Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Surgery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Shoulder Injuries in US Astronauts Related to EVA Suit Design

Introduction: For every one hour spent performing extravehicular activity (EVA) in space, astronauts in the US space program spend approximately six to ten hours training in the EVA spacesuit at NASA-Johnson Space Center's Neutral Buoyancy Lab (NBL). In 1997, NASA introduced the planar hard upper torso (HUT) EVA spacesuit which subsequently replaced the existing pivoted HUT. An extra joint in the pivoted shoulder allows increased mobility but also increased complexity. Over the next decade a number of astronauts developed shoulder problems requiring surgical intervention, many of whom performed EVA training in the NBL. This study investigated whether changing HUT designs led to shoulder injuries requiring surgical repair. Methods: US astronaut EVA training data and spacesuit design employed were analyzed from the NBL data. Shoulder surgery data was acquired from the medical record database, and causal mechanisms were obtained from personal interviews Analysis of the individual HUT designs was performed as it related to normal shoulder biomechanics. Results: To date, 23 US astronauts have required 25 shoulder surgeries. Approximately 48% (11/23) directly attributed their injury to training in the planar HUT, whereas none attributed their injury to training in the pivoted HUT. The planar HUT design limits shoulder abduction to 90 degrees compared to approximately 120 degrees in the pivoted HUT. The planar HUT also forces the shoulder into a forward flexed position requiring active retraction and extension to increase abduction beyond 90 degrees. Discussion: Multiple factors are associated with mechanisms leading to shoulder injury requiring surgical repair. Limitations to normal shoulder mechanics, suit fit, donning/doffing, body position, pre-existing injury, tool weight and configuration, age, in-suit activity, and HUT design have all been identified as potential sources of injury. Conclusion: Crewmembers with pre-existing or current shoulder injuries or certain anthropometric body types should conduct NBL EVA training in the pivoted HUT.

Scheuring, R. A.↗

NASA Tech Briefs, October 2003

Topics covered include: Cryogenic Temperature-Gradient Foam/Substrate Tensile Tester; Flight Test of an Intelligent Flight-Control System; Slat Heater Boxes for Thermal Vacuum Testing; System for Testing Thermal Insulation of Pipes; Electrical-Impedance-Based Ice-Thickness Gauges; Simulation System for Training in Laparoscopic Surgery; Flasher Powered by Photovoltaic Cells and Ultracapacitors; Improved Autoassociative Neural Networks; Toroidal-Core Microinductors Biased by Permanent Magnets; Using Correlated Photons to Suppress Background Noise; Atmospheric-Fade-Tolerant Tracking and Pointing in Wireless Optical Communication; Curved Focal-Plane Arrays Using Back-Illuminated High-Purity Photodetectors; Software for Displaying Data from Planetary Rovers; Software for Refining or Coarsening Computational Grids; Software for Diagnosis of Multiple Coordinated Spacecraft; Software Helps Retrieve Information Relevant to the User; Software for Simulating a Complex Robot; Software for Planning Scientific Activities on Mars; Software for Training in Pre-College Mathematics; Switching and Rectification in Carbon-Nanotube Junctions; Scandia-and-Yttria-Stabilized Zirconia for Thermal Barriers; Environmentally Safer, Less Toxic Fire-Extinguishing Agents; Multiaxial Temperature- and Time-Dependent Failure Model; Cloverleaf Vibratory Microgyroscope with Integrated Post; Single-Vector Calibration of Wind-Tunnel Force Balances; Microgyroscope with Vibrating Post as Rotation Transducer; Continuous Tuning and Calibration of Vibratory Gyroscopes; Compact, Pneumatically Actuated Filter Shuttle; Improved Bearingless Switched-Reluctance Motor; Fluorescent Quantum Dots for Biological Labeling; Growing Three-Dimensional Corneal Tissue in a Bioreactor; Scanning Tunneling Optical Resonance Microscopy; The Micro-Arcsecond Metrology Testbed; Detecting Moving Targets by Use of Soliton Resonances; and Finite-Element Methods for Real-Time Simulation of Surgery.

Source record↗

Do Astronauts Havbe a Higher Rate of Orthopedic Shoulder Conditions Than a Cohort of Working Professionals

Occupational surveillance of astronaut shoulder injuries began with operational concerns at the Neutral Buoyancy Laboratory (NBL) during Extra Vehicular Activity (EVA) training. Orthopedic shoulder injury and surgery rates were calculated [1], but classifying the rates as normal, high or low was highly dependent on the comparison group. Thus, the purpose of this study was to identify a population of working professionals and compare orthopedic shoulder consultation and surgery rates.

Laughlin, M. S.↗

Utilization of the NASA Robonaut as a Surgical Avatar in Telemedicine

The concept of teleoperated robotic surgery is not new; however, most of the work to date has utilized specialized robots designed for specific set of surgeries. This activity explores the use of a humanoid robot to perform surgical procedures using the same hand held instruments that a human surgeon employs. For this effort, the tele-operated Robonaut (R2) was selected due to its dexterity, its ability to perform a wide range of tasks, and its adaptability to changing environments. To evaluate this concept, a series of challenges was designed with the goal of assessing the feasibility of utilizing Robonaut as a telemedicine based surgical avatar.

Dean, Marc↗

Do Astronauts have a Higher Rate of Orthopedic Shoulder Conditions than a Cohort of Working Professionals?

Occupational surveillance of astronaut shoulder injuries began with operational concerns at the Neutral Buoyancy Laboratory (NBL) during Extra Vehicular Activity (EVA) training. NASA has implemented several occupational health initiatives during the past 20 years to decrease the number and severity of injuries, but the individual success rate is unknown. Orthopedic shoulder injury and surgery rates were calculated, but classifying the rates as normal, high or low was highly dependent on the comparison group. The purpose of this study was to identify a population of working professionals and compare orthopedic shoulder consultation and surgery rates.

Laughlin, Mitzi S.↗

Structural manipulation of microcone arrays for microsurgical modification of ophthalmic tissues

The purpose of this study was to control the size and shape of fabricated glass microcone arrays for use in optical surgery instruments by varying the fiber drawing and etching methods. The spacing of the cones is controlled via the drawing process while the etching process controls the cone height-to-base ratio. The device viability was tested by imprinting, and subsequent staining, of low-density polyethylene and porcine corneas, resulting in a consistent patterned structure of micron-sized perforations. After imprint, the device was examined and no evidence of microcone fracture or over-penetration was present during the course of these experiments. This research promises to lead to advances in optical surgery for the treatment of recurrent corneal erosions, providing quicker, safer, and more cost-effective procedures with decreased risk of vision loss and scarring associated with current procedures such as anterior stromal puncture. The ease of procedure and micron sized incisions could potentially replace current techniques and provide a viable treatment alternative for recurrent corneal erosions in the visual axis.

Schaeffer, Daniel A↗

An Industrial Steerable Needle for Inspecting Extremely Confined Spaces in Nuclear Facilities - 18316

We present a novel, compliant mechanism inspired by steerable needles for endoscopic surgery that provides the capability to navigate extremely confined spaces for the purpose of infrastructure inspection. Extremely confined spaces are commonly encountered during infrastructure inspection of nuclear facilities. These spaces can include pipes and ventilation ducts. Often these infrastructure features go uninspected simply because there is no viable way to access their interior. In addition, it is not uncommon for extremely confined spaces to be laid-out in a spider-web fashion that must be selectively navigated in order to execute an inspection. Recently, millimeter-scale imagers have become commercially available. These imagers are small enough to fit inside an extremely confined space, but there is currently no means to bring the imager to the portion of the structure that must be inspected. In this work this problem is addressed by taking inspiration from the field of steerable needles used in endoscopic surgery. Steerable needles are long flexible shafts that are capable of being directed through the human body using control forces applied external to the body. Unfortunately, steerable needles cannot be directly applied to the problem of navigating maze-like arrangements of extremely confined spaces. Traditional steerable needles must operate within a solid medium that can be penetrated in order to be steered so they are not directly applicable to navigating extremely confined spaces. However surgical steerable needles do suggest an approach to the problem. Steerable needles are typically made from super-elastic nitinol. This material has the property that it can experience high strain without yielding. Furthermore, superelastic nitinol is stiff enough that it is possible to push the tube down a long, maze-like arrangement of a confined space without buckling. The stiffness properties of nitinol combined with its high yield strain makes it an attractive material for navigating a tube through a maze-like arrangement of extremely confined spaces. The ability to selectively navigate extremely confined spaces opens up new possibilities to use emerging miniature imaging technology for infrastructure inspection. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radio-guided occult lesion localisation using iodine 125 Seeds “ROLLIS” to guide surgical removal of an impalpable posterior chest wall melanoma metastasis

Cancer screening and surveillance programmes and the use of sophisticated imaging tools such as positron emission tomography-computed tomography (PET-CT) have increased the detection of impalpable lesions requiring imaging guidance for excision. A new technique involves intra-lesional insertion of a low-activity iodine-125 ({sup 125}I) seed and detection of the radioactive signal in theatre using a hand-held gamma probe to guide surgery. Whilst several studies describe using this method to guide the removal of impalpable breast lesions, only a handful of publications report its use to guide excision of lesions outside the breast. We describe a case in which radio-guided occult lesion localisation using an iodine 125 seed was used to guide excision of an impalpable posterior chest wall metastasis detected on PET-CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-modulated radiation therapy to bilateral lower limb extremities concurrently: a planning case study

Non-melanomatous skin cancers represent 80% of all newly diagnosed cancers in Australia with basal cell carcinoma (BCC) and squamous cell carcinoma (SCC) being the most common. A previously healthy 71-year-old woman presented with widespread and tender superficial skin cancers on the lower bilateral limbs. External beam radiation therapy through the use of intensity-modulated radiation therapy (IMRT) was employed as the treatment modality of choice as this technique provides conformal dose distribution to a three-dimensional treatment volume while reducing toxicity to surrounding tissues. The patient was prescribed a dose of 60 Gy to the planning target volume (PTV) with 1.0 cm bolus over the ventral surface of each limb. The beam arrangement consisted of six treatment fields that avoided entry and exit through the contralateral limb. The treatment plans met the International Commission on Radiation Units and Measurements (ICRU) guidelines and produced highly conformal dosimetric results. Skin toxicity was measured against the National Cancer Institute: Common Terminology Criteria for Adverse Events (NCI: CTCAE) version 3. A well-tolerated treatment was delivered with excellent results given the initial extent of the disease. This case study has demonstrated the feasibility and effectiveness of IMRT for skin cancers as an alternative to surgery and traditional superficial radiation therapy, utilising a complex PTV of the extremities for patients with similar presentations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The cardiac dose-sparing benefits of deep inspiration breath-hold in left breast irradiation: a systematic review

Despite technical advancements in breast radiation therapy, cardiac structures are still subject to significant levels of irradiation. As the use of adjuvant radiation therapy after breast-conserving surgery continues to improve survival for early breast cancer patients, the associated radiation-induced cardiac toxicities become increasingly relevant. Our primary aim was to evaluate the cardiac-sparing benefits of the deep inspiration breath-hold (DIBH) technique. An electronic literature search of the PubMed database from 1966 to July 2014 was used to identify articles published in English relating to the dosimetric benefits of DIBH. Studies comparing the mean heart dose of DIBH and free breathing treatment plans for left breast cancer patients were eligible to be included in the review. Studies evaluating the reproducibility and stability of the DIBH technique were also reviewed. Ten studies provided data on the benefits of DIBH during left breast irradiation. From these studies, DIBH reduced the mean heart dose by up to 3.4 Gy when compared to a free breathing approach. Four studies reported that the DIBH technique was stable and reproducible on a daily basis. According to current estimates of the excess cardiac toxicity associated with radiation therapy, a 3.4 Gy reduction in mean heart dose is equivalent to a 13.6% reduction in the projected increase in risk of heart disease. DIBH is a reproducible and stable technique for left breast irradiation showing significant promise in reducing the late cardiac toxicities associated with radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Expanding the indications for MRI in the diagnosis and treatment of breast cancer: what is best practice?

Breast magnetic resonance imaging (MRI) now has an accepted place in screening younger women at high risk of breast cancer, and is increasingly used in a number of other settings including assessment of response to neo-adjuvant therapy and local staging of cancer. Although the evidence for its general use in these settings is very limited, in highly selected patients, especially where discordance with conventional measurements occurs, MRI can have a place in assessing extent of disease, both whether operable and how operable, and guiding surgery. These scenarios and future indications and alternative technologies are explored in this paper.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Contrast- vs. non-contrast enhanced MR data sets for characterization of perianal fistulas

Purpose: To evaluate the diagnostic efficacy between pre- and post-contrast MRI sequences in perianal fistulas using intra-operative findings as the gold standard. Materials and methods: Retrospective analysis of 50 patients with a history of perianal fistula and MRI performed between January 2006 and January 2018 was performed. The inclusion criteria were patients who underwent MRI prior to surgery and had a detailed surgical report available. Pre- and post-contrast MR data sets were evaluated by two radiologists at two-week-intervals, assessed fistula type, internal/external opening, presence of abscess/secondary tracts, and confidence scores. The area under the curve (AUC) was used for comparison the diagnostic ability. The sensitivity and specificity were compared using the McNemar’s test. Results: The confidence scores in detecting perianal fistulas were significantly higher in the post-contrast MR data set (p < 0.003). The post-contrast MR data set had similar ability to classify perianal fistulas as combined T2-DWI and isolated T2 data sets in 49/50 cases. For internal/external opening, the post-contrast MR, combined T2-DWI, and isolated T2 data sets had 100% concordance with intra-operative reports. For perianal abscess, there was no significant difference in sensitivity or AUC value between the isolated T2 or combined T2-DWI data sets and post-contrast MR data set (p > 0.05). All MR data sets correctly identified secondary tracts in all 50 cases. Conclusions: Although contrast-enhanced MR studies can improve a radiologist’s confidence, non-contrast MR studies had similar diagnostic efficacy in identifying perianal fistulas and their complications. Therefore, a non-contrast study may suffice in selected patients such as those with renal impairment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of recurrent pancreatic cancer: value of second-opinion interpretations of cross-sectional images by subspecialized radiologists

Purpose: To investigate the value of second-opinion interpretation of cross-sectional images by subspecialized radiologists to diagnose recurrent pancreatic cancer after surgery. Methods: The IRB approved and issued a waiver of informed consent for this retrospective study. Initial and second-opinion interpretations of 69 consecutive submitted MRI or CT follow-up after pancreatic cancer resection between January 1, 2009 and December 31, 2013 were evaluated by one oncologic imaging radiologist, who was blinded to patient’s clinical details and histopathologic data. The reviewer was asked to classify each interpretation in reference of the diagnosis of PDAC recurrence. It was also recorded if the radiologic interpretation recommended additional imaging studies to confirm recurrence. The diagnosis of recurrence was determined by pathology when available, otherwise by imaging follow-up, clinical, or laboratory assessments. Cohen’s kappa statistic was used to assess agreement between initial and second-opinion interpretations. The differences between the initial and second-opinion interpretations were examined using McNemar test or Bowker’s test of symmetry. Results: Disagreement on recurrence between the initial report and the second-opinion interpretation was observed in 32% of cases (22/69; k = 0.44). Second-opinion interpretations had a higher sensitivity and a higher specificity on recurrence compared to the initial interpretations (0.93 vs. 0.75 and 0.90 vs. 0.68, respectively), and the difference in specificity was significant (p = 0.016). Additional imaging studies were recommended more frequently in the initial interpretation (22% vs. 6%, p = 0.006). Conclusions: Our study shows the second-opinion interpretation by subspecialized radiologists improves the detection of pancreatic cancer recurrence after surgical resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of renal stone composition by using fast kilovoltage switching dual-energy computed tomography compared to laboratory stone analysis: a pilot study

Purpose: To prospectively examine the diagnostic performance of fast kilovoltage switching dual-energy computed tomography (DECT) in characterization of in vivo renal stone composition compared with postoperative stone analysis. Methods: Consecutive consenting patients scheduled for endoscopic kidney stone surgery in a tertiary referral hospital from June 2015 to January 2016 were enrolled. Patients were preoperatively scanned with single-source, fast kilovoltage switching DECT. Stone compositions were determined regarding the effective atomic number measurements. Results of the stone compositions from DECT were compared to postoperative infrared spectroscopy stone analysis as the standard reference. Results: For the 39 patients enrolled in the study, DECT was able to detect uric acid stone with sensitivity of 88.9% and specificity of 100%. There was 100% positive predictive value, 96.8% negative predictive value, and 97.4% accuracy. For non-contrast CT scan, sensitivity was 88.9%, specificity was 96.7%, positive predictive value was 88.9%, negative predictive value was 96.7%, and accuracy was 94.8%. Of the 39 samples examined, 21 (54%) were single composition, whereas 18 (46%) were combined. Single composition stones were correctly characterized by DECT in 100% (8/8) for uric acid. Whereas the result of uric acid stone containing stone discrimination in mixed composition was not so good with Z{sub eff} alone, iodine imaging can compensated this fault. Conclusions: DECT provides excellent accuracy in characterizing uric acid stone compositions. With the addition of iodine image, all of uric acid-containing stones can be determined by the DECT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic resonance imaging features of pubic symphysis urinary fistula with pubic bone osteomyelitis in the treated prostate cancer patient

Introduction: Pubic bone osteomyelitis with pubic symphysis urinary fistula represents a debilitating complication of radiation and ablative treatments for prostate cancer. The definitive radiographic diagnosis of this clinical entity is not described. In this study, we characterize the plain film and magnetic resonance imaging findings of pubic osteomyelitis. Materials and Methods: We reviewed a database of prostate cancer survivors with diagnosed pubic osteomyelitis from 2011 to 2015. These patients underwent pelvic plain radiographs and magnetic resonance imaging with T1-weighted and fat-suppressed T2-weighted fast spin echo sequences. Intravenous gadolinium was utilized. The diagnosis was verified with extirpative surgery. 16 patients with diagnosed pubic osteomyelitis from 2011 to 2015 underwent imaging at our institution. Results: All patients demonstrated increased signal on T2- weighted sequences and decreased signal on T1-weighted sequences along the pubic symphysis and the marrow of the involved pubic rami. Inflammatory myositis with diastasis of the pubic symphysis and cortical bone erosion were identified in the majority of patients. Fluid collections were identified in 75% of patients. 63% of conventional radiographs demonstrated no radiographic evidence of pubic osteomyelitis. Conclusion: Magnetic resonance imaging of pubic symphysis osteomyelitis in the prostate cancer survivor is characterized by high signal on T2-weighted images and low signal on T1-weighted images of the involved pubic rami, with the majority of patients demonstrating regional myositis. Imaging data combined with clinical assessment should prompt diagnosis and management of pubic osteomyelitis. Conventional radiography is generally insensitive to these findings. We consider magnetic resonance imaging to be the definitive diagnostic modality for this clinical entity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multimodality imaging of the Meso-Rex bypass

Extrahepatic portal vein obstruction (EHPVO) is the most common cause of upper gastrointestinal bleeding in children. It is defined as thrombosis of the extrahepatic portal vein with or without extension to the intrahepatic portal veins. The Meso-Rex shunt is the gold standard treatment in children with favorable anatomy since it restores physiological portal liver reperfusion. This is achieved by rerouting the splanchnic venous blood through an autologous graft from the superior mesenteric vein (SMV) into the Rex recess of the left portal vein, curing portal hypertension by doing so. General and hepatobiliary radiologists must be familiar with multimodality imaging appearances of EHPVO and with the role of imaging in identifying suitable candidates for Meso-Rex bypass surgery. Imaging might also detect complications of this procedure, some of which might be treated via interventional radiology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Association between CT-texture-derived tumor heterogeneity, outcomes, and BRCA mutation status in patients with high-grade serous ovarian cancer

Purpose: To assess the associations between inter-site texture heterogeneity parameters derived from computed tomography (CT), survival, and BRCA mutation status in women with high-grade serous ovarian cancer (HGSOC). Materials and methods: Retrospective study of 88 HGSOC patients undergoing CT and BRCA mutation status testing prior to primary cytoreductive surgery. Associations between texture metrics—namely inter-site cluster variance (SCV), inter-site cluster prominence (SCP), inter-site cluster entropy (SE)—and overall survival (OS), progression-free survival (PFS) as well as BRCA mutation status were assessed. Results: Higher inter-site cluster variance (SCV) was associated with lower PFS (p = 0.006) and OS (p = 0.003). Higher inter-site cluster prominence (SCP) was associated with lower PFS (p = 0.02) and higher inter-site cluster entropy (SE) correlated with lower OS (p = 0.01). Higher values of all three metrics were significantly associated with lower complete surgical resection status in BRCA-negative patients (SE p = 0.039, SCV p = 0.006, SCP p = 0.02), but not in BRCA-positive patients (SE p = 0.7, SCV p = 0.91, SCP p = 0.67). None of the metrics were able to distinguish between BRCA mutation carrier and non-mutation carrier. Conclusion: The assessment of tumoral heterogeneity in the era of personalized medicine is important, as increased heterogeneity has been associated with distinct genomic abnormalities and worse patient outcomes. A radiomics approach using standard-of-care CT scans might have a clinical impact by offering a non-invasive tool to predict outcome and therefore improving treatment effectiveness. However, it was not able to assess BRCA mutation status in women with HGSOC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving preoperative detection of synchronous liver metastases in pancreatic cancer with combined contrast-enhanced and diffusion-weighted MRI

Purpose: To explore the value of gadolinium-enhanced MRI combined with diffusion-weighted MRI (Gd-enhanced MRI with DWI) in addition to contrast-enhanced CT (CECT) for detection of synchronous liver metastases for potentially resectable pancreatic cancer. Methods: By means of a retrospective cohort study we included patients with potentially resectable pancreatic cancer on CECT, who underwent Gd-enhanced MRI with DWI between January 2012 and December 2016. A single observer evaluated MRI and CT and was blinded to imaging, pathology, and surgery reports. Liver lesions were scored in both modalities, using a 3-point scale: 1-benign, 2-indeterminate, 3- malignant (i.e., metastasis). The primary outcome parameters were the presence of liver metastases on Gd-enhanced MRI with DWI and the sensitivity of Gd-enhanced MRI with DWI for synchronous liver metastases. Results: We included 66 patients (42 men, 24 women; median age 65 years, range 36–82 years). In 19 patients, liver metastases were present, which were confirmed by histopathology (n = 12), {sup 18}FDG-PET (n = 6), or surgical inspection (n = 1). Gd-enhanced MRI with DWI showed metastases in 16/19 patients (24%), which resulted in a sensitivity of 84% (95% CI 60–97%). Contrast-enhanced MRI showed 156 and DWI 397 metastases (p = 0.051), and 339 were particularly small (< 5 mm). Conclusions: In this study, Gd-enhanced MRI with DWI detected synchronous liver metastases in 24% of patients with potentially resectable pancreatic cancer on CECT with a sensitivity of 84%. Diffusion-weighted MRI showed a greater number of metastases than any other sequence, particularly small metastases (< 5 mm).

62 RADIOLOGY AND NUCLEAR MEDICINE↗