Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Inverse Method for Noninvasive Material Discrimination with Multienergy X-Ray Radiography

Active x-ray inspections have great potential for noninvasive detection of illicit materials. Dual-energy x-ray radiography, in particular, has been used to determine material composition by utilizing the energy-dependence of the x-ray attenuation coefficients. However, current implementations of this method are limited in their ability to determine the material composition of composite objects. Here, in this paper, we present an inverse algorithm that uses multienergy x-ray radiography data to noninvasively reconstruct the contents of a container. A critical feature of the current contribution is that material identification can be performed using conventional detectors and x-ray spectra with different endpoint energies produced by varying nothing more than the tube voltage. Adaptive regularization is used to increase the accuracy of material estimations from multienergy data sets. The utility of these methods is demonstrated with experimentally acquired radiographs obtained using a tunable x-ray source that produces spectra with endpoint energies of 100–450 keV. The object inspected is a scale model of a nuclear materials storage container composed of three-dimensional printed plastic and stainless-steel spheres inside a thin-walled steel container. Reconstructions of the steel sphere thicknesses are within a root-mean-square error of 0.37 cm.

47 OTHER INSTRUMENTATION↗

Small-wedge synchrotron and serial XFEL datasets for Cysteinyl leukotriene GPCRs

Structural studies of challenging targets such as G protein-coupled receptors (GPCRs) have accelerated during the last several years due to the development of new approaches, including small-wedge and serial crystallography. Here, we describe the deposition of seven datasets consisting of X-ray diffraction images acquired from lipidic cubic phase (LCP) grown microcrystals of two human GPCRs, Cysteinyl leukotriene receptors 1 and 2 (CysLT 1 R and CysLT 2 R), in complex with various antagonists. Five datasets were collected using small-wedge synchrotron crystallography (SWSX) at the European Synchrotron Radiation Facility with multiple crystals under cryo-conditions. Two datasets were collected using X-ray free electron laser (XFEL) serial femtosecond crystallography (SFX) at the Linac Coherent Light Source, with microcrystals delivered at room temperature into the beam within LCP matrix by a viscous media microextrusion injector. All seven datasets have been deposited in the open-access databases Zenodo and CXIDB. Here, we describe sample preparation and annotate crystallization conditions for each partial and full datasets. We also document full processing pipelines and provide wrapper scripts for SWSX and SFX data processing. A Correction to this paper has been published: https://doi.org/10.1038/s41597-020-00759-w

97 MATHEMATICS AND COMPUTING↗

Three-dimensional hot-spot x-ray emission tomography from cryogenic deuterium–tritium direct-drive implosions on OMEGA

A three-dimensional model of the hot-spot x-ray emission has been developed and applied to the study of low-mode drive asymmetries in direct-drive inertial confinement fusion implosions on OMEGA with cryogenic deuterium–tritium targets. Here, the steady-state model assumes an optically thin plasma and the data from four x-ray diagnostics along quasi-orthogonal lines of sight are used to obtain a tomographic reconstruction of the hot spot. A quantitative analysis of the hot-spot shape is achieved by projecting the x-ray emission into the diagnostic planes and comparing this projection to the measurements. The model was validated with radiation-hydrodynamic simulations assuming a mode-2 laser illumination perturbation resulting in an elliptically shaped hot spot, which was accurately reconstructed by the model using synthetic x-ray images. This technique was applied to experimental data from implosions in polar-direct-drive illumination geometry with a deliberate laser-drive asymmetry, and the hot-spot emission was reconstructed using spherical-harmonic modes of up to ℓ = 3. A 10% stronger drive on the equator relative to that on the poles resulted in a prolate-shaped hot spot at stagnation with a large negative A 2,0 coefficient of A 2,0 = –0.47 ± 0.03, directly connecting the modal contribution of the hot-spot shape with the modal contribution in laser-drive asymmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of streaked images of x-ray self-emission in laser-driven spherical implosions

Imaging of x-ray self-emission provides a powerful in situ measurement of the spatial and temporal evolution of high-energy-density plasmas. However, interpretation of these measurements requires detailed understanding of the data-generating process. This work presents a case study in the interpretation of x-ray self-emission data for the specific application of streaked one-dimensional slit imaging of spherical laser-driven implosions. A comprehensive generative model of the streaked slit-imaging diagnostic is developed including detailed treatments of the radiation transfer, photometrics, and photostatistics associated with the measurement. The model is used to generate realistic synthetic streaked images and to analyze experimental streaked images to extract important physical quantities of interest. An example analysis of streaked images from implosion experiments on the OMEGA laser is presented, where the model developed in this work is used to constrain the trajectory and peak velocity of the implosion using Bayesian inference.

Bayesian inference↗

Annealing of focused ion beam damage in gold microcrystals: an in situ Bragg coherent X-ray diffraction imaging study

Focused ion beam (FIB) techniques are commonly used to machine, analyse and image materials at the micro- and nanoscale. However, FIB modifies the integrity of the sample by creating defects that cause lattice distortions. Methods have been developed to reduce FIB-induced strain; however, these protocols need to be evaluated for their effectiveness. Here, non-destructive Bragg coherent X-ray diffraction imaging is used to study the in situ annealing of FIB-milled gold microcrystals. Two non-collinear reflections are simultaneously measured for two different crystals during a single annealing cycle, demonstrating the ability to reliably track the location of multiple Bragg peaks during thermal annealing. The thermal lattice expansion of each crystal is used to calculate the local temperature. This is compared with thermocouple readings, which are shown to be substantially affected by thermal resistance. To evaluate the annealing process, each reflection is analysed by considering facet area evolution, cross-correlation maps of the displacement field and binarized morphology, and average strain plots. The crystal's strain and morphology evolve with increasing temperature, which is likely to be caused by the diffusion of gallium in gold below ~280°C and the self-diffusion of gold above ~280°C. The majority of FIB-induced strains are removed by 380–410°C, depending on which reflection is being considered. These observations highlight the importance of measuring multiple reflections to unambiguously interpret material behaviour.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization and Quantification of Radiation-Induced Clusters/Precipitates in RPV Steels Using STEM-EDS and Machine Learning

Over the operational lifespan of a nuclear reactor, reactor pressure vessel (RPV) steels are subjected to significant neutron irradiation, resulting in complex microstructural changes and the consequent degradation of mechanical properties. Various physically motivated correlation models have been developed to predict neutron irradiation-induced embrittlement of RPVs under different irradiation conditions. However, the efficient and accurate characterizations and quantification of radiation-induced clusters in RPVs are still challenging, which will affect the precision of the predictive models for embrittlement of RPV components. In the DOE Visiting Faculty Program (VFP) research work at Oak Ridge National Lab (ORNL), I integrate machine learning to aid Scanning Transmission Electron Microscopy – Energy Dispersive X-ray Spectroscopy (STEM-EDS) analyses, which improve the characterization and quantification of radiation-induced clusters in RPV steels, thereby enabling more accurate predictions of material behavior under irradiation. The surveillance base- and welded- RPV steels were annealed at various temperatures of 340 °C, 450 °C and 500 °C for up to 168 hours, respectively. Afterwards, I have characterized radiation-induced clusters using advanced STEM-EDS techniques and subsequently applying machine learning algorithms to analyze and refine STEM-EDS datasets, enhancing the quantification of clusters compositions and distributions. In the end, an efficient workflow for integrating STEM-EDS data analysis with machine learning to address challenges including noise reduction has been developed. The completion of this VFP work will support bridge critical gaps in the accurate quantification of radiation-induced clusters in RPV steels using STEM-EDS and support the development of more precise models for predicting RPV embrittlement in the Light Water Reactor Sustainability program supported by Department of Energy and enhancing the collaboration between ORNL and Alred University. The outcome of the VFP project will leverage a few research papers submission to peer-reviewed journals in the relevant scientific field and a few oral presentations at national and international conferences.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Diffuse X-ray scattering from polished silicon: application of the distorted wave Born approximation

Measured diffuse X-ray scattering data for a `smooth' as well as for a `rough' silicon sample were fit to theoretical expressions within the distorted wave Born approximation (DWBA). Data for the power spectral density (PSD) for both samples were also obtained by means of atomic force microscopy and optical interferometry. The Fourier transforms of trial correlation functions were fit to the PSD data and then applied to the DWBA formalism. The net correlation functions needed to fit the PSD data for each sample comprised the sum of two terms with different cutoff lengths and different self-affine fractal exponents. At zero distance these correlation functions added up to yield net values of σ 2 = (2) 2 and (71) 2 Å 2 for the smooth and rough samples, respectively. X-ray scattering data were obtained at beamline 1-BM of the Advanced Photon Source. Data and fits at values of q z = 0.05 and 0.10 Å −1 for the smooth sample are reported. Good fits for the smooth sample were obtained at both q z values simultaneously, that is, identical fitting parameters were applied at both values of q z . The smooth sample also exhibited weak Yoneda wings and a clear distinction between the strong specular scattering and the weak diffuse scattering. Data for the rough sample were qualitatively different and exhibited very weak scattering at the specular condition in contrast to extremely large Yoneda wings. Fits for the rough sample are reported for q z = 0.04, 0.05, and 0.06 Å −1 . Although the large Yoneda wings could be fit quite well in both position and amplitude, scattering near the specular condition could not be equally well fit by applying the same fitting parameters at all values of q z . Albeit imperfect, best-fitting results at the specular condition were obtained by invoking only diffuse scattering, that is, without including a separate theoretical expression for specular scattering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X-ray crystal structure of the Escherichia coli RadD DNA repair protein bound to ADP reveals a novel zinc ribbon domain

Genome maintenance is an essential process in all cells. In prokaryotes, the RadD protein is important for survival under conditions that include DNA-damaging radiation. Precisely how RadD participates in genome maintenance remains unclear. Here we present a high-resolution X-ray crystal structure of ADP-bound Escherichia coli RadD, revealing a zinc-ribbon element that was not modelled in a previous RadD crystal structure. Insights into the mode of nucleotide binding and additional structure refinement afforded by the new RadD model will help to drive investigations into the activity of RadD as a genome stability and repair factor.

59 BASIC BIOLOGICAL SCIENCES↗

Influence of neutron irradiation on Al-6061 alloy produced via ultrasonic additive manufacturing

Samples of aluminum alloy 6061 produced via ultrasonic additive manufacturing (UAM) were irradiated in the High Flux Isotope Reactor (HFIR) up to 17.3 dpa at ~70°C while in contact with water using perforated rabbit capsules. The irradiation campaign included as-received (AR) material, specimens subjected to various post-weld heat treatments (PWHTs, including hot isostatic pressing [HIP]), and reference (wrought) alloy samples. Mechanical tensile tests, accompanied by digital image correlation (DIC) analysis, fractography, and metallography, were performed as a part of the post-irradiation evaluation. The X- and Y-specimens (i.e., oriented in the sonotrode moving and vibration directions, respectively) showed pronounced radiation hardening and ductility decrease. Specific serration flow behavior and propagation of deformation bands were observed under various material conditions up to 3.5 dpa but disappeared at 17.3 dpa. In all cases, the fracture mechanism of X- and Y-specimens was ductile; ductile dimples dominated the fracture surface. Irradiated X- and Y-specimens showed good performance, regardless of material conditions (AR or PWHT). The performance of Z-specimens oriented in the build direction was strongly dependent on the PWHT. The AR and aged specimens showed fracture stress decrease with dose, and they experienced fracture under irradiation after 3.5 dpa; specimen cross section analysis revealed specific interface degradation that was likely related to corrosion. Recrystallization significantly improved in-reactor performance. Finally, HIP suppressed interface degradation due to recrystallization and pore removal, which led to good in-reactor performance for Z-specimens.

36 MATERIALS SCIENCE↗

Laser ablation spectrometry for studies of uranium plasmas, reactor monitoring, and spent fuel safety

Nuclear security is one of the defining challenges of our time. Nuclear threats range from deliberate dispersal of radioactive material to contaminate the vital infrastructure to diversion and smuggling of special nuclear material for clandestine nuclear programs and nuclear terrorism, respectively. There is an associated need to develop and sustain the nuclear forensics capabilities, which requires the understanding of complex processes that occur in plasmas of nuclear materials. The area of nuclear safety has seen a resurgence of public interest, and there is a concomitant need to safely store used nuclear fuel and detect structural material failure in nuclear power systems, especially in innovative reactor designs envisioned for future adoption. Laser-produced plasmas are complicated extreme environments that can generate intense and rich, highly specific signatures of nuclear and radiological materials, which can then be explored in a wide range of applications. They include interdiction and rapid detection of nuclear materials, including their isotopic composition, detection over long distances, laboratory simulation of weapons effects, monitoring the condition of structural materials in dry cask storage containers, and novel instrumentation for nuclear power systems. We present a compilation of recent representative examples of the application of laser spectroscopy, and laser-induced breakdown spectroscopy in particular, to nuclear safety and security problems. A case is made that spectroscopic techniques based on laser-produced plasmas offer complementary, and sometimes unique, capabilities that motivate the continued exploration of their efficient production and understanding of the signatures they produce

(020.3260) Isotope shifts, (140.3440) Laser-induce↗

Modeling the electron cyclotron emission radiation signature from suprathermal electrons in a tokamak

An Electron Cyclotron Emission (ECE) modeling code has been developed to model ECE radiation with an arbitrary electron momentum distribution, a small oblique angle, both ordinary (O-mode) and extraordinary polarizations (X-mode), and multiple cyclotron frequency harmonics. The emission and absorption coefficients are calculated using the Poynting theorem from the cold plasma dispersion and the electron–microwave interaction from the full anti-Hermitian tensor. The modeling shows several ECE radiation signatures that can be used to diagnose the population of suprathermal electrons in a tokamak. First, in an n = 2 X-mode (X2) optically thick plasma and oblique ECE view, the modeling shows that only suprathermal electrons, which reside in a finite region of the velocity and space domains, can effectively generate cyclotron emissions to the ECE receiver. The code also finds that the O1 mode is sensitive to suprathermal electrons of both a high v ⊥ and v || , while the X2 mode is dominantly sensitive to suprathermal electrons of a high v ⊥ . Finally, the modeling shows that an oblique ECE system with both X/O polarization and a broad frequency coverage can be used to effectively yield information of the suprathermal electron population in a tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High Yield Xray Imager Final Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi MJ yield shots. A new radiation tolerant CMOS imaging array (HYPERION) is being developed to eliminate the significant background noise which limits the data quality of PDIXI. We successfully placed the contract with Advanced hCMOS Systems (AHS) to develop the HYPERION sensor, which fulfils our criteria to place long lead time item procurements by end of FY24. The HYXI Final Design Review was completed at the end of Q4 FY24 (Sep 24 th and Sep 30 th ). The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the HYPERION CMOS imaging array. In Phase 1, time-integrated x-ray images on NIF DT experiments will be collected starting in Q3 FY25. In Phase 2 of the project, time-resolved imaging with HYXI utilizing a spare microchannel plate detector back-end will begin in Q3 FY26. Phase 3 concludes the project with the installation of the HYPERION sensor array and the final performance qualification of the HYXI instrument which is scheduled for Q3 FY27 as discussed in the PDR and MRT report on this project in FY23.

42 ENGINEERING↗

4D evolution of Cr 23 C 6 precipitates in neutron-irradiated and annealed HT-UPS steel observed via synchrotron micro-computed tomography

High-temperature-ultrafine precipitate strengthened (HT-UPS) steel is a potential structural material for advanced nuclear reactors; however, its irradiation response is not well understood. This research provides insight into irradiation-induced effects, such as precipitate evolution mechanisms and four-dimensional morphological evolution, in HT-UPS steel using synchrotron micro-computed tomography. Identical specimens were characterized pre-irradiation and post-irradiation following neutron exposure up to 0.3 displacements per atom at 600 °C. Irradiation effects were also differentiated from the annealing response of precipitates. Following neutron irradiation, the average Cr 23 C 6 precipitate size reduced, affected by the synergy of nucleation and growth, ballistic dissolution, and inverse coarsening, which was observed at fluences an order of magnitude lower than previously observed. Annealing at 600 °C for 32 h increased the average Cr 23 C 6 precipitate size and decreased the phase fraction, attributed to precipitate coarsening. The precipitate morphology evolution and resultant mechanisms can be utilized to parameterize and validate microstructural models simulating radiation damage or annealing.

36 MATERIALS SCIENCE↗

A novel method to measure ion density in ICF experiments using x-ray spectroscopy of cylindrical tracers

The indirect drive approach to inertial confinement fusion has undergone important advances in the past few years. Improvements in temperature and density diagnostic methods are leading to more accurate measurements of the plasma conditions inside the Hohlraum and therefore to more efficient experimental designs. The implementation of dot spectroscopy has proven to be a versatile approach to extracting space- and time-dependent electron temperatures. In this method, a microdot of a mid-Z material is placed inside the Hohlraum and its K-shell emission spectrum is used to determine the plasma temperature. However, radiation transport of optically thick lines acting within the cylindrical dot geometry influences the outgoing spectral distribution in a manner that depends on the viewing angle. This angular dependence has recently been studied in the high energy density regime at the OMEGA laser facility, which allowed us to design and benchmark appropriate radiative transfer models that can replicate these geometric effects. By combining these models with the measurements from the dot spectroscopy experiments at the National Ignition Facility, we demonstrate here a novel technique that exploits the transport effects to obtain time-resolved measurements of the ion density of the tracer dots, without the need for additional diagnostics. Furthermore, we find excellent agreement between experiment and simulation, opening the possibility of using these geometric effects as a density diagnostic in future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of the decays $χ$ cJ → $\mathrm{nK}^0_s\overline{Λ}$ + $c.c.$

By analyzing 4.48 x 10 8 ψ(3686) events collected with the BESIII detector, we observe the decays $χ$ cJ → $\mathrm{nK}^0_s\overline{Λ}$ + $c.c.$ (J = 0, 1, 2) for the first time, via the radiative transition ψ(3686) → $γχ_{cJ}$. The branching fractions are determined to be (6.65 ± 0.26 stat ± 0.41 syst ) x 10 -4 , (1.66 ± 0.12 stat ± 0.12 syst ) x 10 -4 , and (3.58 ± 0.16 stat ± 0.23 syst ) x 10 -4 for J = 0, 1, and 2, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Requirements for an in-house synchrotron radiation source at LANL

Synchrotron measurements for diffraction characterization and high resolution tomography require: (1) unable monochromatic X-ray incident energy from 65keV to 100keV. 65keV need is defined by Ta and W absorption edges at 67keV, 100keV need is defined by need to penetrate U/Pu sample thickness of 0.5 mm (2) focused flux density of the monochromatic beam on a beam spot of ~100 µm 2 greater than 10 10 photons per second to allow some slower kinetics experiments such as heating, cooling for CTE measurements (but not quenching, solidification etc. which require <0.1 s resolution) (3) Δλ/λ resolution of 0.3% or better across the energy spectrum. This can be achieved by monochromator as long as flux needs are met in the monochromatic beam.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Non-destructive depth-resolved characterization of residual strain fields in high electron mobility transistors using differential aperture x-ray microscopy

Localized residual stress and elastic strain concentrations in microelectronic devices often affect the electronic performance, resistance to thermomechanical damage, and, likely, radiation tolerance. A primary challenge for the characterization of these concentrations is that they exist over sub-μm length-scales, precluding their characterization by more traditional residual stress measurement techniques. Here, in this study, we demonstrate the use of synchrotron x-ray-based differential aperture x-ray microscopy (DAXM) as a viable, non-destructive means to characterize these stress and strain concentrations in a depth-resolved manner. DAXM is used to map two-dimensional strain fields between the source and the drain in a gallium nitride (GaN) layer within high electron mobility transistors (HEMTs) with sub-μm spatial resolution. Strain fields at various positions in both pristine and irradiated HEMT specimens are presented in addition to a preliminary stress analysis to estimate the distribution of various stress components within the GaN layer. γ-irradiation is found to significantly reduce the lattice plane spacing in the GaN along the sample normal direction, which is attributed to radiation damage in transistor components bonded to the GaN during irradiation.

42 ENGINEERING↗

Formation of Magnetically Truncated Accretion Disks in 3D Radiation-transport Two-temperature GRMHD Simulations

Multiwavelength observations suggest that the accretion disk in the hard and intermediate states of X-ray binaries (XRBs) and active galactic nucleus transitions from a cold, thin disk at large distances into a hot, thick flow close to the black hole (BH). However, the formation, structure, and dynamics of such truncated disks are poorly constrained due to the complexity of the thermodynamic, magnetic, and radiative processes involved. We present the first radiation-transport two-temperature general relativistic magnetohydrodynamic (GRMHD) simulations of truncated disks radiating at ~35% of the Eddington luminosity with and without large-scale poloidal magnetic flux. We demonstrate that when a geometrically thin accretion disk is threaded by large-scale net poloidal magnetic flux, it self-consistently transitions at small radii into a two-phase medium of cold gas clumps floating through a hot, magnetically dominated corona. This transition occurs at a well-defined truncation radius determined by the distance out to which the disk is saturated with magnetic flux. The average ion and electron temperatures in the semiopaque corona reach, respectively, $T_i$ ≳ 10 10 K and $T_e$ ≳ 5 × 10 8 K. The system produces radiation, powerful collimated jets, and broader winds at the total energy efficiency exceeding 90%, the highest ever energy extraction efficiency from a spinning BH by a radiatively efficient flow in a GRMHD simulation. This is consistent with jetted ejections observed during XRB outbursts. The two-phase medium may naturally lead to broadened iron line emission observed in the hard state.

79 ASTRONOMY AND ASTROPHYSICS↗