time, based on in-situ measured water quality parameters (e.g. electrical conductance and pH) and sparse groundwater sampling. The results show that we can reduce the groundwater sampling frequency significantly, while capturing the dynamics of short- and long-term contaminant concentration changes. Such advanced and integrated monitoring systems will be beneficial for local residents (e.g., to ensure the safety by detecting adverse events early, enabling a swift response) as well as for site operators (e.g., to gain/improve public acceptance, to be better prepared for litigations and false claims, and to reduce overall monitoring cost). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SALTSTONE 1QCY11 TCLP RESULTS

A Saltstone waste form was prepared in the Savannah River National Laboratory (SRNL) from a Tank 50H sample and Z-Area premix material for the first quarter of calendar year 2011 (1QCY11). After the prescribed 28 day cure, samples of the saltstone were collected, and the waste form was shown to meet the South Carolina Hazardous Waste Management Regulations (SCHWMR) R.61-79.261.24 and R.61-79.268.48(a) requirements for a nonhazardous waste form with respect to RCRA metals and underlying hazardous constituents. These analyses met all quality assurance specifications of USEPA SW-846. The Saltstone Production Facility (SPF) receives waste from Tank 50H for treatment. In the first quarter of the 2011 calendar year (1QCY11), Tank 50H accepted transfers of approximately 15 kgal from the Effluent Treatment Project (ETP), approximately 15 kgal from Tank 710 - the H-Canyon General Purpose Evaporator, approximately 73 kgal from the H-Canyon Super Kukla campaign, approximately 285 kgal from the Actinide Removal Process/Modular Caustic Side Solvent Extraction Unit (ARP/MCU) Decontaminated Salt Solution Hold Tank (DSS-HT), and approximately 21 kgal from other sources. The Saltstone Grout Sampling plan provides the South Carolina Department of Health and Environmental Control (SCDHEC) with the chemical and physical characterization strategy for the salt solution which is to be disposed of in the Z-Area Solid Waste Landfill (SWLF). During operation, samples were collected from Tank 50H and grout samples prepared to determine the non-hazardous nature of the grout to meet the requirements of the South Carolina Hazardous Waste Management Regulations (SCHWMR) R.61-79.261.24(b) and R.61-79.268.48(a). Savannah River National Laboratory (SRNL) was asked to prepare saltstone from samples of Tank 50H obtained January 5, 2011 during 1QCY11 to determine the non-hazardous nature of the grout. The samples were cured and shipped to Babcock & Wilcox Technical Services Group-Radioisotope and Analytical Chemistry Laboratory (B&W TSG-RACL) to perform the Toxic Characteristic Leaching Procedure (TCLP) and subsequent extract analysis on saltstone samples for the analytes required for the quarterly analysis saltstone sample. In addition to the eight toxic metals-arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver-analytes included the underlying hazardous constituents (UHC) antimony, beryllium, nickel, and thallium which could not be eliminated from analysis by process knowledge. B&W TSG-RACL provided subsamples to GEL Laboratories, LLC for analysis for the UHCs benzene, phenols and total and amenable cyanide.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radioactive waste immobilization of Hanford sludge in magnesium potassium phosphate ceramic forms

Here, this paper evaluates immobilization of Hanford K-Basin tank sludge in magnesium potassium phosphate ceramic forms. The waste forms were produced using two simulated non-radioactive sludge streams, each with distinct characteristics and composition. Ceramicrete with wollastonite as filler was used as the matrix for this purpose. The resulting waste forms were tested for their mechanical properties, radiation stability, and leaching resistance. In another series of tests, the samples were vitrified in borosilicate glass and glass waste forms were produced. The Product Consistency Test, the American Nuclear Society's ANS 16.1 test, and the Toxicity Characteristic Leaching Procedure, which are used to develop waste acceptance criteria in the United States for permanent storage of treated waste, were used for evaluation of the leaching resistance of all waste forms.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Impedance Humidity Sensor Based on CVD Grown WSe 2 2D Films

2D materials-based planar devices have been sought after for gas and humidity sensor applications owing to their high sensitivity due to their ultrathin nature and increased surface area. Herein, 2D WSe 2 films-based planner devices were fabricated to evaluate their performance for potential application in humidity sensors. The structure and morphology of the WSe 2 sensing films were studied by Raman spectroscopy, photoluminescence, optical microscopy, and scanning electron microscopy (SEM) techniques. The relative humidity-dependent sensing performances of the 2D WSe 2 films were evaluated using current–voltage (I–V), relative impedance, and complex total impedance (electrochemical impedance spectroscopy, EIS) techniques. This sensor showed a very stable and repeatable performance investigated over the period of 18 months. The response and recovery times of the WSe 2 -based impedance sensors were found to be 40 and 30 s, respectively. The WSe 2 sensor exhibits a 2 ± 1% minimum hysteresis at a lower humidity level (50% RH) and around 8 ± 2% maximum hysteresis at relative humidity level (70% RH). This value of hysteresis is in the acceptable range during the initial investigation of any material to explore its potential for application in humidity sensors. The density functional theory (DFT) analysis was performed with the interaction from water molecules of the WSe 2 sample for a better understanding of the sensing mechanism of devices.

2D- WSe2↗