Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Thermally Stable Single-Atom Heterogeneous Catalysts

Single-atom catalysts (SACs) have attracted extensive attention in fields related to energy, environment, and material sciences because of the high atom efficiency and the unique properties of these materials. Many approaches have hitherto been successfully established to prepare SACs, including impregnation, pyrolysis-involved processes, atom trapping, and coprecipitation. However, under typical reaction conditions, single atoms on catalysts tend to migrate or agglomerate, forming nanoclusters or nanoparticles, which lowers their surface free energy. Efforts are required to develop strategies for improving the thermal stability of SACs while achieving excellent catalytic performance. Here in this Progress Report, recent advances in the development of thermally durable single-atom heterogeneous catalysts are discussed. Several important preparation approaches for thermally stable SACs are described in this article. Fundamental understanding of the coordination structures of thermally stable single atom prepared by these methods is discussed. Furthermore, the catalytic performances of these thermally stable SACs are reviewed, including their activity and stability. Finally, a perspective of this important and rapidly evolving research field is provided.

coordination structure↗

Influence of pre-existing defects on thermal transport in nuclear graphite

Nuclear graphite is a critical material in high-temperature nuclear reactors due to its superior thermal and mechanical properties. The manufacturing process leaves multi-scale ‘pre-existing’ defects that can affect thermal transport characteristics. Because these defects are remnant of graphitization temperature, they cannot be thermally annealed. This study employs a non-thermal electron wind force (EWF) annealing technique to avoid this obstacle. 2 min of EWF treatment of the as-received graphite IG-110 at temperatures below 100 °C led up to 67% increase in thermal diffusivity and ~ 35% decrease in electrical resistivity in average. Differential scanning calorimetry also showed similar outcome for specific heat. X-ray diffraction characterization was performed by fitting a bi-modal crystallite size distribution model to reveal the enhancement in crystallinity after the EWF treatment. The findings emphasize the potential of EWF annealing for optimizing thermal performance in nuclear graphite and its implications for reactor efficiency and safety.

Annealing↗

Application of physics-informed neural networks (PINNs) solution to coupled thermal and hydraulic processes in silty sands

Abstract The accurate modeling of water and heat transport in soils is crucial for both geo-environmental and geothermal engineering. Traditional modeling methods are problematic because they require well-defined boundaries and initial conditions. Recently, physics-informed neural networks (PINNs), which incorporate partial differential equations (PDEs) to solve forward and inverse problems, have attracted increasing attention in machine learning research. In this study, we applied PINNs to tackle hydraulic and thermal transport coupling forward problems in silty sands. A fully connected deep neural network was utilized for training. This neural network model leverages automatic differentiation to apply the governing equations as constraints, based on the mathematical approximations established by the neural network itself. We conducted forward problems and compared the solutions derived from PINNs with those from Finite Element Method (FEM) simulations. The forward problem results demonstrate the PINNs model’s capability in predicting hydraulic transport, heat transport, and thermal–hydraulic coupling in silty sands under various boundary conditions. The PINNs exhibited great performance in simulating the thermal–hydraulic coupling problem. The accuracy of the PINNs solutions shows its potential for simulation in geotechnical engineering.

Feng, Yuan↗

A Chemocatalytic Route to Stereoregular Poly(3-hydroxyhexanoate) and Its Statistical and Tri-Block Copolymers

Poly(3-hydroxyhexanoate) (P3HHx)-based poly(3- hydroxyalkanoate)s (PHAs) are biologically produced, commercially implemented PHAs, but little is known in the open literature about the structure and property characterizations of discrete, authentic homopolymer P3HHx, and its copolymers with poly(3- hydroxybutyrate) (P3HB). Here, we introduce a chemocatalytic route to stereoregular (both isotactic and syndiotactic) P3HHx and PHA copolymers with P3HB, including statistical copolymer P3HBHx with various levels of 3HHx incorporation and discrete hard−soft−hard triblock copolymer P3HB-b-P3HHx-b-P3HB, and present extensive characterizations of their structures, thermal properties, and mechanical performance. The synthesis is efficiently achieved by one-pot polymerization of eight-membered di(n-propyl) and dimethyl (for copolymerization) diolides catalyzed by chiral molecular catalysts. Notably, P3HBHx can be rapidly produced in quantitative yield and exhibits high molar mass (M n up to 551 kg/mol) as well as both high modulus (up to 1.39 GPa) and ductility (up to 445%), while P3HB-b-P3HHx-b-P3HB further extends application temperature windows by possessing a unique combination of low T g (−18 °C) and high T m (154 °C) values. These findings highlight the stereomicrostructural and architectural versatility of chemocatalytic routes to PHAs, which, in turn, can be utilized to largely tune the PHA thermal properties and mechanical performance.

Biopolymers↗

Influence of Diffuse and Ground-Reflected Irradiance on the Spectral Modeling of Solar Reference Cells

Thermal Energy Storage (TES) is a key component for solar thermal applications to bridge the gap between the demand for thermal energy and the supply of solar energy, whose availability depends on the time of day and season. Thus, cost-effective packed-bed thermal containers filled with a solid storage medium have been proposed for high-temperature sensible heat storage as materials are abundant and relatively cheap. Thus, it is necessary to investigate their performance and temperature profiles during the charge-discharge cycle. Several models are available for this purpose. Typically, the more detailed a model, the greater the computational effort required to solve it, and hence a time-efficient model is needed to prevent excessively long computation times for long-term analysis. At the more basic level, the common Hughes E-NTU model and the less realistic simplified Infinite-NTU model are very important for their less time and computational effort. In this paper, the appropriateness of employing the Infinite-NTU model was evaluated to investigate the performance of a typical and scalable rock-bed TES as a case study. The results presented provide a methodology to quickly test the validity of the model and predict the temperature profile for the case under study. Accordingly, such simple charge-discharge cycle thermal performance predictions are important to plan, design, and rapidly deploy a reliable and economical solar thermal system for the supply of valuable heat to high-temperature demanding applications of power generation and industrial processes as part of a rapid shift towards non-polluting renewable energy. Keywords: Solar Thermal, TES, Packed-bed, NTU model, Temperature profile

PV modeling↗

Analysis of predicted mean vote-based model predictive control for residential HVAC systems

Model Predictive Control (MPC) is an advanced process control method that has attracted much attention in building heating, ventilation, and air conditioning (HVAC) systems. Here, this paper analyzes the optimal precooling performance in residential buildings using MPC with two different comfort indices, namely, temperature and predicted mean vote (PMV). It first formulates, for each comfort index, an optimization problem that accounts for different factors, such as weather, home thermal condition, prediction horizon, time-of use (TOU) utility rate, and rated cooling capacity. The problem is then solved, resulting in an MPC strategy that determines the HVAC on/off control signal and minimizes energy cost over a receding time horizon while maintaining thermal comfort. The energy performance difference between temperature-based and PMV-based MPC strategies is subsequently investigated, especially in light of the interior wall surface temperature and under different combinations of the factors. Extensive simulation results demonstrated that the proposed MPC strategies are adaptive and their performances depend primarily on weather, home thermal condition, and prediction horizon, while the impact of TOU utility rate and rated cooling capacity is relatively small. Because the PMV-based MPC strategy can take advantage of the lower interior wall surface temperature due to precooling, it resulted in 8–45% cost savings for the scenarios investigated and an average increase of 0.042–0.113 in the absolute value of the PMV index compared to the temperature-based MPC strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reactivity initiated accident uncertainty quantification for fuel assembly with subchannel code

UNIST CORE lab has developed a multiphysics coupling framework (MPCORE) consisting of Neutronics, Thermal Hydraulics and Fuel Performance modules. It can accommodate one-dimensional as well as sub-channel code Thermal Hydraulics (TH) module. Generally, running a transient requires more computational power due to the convergence of modules with each other. The difference between one-dimensional and sub-channel TH modules is studied in this research for a Reactivity Initiated Accident (RIA). Both TH modules are compared for a RIA uncertainty propagation in a single VERA fuel assembly with 2.11% enrichment. MPCORE is capable of analyzing the transient at any burnup point but for current work, only fresh fuel has been considered. The results have been obtained using dynamic gap heat conductance in FRAPTRAN. Peak centerline temperature, fuel enthalpy and DNBR are compared for both the approaches. The results indicate that the use of sub-channel code lead to greater safety margin for critical parameters. Computation time comparison is also presented for both the cases. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Coal-derived conductive pavement for winter de-icing: prototype, modeling, and simulation

Existing pavement de-icing methods result in high installation and maintenance costs, traffic delays, excessive weariness and corrosion, and negative environmental and safety impacts. To overcome these challenges, this paper presents an innovative pathway to designing and constructing smart self-heating pavements using a low-cost coal-char bearing asphalt material. The conductive asphalt incorporates coal char, i.e., a key byproduct of the coal pyrolysis process, into the Stone Mastic Asphalt (SMA) mixture. This asphalt containing coal-derived solid carbon exhibits highly tailorable electrical conductivity, satisfactory mechanical and thermophysical properties, and superior cost-efficiency as compared to other conductive pavement materials. The de-icing performance was also demonstrated by laboratory experiments on a bench-scale prototype. Furthermore, an efficient thermal network model was developed and validated by experiments to investigate the transient thermal behavior and energy performance of the Ohmic heating pavement system. Furthermore, the whole-year energy simulation case studies were conducted on a bridge pavement with an annual energy use of 24.6–1444.8 kWh/m 2 , showcasing its potential in field applications across cool humid, cold humid, and subarctic/arctic climate zones.

42 ENGINEERING↗

Performance Assessment of a Heat Pump Integrated with Thermal Energy Storage in Cooling & Heating Modes

Thermal Energy Storage (TES) systems have demonstrated significant potential to manage the fluctuating nature of energy demand and shifting peak loads. This technology has made significant recent advances, including new research on the integration of TES with residential and commercial Heating, Ventilation, and Air-Conditioning (HVAC) systems. In this paper, we present the use of a novel laboratory assessment framework for a prototype heat pump system integrated with latent heat phase change material-based TES. The assessment framework consists of 22 total test points (11 heating, 11 cooling) using psychrometric conditions from AHRI Standard 210/240 and includes transient conditions to evaluate TES charging and discharging modes. In addition, both continuous mode and cyclic mode were evaluated for charging and discharging to explore the benefits to TES heat transfer from repeated transient operation. The ambient conditions evaluated include heating mode charging at cold-climate heat pump conditions when winter-peaking utilities may most require demand reduction (H4Full conditions, 5°F/-15°C) and cooling mode charging at high ambient temperature that may occur during times of day when excess solar power generation results in low-cost electricity (105°F/40.6°C). The work demonstrates the demand reduction capabilities of integrating TES with HVAC, including up to 44% in cooling mode and 60% in heating mode compared to conventional HVAC equipment without TES.

25 ENERGY STORAGE↗

Multiscale Electrothermal Design of a Modular Multilevel Converter for Grid-Tied Applications

As a key feature of modular multilevel converters (MMCs), a large number of semiconductor devices are employed in the converter and distributed over a stack of submodules. Each submodule has a strict temperature limit that imposes constraints on the operating range of the converter. Different loading conditions/losses in the submodules lead to unavoidable temperature variations inside the MMC, which consequently affect the system-level performance and reliability. This paper is focused on the electrothermal analysis and design of a medium-voltage silicon carbide (SiC)-based MMC system, from submodule power semiconductors to the overall MMC system integration of multiple submodules. Loss calculations are performed to estimate the cooling requirements and aid thermal design at different levels. The performance of forced-air cooling approach is analyzed within a numerical modeling framework. Maximum temperature of the SiC power modules is predicted using numerical tools. Thermal design of the MMC cabinet with various arrangement of air inlet(s) and outlet(s) is investigated and compared from a cooling performance perspective.

CFD↗

High Power Density Thermal Energy Storage With Phase Change Material in Enhanced Compact Heat Exchangers

Abstract Performance of a novel ultracompact thermal energy storage (TES) heat exchanger, designed as a microchannel finned-tube exchanger is presented. With water as the heating–cooling fluid in the microchannels, a salt hydrate phase change material (PCM), lithium nitrate trihydrate (LiNO3 · 3H2O), was encased on the fin side. To establish the hypothesis that small-length-scale encasement (<3 mm) of PCM substantially enhances heat transfer to yield very high power-density energy storage, heat exchanger designs with 10 and 24 fins/inch were considered. They were subjected to thermal cycling, or repeated heating (melting) and cooling (freezing), with inlet fluid flow mimicking diurnal variation between 42 °C and 25 °C (representing typical arid-region conditions) over an accelerated time period. By employing salt self-seeding to obviate subcooling during cooling or recrystallization, the TES was found to exhibit stable long-term (100 heating–cooling cycles) operation with very high PCM-side heat transfer coefficients (∼100–500 W/m2 K) and storage power density (∼160–175 kW/m3). In fact, with optimization of heating–cooling fluid flowrate for given charging–discharging time period and exchanger size, power density >300 kW/m3 can be achieved. The results clearly establish that highly compact heat exchangers used as TES units can provide very high-performance alternatives to conventional ones.

Engineering↗

Multiscale Electrothermal Design of a Modular Multilevel Converter for Medium-Voltage Grid-Tied Applications

As a key feature of modular multilevel converters (MMCs), a large number of semiconductor devices are employed in the converter and distributed over a stack of submodules. Each submodule has a strict temperature limit that imposes constraints on the operating range of the converter. Different loading conditions/losses in the submodules lead to unavoidable temperature variations inside the MMC, which consequently affect the system-level performance and reliability. This paper is focused on the electrothermal analysis and design of a medium-voltage silicon carbide (SiC)-based MMC system, from submodule power semiconductors to the overall MMC system integration of multiple submodules, for grid-connected applications. Loss calculations are performed to estimate the cooling requirements and aid thermal design at different levels. The performance of a forced-air cooling approach is analyzed within a numerical modeling framework. Maximum temperature of the SiC power modules is predicted using numerical tools. Thermal design of the MMC cabinet with various arrangements of air inlet(s) and outlet(s) is investigated and compared from a cooling performance perspective. A fully resolved model of the arrangement that yields optimal results is developed to accurately predict the temperature profile of the essential components in the submodules.

computational fluid dynamics↗

Characterization of Fuel-to-Coolant Heat Transfer During Reactivity-Initiated Accidents Using Tightly Coupled Thermal Hydraulics and Fuel Thermomechanics

The reactivity-initiated accident (RIA) is a complex scenario with several tightly interacting physical phenomena. Accurately predicting fuel behavior during these transients is difficult due to limitations in the modeling of fuel-to-coolant heat transfer. Common approaches to simulate RIAs involve standalone calculations using either a fuel performance code or a thermal-hydraulic code. The complex interdependencies of thermal-hydraulic and fuel mechanical behavior suggest that a tight coupling between these codes may provide more accurate predictions of fuel-to-coolant heat transfer and cladding mechanical response. Here, RELAP5-3D and BISON are coupled in this paper to simulate RIAs, and a sensitivity analysis is performed to rank key thermal properties and two-phase heat transfer parameters relevant for fuel-to-coolant heat transfer and cladding failure mechanisms in UO 2 –Zircaloy-4 systems. Gas gap conductance, film boiling heat transfer uncertainty, pulse width, fuel-specific heat capacity, and cladding-specific heat capacity were identified as important parameters. Variations in figures of merit resulting from changes to pulse width and the material thermal properties indicate that time-dependent heat transfer rates are significant for safety-relevant mechanical parameters due to the time dependence of cladding ductility and pellet-cladding mechanical interaction loading. The results suggest that the thermal-hydraulic factors have a nonnegligible influence on the thermomechanical solution and vice versa. Tight coupling of both sets of physics is recommended to improve prediction of fuel behavior during RIAs. Highlights include the following: 1. The RELAP5-3D thermal-hydraulic code and the BISON fuel performance code are tightly coupled for simulation of RIA transients with energy depositions at the Zircaloy-4 cladding failure threshold. 2. Departure from nucleate boiling occurred for all simulated cases. Due to the ductility of fresh fuel, substantial ballooning occurred in most cases. 3. Gas gap conductance, fuel-specific heat capacity, cladding-specific heat capacity, transient pulse width, and film boiling heat transfer were the dominant thermal factors impacting the safety figures of merit at energy depositions.

Critical Heat Flux (CHF)↗

Diffusion–convection model of runaway electrons due to large magnetohydrodynamic perturbations in post-thermal quench plasmas

Systematic test particle tracing simulations for runaway electrons (REs) are performed for six post-thermal quench equilibria from DIII-D and ITER, where large scale, kink-like n = 1 (n is the toroidal mode number) magnetohydrodynamic (MHD) instabilities are found. The modeled particle guiding center orbits allow extraction of the effective diffusion–convection coefficients of REs in the presence of large three-dimensional (3D) perturbations up to 10% of the equilibrium toroidal field. With a fixed spatial distribution of the field perturbation, the RE transport coefficients along the plasma radial coordinate track reasonably well with the surface-averaged perturbation level. A substantial variation in the value of the transport coefficients—by three orders of magnitude in most cases, however, occurs with varying launching location of REs along the plasma radius. Large 3D perturbations almost always lead to comparable diffusion and convection processes, meaning that diffusion alone is insufficient to describe the particle motion. At lower (but still high) level of perturbation, the RE convection is found to be dominant over diffusion. A similar observation is made when the perturbation is too strong. In the presence of large perturbation, the dependence of the RE transport on the particle energy is sensitive to the spatial distribution of the perturbation. Based on numerically obtained RE transport coefficients, an analytic fitting model is proposed to quantify the particle diffusion and convection processes due to large MHD events in post-thermal quench plasmas. The model is shown to reasonably well reproduce the direct test particle tracing results for the RE loss fraction and can, thus, be useful for incorporating into other kinetic RE codes in order to simulate the RE beam evolution in the presence of large 3D perturbations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Concrete Thermal Energy Storage Enabling Flexible Operation without Coal Plant Cycling

The work described in this report is responsive to the Office of Fossil Energy program “Energy Storage for Fossil Power Generation.” The pilot plant built as a result of this project demonstrated the feasibility and performance of a concrete thermal energy storage (CTES) system integrated with a supercritical coal power plant. The 10 MWh electrical (>25 MWh thermal) CTES unit, developed by Storworks Power, was designed to enable flexible operation of coal plants without cycling damage. The project's key technical achievements showcase a significant advancement in energy storage technology. A modular CTES system using 42 “Bolderblocs” units was successfully designed and constructed at Alabama Power’s Plant Gaston Unit 5, with each block containing embedded stainless-steel coils in specialized, cost-effective high-temperature concrete. The system interfaced seamlessly with the plant's 3500 psig (241 barg), 1000°F (538°C) supercritical steam, demonstrating operational flexibility. Over 86 full cycles, the CTES exhibited rapid charging and discharging capabilities, effectively mimicking steam turbine feed conditions and handling varying load profiles and storage durations. Performance validation confirmed the system's ability to consistently meet design target steam conditions of 75 bar-a and ~400°C for nominal baseline discharge. The concrete material withstood repeated thermal cycling without degradation, validating earlier lab-scale tests. Integration of balance of plant components, including a condensate management system with storage tank and air-cooled condenser, minimized plant interfaces and water consumption. A robust control scheme ensured safe, automated operation across various scenarios. Key learnings from the project were invaluable: 1. Initial concrete drying and commissioning procedures were refined for future deployments, enhancing efficiency in subsequent installations. 2. System flexibility exceeded expectations, with rapid response to changing conditions. 3. Design improvements were identified including optimized insulation and piping that will enhance overall system efficiency in future deployments 4. Full cycle thermal roundtrip efficiencies exceeded 88%. While the roundtrip electrical efficiency was somewhat limited by known challenges using input steam, such constraints may be mitigated by swapping steam for hot air as thermal input. 5. A summary of key performance parameters for the pilot test and predicted performance of a full scale commercial system with specified improvements determined from the pilot are shown in Section 8. The project faced challenges, including COVID-19 delays and host plant availability constraints. However, these were overcome through adaptive planning and execution. The successful management of these obstacles demonstrated the resilience and adaptability of the project team and the robustness of the CTES technology. This successful pilot demonstrates the potential for CTES to enhance coal plant flexibility, supporting grid stability as renewable penetration increases. The validated design and operational data provide a solid foundation for scaling up to utility-scale implementations, potentially transforming how thermal plants operate in evolving energy landscapes. The system's ability to rapidly respond to changing grid conditions while maintaining high efficiency makes it a promising solution for balancing intermittent renewable energy sources. Furthermore, the project highlighted the potential for even greater efficiencies in future iterations. The use of air as an input medium could potentially eliminate the limitations observed with steam input, opening new possibilities for energy storage applications beyond coal plant integration. In conclusion, this pilot project not only achieved its primary goals but also uncovered additional benefits and potential applications of the CTES technology. It represents a significant step forward in addressing the challenges of grid stability and flexibility in an increasingly renewable-driven energy landscape.

01 COAL, LIGNITE, AND PEAT↗

Thermal conductivity suppression in uranium-doped thorium dioxide due to phonon-spin interactions

In this work, impact of low level of uranium (U) atom substitution on thermal conductivity of thorium dioxide (ThO 2 ) is investigated. ThO 2 is an electronic insulator with a wide optical band-gap and no unpaired electrons whose thermal transport is governed by phonons. U-substitution introduces unpaired f-electrons resulting in paramagnetic behavior of U-ThO 2 at room temperature, which significantly suppresses its thermal conductivity. A single crystal of U-ThO 2 with graded composition of U is grown using a hydrothermal synthesis method, and thermal conductivity measurements are performed in regions with uniform composition of U at levels of 0%, 6%, 9% and 16%. Measured thermal conductivity profiles over 77–300 K temperature range are analyzed using an analytical expression for phonon-mediated thermal transport based on Klemens-Callaway model. Temperature dependent thermal conductivity is found to deviate significantly from the Rayleigh scattering trend expected for a simple substitutional point defect with a small perturbation to mass and interatomic forces. With the resonant scattering term, observed large suppression of thermal conductivity at low temperatures can be closely reproduced. Additionally, the extracted phonon-spin coupling constants imply a nonlinear relation of phonon-spin interaction intensity with respect to U doping percentage. Our study reveals how phonon-spin scattering contributed by unpaired f-electrons in U atoms influences thermal transport in the U-ThO 2 system.

36 MATERIALS SCIENCE↗

Robust dynamic operation of high temperature electrolysis solid oxide cells

Here, this study evaluates the durability of Ni/YSZ-supported SOECs under dynamic operating conditions relevant to real-world applications. Systematic tests were conducted to assess cell performance under steam cycling (3 to 75% humidified H 2 ), mode cycling between SOFC and SOEC operation, thermal cycling (150 to 750 °C at OCV, and 600 to 800 °C at 1.3V), and redox cycling (between 50% humidified H 2 and 50% humidified N 2 ). Steam cycling, mode cycling, and thermal cycling at OCV do not significantly accelerate performance degradation. Thermal cycling at 1.3V caused minimal damage within 600 to 800 °C. Full redox cycling (multi-hour oxidation holds) induced cell structural failure, while partial redox cycling (0.5 h holds) was tolerated. Extensive characterization revealed some material evolution, namely Sr and Co secondary phase formation, within the oxygen electrode due to La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3-δ instability, especially for steam cycling and mode cycling. Minimal changes were identified within the Ni-YSZ fuel electrodes. These findings provide critical insights into SOEC reliability under dynamic conditions, supporting their application in dynamic or intermittent energy systems.

08 HYDROGEN↗