SEARCH · Engineering Papers
Results for “Thermal Control”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
TERRA Battery Thermal Control Anomaly - Simulation and Corrective Actions
The TERRA spacecraft was launched in December 1999 from Vandenberg Air Force Base, becoming the flagship of NASA's Earth Observing System program to gather data on how the planet's processes create climate. Originally planned as a 5 year mission, it still provides valuable science data after nearly 10 years on orbit. On October 13th, 2009 at 16:23z following a routine inclination maneuver, TERRA experienced a battery cell failure and a simultaneous failure of several battery heater control circuits used to maintain cell temperatures and gradients within the battery. With several cells nearing the minimum survival temperature, preventing the electrolyte from freezing was the first priority. After several reset attempts and power cycling of the control electronics failed to reestablish control authority on the primary side of the controller, it was switched to the redundant side, but anomalous performance again prevented full heater control of the battery cells. As the investigation into the cause of the anomaly and corrective action continued, a battery thermal model was developed to be used in determining the control ability remaining and to simulate and assess corrective actions. Although no thermal model or detailed reference data of the battery was available, sufficient information was found to allow a simplified model to be constructed, correlated against pre-anomaly telemetry, and used to simulate the thermal behavior at several points after the anomaly. It was then used to simulate subsequent corrective actions to assess their impact on cell temperatures. This paper describes the rapid development of this thermal model, including correlation to flight data before and after the anomaly., along with a comparative assessment of the analysis results used to interpret the telemetry to determine the extent of damage to the thermal control hardware, with near-term corrective actions and long-term operations plan to overcome the anomaly.
Electrically conductive thermal control coatings
A coating characterized by low thermal absorption, high thermal emittance and high electrical conductivity comprises: (1) a fired oxide pigment comprising a minor amount of aluminum oxide and a major amount of zinc oxide; (2) sufficient water to provide a mixture suitable for application to a substrate, is presented. The fired oxide pigment may further include a minor amount of cobalt oxide. The resulting coating is particularly useful for coating the surfaces of spacecraft and similar objects.
Thermal control of low-pressure fractionation processes
Thermal models detailing the solidification paths for shallow basaltic magma chambers (both open and closed systems) were calculated using finite-difference techniques. The total solidification time for closed chambers are comparable to previously published calculations; however, the temperature-time paths are not. These paths are dependent on the phase relations and the crystallinity of the system, because both affect the manner in which the latent heat of crystallization is distributed. In open systems, where a chamber would be periodically replenished with additional parental liquid, calculations indicate that the possibility is strong that a steady-state temperature interval is achieved near a major phase boundary. In these cases it is straightforward to analyze fractionation models of the basaltic liquid evolution and their corresponding cumulate sequences. This steady thermal fractionating state can be invoked to explain large amounts of erupted basalts of similar composition over long time periods from the same volcanic center and some rhythmically layered basic cumulate sequences.
A fluid flow analysis for convective thermal control of flight experiments
A method for thermally analyzing convectively cooled flight experiments is presented. A three-dimensional fluid flow analysis code is used to optimize air circulation patterns and to predict air velocities in thermally critical areas. The analysis results are compared with the performance characteristics of a typical isothermal free jet, and good agreement is found between velocity profiles and radial distributions for downstream flow mixing. Predicted air velocities from the fluid analysis are used to calculate forced convection coefficients for the flight experiment, and the coefficients are used in a finite difference thermal analysis code to describe the response of air temperature and heat loss for the Lidar Atmospheric Sensing Experiment during transient flight profiles. Recommendations are made for the future design of convectively cooled flight experiments.
Thermal control of ice-stream margins
The thermal balance at the base of an ice sheet near an ice-stream margin was investigated theoretically. Specifically, conditions such that the base of the ice sheet would be frozen in the absence of heat generated by the ice motion were investigated. The base of the ice stream is maintained at melting as a result of high dissipation of heat at the base associated with its fast motion over the bed. Heat dissipation in the inter-ice-stream ridge ice is presumed to be too small to maintain melting conditions on the bed there. Two opposing effects can be identified near the shear margin separating the fast and slow motions. Because the velocity of an ice stream falls off toward its margin, there is a near margin heat deficit zone where the heat generated at the bed is not, by itself, sufficient to maintain melting conditions. Without some counteracting process, the base could freeze inward toward the ice stream and cause it to narrow. The marginal shearing generates heat within the ice above the bed. This heat produces a thermal shielding effect that tends to warm the bed on both sides of the boundary between the fast and slow motion. This shielding effect, if strong enough, could produce a thawed zone beyond the fast/slow boundary. If melting at the bed by itself allows fast motion, then the ice stream would be free to widen. A coupled mass and heat flow model is being developed to examine these competing processes. Preliminary calculations using available information for boundary conditions appropriate for Ice Stream B predict that the shielding effect is most important. This tentative result suggests that thermal conditions are such that the ice stream could widen unstably. Other constraints would be required to stabilize the width. Possible factors could be bed morphology beneath ridges that does not allow fast motion even in thawed conditions, or inward advection of cold ice from the ridges across the margin and into the ice stream, which suppresses the shielding effect. The unknown geothermal heat flow beneath ice streams and inter ice-stream ridges is a major uncertainty in doing these calculations.
Infrared triggered dwell and active cooling thermal control effects on microstructural uniformity in DED
Directed Energy Deposition (DED) offers rapid large scale fabrication, but difficulty in delivering consistent microstructures and properties hinders the use of DED fabricated components in safety or performance critical applications. Variability stems from the complex thermal cycles generated by the toolpath used to print the required geometry. Several practical methods have become established in DED to regulate overheating, such as active cooling of the baseplate structure or the use of an infrared camera to inject interlayer pauses to ensure the top layer of the component cools to a set temperature, which have been shown to affect microstructure. However, no critical assessment has been performed as to how effective these controls are in promoting microstructural uniformity in the context of complex layer timing commonly generated by non-prismatic geometries. Here we show how controls influence the thermal field, phase transformations, and dynamic annealing of a low-temperature transformation steel using infrared imaging and operando neutron diffraction. Counterintuitively, common thermal homogenization process controls can reduce microstructural uniformity because these approaches stabilize peak temperature while overlooking temperatures near the solid-state phase transformation fronts. Instead, the cyclic reheating induces spatially-variant dynamically annealed regions which can be modulated via control parameters. We show that these controls have spatially linked effects centimeters away from the active weld, which implies that microstructure control must co-optimize thermal input across many subsequent layers. In conclusion, our results demonstrate the pressing need for higher order controls that integrate predictive elements of simulation data to stabilize printed properties for future qualification of DED components.
Advanced Thermal Control Technologies for Mars Rovers and Landers
Explore the source record for details and available documents.
Infrared Detector System with Controlled Thermal Conductance
A thermal infrared detector system includes a heat sink, a support member, a connection support member connecting the support member to the heat sink and including a heater unit is reviewed. An infrared detector element is mounted on the support member and a temperature signal representative of the infrared energy contacting the support member can then be derived by comparing the temperature of the support member and the heat sink. The temperature signal from a support member and a temperature signal from the connection support member can then be used to drive a heater unit mounted on the connection support member to thereby control the thermal conductance of the support member. Thus, the thermal conductance can be controlled so that it can be actively increased or decreased as desired.
Designing a Propylene-Glycol Coolant Servicer System for Gateway’s Internal Active Thermal Control System
A human spacecraft ATCS—especially one using single-phase coolant loops exposed to cabin atmospheric conditions—requires periodic degassing and refilling to support long-duration missions of 15 to 30 years. During initial fill operations, system maintenance, gas permeation, and quick-disconnect mating or de-mating, small amounts of gas can gradually enter the coolant system over time. This can lead to degraded heat transfer performance, pump cavitation, and potentially pump vapor lock if a significant gas volume accumulates over time. Additionally, system leaks and routine fluid sampling can gradually reduce accumulator volumes to unacceptable levels, requiring periodic refills. In more severe cases, catastrophic changes in fluid composition may necessitate emergency draining, refilling, and degassing to ensure continued system functionality. These risks were identified and mitigated on the ISS ITCS through the development of a dual-membrane degasser ORU and a Fluid Servicer System ORU for coolant refilling. These systems were developed for the fully water-based ISS ITCS Coolant[1]. The Gateway space station, the first permanent human habitat in lunar orbit, uses a propylene-glycol/water coolant mixture, which has significantly different fluid properties compared to pure water. Because microgravity degassing technologies are sensitive to fluid surface tension and viscosity, existing ISS hardware is not suitable for servicing a propylene-glycol-based TCS. Unlike the ISS, the Gateway will operate in a higher-radiation environment and must meet stricter mass constraints due to its location outside of low earth orbit. This Government Furnished Equipment (GFE) flight hardware project aims to develop a lightweight, radiation-resistant Coolant Servicer System (CSS) capable of degassing and refilling Gateway’s propylene-glycol water-based IATCS.
Designing a Propylene-Glycol Coolant Servicer System for Gateway’s Internal Active Thermal Control System
A human spacecraft ATCS—especially one using single-phase coolant loops exposed to cabin atmospheric conditions—requires periodic degassing and refilling to support long-duration missions of 15 to 30 years. During initial fill operations, system maintenance, gas permeation, and quick-disconnect mating or de-mating, small amounts of gas can gradually enter the coolant system over time. This can lead to degraded heat transfer performance, pump cavitation, and potentially pump vapor lock if a significant gas volume accumulates over time. Additionally, system leaks and routine fluid sampling can gradually reduce accumulator volumes to unacceptable levels, requiring periodic refills. In more severe cases, catastrophic changes in fluid composition may necessitate emergency draining, refilling, and degassing to ensure continued system functionality. These risks were identified and mitigated on the ISS ITCS through the development of a dual-membrane degasser ORU and a Fluid Servicer System ORU for coolant refilling. These systems were developed for the fully water-based ISS ITCS Coolant[1]. The Gateway space station, the first permanent human habitat in lunar orbit, uses a propylene-glycol/water coolant mixture, which has significantly different fluid properties compared to pure water. Because microgravity degassing technologies are sensitive to fluid surface tension and viscosity, existing ISS hardware is not suitable for servicing a propylene-glycol-based TCS. Unlike the ISS, the Gateway will operate in a higher-radiation environment and must meet stricter mass constraints due to its location outside of low earth orbit. This Government Furnished Equipment (GFE) flight hardware project aims to develop a lightweight, radiation-resistant Coolant Servicer System (CSS) capable of degassing and refilling Gateway’s propylene-glycol water-based IATCS.
Shuttle active thermal control system development testing. Volume 3: Modular radiator system test data correlation with thermal model
Results are presented of an analysis which compares the performance predictions of a thermal model of a multi-panel modular radiator system with thermal vacuum test data. Comparisons between measured and predicted individual panel outlet temperatures and pressure drops and system outlet temperatures have been made over the full range of heat loads, environments and plumbing arrangements expected for the shuttle radiators. Both two sided and one sided radiation have been included. The model predictions show excellent agreement with the test data for the maximum design conditions of high load and hot environment. Predictions under minimum design conditions of low load-cold environments indicate good agreement with the measured data, but evaluation of low load predictions should consider the possibility of parallel flow instabilities due to main system freezing. Performance predictions under intermediate conditions in which the majority of the flow is not in either the main or prime system are adequate although model improvements in this area may be desired. The primary modeling objective of providing an analytical technique for performance predictions of a multi-panel radiator system under the design conditions has been met.
Development of a thermal control architecture for the Mars Exploration Rovers
This paper discusses the design philosophies and system requirements that resulted in a successful Mars rover thermal design.
Thermal control of small spacecraft using single and two-phase fluid loops
Explore the source record for details and available documents.
Thermal control of small spacecraft using single and two-phase fluid loops
Explore the source record for details and available documents.
Advanced Thermal Control Technologies for Future Space Science Missions at JPL
Explore the source record for details and available documents.