Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Statistical techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

PSF and MTF Measurement Methods for Thick CCD Sensor Characterization

Knowledge of the point spread function (PSF) of the sensors to be used in the Large Synoptic Survey Telescope (LSST) camera is essential for optimal extraction of subtle galaxy shape distortions caused by gravitational weak lensing. We have developed a number of techniques for measuring the PSF of candidate CCD sensors to be used in the LSST camera, each with its own strengths and weaknesses. The two main optical PSF measurement techniques that we use are the direct Virtual Knife Edge (VKE) scan as developed by Karcher, et al. and the indirect interference fringe method after Andersen and Sorensen that measures the modulation transfer function (MTF) directly. The PSF is derived from the MTF by Fourier transform. Other non-optical PSF measurement techniques that we employ include {sup 55}Fe x-ray cluster image size measurements and statistical distribution analysis, and cosmic ray muon track size measurements, but are not addressed here. The VKE technique utilizes a diffraction-limited spot produced by a Point-Projection Microscope (PPM) that is scanned across the sensor with sub-pixel resolution. This technique closely simulates the actual operating condition of the sensor in the telescope with the source spot size having an f/number close to the actual telescope design value. The interference fringe method uses a simple equal-optical-path Michelson-type interferometer with a single-mode fiber source that produces interference fringes with 100% contrast over a wide spatial frequency range sufficient to measure the MTF of the sensor directly. The merits of each measurement technique and results from the various measurement techniques on prototype LSST sensors are presented and compared.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Turbulence driven by precession in spherical and slightly elongated spheroidal cavities

Motivated by the fascinating fact that strong turbulence can be sustained in a weakly precessing container, we conducted a series of laboratory experiments on the flow in a precessing spherical cavity, and in a slightly elongated prolate spheroidal cavity with a minor-to-major axis ratio of 0.9. In order to determine the conditions required to sustain turbulence in these cavities, and to investigate the statistics of the sustained turbulence, we developed an experimental technique to conduct high-quality flow visualizations as well as measurements via particle image velocimetry on a turntable and by using an intense laser. In general, flows in a precessing cavity are controlled by two non-dimensional parameters: the Reynolds number Re (or its reciprocal, the Ekman number) which is defined by the cavity size, spin angular velocity, and the kinematic viscosity of the confined fluid, and the Poincaré number Po, which is defined by the ratio of the magnitude of the precession angular velocity to that of the spin angular velocity. However, our experiments show that the global flow statistics, such as the mean velocity field and the spatial distribution of the intensity of the turbulence, are almost independent of Re, and they are determined predominantly by Po, whereas the instability of these global flow structures is governed by Re. It is also shown that the turbulence statistics are most likely similar in the two cavities due to the slight difference between their shapes. However, the condition to sustain the unsteady flows, and therefore the turbulence, differs drastically depending on the cavity shape. Interestingly, the asymmetric cavity, i.e., the spheroid, requires a much stronger precession than a sphere to sustain such unsteady flows. The most developed turbulence for a given Re is generated in these cavities when 0.04 ≲ Po ≲ 0.1. In such cases, the sustained turbulence is always accompanied by vigorous large-scale vortical structures, and shearing motions around these large-scale vortices create smaller-scale turbulent vortices. The spatial average of the Taylor-length based Reynolds number of the turbulence in the precessing sphere is about 0.15√(Re) for Po = 0.1.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Retrieving fields from proton radiography without source profiles

Proton radiography is a technique in high-energy density science to diagnose magnetic and/or electric fields in a plasma by firing a proton beam and detecting its modulated intensity profile on a screen. Current approaches to retrieve the integrated field from the modulated intensity profile require the unmodulated beam intensity profile before the interaction, which is rarely available experimentally due to shot-to-shot variability. In this paper, we present a statistical method to retrieve the integrated field without needing to know the exact source profile. We apply our method to experimental data, showing the robustness of our approach. Furthermore, our proposed technique allows for the retrieval not only of the path-integrated fields, but also of the statistical properties of the fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Flotation by Selected Depressants as an Efficient Technique for Separation of a Mixed Acrylonitrile Butadiene Styrene, Polycarbonate and Polyoxymethyleneplastics in Waste Streams

The virgin acrylonitrile butadiene styrene (ABS), polycarbonate (PC) and polyoxy methylene (POM) available in a plastic mix were separated from each other by a flotation technique with the aid of several depressants. Also, a Design-Expert® statistical software was used to predict plastics flotation using input data including conditioning time, flotation tank temperature and pH and depressants concentration. It revealed that the flotation technique was effective for separation of studied plastics by selected depressants. Understanding the adsorption–desorption phenomena and effective parameters on this process was crucial to explain the activity and selectivity of a depressant on a plastic surface. The increasing conditioning time up to 15 min had adverse effect on the floatability of the all studied plastics conditioned with tannic acid (TA). TA and methyl isobutyl carbinol (MIBC) had not any effect on floatability of PC and POM in all studied depressant concentrations. The flotation of ABS reached to 85% for flotation tank pH of 6.5 with 15 min depressant conditioning at 35 °C as flotation tank temperature. A complicate phenomenon involved and predominated in flotation of studied plastics. Proposed equations by Design-Expert® predicted close plastic flotation values when compared with corresponding experimental values.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reduced Dynamics of Full Counting Statistics

We present a theory of modified reduced dynamics in the presence of counting fields. Reduced dynamics techniques are useful for describing open quantum systems at long emergent timescales when the memory timescales are short. However, they can be difficult to formulate for observables spanning the system and its environment, such as those characterizing transport properties. A large variety of mixed system--environment observables, as well as their statistical properties, can be evaluated by considering counting fields. Given a numerical method able to simulate the field-modified dynamics over the memory timescale, we show that the long-lived full counting statistics can be efficiently obtained from the reduced dynamics. We demonstrate the utility of the technique by computing the long-time current in the nonequilibrium Anderson impurity model from short-time Monte Carlo simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Techniques for Analyzing Lens Manufacturing Data with Optical Design Applications

Optical designers assume a mathematically derived statistical distribution of the relevant design parameters for their Monte Carlo tolerancing simulations. However, there may be significant differences between the assumed distributions and the likely outcomes from manufacturing. Of particular interest for this study are the data analysis techniques and how they may be applied to optical and mechanical tolerance decisions. The effect of geometric factors and mechanical glass properties on lens manufacturability will be also be presented. Although the present work concerns lens grinding and polishing, some of the concepts and analysis techniques could also be applied to other processes such molding and single-point diamond turning.

optical design, statistics, optomechanical, manufa↗

Testing convolutional neural network based deep learning systems: a statistical metamorphic approach

Machine learning technology spans many areas and today plays a significant role in addressing a wide range of problems in critical domains,i.e., healthcare, autonomous driving, finance, manufacturing, cybersecurity,etc. Metamorphic testing (MT) is considered a simple but very powerful approach in testing such computationally complex systems for which either an oracle is not available or is available but difficult to apply. Conventional metamorphic testing techniques have certain limitations in verifying deep learning-based models (i.e., convolutional neural networks (CNNs)) that have a stochastic nature (because of randomly initializing the network weights) in their training. In this article, we attempt to address this problem by using a statistical metamorphic testing (SMT) technique that does not require software testers to worry about fixing the random seeds (to get deterministic results) to verify the metamorphic relations (MRs). We propose seven MRs combined with different statistical methods to statistically verify whether the program under test adheres to the relation(s) specified in the MR(s). We further use mutation testing techniques to show the usefulness of the proposed approach in the healthcare space and test two CNN-based deep learning models (used for pneumonia detection among patients). The empirical results show that our proposed approach uncovers 85.71% of the implementation faults in the classifiers under test (CUT). Furthermore, we also propose an MRs minimization algorithm for the CUT, thus saving computational costs and organizational testing resources.

Computer Science↗

Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control

Purpose: High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process control tools, was developed. The MLC performance monitoring system was used for almost a year on two commercially available MLC models. Control charts were used to establish MLC performance and assess test frequency required to achieve a given level of performance. MLC-related interlocks and servicing events were recorded during the monitoring period and were investigated as indicators of MLC performance variations. Methods: The QC test developed as part of the MLC performance monitoring system uses 2D megavoltage images (acquired using an electronic portal imaging device) of 23 fields to determine the location of the leaves with respect to the radiation isocenter. The precision of the MLC performance monitoring QC test and the MLC itself was assessed by detecting the MLC leaf positions on 127 megavoltage images of a static field. After initial calibration, the MLC performance monitoring QC test was performed 3–4 times/week over a period of 10–11 months to monitor positional accuracy of individual leaves for two different MLC models. Analysis of test results was performed using individuals control charts per leaf with control limits computed based on the measurements as well as two sets of specifications of ±0.5 and ±1 mm. Out-of-specification and out-of-control leaves were automatically flagged by the monitoring system and reviewed monthly by physicists. MLC-related interlocks reported by the linear accelerator and servicing events were recorded to help identify potential causes of nonrandom MLC leaf positioning variations. Results: The precision of the MLC performance monitoring QC test and the MLC itself was within ±0.22 mm for most MLC leaves and the majority of the apparent leaf motion was attributed to beam spot displacements between irradiations. The MLC QC test was performed 193 and 162 times over the monitoring period for the studied units and recalibration had to be repeated up to three times on one of these units. For both units, rate of MLC interlocks was moderately associated with MLC servicing events. The strongest association with the MLC performance was observed between the MLC servicing events and the total number of out-of-control leaves. The average elapsed time for which the number of out-of-specification or out-of-control leaves was within a given performance threshold was computed and used to assess adequacy of MLC test frequency. Conclusions: A MLC performance monitoring system has been developed and implemented to acquire high-quality QC data at high frequency. This is enabled by the relatively short acquisition time for the images and automatic image analysis. The monitoring system was also used to record and track the rate of MLC-related interlocks and servicing events. MLC performances for two commercially available MLC models have been assessed and the results support monthly test frequency for widely accepted ±1 mm specifications. Higher QC test frequency is however required to maintain tighter specification and in-control behavior.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-309: Dosimetric Comparison of Simultaneous Integrated Boost Treatment Plan Between Intensity Modulated Radiotherapies (IMRTs), Dual Arc Volumetric Modulated Arc Therapy (DA-VMAT) and Single Arc Volumetric Modulated Arc Therapy (SA-VMAT) for Nasopharyngeal Carcinoma (NPC)

Purpose: To compare the plan quality and performance of Simultaneous Integrated Boost (SIB) Treatment plan between Seven field (7F) and Nine field(9F) Intensity Modulated Radiotherapies and Single Arc (SA) and Dual Arc (DA) Volumetric Modulated Arc Therapy( VMAT). Methods: Retrospective planning study of 16 patients treated in Elekta Synergy Platform (mlci2) by 9F-IMRT were replanned with 7F-IMRT, Single Arc VMAT and Dual Arc VMAT using CMS, Monaco Treatment Planning System (TPS) with Monte Carlo simulation. Target delineation done as per Radiation Therapy Oncology Protocols (RTOG 0225&0615). Dose Prescribed as 70Gy to Planning Target Volumes (PTV70) and 61Gy to PTV61 in 33 fraction as a SIB technique. Conformity Index(CI), Homogeneity Index(HI) were used as analysis parameter for Target Volumes as well as Mean dose and Max dose for Organ at Risk(OAR,s).Treatment Delivery Time(min), Monitor unit per fraction (MU/fraction), Patient specific quality assurance were also analysed. Results: A Poor dose coverage and Conformity index (CI) was observed in PTV70 by 7F-IMRT among other techniques. SA-VMAT achieved poor dose coverage in PTV61. No statistical significance difference observed in OAR,s except Spinal cord (P= 0.03) and Right optic nerve (P=0.03). DA-VMAT achieved superior target coverage, higher CI (P =0.02) and Better HI (P=0.03) for PTV70 other techniques (7F-IMRT/9F-IMRT/SA-VMAT). A better dose spare for Parotid glands and spinal cord were seen in DA-VMAT. The average treatment delivery time were 5.82mins, 6.72mins, 3.24mins, 4.3mins for 7F-IMRT, 9F-IMRT, SA-VMAT and DA-VMAT respectively. Significance difference Observed in MU/fr (P <0.001) and Patient quality assurance pass rate were >95% (Gamma analysis (Γ3mm, 3%). Conclusion: DA-VAMT showed better target dose coverage and achieved better or equal performance in sparing OARs among other techniques. SA-VMAT offered least Treatment Time than other techniques but achieved poor target coverage. DA-VMAT offered shorter delivery time than 7F-IMRT and 9F-IMRT without compromising the plan quality.

60 APPLIED LIFE SCIENCES↗

SU-F-T-272: Patient Specific Quality Assurance of Prostate VMAT Plans with Portal Dosimetry

Purpose: To evaluate the effectiveness of using the Portal Dosimetry (PD) method for patient specific quality assurance of prostate VMAT plans. Methods: As per institutional protocol all VMAT plans were measured using the Varian Portal Dosimetry (PD) method. A gamma evaluation criterion of 3%-3mm with a minimum area gamma pass rate (gamma <1) of 95% is used clinically for all plans. We retrospectively evaluated the portal dosimetry results for 170 prostate patients treated with VMAT technique. Three sets of criterions were adopted for re-evaluating the measurements; 3%-3mm, 2%-2mm and 1%-1mm. For all criterions two areas, Field+1cm and MLC-CIAO were analysed.To ascertain the effectiveness of the portal dosimetry technique in determining the delivery accuracy of prostate VMAT plans, 10 patients previously measured with portal dosimetry, were randomly selected and their measurements repeated using the ArcCHECK method. The same criterion used in the analysis of PD was used for the ArcCHECK measurements. Results: All patient plans reviewed met the institutional criteria for Area Gamma pass rate. Overall, the gamma pass rate (gamma <1) decreases for 3%-3mm, 2%-2mm and 1%-1mm criterion. For each criterion the pass rate was significantly reduced when the MLC-CIAO was used instead of FIELD+1cm. There was noticeable change in sensitivity for MLC-CIAO with 2%-2mm criteria and much more significant reduction at 1%-1mm. Comparable results were obtained for the ArcCHECK measurements. Although differences were observed between the clockwise verses the counter clockwise plans in both the PD and ArcCHECK measurements, this was not deemed to be statistically significant. Conclusion: This work demonstrates that Portal Dosimetry technique can be effectively used for quality assurance of VMAT plans. Results obtained show similar sensitivity compared to ArcCheck. To reveal certain delivery inaccuracies, the use of a combination of criterions may provide an effective way in improving the overall sensitivity of PD. Funding provided in part by the Prostate Ride for Dad, Kitchener-Waterloo, Canada.

60 APPLIED LIFE SCIENCES↗

Assessment of the dose reduction potential of a model-based iterative reconstruction algorithm using a task-based performance metrology

Purpose: Different computed tomography (CT) reconstruction techniques offer different image quality attributes of resolution and noise, challenging the ability to compare their dose reduction potential against each other. The purpose of this study was to evaluate and compare the task-based imaging performance of CT systems to enable the assessment of the dose performance of a model-based iterative reconstruction (MBIR) to that of an adaptive statistical iterative reconstruction (ASIR) and a filtered back projection (FBP) technique. Methods: The ACR CT phantom (model 464) was imaged across a wide range of mA setting on a 64-slice CT scanner (GE Discovery CT750 HD, Waukesha, WI). Based on previous work, the resolution was evaluated in terms of a task-based modulation transfer function (MTF) using a circular-edge technique and images from the contrast inserts located in the ACR phantom. Noise performance was assessed in terms of the noise-power spectrum (NPS) measured from the uniform section of the phantom. The task-based MTF and NPS were combined with a task function to yield a task-based estimate of imaging performance, the detectability index (d′). The detectability index was computed as a function of dose for two imaging tasks corresponding to the detection of a relatively small and a relatively large feature (1.5 and 25 mm, respectively). The performance of MBIR in terms of the d′ was compared with that of ASIR and FBP to assess its dose reduction potential. Results: Results indicated that MBIR exhibits a variability spatial resolution with respect to object contrast and noise while significantly reducing image noise. The NPS measurements for MBIR indicated a noise texture with a low-pass quality compared to the typical midpass noise found in FBP-based CT images. At comparable dose, the d′ for MBIR was higher than those of FBP and ASIR by at least 61% and 19% for the small feature and the large feature tasks, respectively. Compared to FBP and ASIR, MBIR indicated a 46%–84% dose reduction potential, depending on task, without compromising the modeled detection performance. Conclusions: The presented methodology based on ACR phantom measurements extends current possibilities for the assessment of CT image quality under the complex resolution and noise characteristics exhibited with statistical and iterative reconstruction algorithms. The findings further suggest that MBIR can potentially make better use of the projections data to reduce CT dose by approximately a factor of 2. Alternatively, if the dose held unchanged, it can improve image quality by different levels for different tasks.

60 APPLIED LIFE SCIENCES↗

VELOCITY SPECTRUM FOR H I AT HIGH LATITUDES

In this paper, we present the results of the statistical analysis of high-latitude H I turbulence in the Milky Way. We have observed H I in the 21 cm line, obtained with the Arecibo{sup 3} L-Band Feed Array receiver at the Arecibo radio telescope. For recovering velocity statistics, we have used the velocity coordinate spectrum (VCS) technique. In our analysis, we have used direct fitting of the VCS model, as its asymptotic regimes are questionable for Arecibo's resolution, given the restrictions from thermal smoothing of the turbulent line. We have obtained a velocity spectral index of 3.87 {+-} 0.11, an injection scale of 140 {+-} 80 pc, and an H I cold phase temperature of 52 {+-} 11 K. The spectral index is steeper than the Kolmogorov index and can be interpreted as being due to shock-dominated turbulence.

79 ASTRONOMY AND ASTROPHYSICS↗

A Hybrid Semi-supervised Classification Scheme for Mining Multisource Geospatial Data

Supervised learning methods such as Maximum Likelihood (ML) are often used in land cover (thematic) classification of remote sensing imagery. ML classifier relies exclusively on spectral characteristics of thematic classes whose statistical distributions (class conditional probability densities) are often overlapping. The spectral response distributions of thematic classes are dependent on many factors including elevation, soil types, and ecological zones. A second problem with statistical classifiers is the requirement of large number of accurate training samples (10 to 30 |dimensions|), which are often costly and time consuming to acquire over large geographic regions. With the increasing availability of geospatial databases, it is possible to exploit the knowledge derived from these ancillary datasets to improve classification accuracies even when the class distributions are highly overlapping. Likewise newer semi-supervised techniques can be adopted to improve the parameter estimates of statistical model by utilizing a large number of easily available unlabeled training samples. Unfortunately there is no convenient multivariate statistical model that can be employed for mulitsource geospatial databases. In this paper we present a hybrid semi-supervised learning algorithm that effectively exploits freely available unlabeled training samples from multispectral remote sensing images and also incorporates ancillary geospatial databases. We have conducted several experiments on real datasets, and our new hybrid approach shows over 25 to 35% improvement in overall classification accuracy over conventional classification schemes.

54 ENVIRONMENTAL SCIENCES↗

Stochastic density functional theory: Real- and energy-space fragmentation for noise reduction

Stochastic density functional theory (sDFT) is becoming a valuable tool for studying ground-state properties of extended materials. The computational complexity of describing the Kohn-Sham orbitals is replaced by introducing a set of random (stochastic) orbitals leading to linear and often sub-linear scaling of certain ground-state observables at the account of introducing a statistical error. Schemes to reduce the noise are essential, for example, for determining the structure using the forces obtained from sDFT. Recently, we have introduced two embedding schemes to mitigate the statistical fluctuations in the electron density and resultant forces on the nuclei. Both techniques were based on fragmenting the system either in real space or slicing the occupied space into energy windows, allowing for a significant reduction in the statistical fluctuations. For chemical accuracy, further reduction of the noise is required, which could be achieved by increasing the number of stochastic orbitals. However, the convergence is relatively slow as the statistical error scales as 1 / N &#x3C7; according to the central limit theorem, where N χ is the number of random orbitals. In this paper, we combined the embedding schemes mentioned above and introduced a new approach that builds on overlapped fragments and energy windows. The new approach significantly lowers the noise for ground-state properties, such as the electron density, total energy, and forces on the nuclei, as demonstrated for a G-center in bulk silicon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High mass and halo resolution from fast low resolution simulations

Generating mocks for future sky surveys requires large volumes and high resolutions, which is computationally expensive even for fast simulations. Here we try to develop numerical schemes to calibrate various halo and matter statistics in fast low resolution simulations compared to high resolution N-body and hydrodynamic simulations. For the halos, we improve the initial condition resolution and develop a halo finder "relaxed-FoF", where we allow different linking lengths for different halo mass and velocity dispersions. We show that our relaxed-FoF halo finder improves the common statistics, such as halo bias, halo mass function, halo auto power spectrum, cross correlation coefficient with the reference halo catalog, and halo-matter cross power spectrum. We also calibrate small-scale velocities of small halos to improve the power spectrum in redshift space. For the matter statistics, we incorporate the potential gradient descent (PGD) method into fast simulations to improve the matter distribution at nonlinear scales. By building a lightcone output, we show that the PGD method significantly improves the weak lensing convergence tomographic power spectrum. With these improvements FastPM is comparable to the high resolution full N-body simulation of the same mass resolution, with two orders of magnitude fewer time steps. These techniques can be used to improve the halo and matter statistics of FastPM simulations for mock catalogs of future surveys such as DESI and LSST.

79 ASTRONOMY AND ASTROPHYSICS↗

Archaeological applications of laser-induced breakdown spectroscopy: an example from the Coso Volcanic Field, California, using advanced statistical signal processing analysis

Over the past quarter century, multielement chemical analysis has become a common means for attributing the provenance of archaeological materials. The Coso Volcanic Field (CVF) in California, USA, contains at least 38 high-silica rhyolite domes, many of which contain obsidian glass that has been quarried for tools by the indigenous population for more than 12,000 years. Artifacts made from CVF obsidian are found throughout the southwestern United States and geochemical sourcing of CVF obsidian has been an important tool in understanding prehistoric Native American trading patterns. Laser-induced breakdown spectroscopy (LIBS) is a simple atomic emission spectroscopic technique that has the potential for real-time man-portable chemical analysis in the field. Because LIBS is simultaneously sensitive to all elements, a single laser shot can be used to record the broadband emission spectra, which provides a ''chemical fingerprint'' of a material. Single-shot broadband LIBS spectra were collected using a commercial benchtop LIBS system for 27 obsidian samples from major sites across the CVF and four additional sites in California and western Nevada outside of CVF. Classification of the samples was performed using partial least-squares discriminant analysis (PLSDA), a common chemometric technique suitable for performing regression on high-dimensional data. Provenance identification for the obsidian samples was evaluated for three separate labeling frameworks. The first framework consisted of a binary classification problem to distinguish CVF samples from non-CVF samples. The second approach focused on the CVF samples with labels that corresponded to the eight separate Coso sites encompassed by the 27 samples. In the third analysis, non-CVF samples were excluded, and the remaining 27 CVF samples were labeled based on groupings defined from previous major and trace element chemical studies, which reduces the number of possible classes from eight to four. Different aspects of the classifier setup considered in this study include the training/testing routine (a 27-fold leave-one-sample-out setup versus a simple split of the data into separate sets for training and evaluation), the number of latent variables used in the regression model, and whether PLSDA operating on the entire broadband LIBS spectrum is superior to that using only a selected subset of LIBS emission lines. The results point to the robustness of the PLSDA technique and suggest that LIBS analysis combined with the appropriate statistical signal processing has the potential to be a useful tool for chemical analysis of archaeological artifacts and geological specimens.

74 ATOMIC AND MOLECULAR PHYSICS↗

Kinetic theory of particle-in-cell simulation plasma and the ensemble averaging technique

Abstract We derive the kinetic theory of fluctuations in physically and numerically stable particle-in-cell (PIC) simulations of electrostatic plasmas. The starting point is the single-time correlation at the start of the simulation between the statistical fluctuations of the weighted densities of macroparticle centers in the plasma particle phase-space. The fluctuations are associated with different initial conditions, typically due to the random initial conditions (in velocity space) of the macroparticles/simulation plasma, assigned according to their initial distribution of probability. The single-time correlations at all time steps and in each spatial grid cell are then determined from the Laplace–Fourier transforms of the discretized Klimontovich-like equation for the macroparticles and Maxwell’s equations for the fields, as computed by modern PIC codes. We recover the expressions for the electrostatic field and the plasma particle density fluctuation autocorrelation spectra as well as the kinetic equations describing the average evolution of PIC-simulated plasma particles, first derived by Langdon (1970b Proc. 4th Conf. Numerical Simulation of Plasmas ) using a test macroparticle approach perturbing a discretized Vlasovian plasma and then averaging the obtained physical quantity over the initial macroparticle velocity distribution. We generalize and extend these results to the modern algorithms in PIC codes using arbitrary macroparticle weights. Analytical estimates of statistical fluctuation amplitudes are derived as a function of the plasma simulation parameters, using the central limit theorem in the limit of a large number of macroparticles per cell. The theory is then used to analyze the ensemble averaging technique of PIC simulations where statistical averages are performed over ensembles of PIC simulations, modeling the same plasma physics problem but using different statistical realizations of the initial distribution functions of the macroparticles. This method is illustrated by linear Landau damping uncovering (from noise, which is usually considered numerical) the physical fluctuations driven by a single small amplitude electrostatic wave perturbing a PIC simulation plasma in equilibrium.

fluctuations correlations↗

A new method for imaging nuclear threats using cosmic ray muons

Muon tomography is a technique that uses cosmic ray muons to generate three-dimensional images of volumes using information contained in the Coulomb scattering of the muons. Advantages of this technique are the ability of cosmic rays to penetrate significant overburden and the absence of any additional dose delivered to subjects under study beyond the natural cosmic ray flux. Disadvantages include the relatively long exposure times and poor position resolution and complex algorithms needed for reconstruction. Furthermore, we demonstrate a new method for obtaining improved position resolution and statistical precision for objects with spherical symmetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗