At least 757 records · Page 42

Reaction Between Thin Gold Wires and Pb-Sn-In Solder (37.5%, 37.5%, 25%), Part B. The Axial Reaction Of Gold Wires Soldered To PbSnIn Solder Mounds, Its effect On Electrical Resistance And Physical Structure.

Here we describe the gold-indium reaction along gold wires soldered at both ends. It begins with the combined radial/axial reaction in the vicinity of the solder mound as seen in metallurgical sections along the axis of the wire. We show that this combined radial/axial reaction has no effect on the resistance of the system, even though it shortens the length of the gold wire while converting it to gold indide. After this radial/axial reaction is complete, a purely axial reaction begins. For thin gold wires (i.e. 38.1 {micro}m diameter) the onset of that reaction is strongly correlated with the time at which the linear reaction model predicts the complete consumption of the gold wire inside the solder mounds. This purely axial reaction converts the whole wire rapidly to gold indide, and leads to substantial resistance changes and complete distortion of the wire between the solder mounds. The reaction product is AuIn{sub 2} everywhere, but both Sn and Pb also are identified everywhere on the surface by Electron Dispersive Spectroscopy.

36 MATERIALS SCIENCE↗

Reaction Between Thin Gold Wires and Pb-Sn-In Solder (37.5%, 37.5%, 25%), Part B. The "Axial Reaction" of Gold Wires Solder To PbSnIn Solder Mounds, Its Effect on Electrical Resistance and Physical Structure

Here we describe the gold-indium reaction along gold wires soldered at both ends. It begins with the combined radial/axial reaction in the vicinity of the solder mound as seen in metallurgical sections along the axis of the wire. We show that this combined radial/axial reaction has no effect on the resistance of the system, even though it shortens the length of the gold wire while converting it to gold indide. After this radial/axial reaction is complete, a purely axial reaction begins. For thin gold wires (i.e. 38.1μm diameter) the onset of that reaction is strongly correlated with the time at which the linear reaction model predicts the complete consumption of the gold wire inside the solder mounds. This purely axial reaction converts at elevated temperatures the whole wire rapidly to gold indide, and leads to substantial resistance changes and complete distortion of the wire between the solder mounds. The reaction product is AuIn 2 everywhere, but both Sn and Pb also are identified everywhere on the surface by Electron Dispersive Spectroscopy.

36 MATERIALS SCIENCE↗

Evaluating Extinction Values using Wire Impactor Data

The purpose of the study was to compare the extinctions calculated from data obtained with the Ames Wire Impactor to extinctions measured with the SAGE H satellite system. The comparison was intended to serve as a validation of the extinctions obtained using the wire impactor data. It was felt that if the extinctions obtained by the two diverse methods agreed well, it would be an indication that the number densities measured on the wires were correct.

Source record↗

Evaluating Extinction Values Using Wire Impactor Data

The purpose of the study was to compare the extinctions calculated from data obtained with the Ames Wire Impactor to extinctions measured with the SAGE 11 satellite system. The comparison was intended to serve as a validation of the extinctions obtained using the wire impactor data. It was felt that if the extinctions obtained by the two diverse methods agreed well, it would be an indication that the number densities measured on the wires were correct. Tables and charts are presented to show the extinction values from the two different methods.

Source record↗

Current-Driven Symmetry Breaking and Spin–Orbit Polarization in Chiral Wires

The spin dynamics of electrons in chiral molecular systems remains a topic of intense interest, particularly regarding whether geometric chirality inherently induces spin polarization in current-carrying electrons. In this work, we employ ab initio real-time time-dependent density functional theory (rt-TDDFT) to directly simulate the interplay among charge current, spin, and orbital. This realtime tracking extends beyond perturbative treatments, and we analyze how nonequilibrium currents effectively lift the symmetry constraints of screw rotation and time-reversal symmetry. We find that the emergence of spin and orbital angular momenta is dynamically correlated with a concomitant loss of translational (linear) momentum, which we interpret as an intrinsic consequence of current-driven symmetry lowering. The implications of this mechanism for chirality-induced spin selectivity and spintronics device design are discussed.

chiral wire↗

Medical and surgical applications of space biosensor technology

Researchers in space life sciences are rapidly approaching a technology impasse. Many of the critical questions on the impact of spaceflight on living systems simply cannot be answered with the limited available technologies. Research subjects, particularly small animal models like the rat, must be allowed to function relatively untended and unrestrained for long periods to fully reflect the impact of microgravity and spaceflight on their behavior and physiology. These requirements preclude the use of present hard-wired instrumentation techniques and limited data acquisition systems. Implantable sensors and miniaturized biotelemetry are the only means of capturing the fundamental and critical data. This same biosensor and biotelemetry technology has direct application to Earth-based medicine and surgery. Continuous, on-line data acquisition and improved measurement capabilities combined with the ease and flexibility offered by automated, wireless, and portable instruments and data systems, should provide a boon to the health care industry. Playing a key role in this technology revolution is the Sensors 2000! (S2K!) Program at NASA Ames Research Center. S2K!, in collaboration with space life sciences researchers and managers, provides an integrated capability for sensor technology development and applications, including advanced biosensor technology development, spaceflight hardware development, and technology transfer and commercialization. S2K! is presently collaborating on several spaceflight projects with dual-use medical applications. One prime example is a collaboration with the Fetal Treatment Center (FTC) at the University of California at San Francisco. The goal is to develop and apply implantable chemical sensor and biotelemetry technology to continuously monitor fetal patients during extra-uterine surgery, replacement into the womb, through birth and beyond. Once validated for ground use, the method will be transitioned to spaceflight applications to remotely monitor key biochemical parameters in flight animals. Successful application of NASA implantable biosensor and biotelemetry technologies should accelerate the advancement of this and other modern medical procedures while furthering the exploration of life in space.

NASA Discipline General Space Life Sciences↗

Breakdown of macroscopic quantum self-trapping in coupled mesoscopic one-dimensional Bose gases

Two coupled Bose-Einstein condensates with a large population imbalance exhibit macroscopic quantum self-trapping (MQST) if the ratio of interaction energy to tunneling energy is above a critical value. Here we investigate effect of quantum fluctuations on MQST. In particular, we analyze the dynamics of a system of two elongated Bose gases prepared with a large population imbalance, where due to the quasi-one-dimensional character of the gas we no longer have true long range order, and the effect of quantum fluctuations is much more important. We show that MQST is possible in this system, but even when it is achieved it is not always dynamically stable. Using this instability one can construct states with sharply peaked momentum distributions around characteristic momenta dependent on system parameters. Our other finding is the nonmonotonic oscillating dependence of the decay rate of the MQST on the length of the wires. We also address the interesting question of thermalization in this system and show that it occurs only in sufficiently long wires.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Liquid Argon Scintillation Detection Utilizing Wavelength-Shifting Plates and Light Guides

In DUNE, the event timing provided by the detection of the relatively prompt scintillation photons will improve spatial resolution in the drift direction of the time-projection chamber (TPC) and is especially useful for non-beam physics topics such as supernova neutrinos and nucleon decay. The baseline design for the first 10kt single phase TPC fits the photon detector system in the natural gap between the wire planes of adjacent TPC volumes. A prototype photon detector design utilizes wavelength-shifter coated plates to convert the vacuum ultraviolet scintillation light to the optical and commercially-produced wavelength-shifting light guides to trap some of this light and transport it to an array of silicon photomultipliers at the end. This system and the testing performed to characterize the system and determine the efficiency are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

B218 Weld Filler Wire Characterization for Al-Li Alloy 2195

NASA Marshall Space Flight Center, Lockheed Martin Space Systems- Michoud Operations, and McCook Metals have developed an aluminum-copper weld filler wire for fusion welding aluminum lithium alloy 2195. The aluminum-copper based weld filler wire has been identified as B218, a McCook Metals designation. B218 is the result of six years of weld filler wire development funded by NASA, Lockheed Martin, and McCook Metals. The filler wire chemistry was developed to produce enhanced 2195 weld and repair weld mechanical properties over the 4043 aluminum-silicon weld filler wire, which is currently used to weld 2195 on the Super Lightweight External Tank for the NASA Space Shuttle Program. An initial characterization was performed consisting of a repair weld evaluation using B218 and 4043 weld filler wires. The testing involved room temperature and cryogenic repair weld tensile testing along with fracture toughness testing. From the testing, B218 weld filler wire produce enhanced repair weld tensile strength, ductility, and fracture properties over 4043. B218 weld filler wire has proved to be a superior weld filler wire for welding aluminum lithium alloy 2195 over 4043.

Bjorkman, Gerry↗

Prospective communications research to support fly by light/power by wire

A NASA Research Grant NAG-1-1309, Distributed Fiber Optic Systems for Commercial Aircraft, was awarded during July 1991. This report primarily constitutes a summary of findings of the original background research done at that time. NASA is embarking on a research project to design the next generation of commercial aircraft, fly by light/power by wire. The objectives of this effort are to improve commercial aircraft design by (1) reducing the weight of the aircraft to improve efficiency and (2) improving the fault tolerance and safety of the aircraft by enhancing current systems with new technologies or introducing new systems into the aircraft.

Game, David↗

The binding energy of excitons and X{sup +} and X{sup -} trions in one-dimensional systems

The exciton and trion states in semiconductor quantum wires are treated by the variational method. Simple trial functions provide an adequate precision of the calculation over a wide region of wire radii, with an arbitrary relation between the effective masses of charge carriers. The precision of the results obtained by the variational method is checked by numerical diagonalization of the Hamiltonian of excitons and positively and negatively charged trions. The asymptotic behavior of the binding energies of excitons and trions in narrow quantum wires is established in the analytical form. The structure of the excited X{sup +} trion states is analyzed in the context of the adiabatic approximation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Survey of piloting factors in V/STOL aircraft with implications for flight control system design

Flight control system design factors involved for pilot workload relief are identified. Major contributors to pilot workload include configuration management and control and aircraft stability and response qualities. A digital fly by wire stability augmentation, configuration management, and configuration control system is suggested for reduction of pilot workload during takeoff, hovering, and approach.

Ringland, R. F.↗

Packaging Technology Designed, Fabricated, and Assembled for High-Temperature SiC Microsystems

A series of ceramic substrates and thick-film metalization-based prototype microsystem packages designed for silicon carbide (SiC) high-temperature microsystems have been developed for operation in 500 C harsh environments. These prototype packages were designed, fabricated, and assembled at the NASA Glenn Research Center. Both the electrical interconnection system and the die-attach scheme for this packaging system have been tested extensively at high temperatures. Printed circuit boards used to interconnect these chip-level packages and passive components also are being fabricated and tested. NASA space and aeronautical missions need harsh-environment, especially high-temperature, operable microsystems for probing the inner solar planets and for in situ monitoring and control of next-generation aeronautical engines. Various SiC high-temperature-operable microelectromechanical system (MEMS) sensors, actuators, and electronics have been demonstrated at temperatures as high as 600 C, but most of these devices were demonstrated only in the laboratory environment partially because systematic packaging technology for supporting these devices at temperatures of 500 C and beyond was not available. Thus, the development of a systematic high-temperature packaging technology is essential for both in situ testing and the commercialization of high-temperature SiC MEMS. Researchers at Glenn developed new prototype packages for high-temperature microsystems using ceramic substrates (aluminum nitride and 96- and 90-wt% aluminum oxides) and gold (Au) thick-film metalization. Packaging components, which include a thick-film metalization-based wirebond interconnection system and a low-electrical-resistance SiC die-attachment scheme, have been tested at temperatures up to 500 C. The interconnection system composed of Au thick-film printed wire and 1-mil Au wire bond was tested in 500 C oxidizing air with and without 50-mA direct current for over 5000 hr. The Au thick-film metalization-based wirebond electrical interconnection system was also tested in an extremely dynamic thermal environment to assess thermal reliability. The I-V curve1 of a SiC high-temperature diode was measured in oxidizing air at 500 C for 1000 hr to electrically test the Au thick-film material-based die-attach assembly.

Chen, Liang-Yu↗

Short Circuiting the Controller – Missteps in Maintenance and Inspection of Process and Wiring in STS-93

The primary objective of the Space Transportation System mission 93 (STS-93) was to deploy the Chandra X-Ray Observatory. Chandra, the world's most powerful X-Ray telescope, allowed scientists from around the world to study some of the most distant and dynamic objects in the universe. Stripped of nearly 7,000 pounds of its own gear to make room for the payload, the orbiter assigned to this mission was Space Shuttle Columbia. Prior to STS-93, Columbia had flown 25 flights and was NASA's oldest and heaviest orbiter. On July 23, 1999, after two prior launch scrubs, Eileen Collins and her crew of four launched from Kennedy Space Center. About five seconds after launch, Mission Control at Johnson Space Center detected a voltage drop on one of Columbia's electrical buses. As a result of this power fluctuation, a primary and back-up Main Engine controller dropped offline. Given design redundancy, the two remaining controllers supported all three engines. If there had been any other AC bus issues, one engine of the three on the Orbiter would have shut down. The redundant set of digital computer units in each engine controller saved Columbia and her crew from a very risky contingency abort. Post-flight inspection revealed soot on a screw head and a hole in an adjacent Kapton insulated wire. The single strand of polyimide wire was located nearly half-way down the payload bay. The Shuttle Independent Assessment Team (SIAT) reported that the wire had rubbed and chaffed against a burred screw head. The burr was later determined to be the result of overtightening of the screw by a technician during a maintenance refurbishment. Alone, the burr may not have been problematic, but later, during another ground processing event, possibly years after, someone inadvertently stepped on the wiring harness. With the pressure and motion of unintended contact, some of the Kapton insulation rubbed off against the burred screw head. The SIAT suspected the wire damage was pre-existing and was caused 4 or 5 years prior to the flight. Finally, the intense vibrations during the launch sequence allowed contact between the exposed conductor and exposed metal area on the burred screw head, resulting in the arcing and shorting of the wire. Due to the quick turnaround times of Space Shuttle Orbiters, wiring issues caused from multiple maintenance events were often overlooked. Additionally, failing to incorporate thorough and early inclusion of human systems integration (HSI) applications as a crucial part of the decision process can result in these types of misshaps. In order to reduce human error associated with integrated manufacturing, maintenance, refurbishment and flight preparations, wire inspection criteria should be refined and standardized, visual inspection processes should be quantified, and technicians should be certified by specially trained instructors. This case, among many others, unveils why human error management and development of safety metrics is a vital piece in the development of complex systems, and why it should be supported aggressively and implemented program wide.

Human Systems Integration↗

Fundamental and practical limitations of FUV/EUV photon-counting image detectors

In EUV and FUV space-astronomy applications, the best contemporary detector designs are based on the use of microchannel plates due to their ability to deliver photon-counting performance with high efficiency. The major unresolved issue is the choice of position-readout system for the individual photoevents. Electrical event-readout systems are divided into two classes: the discrete wire anodes that perform coordinate digitization by wire-group selection, and the continuous centroid-position encoders for which coordinates are digitized in the associated electronics. The centroid-position encoder techniques are discussed in terms of how they overcome the four chief limitations of the discrete-wire readouts - their limited format size, their flat focal surface, their fundamental hex-channel vs squared-pixel moire pattern, and their image undersampling. With these limitations overcome, microchannel based image systems can deliver the performance demanded by the forthcoming generation of applications in space astronomy.

Lampton, M.↗

Verification of three-dimensional laser Doppler velocimeter measurements

An experimental comparison method is proposed for the verification of mean flow and turbulence measurements obtained with a three-dimensional laser Doppler velocimeter system. Such measurements can include large errors caused by problems unique to three-dimensional systems. Direct comparisons of laser and hot cross-wire measurements obtained in two-dimensional flows, as is the common practice, will not bear out all the errors associated with three-dimensional laser systems. It is proposed here that the errors may be adequately quantified by making the direct comparisons in a weakly three-dimensional turbulent shear flow. The weak three-dimensional flow ensures high accuracy of the cross-wire data while still generating sufficiently strong secondary mean flow and Reynolds shear stress so that all the laser measurements may be fully verified. This type of shear flow is easily generated by introducing a weak streamwise vortex into a nominally two-dimensional turbulent shear layer.

Mehta, R. D.↗

Ionic wind generation by a wire-cylinder-plate corona discharge in air at atmospheric pressure

A wire-cylinder-plate electrode configuration is presented to generate ionic wind with a dc corona discharge in air at atmospheric pressure. The objective of the work is to maximize the power supplied to the flow in order to increase acceleration while avoiding breakdown. Thus, the proposed experimental setup addresses the problem of decoupling the mechanism of ion generation from that of ion acceleration. Using a wire-plate configuration as a reference, we have focused on improving the topography of the electric field to (1) separate the ionization and acceleration zones in space, and (2) guide the trajectory of charged particles as parallel to the median axis as possible. In the proposed wire-cylinder-plate setup, a dc corona discharge is generated in the space between a wire and two cylinders. The ions produced by the corona then drift past the cylinders and into a channel between two plates, where they undergo acceleration. To maximize the ionic wind it is found that the geometric configuration must be as compact as possible and that the voltage applied must be right below breakdown. Experimentally, the optimized wire-plate reference setup provides a maximum flow velocity of 8 m s{sup -1}, a flow rate per unit electrode length of 0.034 m{sup 2} s{sup -1}, and a thrust per unit electrode length of 0.24 N m{sup -1}. The wire-cylinder-plate configuration provides a maximum flow velocity of 10 m s{sup -1}, a flow rate per unit electrode length of 0.041 m{sup 2} s{sup -1}, and a thrust per unit electrode length of 0.35 N m{sup -1}. This 46% increase in thrust is obtained by increasing the electric power per unit electrode length by only 16% (from 175 to 210 W m{sup -1}), which confirms the gain in efficiency obtained with the decoupled system. In comparison with a simple wire-wire corona configuration, the wire-cylinder-plate configuration increases the ionic wind velocity by up to a factor of 3, and the thrust by an order of magnitude.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗