Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Switched systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Electronic and Geometric effects on Photochemistry of Molecules in Well-Defined Environments

Assemblies of molecular switches at surfaces are of great interest for applications in solar energy conversion, optoelectronic and optomechanical devices. Experimental studies have demonstrated that it is possible to optically probe photoactive molecules in well-defined nanoscale environments. To understand these systems, we have developed a polarizable frozen-density embedding (FDEpol) to model the optical properties of molecules adsorbed on metal clusters. We have demonstrated that the FDEpol method can describe the ground state and linear response properties of strongly coupled systems with results that are in good agreement with exact projection based embedding method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Opdefender Network Monitoring And Control System

OpDefender is a new system designed to enhance the cyber security of control system networks. It accomplishes this by inspecting each network packet using a novel, patent-pending method that extends software defined networking into the application/ICS protocol layer. OpDefender consists of two key components: 1. Smart, “ICS-aware” network switches that analyze and filter network traffic in real time. 2. A network management human machine interface (HMI) that allows an operator to monitor and control network traffic in real time. The “ICS-aware” switches can serve as a drop-in replacement for typical network switches, or they can be used in conjunction with existing network switches. OpDefender is configured and controlled in real time via a custom-built, web-based HMI designed with the operator in mind.

Johnson, BriamE.↗

Perturbative diffraction methods resolve a conformational switch that facilitates a two-step enzymatic mechanism

Enzymes catalyze biochemical reactions through precise positioning of substrates, cofactors, and amino acids to modulate the transition-state free energy. However, the role of conformational dynamics remains poorly understood due to poor experimental access. This shortcoming is evident with Escherichia coli dihydrofolate reductase (DHFR), a model system for the role of protein dynamics in catalysis, for which it is unknown how the enzyme regulates the different active site environments required to facilitate proton and hydride transfer. Here, we describe ligand-, temperature-, and electric-field-based perturbations during X-ray diffraction experiments to map the conformational dynamics of the Michaelis complex of DHFR. We resolve coupled global and local motions and find that these motions are engaged by the protonated substrate to promote efficient catalysis. This result suggests a fundamental design principle for multistep enzymes in which pre-existing dynamics enable intermediates to drive rapid electrostatic reorganization to facilitate subsequent chemical steps.

59 BASIC BIOLOGICAL SCIENCES↗

Resilient Distribution System Restoration with Equitable Load Shedding

A methodology is proposed for the improvement of electric distribution system resilience to high-impact, low-probability catastrophic events. An approach for dynamic network reconfiguration and coordination of distributed energy resources is introduced to assist in restoration efforts. The problem is formulated as a mixed-integer linear program that minimizes generation costs, the cost of lost load, and costs associated with equitable load shedding, while respecting operational limits of generation, loads, and the network. Constraints are imposed on binary switching variables to ensure equitable load shedding in emergency situations. Numerical validation of the proposed approach is conducted on an example distribution feeder, and case studies are performed to analyze the impact of various parameters in the optimization problem formulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optomechanical interaction in fibre lasers with micro-optomechanical resonance structures

We report the results of studies of fibre lasers with passive modulators based on light-excited micro-optomechanical resonance structures (micro-oscillators). It is shown that in fibre lasers based on active fibres doped with rare-earth elements (Er, Er/Yb, Yb, Nd), the optomechanical interaction of laser radiation with micro-oscillators of various types (fibre-optic, microvolume) leads to self-oscillations of the characteristics of laser radiation at frequencies of relaxation oscillations and intermode beats synchronised with the frequencies of elastic eigenoscillations of micro-oscillators. It is found that in an ultra-long erbium – ytterbium fibre laser with a nonlinear mirror based on a microcantilever, laser photothermal excitation of the second mode of elastic transverse oscillations of the microcantilever makes it possible to perform passive mode locking exclusively due to Q-switching of the laser cavity. Pulsed lasing with a controlled repetition rate (∼76 kHz), a pulse duration of 2 – 5 μs and an output energy of 0.1 μJ per pulse is implemented. Based on a simplified physical model of the indicated fibre lasers with micro-oscillators, we have developed an approximate mathematical model describing the regimes of passive mode locking of fibre lasers with micro-oscillators that play the role of mirrors with a nonlinear reflection coefficient in the laser cavity. The prospects for the development and application of the considered laser systems are discussed. (control of laser radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cloud-based implementation of white-box model predictive control for a GEOTABS office building: A field test demonstration

Model predictive control (MPC) has been proven in simulations and pilot case studies to be a superior control strategy for large buildings. MPC can utilize the weather and occupancy schedule forecasts, together with the system model, to predict the future thermal behavior of the building and minimize the overall energy use and maximize thermal comfort. However, these advantages come with the cost of increased modeling effort, computational demands, communication infrastructure, and commissioning efforts. Thus a typical approach is to, often rapidly, simplify the building modeling and MPC optimization problem while paying a price of not reaching the full performance potential. It has been shown that by employing accurate physics-based models, MPC performance can be notably increased closer to its theoretical performance bound. However, implementation of such high-fidelity MPC in real buildings remains a challenge, resulting in a lack of successful field test studies. This work presents the methodology and field test demonstration of a computationally efficient implementation of the white-box MPC in an office building in Belgium. The detailed model of the building is based on first-principle physical equations. The deployment and supervision of MPC operation in a practical setting are supported by an automated cloud-based communication infrastructure. The motivating factor behind the cloud-based architecture is its compatibility with a commercially appealing control as a service concept. The building is equipped with a ground source heat pump (GSHP) and thermally activated building structures (TABS), where the combination of both is also known as GEOTABS. From a control perspective, GEOTABS buildings are particularly challenging systems due to large scale, complex heating, ventilation and air conditioning (HVAC) system, and slow dynamics with time delays. On the other hand, there is an increased potential for energy savings due to the high thermal mass, which acts as thermal storage. The MPC operation is demonstrated during the challenging transient seasons (switching between heating and cooling), and its performance is compared to a traditional rule-based controller (RBC). We provide a proof of concept of real MPC operation for the most difficult seasons with notable GSHP energy use savings equal to 53.5% and thermal comfort improvement by 36.9%. Other MPC applications found in the literature describe tests for only cooling or only heating, and up to now only for a black-box or a grey-box approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grid Forming Fast Frequency Response for PMSG-Based Wind Turbines

Electric power systems are undergoing a rapid transition from fuel-based generation using synchronous generators to renewable generation interfaced by power electronics. In this context, a key challenge is using renewable generation with limited controllability to contribute to power system stability. In this work, we investigate grid-forming control of permanent magnet synchronous generator (PMSG) wind turbines. The proposed control and curtailment strategy supports the entire spectrum of standard functions of grid-following (e.g. maximum power point tracking (MPPT) and grid-forming control (e.g., primary frequency control) without explicit mode switching. A detailed case study is used to compare the performance of the proposed control at operating points corresponding to MPPT and frequency control with standard grid-forming and grid-following controls. Further, the results demonstrate that (i) the proposed energy balancing grid forming control is self-synchronizing in MPPT mode, (ii) the (limited) energy storage and controllability of wind turbines can be adequately utilized to provide grid support, and (ii) the proposed control exhibits good performance under variable wind speeds and does not result in a significant increase of wind turbine fatigue loads.

17 WIND ENERGY↗

Efficient Reformulation and Optimization for SC-ACOPF with Line Switching

This project aims to develop efficient and robust computational methods for solving the security-constrained alternating current optimal power flow problem (SC-ACOPF). The SC-ACOPF problem is a central problem in operating the electric power grids in the United States. It determines the most economically efficient way to operate the generation and transmission system to meet daily electricity demand. The solution found by solving an SC-ACOPF problem must satisfy the physics of the alternating current (AC) power flows, various generator and network operational constraints, and must maintain secure operation under various contingency scenarios, where a generator, a transmission branch, or a transformer may unexpectedly trip offline.

97 MATHEMATICS AND COMPUTING↗

Sensitivity-based voltage constraints for optimal power flow in low-voltage distribution feeders

The optimal power flow (OPF) problem for distribution systems can include network details down to the low-voltage (LV) points of interconnection of individual customers. This paper addresses the implementation of voltage magnitude constraints, and sets forth a practicable approach for capturing the effects on voltage from the switching behavior of loads (e.g., heat pumps, air conditioners, water heaters, or pool pumps) and from the variability of renewable generation (e.g., rooftop solar). The proposed method adjusts the OPF voltage constraints based on forecasts of load and generation upper and lower bounds, in conjunction with sensitivity factors derived from the power flow equations. An illustrative OPF formulation is also provided, which incorporates transformer models that include core loss. We demonstrate that accurate modeling of these LV network components is critical to avoid voltage violations at customer points of interconnection. Furthermore, the ideas are validated through numerical case studies on a realistic distribution feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Metaplastic and energy-efficient biocompatible graphene artificial synaptic transistors for enhanced accuracy neuromorphic computing

CMOS-based computing systems that employ the von Neumann architecture are relatively limited when it comes to parallel data storage and processing. In contrast, the human brain is a living computational signal processing unit that operates with extreme parallelism and energy efficiency. Although numerous neuromorphic electronic devices have emerged in the last decade, most of them are rigid or contain materials that are toxic to biological systems. In this work, we report on biocompatible bilayer graphene-based artificial synaptic transistors (BLAST) capable of mimicking synaptic behavior. The BLAST devices leverage a dry ion-selective membrane, enabling long-term potentiation, with ~50 aJ/µm 2 switching energy efficiency, at least an order of magnitude lower than previous reports on two-dimensional material-based artificial synapses. The devices show unique metaplasticity, a useful feature for generalizable deep neural networks, and we demonstrate that metaplastic BLASTs outperform ideal linear synapses in classic image classification tasks. With switching energy well below the 1 fJ energy estimated per biological synapse, the proposed devices are powerful candidates for bio-interfaced online learning, bridging the gap between artificial and biological neural networks.

97 MATHEMATICS AND COMPUTING↗

Secondary Frequency Control for Reconfigurable Interconnecting Microgrids

Microgrids and microgrid technologies offer an operations and control framework for realizing the needed aggregation of a growing share of distributed energy resources. As the number of microgrids increases, so will the incentive to interconnect them, leading to a combinatorial growth of potential operating states. At the same time, their growing complexity nudges interconnected microgrids conceptually closer to balancing authorities in the bulk power system. This paper focuses on secondary frequency control and leverages the conceptual similarity between balancing authorities and interconnected microgrids to adopt an automatic generation control design with some adaptations. Frequency control and restoration is demonstrated via several use-cases with switching and reconfiguration events.

Schweitzer, Eran↗

A Minimum Principle-Based Algorithm for Energy-Efficient Eco-Driving of Electric Vehicles in Various Traffic and Road Conditions

Our report presents an optimization algorithm for energy-efficient driving of electric vehicles. The algorithm is based on Pontryagin’s Minimum Principle by considering the driving mission as an optimal control problem. On a planned route, diverse application cases may occur due to various physical traits such as powertrain (e.g., switching between motor and generator operation), environmental variations (e.g., terrain grade change), traffic laws (e.g., speed limits), and safety concerns (e.g., headway to the leading vehicle). The proposed algorithm handles these real-world challenges by considering the perturbation to the system dynamics and the constraints to the control and state variables.

33 ADVANCED PROPULSION SYSTEMS↗

Anomalously abrupt switching of wurtzite-structured ferroelectrics: simultaneous non-linear nucleation and growth model

Ferroelectric polarization switching is one common example of a process that occurs via nucleation and growth, and understanding switching kinetics is crucial for applications such as ferroelectric memory. Here we describe and interpret anomalous switching dynamics in the wurtzite-structured nitride thin film ferroelectrics Al 0.7 Sc 0.3 N and Al 0.94 B 0.06 N using a general model that can be directly applied to other abrupt transitions that proceed via nucleation and growth. When substantial growth and impingement occur while nucleation rate is increasing, such as in these wurtzite-structured ferroelectrics under high electric fields, abrupt polarization reversal leads to very large Avrami coefficients ( e.g., n = 11), inspiring an extension of the KAI (Kolmogorov–Avrami–Ishibashi) model. We apply this extended model to two related but distinct scenarios that crossover between (typical) behavior described by sequential nucleation and growth and a more abrupt transition arising from significant growth prior to peak nucleation rate. This work therefore provides a more complete description of general nucleation and growth kinetics applicable to any system while specifically addressing the anomalously abrupt polarization reversal behavior in new wurtzite-structured ferroelectrics.

36 MATERIALS SCIENCE↗

Blockchain for Fault-Tolerant Grid Operations Version 2.0

This report explores the potential of distributed ledger technology (DLT) as a transformative tool to enhance fault-tolerant operations in electrical distribution systems. Leveraging DLT's core attributes, including an immutable decentralized ledger, distributed consensus mechanisms, and state replication capabilities, this study focuses on three critical use cases. A central aspect of this research centers on the utilization of a consensus-driven ledger, providing actors within the system, such as distributed resources, with access to a reliable data repository. This empowers these actors to collaborate effectively and make informed decisions, all securely recorded on the blockchain. The first use case concentrates on data configuration, utilizing mathematical criteria---particularly, the chi-squared test for gross error detection---to identify trustworthy sensors for advanced decision-making. Building upon this foundation of trust, the second use case, topology identification, accurately determines circuit breaker states, unveiling the distribution network's topology. Ultimately, the third use case leverages this trust to execute switching actions, reconfiguring feeders and restoring power to disconnected customers after fault events. The concept of trust serves as a cornerstone in this approach, marking a departure from traditional fault location, isolation, and service restoration (FLISR) methods. Additionally, the blockchain-based architecture introduces decentralization, empowering disconnected areas to make autonomous decisions, even when communication with a central control center is disrupted. The primary contributions of this report are twofold: (1) a novel approach for evaluating distribution system voltage areas while preserving data ownership and (2) the implementation of interactions between distribution network areas using the actor model. Unlike the previous sequential approach for evaluating the area connection voltages, which required a radial network topology, this study's area model reduction enables a more versatile approach. The area model reduction addresses issues of prolonged data waiting times and multiple points of failure within the previous approach. Notably, the presented evaluation for the reduced network model area connection reveals a significant increase in the differences in voltage magnitudes. Simulation and evaluation of area agents across four distinct cases elucidate the area-level interaction behavior during a fault event. Simulations demonstrate that the proposed distributed FLISR (DFLISR) approach can successfully restore service to an affected area. Varying message delays and message loss probabilities in each simulation case underscore their impacts on restoration times, ranging from 3 min and 32 s to 6 min and 19 s. In contrast, power is not restored in an area in one of our simulation cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Uncertainty quantification and reliability assessment for intermodal freight transportation

Intermodal freight optimization models support cost-effective, low-emission, and timely goods movement by coordinating trucks, rail, and barges. These models determine optimal flows, routing, and modal switches while respecting infrastructure and operational constraints. However, their real-world utility is often undermined by pervasive uncertainties-such as fluctuating transportation costs and emissions, variable terminal capacities, and uncertain freight demand-that distort key performance outcomes, including total system cost, carbon footprint, and transit time reliability. This study presents a structured framework for quantifying uncertainty in intermodal freight transportation (IFT) optimization. The framework evaluates how input uncertainty affects system performance and reliability, a critical need for ensuring that model-based decisions remain robust under real-world variability, especially amid volatile fuel prices, shifting demand, and growing disruptions. It integrates three complementary methods: (1) Sobol-based global sensitivity analysis to identify influential parameters affecting cost, emissions, and transit time, (2) Monte Carlo-based capacity perturbation analysis to assess robustness under probabilistic facility disruptions, and (3) Monte Carlo filtering with Bayesian inference to detect threshold-based performance vulnerabilities. The results highlight diesel truck unit cost as the dominant driver of variability. To improve system resilience, planners should prioritize uncertainty in fuel-related parameters when designing intermodal strategies.

Intermodal freight transportation↗

Deep mitigation of CO 2 and non-CO 2 greenhouse gases toward 1.5 °C and 2 °C futures

Stabilizing climate change well below 2 °C and towards 1.5 °C requires comprehensive mitigation of all greenhouse gases (GHG), including both CO 2 and non-CO 2 GHG emissions. Here we incorporate the latest global non-CO 2 emissions and mitigation data into a state-of-the-art integrated assessment model GCAM and examine 90 mitigation scenarios pairing different levels of CO 2 and non-CO 2 GHG abatement pathways. We estimate that when non-CO 2 mitigation contributions are not fully implemented, the timing of net-zero CO 2 must occur about two decades earlier. Conversely, comprehensive GHG abatement that fully integrates non-CO 2 mitigation measures in addition to a net-zero CO 2 commitment can help achieve 1.5 °C stabilization. While decarbonization-driven fuel switching mainly reduces non-CO 2 emissions from fuel extraction and end use, targeted non-CO 2 mitigation measures can significantly reduce fluorinated gas emissions from industrial processes and cooling sectors. Our integrated modeling provides direct insights in how system-wide all GHG mitigation can affect the timing of net-zero CO 2 for 1.5 °C and 2 °C climate change scenarios.

54 ENVIRONMENTAL SCIENCES↗

Performance Evaluation of Gray-box and Machine Learning Models of a Thermal Energy Storage System with Active Insulation

An interior partition wall integrated with active thermal storage and a dynamic insulation system was built and then installed in an office building in Oak Ridge, Tennessee, TN. This smart wall, termed the Empower Wall, was equipped with embedded pipes in the building envelope core component and an additional pipe network enclosing rigid insulation to switch on and off the active insulation dynamically. The performance of the wall's contribution to cooling load reduction under different parameters has been investigated in previous publications. Aiming to be deployed into model predictive control and other optimization methods, simplified and reliable models for the developed wall and the room accommodating it are required. They are needed to characterize the properties and thermal response of both Empower Wall and building envelope, which form an essential component for accurate indoor temperature or cooling/heating demand prediction. In this study, simplified gray-box and regression models as well as machine learning model were developed and the performance of them were compared and analyzed.

Cui, Borui↗

Power Quality and Stability in a Cluster of Microgrids with Coordinated Power and Energy Management

Distributed Energy Resources (DER) such as photovoltaic (PV) systems and battery energy storage systems (BESS) can be operated collectively as microgrids. Microgrids can be effective in meeting local load requirements as well as in improving the power quality and stability in a modern power distribution system. Multiple microgrids can also be operated in a coordinated manner as a cluster, to improve the resiliency of the power distribution system. In the event of an outage caused by a transmission system failure, the microgrids in a cluster can use their distributed generation capacity and energy storage resources to recover and extend power availability to the critical loads in the system. In this paper, an illustrative cluster of two microgrids based on the IEEE 13-bus model with DERs has been used, to demonstrate the operation of the concept using real-time simulations. Using real-time simulations, capabilities such as switching reconfiguration following faults, identification of optimal DER placement for effective power quality management, and power electronic controller validation have been demonstrated. For the two-microgrid cluster, this paper also presents improvements in load voltage quality and

Chowdhury, Prithwiraj Roy↗