Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Target tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Expandable Log Analyzing Framework

Prior to my internship, I was informed that a previous intern had built a tool to analyse MongoDB logs and look for invalid access attempts, which served as a great reference point for my project. I was initially tasked with expanding on her prototype and filling in the gaps such as integrating it with the main monitoring tool the lab uses. Eventually, the scope grew, expanding to support other databases and a growing collection of tools. I organized the framework around an observer pattern, meaning one point in the program sending updates to the rest of the framework. Every time a log was read and parsed, it was sent to be processed by the tools, using the type of event as a means to determine which tools should get a chance to act on the log. This decouples the tools from the log reader, making future updates and additions much easier. The framework processes MongoDB logs at ~135,000 entries per second and PostgreSQL logs at ~170,500 entries per second, accurately detecting anomalies such as slow queries and connections from unknown addresses. This framework serves to fill gaps in database monitoring tools currently implemented at the lab, such as tracking failed authentication for PostgreSQL and MongoDB which had very minimal or none before this framework. National labs such as Fermilab hold sensitive data and valuable computing resources, making them attractive targets. Monitoring intrusion attempts on databases is made much easier by this comprehensive monitoring suite.

Clark, Dylan [Unlisted, IL]↗

Expandable Log Analyzing Framework

Prior to my internship, I was informed that a previous intern had built a tool to analyse MongoDB logs and look for invalid access attempts, which served as a great reference point for my project. I was initially tasked with expanding on her prototype and filling in the gaps such as integrating it with the main monitoring tool the lab uses. Eventually, the scope grew, expanding to support other databases and a growing collection of tools. I organized the framework around an observer pattern, meaning one point in the program sending updates to the rest of the framework. Every time a log was read and parsed, it was sent to be processed by the tools, using the type of event as a means to determine which tools should get a chance to act on the log. This decouples the tools from the log reader, making future updates and additions much easier. The framework processes MongoDB logs at ~135,000 entries per second and PostgreSQL logs at ~170,500 entries per second, accurately detecting anomalies such as slow queries and connections from unknown addresses. This framework serves to fill gaps in database monitoring tools currently implemented at the lab, such as tracking failed authentication for PostgreSQL and MongoDB which had very minimal or none before this framework. National labs such as Fermilab hold sensitive data and valuable computing resources, making them attractive targets. Monitoring intrusion attempts on databases is made much easier by this comprehensive monitoring suite.

Clark, Dylan [Unlisted, IL]↗

Database-Agnostic Log Analysis and Monitoring Framework

Prior to my internship, I was informed that a previous intern had built a tool to analyse MongoDB logs and look for invalid access attempts, which served as a great reference point for my project. I was initially tasked with expanding on her prototype and filling in the gaps such as integrating it with the main monitoring tool the lab uses. Eventually, the scope grew, expanding to support other databases and a growing collection of tools. I organized the framework around an observer pattern, meaning one point in the program sending updates to the rest of the framework. Every time a log was read and parsed, it was sent to be processed by the tools, using the type of event as a means to determine which tools should get a chance to act on the log. This decouples the tools from the log reader, making future updates and additions much easier. The framework processes MongoDB logs at ~135,000 entries per second and PostgreSQL logs at ~170,500 entries per second, accurately detecting anomalies such as slow queries and connections from unknown addresses. This framework serves to fill gaps in database monitoring tools currently implemented at the lab, such as tracking failed authentication for PostgreSQL and MongoDB which had very minimal or none before this framework. National labs such as Fermilab hold sensitive data and valuable computing resources, making them attractive targets. Monitoring intrusion attempts on databases is made much easier by this comprehensive monitoring suite.

Clark, Dylan [Unlisted, US, IL; Fermilab]↗

Multi-Differential Semi-Inclusive Charged-Current Muon Neutrino Cross Sections on Helium-4 in MINERvA and the Helium-to-CH Target Cross Section Ratio

A comprehensive international effort has been underway to elucidate the properties and behaviors of neutrinos. A major source of systematic uncertainties in studying neutrino-induced interactions comes from neutrino-nucleus cross-section models, highlighting the need for more precise statistical measurements. MINERvA, an on-axis neutrino-nucleus scattering experiment located at the Fermi National Accelerator Laboratory, was established to produce neutrino cross-section measurements with many different nuclei. The helium target is the lightest nucleus to be measured by MINERvA. Using the NuMI medium energy muon neutrino data set, we present preliminary results and summarize the extraction of the charged current (CC) muon neutrino - helium-4 semi-inclusive ($\nu_{\mu}$+$^{4}\textrm{He}$$\rightarrow$$\mu^{-}$+N$\pi$+M$\textit{p}$) multi-differential cross-section extraction as a function of transverse ($P_{T}$) and longitudinal ($P_{L}$) muon momentum with respect to the neutrino beamline. We define the final state topology as CC-N$\pi$M$\textit{p}$, with at least two reconstructed tracks: a muon and a combination of N protons and M pions, where $N + M > 0$. To probe the dependence on the size of the nucleus in neutrino-induced interaction phenomena we present a differential cross-section ratio of helium-4 to MINERvA's hydrocarbon target (\textrm{CH}) as a function of transverse muon momentum.

Nguyen, Christian↗

Vascular endothelial and smooth muscle cell galvanotactic response and differential migratory behavior

Chronic disease or injury of the vasculature impairs the functionality of vascular wall cells particularly in their ability to migrate and repair vascular surfaces. Under pathologic conditions, vascular endothelial cells (ECs) lose their non-thrombogenic properties and decrease their motility. Alternatively, vascular smooth muscle cells (SMCs) may increase motility and proliferation, leading to blood vessel luminal invasion. Current therapies to prevent subsequent blood vessel occlusion commonly mechanically injure vascular cells leading to endothelial denudation and smooth muscle cell luminal migration. Due to this dichotomous migratory behavior, a need exists for modulating vascular cell growth and migration in a more targeted manner. Here, we examine the efficacy of utilizing small direct current electric fields to influence vascular cell-specific migration (“galvanotaxis”). We designed, fabricated, and implemented an in vitro chamber for tracking vascular cell migration direction, distance, and displacement under galvanotactic influence of varying magnitude. Our results indicate that vascular ECs and SMCs have differing responses to galvanotaxis; ECs exhibit a positive correlation of anodal migration while SMCs exhibit minimal change in directional migration in relation to the electric field direction. SMCs exhibit less motility response (i.e. distance traveled in 4 h) compared to ECs, but SMCs show a significantly higher motility at low electric potentials (80 mV/cm). With further investigation and translation, galvanotaxis may be an effective solution for modulation of vascular cell-specific migration, leading to enhanced endothelialization, with coordinate reduced smooth muscle in-migration.

60 APPLIED LIFE SCIENCES↗

A heterodyne interferometer for angle metrology

We have developed a compact, high-resolution, angle measurement instrument based on a heterodyne interferometer. Common-path heterodyne interferometer metrology is used to measure displacements of a reflective target surface. In the interferometer set up, an optical mask is used to sample the laser beam reflecting back from four areas on a target surface. From the relative displacement measurements of the target surface areas, we can simultaneously determine angular rotations around two orthogonal axes in a plane perpendicular to the measurement beam propagation direction. The device is used in a testbed for a tracking telescope system where pitch and yaw angle measurements of a flat mirror are performed. Angle noise measurement of the device shows 0.1 nrad/{radical}(Hz) at 1 Hz, at a working distance of 1 m. The operation range and nonlinearity of the device when used with a flat mirror is approximately {+-}0.15 mrad, and 3 {mu}rad rms, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-70: Feasibility Study of Dynamic Arc and IMRT Treatment Plans Utilizing Vero Treatment Unit and IPlan Planning Computer for SRS/FSRT Brain Cancer Patients

Purpose: To investigate the feasibility of utilizing Dynamic Arc (DA) and IMRT with 5mm MLC leaf of VERO treatment unit for SRS/FSRT brain cancer patients with non-invasive stereotactic treatments. The DA and IMRT plans using the VERO unit (BrainLab Inc, USA) are compared with cone-based planning and proton plans to evaluate their dosimetric advantages. Methods: The Vero treatment has unique features like no rotational or translational movements of the table during treatments, Dynamic Arc/IMRT, tracking of IR markers, limitation of Ring rotation. Accuracies of the image fusions using CBCT, orthogonal x-rays, and CT are evaluated less than ∼ 0.7mm with a custom-made target phantom with 18 hidden targets. 1mm margin is given to GTV to determine PTV for planning constraints considering all the uncertainties of planning computer and mechanical uncertainties of the treatment unit. Also, double-scattering proton plans with 6F to 9F beams and typical clinical parameters, multiple isocenter plans with 6 to 21 isocenters, and DA/IMRT plans are evaluated to investigate the dosimetric advantages of the DA/IMRT for complex shape of targets. Results: 3 Groups of the patients are divided: (1) Group A (complex target shape), CI's are same for IMRT, and DGI of the proton plan are better by 9.5% than that of the IMRT, (2) Group B, CI of the DA plans (1.91+/−0.4) are better than cone-based plan, while DGI of the DA plan is 4.60+/−1.1 is better than cone-based plan (5.32+/−1.4), (3) Group C (small spherical targets), CI of the DA and cone-based plans are almost the same. Conclusion: For small spherical targets, cone-based plans are superior to other 2 plans: DS proton and DA plans. For complex or irregular plans, dynamic and IMRT plans are comparable to cone-based and proton plans for complex targets.

60 APPLIED LIFE SCIENCES↗

CFD Validation of Gas Injection in Flowing Mercury over Vertical Smooth and Grooved Wall

The Spallation Neutron Source (SNS) is an accelerator-based neutron source at Oak Ridge National Laboratory (ORNL).The nuclear spallation reaction occurs when a proton beam hits liquid mercury. This interaction causes thermal expansion of the liquid mercury which produces high pressure waves. When these pressure waves hit the target vessel wall, cavitation can occur and erode the wall. Research and development efforts at SNS include creation of a vertical protective gas layer between the flowing liquid mercury and target vessel wall to mitigate the cavitation damage erosion and extend the life time of the target. Since mercury is opaque, computational fluid dynamics (CFD) can be used as a diagnostic tool to see inside the liquid mercury and guide the experimental efforts. In this study, CFD simulations of three dimensional, unsteady, turbulent, two-phase flow of helium gas injection in flowing liquid mercury over smooth, vertically grooved and horizontally grooved walls are carried out with the commercially available CFD code Fluent-12 from ANSYS. The Volume of Fluid (VOF) model is used to track the helium-mercury interface. V-shaped vertical and horizontal grooves with 0.5 mm pitch and about 0.7 mm depth were machined in the transparent wall of acrylic test sections. Flow visualization data of helium gas coverage through transparent test sections is obtained with a high-speed camera at the ORNL target test facility (TTF). The helium gas mass flow rate is 8 mg/min and introduced through a 0.5 mm diameter port. The local mercury velocity is 0.9 m/s. In this paper, the helium gas flow rate and the local mercury velocity are kept constant for the three cases. Time integration of predicted helium gas volume fraction over time is done to evaluate the gas coverage and calculate the average thickness of the helium gas layer. The predicted time-integrated gas coverage over vertically grooved and horizontally grooved test sections is better than over a smooth wall. The simulations show that the helium gas is trapped inside the grooves. The predicted time-averaged gas coverage is in good qualitative agreement with the measured gas coverage.

43 PARTICLE ACCELERATORS↗

Investigation of Proton Beam-Driven Fusion Reactions Generated by an Ultra-Short Petawatt-Scale Laser Pulse

We present results from a pitcher-catcher experiment utilizing a proton beam generated with nanostructured targets at a petawatt-class, short-pulse laser facility to induce proton-boron fusion reactions in a secondary target. A 45-fs laser pulse with either 400 nm wavelength and 7 J energy, or 800 nm and 14 J, and an intensity of up to 5 × 10 21 W/cm 2 was used to irradiate either thin foil targets or near-solid density, nanostructured targets made of boron nitride (BN) nanotubes. In particular, for 800 nm wavelength irradiation, a BN nanotube target created a proton beam with about five times higher maximum energy and about ten times more protons than a foil target. This proton beam was used to irradiate a thick plate made of boron nitride placed in close proximity to trigger 11 B (p, α) 2α fusion reactions. A suite of diagnostics consisting of Thomson parabola ion spectrometers, postshot nuclear activation measurements, neutron time-of-flight detectors, and differentially filtered solid-state nuclear track detectors were used to measure both the primary proton spectrum and the fusion products. From the primary proton spectrum, we calculated (p, n) and (α,n) reactions in the catcher and compare with our measurements. The nuclear activation results agree quantitatively and neutron signals agree qualitatively with the calculations, giving confidence that primary particle distributions can be obtained from such measurements. These results provide new insights for measuring the ion distributions inside of proton-boron fusion targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

4D tumor centroid tracking using orthogonal 2D dynamic MRI: Implications for radiotherapy planning

Purpose: Current pretreatment, 4D imaging techniques are suboptimal in that they sample breathing motion over a very limited “snapshot” in time. Heretofore, long-duration, 4D motion characterization for radiotherapy planning, margin optimization, and validation have been impractical for safety reasons, requiring invasive markers imaged under x-ray fluoroscopy. To characterize 3D tumor motion and associated variability over durations more consistent with treatments, the authors have developed a practical dynamic MRI (dMRI) technique employing two orthogonal planes acquired in a continuous, interleaved fashion.Methods: 2D balanced steady-state free precession MRI was acquired continuously over 9–14 min at approximately 4 Hz in three healthy volunteers using a commercial 1.5 T system; alternating orthogonal imaging planes (sagittal, coronal, sagittal, etc.) were employed. The 2D in-plane pixel resolution was 2 × 2 mm{sup 2} with a 5 mm slice profile. Simultaneous with image acquisition, the authors monitored a 1D surrogate respiratory signal using a device available with the MRI system. 2D template matching-based anatomic feature registration, or tracking, was performed independently in each orientation. 4D feature tracking at the raw frame rate was derived using spline interpolation.Results: Tracking vascular features in the lung for two volunteers and pancreatic features in one volunteer, the authors have successfully demonstrated this method. Registration error, defined here as the difference between the sagittal and coronal tracking result in the SI direction, ranged from 0.7 to 1.6 mm (1σ) which was less than the acquired image resolution. Although the healthy volunteers were instructed to relax and breathe normally, significantly variable respiration was observed. To demonstrate potential applications of this technique, the authors subsequently explored the intrafraction stability of hypothetical tumoral internal target volumes and 3D spatial probability distribution functions. The surrogate respiratory information allowed the authors to show how this technique can be used to study correlations between internal and external (surrogate) information over these prolonged durations. However, compared against the gold standard of the time stamps in the dMRI frames, the temporal synchronization of the surrogate 1D respiratory information was shown to be likely unreliable.Conclusions: The authors have established viability of a novel and practical pretreatment, 4D tumor centroid tracking method employing a commercially available dynamic MRI sequence. Further developments from the vendor are likely needed to provide a reliably synchronized surrogate 1D respiratory signal, which will likely broaden the utility of this method in the pretreatment radiotherapy planning context.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Activity-targeted metaproteomics uncovers rare syntrophic bacteria central to anaerobic community metabolism

Syntrophic microbial consortia can contribute significantly to the activity and function of anoxic ecosystems, yet are often too rare to study their in situ physiologies using traditional molecular methods. Here, in this study, we describe a technical innovation combining bioorthogonal non-canonical amino acid tagging (BONCAT), stable isotope probing, and metaproteomics to improve the recovery of proteins from active community members and track isotope incorporation. Both click chemistry-enabled cell-sorting and direct protein pulldown coupled to metaproteomics improved recovery of isotopically labeled proteins during acetate oxidation within a full-scale anaerobic digester. Resulting labeled protein expression profiles revealed elevated activity of a rare and uncharacterized syntrophic bacterium belonging to the family Natronincolaceae. BONCAT-based capture of newly translated proteins provided direct molecular evidence for the expression of a previously hypothesized oxidative glycine pathway for syntrophic acetate oxidation by this microorganism, showcasing the potential of targeted metaproteomics to characterize rare and active cells central to community metabolism in natural and engineered ecosystems.

Friedline, Skyler [Univ. of British Columbia, Vanc↗

Primary yields of protons measured using CR-39 in laser-induced deuteron–deuteron fusion reactions

The deuteron and deuteron (DD) fusion reactions is the most crucial reaction in the nuclear astrophysics and inertial confinement fusion, which is responsible for synthesizing chemical elements, and for powering the stellar evolution. The plasma environment generated by the high-intensity laser used in a DD fusion reaction is similar to the early stage of the Big Bang. Therefore, it is important to study laser-induced DD fusion reactions. Recently, we experimentally investigated such reactions using eight laser beams with the third harmonic impact on a deuterated polyethylene target at the ShenGuang-II Upgrade facility. In this work, we focused on the application of range-filter spectrometers assembled from a 70 μm aluminum filter and two CR-39 nuclear track detectors to measure the yields of primary DD protons. Based on the track diameter calibration results of 3 MeV protons used to diagnose the tracks on the range- filter spectrometers, we measured a primary DD proton yield of approximately (8:52 ± 1:7) × 10 6 , consistent with the yields from similar laser facilities worldwide, indicating that range-filter spectrometry is an effective way to measure primary DD protons. Furthermore, using other accurate detectors may help to measure the rare events of D 3 He protons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Drift Chamber for the Experiment to Study the Nature of the Confinement

The GlueX experiment was designed to search for hybrid mesons with exotic quantum numbers using a beam of linearly polarized photons incident on a liquid hydrogen target. The spectrum of these states and their mass splitting from normal mesons may yield information on confinement. The description of the GlueX spectrometer and Forward Drift Chambers (FDC) as a part of track reconstruction system is presented in the text. FDC‘s are multiwire chambers with cathode and anode read-out. The system allows reconstructing tracks of charged particles with ~200mkm accuracy with angles from 20° up to 1°. One of the detector features is 1.64% X 0 material amount in the active area. The cathode gain calibration procedure is presented. The results of such calibration using cosmic data and beam data are presented as well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy-Optimal Vehicle Longitudinal Motion Control via Pontryagin’s Minimum Principle and Ultra-Local Model

Longitudinal vehicle motion control is essential for enhancing performance and optimizing a vehicle’s energy usage. However, it remains a challenging task due to the nonlinear and uncertain nature of vehicle dynamics, along with varying driving conditions. This paper presents a novel ultra-local optimal control approach based on Pontryagin’s Minimum Principle (PMP) that circumvents the need for detailed system identification by employing an ultra-local model. The control objective is to minimize the total energy consumption under boundary conditions while ensuring smooth traction force generation. The proposed approach is evaluated using a high-fidelity vehicle model in three representative scenarios: (i) nominal driving, (ii) a change in tire road friction coefficient (TRFC) from 0.5 to 0.65 and road slope from 0% to 5% during the maneuver, with target velocity unchanged, and (iii) a change in target velocity from 20 m/s to 0 m/s during the maneuver, while maintaining nominal TRFC and slope conditions. The simulation results demonstrate that the proposed method delivers robust performance, effectively balancing consumption and tracking accuracy in all tested scenarios.

Waleed khan, Muhammad [The University of Texas at ↗

A clip-based protocol for breast boost radiotherapy provides clear target visualisation and demonstrates significant volume reduction over time

The clinical target volume (CTV) for early stage breast cancer is difficult to clearly identify on planning computed tomography (CT) scans. Surgical clips inserted around the tumour bed should help to identify the CTV, particularly if the seroma has been reabsorbed, and enable tracking of CTV changes over time. A surgical clip-based CTV delineation protocol was introduced. CTV visibility and its post-operative shrinkage pattern were assessed. The subjects were 27 early stage breast cancer patients receiving post-operative radiotherapy alone and 15 receiving post-operative chemotherapy followed by radiotherapy. The radiotherapy alone (RT/alone) group received a CT scan at median 25 days post-operatively (CT1rt) and another at 40 Gy, median 68 days (CT2rt). The chemotherapy/RT group (chemo/RT) received a CT scan at median 18 days post-operatively (CT1ch), a planning CT scan at median 126 days (CT2ch), and another at 40 Gy (CT3ch). There was no significant difference (P = 0.08) between the initial mean CTV for each cohort. The RT/alone cohort showed significant CTV volume reduction of 38.4% (P = 0.01) at 40 Gy. The Chemo/RT cohort had significantly reduced volumes between CT1ch: median 54 cm{sup 3} (4–118) and CT2ch: median 16 cm{sup 3}, (2–99), (P = 0.01), but no significant volume reduction thereafter. Surgical clips enable localisation of the post-surgical seroma for radiotherapy targeting. Most seroma shrinkage occurs early, enabling CT treatment planning to take place at 7 weeks, which is within the 9 weeks recommended to limit disease recurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of a pretreatment delivery quality assurance method for the CyberKnife Synchrony system

Purpose: To evaluate the geometric and dosimetric accuracies of the CyberKnife Synchrony respiratory tracking system (RTS) and to validate a method for pretreatment patient-specific delivery quality assurance (DQA). Methods: An EasyCube phantom was mounted on the ExacTrac gating phantom, which can move along the superior–inferior (SI) axis of a patient to simulate a moving target. The authors compared dynamic and static measurements. For each case, a Gafchromic EBT3 film was positioned between two slabs of the EasyCube, while a PinPoint ionization chamber was placed in the appropriate space. There were three steps to their evaluation: (1) the field size, the penumbra, and the symmetry of six secondary collimators were measured along the two main orthogonal axes. Dynamic measurements with deliberately simulated errors were also taken. (2) The delivered dose distributions (from step 1) were compared with the planned ones, using the gamma analysis method. The local gamma passing rates were evaluated using three acceptance criteria: 3% local dose difference (LDD)/3 mm, 2%LDD/2 mm, and 3%LDD/1 mm. (3) The DQA plans for six clinical patients were irradiated in different dynamic conditions, to give a total of 19 cases. The measured and planned dose distributions were evaluated with the same gamma-index criteria used in step 2 and the measured chamber doses were compared with the planned mean doses in the sensitive volume of the chamber. Results: (1) A very slight enlargement of the field size and of the penumbra was observed in the SI direction (on average <1 mm), in line with the overall average CyberKnife system error for tracking treatments. (2) Comparison between the planned and the correctly delivered dose distributions confirmed the dosimetric accuracy of the RTS for simple plans. The multicriteria gamma analysis was able to detect the simulated errors, proving the robustness of their method of analysis. (3) All of the DQA clinical plans passed the tests, both in static and dynamic conditions. No statistically significant differences were found between static and dynamic cases, confirming the high degree of accuracy of the Synchrony RTS. Conclusions: The presented methods and measurements verified the mechanical and dosimetric accuracy of the Synchrony RTS. Their method confirms the fact that the RTS, if used properly, is able to treat a moving target with great precision. By combining PinPoint ion chamber, EBT3 films, and gamma evaluation of dose distributions, their DQA method robustly validated the effectiveness of CyberKnife and Synchrony system.

60 APPLIED LIFE SCIENCES↗

CT-Guided Interventions Using a Free-Hand, Optical Tracking System: Initial Clinical Experience

PurposeThe present study was designed to evaluate the geometrical accuracy and clinical applicability of a new, free-hand, CT-guided, optical navigation system.MethodsFifteen procedures in 14 consecutive patients were retrospectively analyzed. The navigation system was applied for interventional procedures on small target lesions, in cases with long needle paths, narrow access windows, or when an out-of-plane access was expected. Mean lesion volume was 27.9 ml, and mean distance to target measured was 107.5 mm. Eleven of 15 needle trajectories were planned as out-of-plane approaches regarding the axial CT plane.ResultsNinety-one percent of the biopsies were diagnostic. All therapeutic interventions were technically successful. Targeting precision was high with a mean distance of the needle tip from planned target of 1.98 mm. Mean intervention time was 1:12 h. A statistically significant correlation between angular needle deviation and intervention time (p = 0.007), respiratory movement of the target (p = 0.008), and body mass index (p = 0.02) was detected. None of the evaluated parameters correlated significantly with the distance from the needle tip to the planned target.ConclusionsThe application of a navigation system for complex CT-guided procedures provided safe and effective targeting within a reasonable intervention time in our series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SYS-5620-Project - Achieving Robust Laser Performance utilizing Historical Shot Experiments - A Systems Engineering Proposal

The National Ignition Facility (NIF) at Lawrence Livermore National Laboratory precisely guides, amplifies, reflects, and focuses 192 powerful laser beams into a target about the size of a pencil eraser in a few billionths of a second, delivering more than 2 million joules of ultraviolet energy and 500 trillion watts of peak power. A crucial goal of the system is to trigger precise implosions of fuel capsules. This is achieved by delivering all 192 beams at user-specified times and locations on the target, minimizing any deviation from the requested performance. Power requirements can vary substantially on each experiment and the facility supports numerous amplifier pumping configurations and their attendant nonlinear effects. To achieve the tight performance required across such a broad array of configurations, constant comparison of measured and requested power delivery are tracked and long-term trends analyzed as a guide to understanding future performance. A very common question asked is given the current state of the laser today – how well would a similar experiment from the past perform today? Additionally, if one were to specify an alternate amplifier configuration using today’s model would and damage limits be exceeded and would there be an increase in performance. The physics model used to make these predictions and equipment protection checks is called the Virtual Beamline (VBL). VBL is used with an incoming desired pulse shape and energy to be delivered on target, and then does an iterative solve to predict the needed injected pulse in the front-end of the system to achieve this result. To effectively guide and predict future NIF experiment performance, laser scientists explore current amplifier configurations and compare them with historical data utilizing a tool called the Reverify Toolbox.

42 ENGINEERING↗