Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Surface Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Concentration transient analysis of antimony surface segregation during Si(100) molecular beam epitaxy

Antimony surface segregation during Si(100) molecular beam epitaxy (MBE) was investigated at temperatures T(sub s) = 515 - 800 C using concentration transient analysis (CTA). The dopant surface coverage Theta, bulk fraction gamma, and incorporation probability sigma during MBE were determined from secondary-ion mass spectrometry depth profiles of modulation-doped films. Programmed T(sub s) changes during growth were used to trap the surface-segregated dopant overlayer, producing concentration spikes whose integrated area corresponds to Theta. Thermal antimony doping by coevaporation was found to result in segregation strongly dependent on T(sub s) with Theta(sub Sb) values up to 0.9 monolayers (ML): in films doped with Sb(+) ions accelerated by 100 V, Theta(sub Sb) was less than or equal to 4 x 10(exp -3) ML. Surface segregation of coevaporated antimony was kinematically limited for the film growth conditions in these experiments.

Markert, L. C.↗

Detection and analysis of cyclotrimethylenetrinitramine (RDX) in environmental samples by surface-enhanced Raman spectroscopy

Techniques for rapid and sensitive detection of energetics such as cyclotrimethylenetrinitramine (RDX) are needed both for environmental and security screening applications. Here we report the use of surface-enhanced Raman scattering (SERS) spectroscopy to detect traces of RDX with good sensitivity and reproducibility. Using gold (Au) nanoparticles ( 90 100 nm in diameter) as SERS substrates, RDX was detectable at concentrations as low as 0.15 mg/l in a contaminated groundwater sample. This detection limit is about two orders of magnitude lower than those reported previously using SERS techniques. A surface enhancement factor of 6 104 was obtained. This research further demonstrates the potential for using SERS as a rapid, in situ field screening tool for energetics detection when coupled with a portable Raman spectrometer.

54 ENVIRONMENTAL SCIENCES↗

Comprehensive Assessment of Global Surface Net Radiation Products and Uncertainty Analysis

Abstract Earth surface net radiation ( R n ) characterizes the surface radiation budget and plays a critical role in ecological, biogeochemical, and hydrological processes. The R n products from remote sensing and reanalysis have not been validated comprehensively. In this study, four R n products (Clouds and the Earth's Radiant Energy System [CERES], ERA‐Interim, Modern‐Era Retrospective analysis for Research and Applications version 2, and Japanese 55‐year Reanalysis) were validated using global ground measurements on monthly (255 sites) and annual (172 sites) timescales. These products have similar accuracies, with average root‐mean‐square error (RMSE) ranges of 5.35 W m −2 (monthly) and 2.30 W m −2 (annually). However, varying accuracies and systemic biases exist across different climatic zones. The annual land R n intercomparison illustrates that large uncertainty exists over polar regions and deserts. A significantly negative annual anomaly in the CERES product for the 2001–2008 period is identified when examining annual R n anomalies over the global land surface. Detailed uncertainty analysis indicates that the global CERES R n anomaly is mainly due to different versions of input data such as aerosol optical thickness and atmospheric profiles (in 2006 and 2008) and cloud properties (in 2002). This work demonstrates that temporal analysis provides powerful quality control for global time series satellite products when the validation using ground measurements fails to capture potential issues.

Jia, Aolin↗

A Compact Two-Step Laser Time-Of-Flight Mass Spectrometer for In Situ Analysis of Planetary Surfaces

Two-step laser mass spectrometry (L2MS) has proved to be a powerful tool for the analysis of aromatic organics in icy planetary simulants, meteorites, asphaltenes on Earth, and returned cometary particles from the Stardust mission. L2MS employs two lasers to separate the desorption and ionization processes of laser desorption ionization into distinct steps. In the first step, an infrared laser desorbs neutrals from a solid sample surface; in the second step, an ultraviolet laser forms molecular ions within the neutral plume through a resonance-enhanced process to minimize fragment at ion of complex species. We have recently demonstrated that the L2MS technique is compatible with a compact TOF-MS that could form the center piece of a future in situ landed planetary mission emphasizing surface chemistry or astrobiology. The increased sensitivity and selectivity offered by this technique has been demonstrated in analyses of various planetary analog mixtures and meteorite powders, and representative results of these analyses will be presented.

Getty, Stephanie A.↗

Surface flaw reliability analysis of ceramic components with the SCARE finite element postprocessor program

The SCARE (Structural Ceramics Analysis and Reliability Evaluation) computer program on statistical fast fracture reliability analysis with quadratic elements for volume distributed imperfections is enhanced to include the use of linear finite elements and the capability of designing against concurrent surface flaw induced ceramic component failure. The SCARE code is presently coupled as a postprocessor to the MSC/NASTRAN general purpose, finite element analysis program. The improved version now includes the Weibull and Batdorf statistical failure theories for both surface and volume flaw based reliability analysis. The program uses the two-parameter Weibull fracture strength cumulative failure probability distribution model with the principle of independent action for poly-axial stress states, and Batdorf's shear-sensitive as well as shear-insensitive statistical theories. The shear-sensitive surface crack configurations include the Griffith crack and Griffith notch geometries, using the total critical coplanar strain energy release rate criterion to predict mixed-mode fracture. Weibull material parameters based on both surface and volume flaw induced fracture can also be calculated from modulus of rupture bar tests, using the least squares method with known specimen geometry and grouped fracture data. The statistical fast fracture theories for surface flaw induced failure, along with selected input and output formats and options, are summarized. An example problem to demonstrate various features of the program is included.

Gyekenyesi, John P.↗

Surface flaw reliability analysis of ceramic components with the SCARE finite element postprocessor program

The SCARE (Structural Ceramics Analysis and Reliability Evaluation) computer program on statistical fast fracture reliability analysis with quadratic elements for volume distributed imperfections is enhanced to include the use of linear finite elements and the capability of designing against concurrent surface flaw induced ceramic component failure. The SCARE code is presently coupled as a postprocessor to the MSC/NASTRAN general purpose, finite element analysis program. The improved version now includes the Weibull and Batdorf statistical failure theories for both surface and volume flaw based reliability analysis. The program uses the two-parameter Weibull fracture strength cumulative failure probability distribution model with the principle of independent action for poly-axial stress states, and Batdorf's shear-sensitive as well as shear-insensitive statistical theories. The shear-sensitive surface crack configurations include the Griffith crack and Griffith notch geometries, using the total critical coplanar strain energy release rate criterion to predict mixed-mode fracture. Weibull material parameters based on both surface and volume flaw induced fracture can also be calculated from modulus of rupture bar tests, using the least squares method with known specimen geometry and grouped fracture data. The statistical fast fracture theories for surface flaw induced failure, along with selected input and output formats and options, are summarized. An example problem to demonstrate various features of the program is included.

Gyekenyesi, J. P.↗

Experimental study of surface cracks

Analysis of plastic zones surrounding surface cracks in stressed steel and titanium plates subjected to tensile loading shows that back surface dimpling develops at stress levels considerably lower than those predicted by theoretical models of yield zone penetration into back surface.

Source record↗

Automated fit of high-dimensional potential energy surfaces using cluster analysis and interpolation over descriptors of chemical environment

We present a method for fitting high-dimensional potential energy surfaces that is almost fully automated, can be applied to systems with various chemical compositions, and involves no particular choice of function form. We tested it on four systems: Ag{sub 20}, Sn{sub 6}Pb{sub 6}, Si{sub 10}, and Li{sub 8}. The cost for energy evaluation is smaller than the cost of a density functional theory (DFT) energy evaluation by a factor of 1500 for Li{sub 8}, and 60 000 for Ag{sub 20}. We achieved intermediate accuracy (errors of 0.4 to 0.8 eV on atomization energies, or, 1% to 3% on cohesive energies) with rather small datasets (between 240 and 1400 configurations). We demonstrate that this accuracy is sufficient to correctly screen the configurations with lowest DFT energy, making this function potentially very useful in a hybrid global optimization strategy. We show that, as expected, the accuracy of the function improves with an increase in the size of the fitting dataset.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational and theoretical analysis of free surface flow in a thin liquid film under zero and normal gravity

The results of a numerical computation and theoretical analysis are presented for the flow of a thin liquid film in the presence and absence of a gravitational body force. Five different flow systems were used. Also presented are the governing equations and boundary conditions for the situation of a thin liquid emanating from a pressure vessel; traveling along a horizontal plate with a constant initial height and uniform initial velocity; and traveling radially along a horizontal disk with a constant initial height and uniform initial velocity.

Faghri, Amir↗

Comparison of SMOS and Aquarius Sea Surface Salinity and Analysis of Possible Causes for the Differences

Two ongoing space missions share the scientific objective of mapping the global Sea Surface Salinity (SSS), yet their observations show significant discrepancies. ESA's Soil Moisture and Ocean Salinity (SMOS) and NASA's Aquarius use L-band (1.4 GHz) radiometers to measure emission from the sea surface and retrieve SSS. Significant differences in SSS retrieved by both sensors are observed, with SMOS SSS being generally lower than Aquarius SSS, except for very cold waters where SMOS SSS is the highest overall. Figure 1 is an example of the difference between the SSS retrieved by SMOS and Aquarius averaged over one month and 1 degree in longitude and latitude. Differences are mostly between -1 psu and +1 psu (psu, practical salinity unit), with a significant regional and latitudinal dependence. We investigate the impact of the vicarious calibration and some components of the retrieval algorithm used by both mission on these differences.

microwave remote sensing↗

Local-Regional Surface Wave Dispersion Analysis using Ambient Noise Data of the Southern Nevada National Security Site Area

This report details seismic ambient noise analysis to improve seismic velocity estimates of the southeastern Nevada National Security Site (NNSS). We compare two different methods for estimating surface wave dispersion curves from ambient noise cross-correlations: frequency time analysis (FTAN) and Aki’s cross-spectral method (XSpec). We find that XSpec performs better for our local-regional dataset and frequency content. Using phase velocity estimates from XSpec, we build a preliminary phase velocity dispersion dataset, which contains data for 1,054 station pairs and 8,905 discrete phase velocity measurements for periods between 0.5 and 13 s. This phase velocity dataset will be incorporated into an updated local-regional P and S wave velocity model of the southeastern NNSS in the future and is expected to improve upon shallow velocity estimates.

47 OTHER INSTRUMENTATION↗

SU-C-BRF-02: Surface Imaging Based Analysis of Intra-Fraction Motion for Breast Radiotherapy Patients

Purpose: To quantify and characterize intrafraction motion for breast radiotherapy treatments using 3D surface imaging. Methods: Thirty free breathing breast patients were monitored with 3D surface imaging over a total of 831 monitoring sessions. Mean translations and rotations were calculated over each minute, each session, and over all sessions combined. The percentage of each session that the root mean square (RMS) of the linear translations were outside of 2 mm, 3 mm, 4 mm, and 5 mm were determined for each patient. Correlations between mean translations per minute and time and between standard deviation per minute and time were evaluated using Pearson's r value. Results: The mean RMS translation averaged over all patients was 2.63 mm +/- 1.63 mm. The patients spent an average of 52%, 24%, 11%, and 5% of the monitoring time outside of 2 mm, 3 mm, 4 mm, and 5 mm RMS tolerances, respectively. The RMS values averaged over all patients were 2.95 mm +/- 1.67 mm, 3.21 +/- 2.11, and 3.57 mm +/- 2.23 mm over the 5th, 10th, and 15th minutes of monitoring, respectively. The RMS values (r = 0.95, p = 0) and the standard deviations of the RMS values (r = 0.97, p = 0) both showed strong significant correlations with time. Conclusion: The majority of patients treatment time is spent within 5 mm of the isocenter. Patient position tends to drift with increasing time in the session. Treatment length should be considered when determining planning margins. An 8 mm margin on a target volume would account for two standard deviations of motion for a treatment up to 15 minutes in length.

60 APPLIED LIFE SCIENCES↗

Surface and interface analysis of nanomaterials at microfocus beamline (BL-16) of Indus-2

Analysis of chemical nature and electronic structure at the interface of a thin film medium is important in many technological applications as well as to understand overall efficiency of a thin film device. Synchrotron radiation based x-ray spectroscopy is a promising technique to study interface nature of the nanomaterials with atomic resolutions. A combined x-ray reflectivity and grazing incidence x-ray fluorescence measurement facility has been recently constructed at the BL-16 microfocus beamline of Indus-2 synchrotron facility to accomplish surface-interface microstructural characterization of thin layered materials. It is also possible to analyze contaminates or adsorbed ad-atoms on the surface of the thin nanostructure materials. The BL-16 beamline also provides an attractive platform to perform a variety of analytical research activities especially in the field of micro x-ray fluorescence and ultra-trace elements analysis using Synchrotron radiation. We describe various salient features of the BL-16 reflectometer experimental station and the detailed description of its capabilities through the measured results, obtained for various thin layered nanomaterials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of the variational SEASAT data analysis technique

Surface winds are closely associated with the surface pressure gradient. The variational SEASAT data analysis technique was designed to improve the sea level pressure analysis in the data sparse areas. The SEASAT-derived surface wind data were compared with observations from the Joint Air Sea Interaction Experiment (JASIN) and it was found that the satellite-derived sea surface wind has an accuracy of up to + or - 2 m/s in speed and + or - 20 deg in direction. These numbers are considered characteristic of the retrieved SEASAT wind field. By combining the densely spaced SEASAT-derived wind data with the sparsely distributed sea-level pressure observation via a variational adjustment technique subject to some appropriate physical constraint(s), an improvement in the sea-level pressure analysis is expected. It is demonstrated that a simple marine boundary layer scheme in conjunction with a variational adjustment technique can be developed to help improve the sea-level pressure analysis by the SEASAT-derived wind of a limited-area domain in the ocean.

Sasaki, Y. K.↗