Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Storage capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Assessment of tank designs for hydrogen storage on heavy duty vehicles using metal hydrides

The objective of this project was to evaluate material-based hydrogen storage solutions as a replacement for high-pressure hydrogen gas or liquid hydrogen on Class 7 or 8 tractor fuel cell electric vehicles. The project focused on low-density main-group hydrides, a well-known class of materials for hydrogen storage. Prior research has considered metal amides as storage materials for light-duty vehicles but not for heavy-duty applications. The project established the basis for further development of storage systems of this type for heavy duty vehicles (HDV). Systems analysis of an HDV storage system comprised of a tank and associated balance of plant (piping, coolant tubes, burner) was performed to determine the usable hydrogen capacity. A composite storage material comprised of a metal hydride mixed with a high thermal-conductivity carbon is predicted to have a usable hydrogen volumetric capacity comparable to or exceeding that of 700 bar pressurized hydrogen gas. The gravimetric capacity of this material is also predicted to be competitive with pressurized gas, particularly if costly carbon fiber composite Type III or Type IV tanks are excluded. The storage system design parameters and material properties served as inputs to a second model that simulates fuel cell operation in conjunction with the storage system during an HDV drive cycle. The results show that sufficient hydrogen pressure can be produced to operate a Class 8 HDV, yielding a range of ~480 miles. These results are particularly relevant for high-impact regions, such as the South Coast Air Quality Management District, for which an economical vehicular hydrogen storage system with minimal impact on cargo capacity could accelerate adoption of heavy-duty fuel cell electric vehicles. An additional benefit is that knowledge generated by this project can assist in development of material-based storage for stationary applications such as microgrids and backup power for data centers.

08 HYDROGEN↗

Impact of Storage Dispatch Assumptions on Resource Adequacy and Capacity Credit

Representing energy-limited resources in power system probabilistic resource adequacy assessment introduces new considerations that invalidate classical modeling assumptions. In particular, such resources have multi-period operating objectives and constraints that in real systems are addressed via a sequence of rolling intertemporal optimizations. Ideally, adequacy models would develop dispatch decisions by solving a similar sequence of problems, but this approach has historically been too computationally intensive for practical use in Monte Carlo simulations, with studies making use of simplifying approximations instead. These simplifications have the potential to distort the assessed value of energy-limited resources on the system.This work describes three classes of storage dispatch assumptions in current use and discusses their theoretical differences. It then provides an empirical analysis of their differences on test systems with different levels of storage, assessing the potential for a study's modeling assumptions to influence the perceived contribution of energy-limited resources.

capacity credit↗

Battery Energy Storage System Evaluation Method

This report describes development of an effort to assess Battery Energy Storage System (BESS) performance that the US DOE Federal Energy Management Program (FEMP) and others can employ to evaluate performance of deployed BESS or solar photovoltaic (PV) +BESS systems. The proposed method is based on actual battery charge and discharge metered data to be collected from BESS systems provided by federal agencies participating in the FEMP's performance assessment initiatives. Long-term (e.g., at least one year) time series (e.g., hourly) charge and discharge data are analyzed to provide approximate estimates of key performance indicators (KPIs).

25 ENERGY STORAGE↗

Advanced sensors and instrumentation

NASA is currently investigating the readiness of Advanced Sensors and Instrumentation to meet the requirements of new initiatives in space. The following technical objectives and technologies are briefly discussed: smart and nonintrusive sensors; onboard signal and data processing; high capacity and rate adaptive data acquisition systems; onboard computing; high capacity and rate onboard storage; efficient onboard data distribution; high capacity telemetry; ground and flight test support instrumentation; power distribution; and workstations, video/lighting. The requirements for high fidelity data (accuracy, frequency, quantity, spatial resolution) in hostile environments will continue to push the technology developers and users to extend the performance of their products and to develop new generations.

Calloway, Raymond S.↗

Two-electron redox active molecules with high capacity and energy density for energy storage applications

A non-aqueous redox flow battery includes a catholyte including a compound of formula (I): wherein E1 and E2 are independently O, S, S═O, S(═O)2, Se, NR11, or PR11; The compounds of the present technology are capable of undergoing a reversible two-electron transfer process, thus leading to high efficiency of molecular design and an increase in the overall energy density.

Huang, Jinhua↗

Impacts of hybridization and forecast errors on the probabilistic capacity credit of batteries

Battery storage is increasingly identified as being among the least-cost mix of technologies in the evolving U.S. electricity mix. This study explores the marginal capacity credit of batteries using a probabilistic, reliability-based, effective firm capacity method, which we apply for multiple battery power ratings, durations, coupling types, deployment locations, and dispatch profiles within a test system that is based on the Texas Interconnection in the year 2024. We find that the capacity credits for all battery durations depend on their ability to predict the timing of reliability events. Even 1-2 h forecast errors - resulting in early or delayed battery discharging relative to the onset of a reliability event - lead pronounced capacity credit reductions, especially for 4-h duration batteries. Coupling batteries with solar mitigates the uncertainty associated with a shorter-duration battery's availability during reliability events, primarily due to the relatively high solar capacity credit in our test system. Coupled (or hybrid) system designs with oversized solar arrays, the ability to charge the coupled battery with grid energy, and larger batteries lead to the greatest capacity credit benefits of hybridization. We do not see evidence that the hybrid capacity credit exceeds the sum of the separate battery and solar capacity credits.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Emerging concepts in intermediate carbon dioxide emplacement to support carbon dioxide removal

Substantial upscaling of carbon dioxide capture is possible in the coming decades but existing solutions for storage are projected to be limited in annual capacity by as much as 2–10 GtCO 2 per year until mid-century. Temporary storage of CO 2 in a solid or liquid state could prove useful for filling this gap in capacity, until more permanent and ideally lucrative CO 2 sequestration options come online. There are several concepts for reversible solid-state and chemical CO 2 storage, but their advantages and limitations have yet to be reviewed in this context. This article focuses on the physical and chemical aspects of CO 2 storage via liquid and solid chemical carriers and sorbents, and gives an overview of the energetics around their use, as well as prospects for their future development. Exciting opportunities for coupling capture and medium to high maturity multi-year storage technologies could support carbon removal in the coming decades. Highlights of the analysis are the remarkable storage capacity of oxalic acid and formic acid (CO 2 -density of 1857 kg m –3 and 1152 kg m –3 , compared with condensed liquid CO 2 at 993–1096 kg m –3 , respectively), the relative scalability and compatibility of carbonate salts for stationary storage with direct air capture, and the potential promise of multiple carriers for CO 2 transportation. Solid sorbents do not achieve such ultra-high storage capacities, but could improve storage over compressed gas tanks on a capacity and energetics basis.

54 ENVIRONMENTAL SCIENCES↗

Metal–Organic Framework Based Hydrogen-Bonding Nanotrap for Efficient Acetylene Storage and Separation

The removal of carbon dioxide (CO 2 ) from acetylene (C 2 H 2 ) is a critical industrial process for manufacturing high purity C 2 H 2 . However, it remains challenging to address the trade-off between adsorption capacity and selectivity, on account of their similar physical properties and molecular sizes. To overcome this difficulty, here we report a novel strategy involving the regulation of hydrogen-bonding nanotrap on the pore surface to promote the separation of C 2 H 2 /CO 2 mixtures, in three isostructural metal-organic frameworks (MOFs, named as MIL-160, CAU-10H, and CAU-23, respectively). Among them, MIL-160, which has abundant hydrogen-bonding acceptors as nanotraps, can selectively capture acetylene molecules and demonstrates ultra-high C 2 H 2 storage capacity (191 cm 3 g –1 , or 213 cm 3 cm –3 ) but much less CO 2 uptake (90 cm 3 g –1 ) under ambient conditions. The C 2 H 2 adsorption amount of MIL-160 is remarkably higher than the other two isostructural MOFs (86 cm 3 g –1 and 119 cm 3 g –1 for CAU-10H and CAU-23 respectively) under the same conditions. More importantly, both simulation and experimental breakthrough results show that MIL-160 sets a new benchmark for equimolar C 2 H 2 /CO 2 separation in terms of the separation potential (Δq break = 5.02 mol/kg) and C 2 H 2 productivity (6.8 mol/kg). In addition, in-situ FT-IR experiments combined with computational modeling further reveal that the unique host-guest multiple hydrogen-bonding interactions between the nanotrap and C 2 H 2 is the key factor for achieving extraordinary acetylene storage capacity and superior C 2 H 2 /CO 2 selectivity. Furthermore, this work provides a novel and powerful approach to address the trade-off of this extremely challenging gas separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

American-Made Challenges Round 2 Voucher: Orison Enables Solar

This report documents the technical assistance provided to Orison as part of the American-Made Challenges Round 2 Voucher: Orison Enables Solar project. A testbed was developed and used to demonstrate, using modeling and simulation, the capability of controlled behind-the-meter energy storage to (1) reduce net load variability caused by appliances and distributed generation and (2) enable customers to respond to the time-of-use pricing. We demonstrate that load leveling can shave peak loads or limit solar photovoltaic export and that load shifting enables customers to reduce load during “peak” pricing intervals. In the scenarios that we simulated, load leveling was effective up to the charging and discharging limits of the storage systems and the effectiveness of load shifting was a function of the energy capacity of the storage systems. This report describes the co-simulation testbed and the scenarios simulated, including controller setup and simulation results. Considerations for a multi-objective controller are also discussed.

14 SOLAR ENERGY↗

Capacity Expansion Planning for LA Basin: the Role of Energy Storage

The paper evaluates the deployment of energy storage to support equitable energy outcomes and the clean energy transition in the Los Angeles Basin (LAB). The deployment of energy storage is considered in a 10 zone capacity expansion planning model from 2022-2045. The model is based on the California Public Utility Commission’s 7 zone RESOLVE model but has been modified to give greater spatial granularity in the LAB area by addig 3 new zones representing the Eastern Los Angeles, Western Los Angeles and the El Nido subzones. Three different scenarios are studied in this work; a base case with no natural gas retirements in the LAB, and two cases exploring extreme natural gas retirements, where the 8GW of natural gas belonging to the LAB are retired by 2045. Study results indicate that storage can play a significant role in helping the LAB meeting its energy requirements. However, when considering extreme retirement scenarios, either new generation (such as solar) or capacity (such as new import capacity via transmission lines) will likely be needed to serve projected system loads.

Maloney, Patrick R.↗

How Today's Hydropower Impacts Tomorrow's Grid: Counterfactual Scenarios Showing Grid Impacts if Hydropower Goes Away

Amidst ongoing discussions about hydropower removals, retirements, and reduced availability due to drought and other environmental considerations, it is important to understand the long-term effects of reduced hydropower resources on the U.S. electric grid. This analysis uses the Regional Energy Deployment System (ReEDS™) grid planning model to compare several representative scenarios of retiring hydropower and pumped storage hydropower (PSH) capacity over time and explore the overall implications on the U.S. grid from present day through 2050. Reduced hydropower capacity and generation is replaced by a mix of both fossil and non-fossil resources, including natural gas, wind, solar, and battery technologies. Additional natural gas usage leads to an increase in cumulative national electric sector carbon dioxide and criteria pollutant operating emissions of less than 1% in many scenarios but up to 4-5.3% in some cases. Total electric sector costs also increase by <1% in many scenarios but up to 3.6% in the most extreme scenarios where nearly all the hydropower and PSH fleet retires, equating to $\$$340 billion in undiscounted costs. National results indicate that absent additional interventions, retiring hydropower and PSH capacity could increase electric sector emissions and direct capital and operating costs. However, more focused analysis is required to evaluate specific asset-level, local, and regional implications, and a broader scope is necessary to weigh these electric sector impacts alongside economic, ecological, water management, and other cross-sectoral effects that could be either negative or positive.

14 SOLAR ENERGY↗

Holographic data storage crystals for LDEF (A0044)

Electro-optic holographic recording systems were developed. The spaceworthiness of electro-optic crystals for use in ultrahigh capacity space data storage and retrieval systems are examined. The crystals for this experiment are included with the various electro-optical components of LDEF experiment. The effects of long-duration exposure on active optical system components is investigated. The concept of data storage in an optical-phase holographic memory is illustrated.

Callen, W. R.↗

Zero Boil Off Cryogen Storage for Future Launchers

Zero boil off (ZBO) cryogen storage using both cryocoolers and passive insulation technologies will enable long-term exploration missions by allowing designers to optimize tankage without the need for excess cryogen storage to account for boil off. Studies of ZBO (zero boil off) have been on-going in the USA for several years. More recently, a review of the needs of advanced space propulsion took place in Europe. This showed the interest of the European community in cryogenic propulsion for planetary missions as well as the use of liquid hydrogen for large power electric propulsion (manned Mars missions). Although natural boiling could be acceptable for single leg missions, passive insulation techniques yield roughly a I% per month cryogen loss and this would not be cost effective for robotic planetary missions involving storage times greater than one year. To make economic sense, long-term exploration missions require lower tank capacity and longer storage times. Recent advances in cryocooler technology, resulting in vast improvements in both cooler efficiency and reliability, make ZBO is a clear choice for planetary exploration missions. Other, more near term applications of ZBO include boil-off reduction or elimination applied to first and upper stages of future earth-to-orbit (ETO) launchers. This would extend launch windows and reduce infrastructure costs. Successors to vehicles like Ariane 5 could greatly benefit by implementing ZBO. Zero Boil Off will only be successful in ETO launcher applications if it makes economic sense to implement. The energy cost is only a fraction of the total cost of buying liquid cryogen, the rest being transportation and other overhead. Because of this, higher boiling point cryogens will benefit more from on-board liquefaction, thus reducing the infrastructure costs. Since hydrogen requires a liquefier with at least a 17% efficiency just to break even from a cost standpoint, one approach for implementing ZBO in upper stages would be to actively cool the shield in the hydrogen tank to reduce the parasitic losses. This would allow the use of less expensive, presently available coolers (80 K vs. 20 K) and potentially simplify the system by requiring only a single compressor on the pad amd a single disconnect line. The compressor could be a hefty commercial unit, with only the cold head requiring expensive flight development and qualification. While this is actually a reduced boil off configuration rather than a zero-boil off case, if the cryogen loss could be cut significantly, the increase in hold time and reduced need for draining and refilling the propellant tanks could meet the vehicle operations needs in the majority of instances.Bearing in mind the potential benefits of ZBO, NASA AMES and SNECMA Moteurs decided to exchange their technical views on the subject. This paper will present a preliminary analysis for a multi-mission module using a fairly low thrust cryogenic engine and ZBO during cruise. Initial mass is 5.5. tons (in ETO). The cryogenic engine will be used near each periapsis in order to minimize the AV requirement. The payload obtained by this propulsion system is compared to a classical storable bipropellant propulsion system for several cases (e. g. Mars lander, Jupiter orbiter, Saturn orbiter). For the Jupiter and Saturn cases, the power source could be an RTG or a large parabolic mirror illuminating a solar panel. It is shown -that - due to its much larger specific impulse - the cryogenic ZBO solution provides much higher payloads, especially for exploration missions involving landing on planets, asteroids, comets, or other celestial bodies.

Valentian, D.↗

Solar and Storage Integration in the Southeastern United States: Economics, Reliability, and Operations

Solar energy has the potential to be a core energy resource for the southeastern United States. To better understand the implications of higher levels of solar PV (27%-43% of total generation capacity) and electricity storage (13%-49% of peak load) would affect electricity system reliability, costs, and operations in the U.S. Southeast, this study sought to address two main questions. First, how would higher levels of solar PV and electricity storage impact the costs, reliability, and operations of electricity systems in the Southeast in 2035? Second, at different levels of solar PV and electricity storage, what are the benefits of operational coordination among utilities in the Southeast, through more efficient regional dispatch and sharing operating reserves? To answer these questions, the study used detailed capacity expansion and dispatch modeling to develop and examine 15 scenarios with different levels of solar PV, electricity storage, and operational coordination, focusing on the year 2035. The study also evaluates the benefits of operational coordination among utilities through more efficient regional dispatch and reserve sharing, at different levels of solar and storage. The study focuses on five balancing regions that cover Alabama, Georgia, Kentucky, North Carolina, South Carolina, Tennessee, and parts of Mississippi and Missouri.

14 SOLAR ENERGY↗

Solar and Storage Integration in the Southeastern United States: Economics, Reliability, and Operations

Solar energy has the potential to be a core energy resource for the southeastern United States. To better understand the implications of higher levels of solar PV (27%-43% of total generation capacity) and electricity storage (13%-49% of peak load) would affect electricity system reliability, costs, and operations in the U.S. Southeast, this study sought to address two main questions. First, how would higher levels of solar PV and electricity storage impact the costs, reliability, and operations of electricity systems in the Southeast in 2035? Second, at different levels of solar PV and electricity storage, what are the benefits of operational coordination among utilities in the Southeast, through more efficient regional dispatch and sharing operating reserves? To answer these questions, the study used detailed capacity expansion and dispatch modeling to develop and examine 15 scenarios with different levels of solar PV, electricity storage, and operational coordination, focusing on the year 2035. The study also evaluates the benefits of operational coordination among utilities through more efficient regional dispatch and reserve sharing, at different levels of solar and storage. The study focuses on five balancing regions that cover Alabama, Georgia, Kentucky, North Carolina, South Carolina, Tennessee, and parts of Mississippi and Missouri.

14 SOLAR ENERGY↗

Front-End Engineering Design for Piperazine with the Advanced Stripper

This Department of Energy (DOE) funded project was executed with the goal of preparing a Front-End Engineering Design (FEED) for the capture and compression of 90% of the CO2 that would normally be emitted from an existing natural gas combined cycle (NGCC) plant. The FEED focused on the application of the piperazine advanced stripper (PZAS) process at Mustang Station of the Golden Spread Electric Cooperative (GSEC), which consists of two gas turbines with common heat recovery steam generator (HRSG). The University of Texas at Austin (UT) served as the prime contractor, and subcontracted AECOM Technical Services and Trimeric Corporation to support FEED development. This project team has worked together to advance PZAS for more than a decade. ExxonMobil, Chevron, and Total provided project co-funding. The objectives of this work included: 1. To advance engineering design such that a comprehensive estimate for the total installed cost of a full-scale PZAS CO2 Capture Plant with CO2 compression can be developed on an existing NGCC power plant. a. These detailed costs can also be used to qualify PZAS and other related second generation (2G) amine scrubbing processes for use on cogeneration facilities in refineries and chemical plants that use gas turbines with HRSGs to produce steam. b. These detailed costs will help qualify 2G amine scrubbing for use on NGCC power plants and establish a more accurate baseline cost to be used as a target by other capture technologies. 2. To provide cost details to be used in the economic optimization of the process features of PZAS and other 2G amine scrubbing processes. 3. To provide DOE with a more detailed understanding of carbon capture costs in a commercial application, enabling DOE to better design its R&D program to improve the economics for carbon capture. 4. To provide the host site and cost share partners with the information necessary to determine whether a commercial project to capture and use CO2 for enhanced oil recovery (EOR) or for sequestration can be justified (when accounting for the 45Q tax credit). A key component of the FEED is the estimated total installed cost, which provides a basis for the likely capital investment necessary to implement the PZAS carbon capture process at this location and scale. In combination with the included economic analysis, which accounts for potential revenue from the produced CO2, potential avenues to profitability are explored. The major findings of the FEED are as follows: The Mustang Station PZAS CO2 Capture Plant estimated total project cost of $698 MM of which $384 MM was direct costs. The annual operating costs were $32.6 MM. The total investment for a PZAS facility at Mustang Station is $725 MM. This estimate includes owner’s cost of $25 million and a contingency of $110 MM. • The study estimated the CO2 capture plant at Mustang Station would generate CO2 at $110/tonne for EOR, assuming a 12% IRR (internal rate of return) and an 85% capacity factor. For CO2 storage, the same case would achieve a 12% IRR at about $114/tonne. At a capacity factor of 52%, the storage and EOR cases would break even when carbon is priced ~$150/tonne. The economic analysis determined that the capacity factor and utility pricing, among other variable factors, had a significant effect on the economics and will need additional studied. • The energy penalty of the PZAS plant would be about 46 MW in connected power and 35 MW in operating load. The natural gas requirement (for the Gas Boiler package) would be about 354 MMBTU/hr. • The FEED revealed no major risks in process maturity. However, some areas were outlined for further engineering during detailed design, which included the Gas Boiler system, general arrangement and site layout, air coolers, schedule development, and optimization of the process for higher CO2 removal. • If PZAS were to be implemented at another host site, additional opportunities for cost reduction for would include cost reduction through use of cooling water and steam extraction.

03 NATURAL GAS↗

Techno-economic Analysis of the Cryogenic Flux Capacitor Compared to Other forms of Hydrogen Production and Storage

The Cryogenic Flux Capacitor (CFC) is a cold, dense energy storage core that is being studied in the cryo-compressed, about 300 bar and 80K, region of gaseous hydrogen (GH2) storage and liquid hydrogen (LH2) region near the normal boiling point. The hydrogens storage is improved by physically bonding the molecules within the nanoscale pores of the aerogel composite blanket material. The process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (~1,000 m2/g) allows its storage performance to easily exceed capacities of high-pressure GH2 storage for an equivalent volume. With the integrated aerogel, subscale tests have shown that storage is increased by about 49% over a simple tank filled with GH2 at the same operating temperature and pressure. For LH2 conditions, the CFC is shown to operate at equivalent densities. For the techno-economic analysis (TEA), the source of hydrogen is compared between onsite steam methane reforming (SMR) and onsite solar photovoltaic (PV) panels providing power to electrolyzers to produce GH2. The TEA compares pure hydrogen burning in a combined cycle gas turbine (CCGT) to hydrogen fuel cells with an overall net power output of 650 MW. The SMR system uses natural gas as an input and includes a carbon capture and storage (CCS) system. The levelized cost of electricity is developed based on the capital cost and operating cost of the systems. Sensitivities are discussed around the cost of natural gas, ranging from 1.93 USD per MMBTU to 6.75 USD per MMBTU, and carbon dioxide disposal, ranging from 7 USD per tonne to 10 USD per tonne. For comparison to the conventional CCGT baseline, a baseload scenario is adopted with 85% capacity factor. The results of the study show that onsite hydrogen generation from SMR is about 1 to 3 USD per kg over the life of the plant and the PV hydrogen production produces at 4 to 5 USD per kg. The cost of storage for CFC is compared to other systems, including high-pressure GH2 and atmospheric LH2. The system is shown to provide the lowest costs for all these options at the grid scale, due to its higher capacity than high-pressure GH2 and ability to operate at 80K, receiving refrigeration from liquid nitrogen systems reducing capital and operating costs when compared LH2 storage systems. SMR is competitive with CCGT at the gas prices, both of which have lower LCOE than the PV system. When accounting for variability in gas prices, the PV and electrolyzer system is less sensitive to these changes and provides the lowest LCOE across the whole range.

08 HYDROGEN↗