Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Specification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Specific heat and gap structure of a nematic superconductor: Application to FeSe

We report the results of our in-depth analysis of spectroscopic and thermodynamic properties of a multiorbital metal, like FeSe, which first develops a nematic order and then undergoes a transition into a superconducting state, which coexists with nematicity. We analyze the angular dependence of the gap function and specific heat C v (T) of such a nematic superconductor. We specifically address three issues: (i) the angular dependence of the gap in light of the competition between the nematicity-induced s - d mixture and the orbital transmutation of low-energy excitations in the nematic state, (ii) the effect of nematicity on the magnitude of the jump of the specific heat C v (T) at T c and the temperature dependence of C v (T) below T c , and (iii) a potential transition at T c1 < T c from an s + d state to an s + e iη d state that breaks time-reversal symmetry. We consider two scenarios for a nematic order: scenario A, in which this order develops between d xz and d yz orbitals on hole and electron pockets, and scenario B, in which there is an additional component of the nematic order for d xy fermions on the two electron pockets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Inversion of specific heat oscillations with in-plane magnetic field angle in two-dimensional $d$-wave superconductors

Experiments on several novel superconducting compounds have observed oscillations of the specific heat when an applied magnetic field is rotated with respect to the crystal axes. The results are commonly interpreted as arising from the nodes of an unconventional order parameter, but the identifications of nodal directions are sometimes controversial. Furthermore we show with a semiclassical model calculation that when the magnetic field points in the direction of the nodes, either minima or maxima can occur in the specific heat depending on the temperature T and the magnetic field H. An inversion of the angular oscillations takes place with respect to those predicted earlier at low temperature by the nodal approximation. This result, together with the argument that the inversion takes place based on an approximation valid at moderate fields, indicates that the inversion of specific heat oscillations is an intrinsic feature of nodal superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ferromagnetic ordering in CeIr 2 B 2 : Transport, magnetization, specific heat, and NMR studies

Here we present a complete characterization of the ferromagnetic system CeIr 2 B 2 using powder x-ray diffraction (XRD), magnetic susceptibility χ(T), isothermal magnetization M(H), specific heat C(T), electrical resistivity ρ(T,H), and thermoelectric power S(T) measurements. Furthermore, 11 B NMR study was performed to probe the magnetism on a microscopic scale. Rietveld refinement of powder XRD data confirms that CeIr 2 B 2 crystallizes in CaRh 2 B 2 -type orthorhombic structure (space group fddd). The χ(T), C(T), and ρ(T) data confirm bulk ferromagnetic ordering with T c =5.1 K. Ce ions in CeIr 2 B 2 are in a stable trivalent state. Our low-temperature C(T) data measured down to 0.4 K yield a Sommerfeld coefficient γ = 73(4) mJ/mol K2, which is much smaller than the previously reported value of γ = 180 mJ/mol K 2 deduced from the specific heat measurement down to 2.5 K. For LaIr 2 B 2 , γ = 6(1) mJ/mol K 2 , which implies the density of states at the Fermi level $\mathscr{D}$(E F )=2.54 states/(eV f.u.) for both spin directions. The renormalization factor for quasiparticle density of states and hence for quasiparticle mass due to 4f correlations in CeIr 2 B 2 is ≈12. The Kondo temperature TK~4 K is estimated from the jump in specific heat of CeIr 2 B 2 at T c . Both C(T) and ρ(T) data exhibit a gapped-magnon behavior in the magnetically ordered state with an energy gap E g ~3.5 K. The ρ data as a function of magnetic field H indicate a large negative magnetoresistance (MR) which is highest for T=5 K. While at 5 K the negative MR keeps on increasing up to 10 T, at 2 K an upturn is observed near H=3.5 T. On the other hand, the thermoelectric power data have small absolute values (S~7μV/K), indicating a weak Kondo interaction. A shoulder in S(T) at about 30 K, followed by a minimum at ~10 K, is attributed to crystal electric field effects and the onset of magnetic ordering. 11 B NMR line broadening provides strong evidence of ferromagnetic correlations below 40 K.

36 MATERIALS SCIENCE↗

Specific heat investigation for line nodes in heavily overdoped Ba 1-x K x Fe 2 As 2

Previous research has found that the pairing symmetry in the iron-based superconductor Ba 1-x K x Fe 2 As 2 changes from nodeless s-wave near optimally doped, x≈0.4-0.55 and T c >30 K, to nodal (either d-wave or s-wave) at the pure endpoint, x=1 and T c <4 K. Intense theoretical interest has been focused on this possibility of changing pairing symmetry, where in the transition region both order parameters would be present and time reversal symmetry would be broken. Here we report specific heat measurements in zero and applied magnetic fields down to 0.4 K of three individual single crystals, free of low temperature magnetic anomalies, of heavily overdoped Ba 1-x K x Fe 2 As 2 , x= 0.91, 0.88, and 0.81. The values for T c mid are 5.6, 7.2 and 13 K and for H c2 ≈ 4.5, 6, and 20 T respectively. Furthermore, the data can be analyzed in a two gap scenario, Δ 2 /Δ 1 ≈ 4, with the magnetic field dependence of γ (=C/T as T→0) showing an anisotropic ‘S-shaped’ behavior vs H, with the suppression of the lower gap by 1 T and γ ≈ H 1/2 overall. Although such a non-linear γ vs H is consistent with deep minima or nodes in the gap structure, it is not clear evidence for one, or both, of the gaps being nodal in these overdoped samples. Thus, following the established theoretical analysis of the specific heat of d-wave cuprate superconductors containing line nodes, we present the specific heat normalized by H 1/2 plotted vs T/H 1/2 of these heavily overdoped Ba 1-x K x Fe 2 As 2 samples which – thanks to the absence of magnetic impurities in our sample - convincingly shows the expected scaling for line node behavior for the larger gap for all three compositions. There is however no clear observation of the nodal behavior C ∝ αT 2 in zero field at low temperatures, with α ≤ 2 mJ/molK 3 being consistent with the data. Together with the scaling, this leaves open the possibility of extreme anisotropy in a nodeless larger gap, Δ 2 , such that the scaling works for fields above 0.25 – 0.5 T (0.2 – 0.4 K in temperature units), where this an estimate for the size of the deep minima in the Δ 2 ~ 20-25 K gap. Furthermore, the location of the change from nodeless→nodal gaps between optimally doped and heavily overdoped Ba 1-x K x Fe 2 As 2 based on the present work may be closer to the KFe 2 As 2 endpoint than x=0.91.

36 MATERIALS SCIENCE↗

Specific heats for quantum BTZ black holes in extended thermodynamics

It was shown recently that extended black hole thermodynamics, where the cosmological constant is a dynamical variable, giving rise to a pressure p and its conjugate volume V , can be given a natural setting in the context of braneworld models. We study the specific heat capacities C p ( T ) and C V ( T ) of the quantum version of the Bañados, Teitelboim, and Zanelli (BTZ) black hole that lives in the induced gravity theory on the brane. There are multiple branches of solutions, and we explore and characterize key features of the possible behavior. We identify and study a critical point in the space of solutions where both specific heats diverge. In the regime of weak backreaction where we are close to an ordinary theory of gravity, the black hole is “subentropic,” but as backreaction is increased we note that there are parts of parameter space that has regions where it is “superentropic.” While a study of the sign of the specific heats does not always show a corresponding instability (conjectured in the literature), the presence of strong backreaction makes interpretation unclear. Published by the American Physical Society 2024

Johnson, Clifford V. (ORCID:0000000189645830)↗

Decoupling Thin Film CdTe Growth from Packaging: Toward Record Specific Power in Low Cost Polycrystalline PV

There are critical material and scientific barriers to producing high efficiency, flexible, lightweight solar cells that maximize specific power in a cost-effective manner. III-V solar cells have produced the highest specific power of any photovoltaic technology due to their extremely high efficiency, however, they are also among the most expensive to produce. This work explores a novel lift-off approach with thin-film solar cells, particularly CdTe, to achieve high specific power at low costs. Thin-film devices can be delaminated from their heavy, glass growth substrates post-growth by exploiting a mismatch in coefficient of thermal expansion between the two. This allows thin-film PV to be decoupled from high temperature growth requirements and repackaged using lightweight materials. In this work we evaluate different materials and approaches for achieving large area delamination of CdTe films from their glass superstrates. It is found that epoxy bonded to a rigid handle provides robust and reproducible delamination at the TCO/CdS interface upon submersion in liquid nitrogen. Following delamination, a transparent front contact is re-deposited and selectively etched to expose the back contact to produce a functioning device. Effects of delamination and contributions to device functionality from CdCl 2 and CdS layers are discussed. Reproducible delamination of high efficiency, thin-film solar cells over large areas will enable work to further improve device efficiency through passivation and reconstruction of the previously buried interface between the transparent contact and CdS.

14 SOLAR ENERGY↗

Structure of NADP + -dependent glutamate dehydrogenase from Escherichia coli - reflections on the basis of coenzyme specificity in the family of glutamate dehydrogenases

Glutamate dehydrogenases catalyse the oxidative deamination of L -glutamate to α-ketoglutarate, using NAD + and/or NADP + as a cofactor. Subunits of homo-hexameric bacterial enzymes comprise a substrate-binding domain I followed by a nucleotide-binding domain II. The reaction occurs in a catalytic cleft between the two domains. Although conserved residues in the nucleotide-binding domains of various dehydrogenases have been linked to cofactor preferences, the structural basis for specificity in the GDH family remains poorly understood. Here, the refined crystal structure of Escherichia coli GDH in the absence of reactants is described at 2.5-Å resolution. Modelling of NADP + in domain II reveals the potential contribution of positively charged residues from a neighbouring α-helical hairpin to phosphate recognition. In addition, a serine that follows the P7 aspartate is presumed to form a hydrogen bond with the 2'-phosphate. Mutagenesis and kinetic analysis confirms the importance of these residues in NADP + recognition. Surprisingly, one of the positively charged residues is conserved in all sequences of NAD + -dependent enzymes, but the conformations adopted by the corresponding regions in proteins whose structure has been solved preclude their contribution to the coordination of the 2'-ribose phosphate of NADP + . These studies clarify the sequence–structure relationships in bacterial GDHs, revealing that identical residues may specify different coenzyme preferences, depending on the structural context. Primary sequence alone is therefore not a reliable guide for predicting coenzyme specificity. We also consider how it is possible for a single sequence to accommodate both coenzymes in the dual-specificity GDHs of animals.

Sharkey, Michael A.↗

Species‐Specific Epigenetic Signature Associates With Heat Stress Tolerance in the Perennial Tree Species Populus

Epigenetic regulation in annual plants is recognized as a key component of recurring stress acclimation and adaptation, but reports on perennial tree species are limited. In this study, two contrasting tree species, Populus trichocarpa and Populus deltoides, and an F1 hybrid cross between them showed species-specific epigenetic and physiological responses to heat stress (42°C) following priming (35°C). By analyzing whole-genome methylation, transcriptomics, proteomics, metabolomics, and photosynthesis parameters, we found that P. deltoides expresses specific epigenetic signatures in response to heat, resulting in improved photosynthetic efficiency compared to P. trichocarpa. Conversely, P. trichocarpa displayed stress signaling and defense mechanisms that could not sustain a net assimilation rate despite maintaining higher gas exchange. Heat stress following priming in hybrid plants increased transcript levels of thermotolerance-related transcription factors, such as SPL12. Selected regions in the promoter of SPL12 showed differential methylation between direct heat stress and priming followed by heat stress. As a result, upregulation of downstream genes and associated increases in protein and metabolite abundance for stress adaptation were exhibited. Consequently, hybrid plants showed enhanced photosynthesis and gas exchange rates, a trait lacking in P. trichocarpa. These results imply that priming may not be universally effective in enhancing plant performance under stress, particularly in perennial tree species. However, priming can acclimate the perennial tree species P. deltoides to withstand elevated temperature stress better. Our study has demonstrated that priming-based stress adaptation is species-specific but can be attained through crossbreeding, indicating its potential use in breeding programs.

DNA methylation↗

Comparative genomics and functional analysis of niche-specific adaptation in Pseudomonas putida

Pseudomonas putida is a gram-negative rod-shaped gammaproteobacterium that is found throughout various environments. Members of the species P. putida show a diverse spectrum of metabolic activities, which is indicative of their adaptation to various niches, which includes the ability to live in soils and sediments contaminated with high concentrations of heavy metals and organic contaminants. Pseudomonas putida strains are also found as plant growth-promoting rhizospheric and endophytic bacteria. The genome sequences of several P. putida species have become available and provide a unique tool to study the specific niche adaptation of the various P. putida strains. In this review, we compare the genomes of four P. putida strains: the rhizospheric strain KT2440, the endophytic strain W619, the aromatic hydrocarbon-degrading strain F1 and the manganese-oxidizing strain GB-1. Comparative genomics provided a powerful tool to gain new insights into the adaptation of P. putida to specific lifestyles and environmental niches, and clearly demonstrated that horizontal gene transfer played a key role in this adaptation process, as many of the niche-specific functions were found to be encoded on clearly defined genomic islands.

54 ENVIRONMENTAL SCIENCES↗

Genetically-determined variations in photosynthesis indicate roles for specific fatty acid species in chilling responses

Using a population of recombinant inbred lines (RILs) cowpea (Vigna unguiculata. L. Walp), we tested for co-linkages between lipid contents and chilling responses of photosynthesis. Under low-temperature conditions (19°C/13°C, day/night), we observed co-linkages between quantitative trait loci intervals for photosynthetic light reactions and specific fatty acids, most strikingly, the thylakoid-specific fatty acid 16:1 Δ3trans found exclusively in phosphatidylglycerol (PG 16:1t). By contrast, we did not observe co-associations with bulk polyunsaturated fatty acids or high-melting-point-PG (sum of PG 16:0, PG 18:0 and PG 16:1t) previously thought to be involved in chilling sensitivity. These results suggest that in cowpea, chilling sensitivity is modulated by specific lipid interactions rather than bulk properties. We were able to recapitulate the predicted impact of PG 16:1t levels on photosynthetic responses at low temperature using mutants and transgenic Arabidopsis lines. Because PG 16:1t synthesis requires the activity of peroxiredoxin-Q, which is activated by H 2 O 2 and known to be involved in redox signalling, here we hypothesise that the accumulation of PG 16:1t occurs as a result of upstream effects on photosynthesis that alter redox status and production of reactive oxygen species.

59 BASIC BIOLOGICAL SCIENCES↗

The extraction of true profiles for TPS commissioning and its impact on IMRT patient-specific QA

The aim of this work is to investigate the clinical impact of detector size effect on patient specific intensity-modulated radiation therapy (IMRT) quality assurance (QA). Two photon beam models, BM6 and BM4, were commissioned using photon beam profiles measured with a 6 mm diameter and a 4 mm diameter ion chambers, respectively. A method was developed to extract the ''true'' cross beam profiles, free of volume averaging effect, using analytic fitting/deconvolution. The method was validated using beam profiles measured with a small (0.8 mm) diode detector for small ({<=}10x10 cm{sup 2}) field sizes. These profiles were used to commission a third beam model (BM08). Planar dose distributions for eight IMRT plans (total of 53 fields) were calculated using the three beam models and measured with a two-dimensional detector array. Analysis using percent dose difference and distance-to-agreement criteria between the calculation and measurement was done to benchmark the performance of each beam model. The average passing rates between calculation and measurement were 93.8%, 98.9%, and 99.4% for BM6, BM4, and BM08, respectively, when 3%/3 mm criteria were used. A gradual increase in passing rates was noticed with the decrease in the size of the detector used to collect commissioning data. When 2%/2 mm criteria were used, the average passing rates increased significantly from 81.6% (BM6) to 92.6% (BM4) and 96.8% (BM08). These results quantify the enhancement of IMRT dose calculation accuracy with the reduction in detector size used for photon beam profiles measurement. Our study indicates that volume averaging effect can significantly affect the results of IMRT patient specific QA. By removing the detector size effect in beam commissioning, excellent passing rates can be achieved with more stringent criteria such as 2%/2 mm. The use of more stringent criteria for IMRT patient specific QA would likely result in higher chances of detecting any dosimetric errors arising from the treatment planning or delivery system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The sensitivity of patient specific IMRT QC to systematic MLC leaf bank offset errors

Purpose: Patient specific IMRT QC is performed routinely in many clinics as a safeguard against errors and inaccuracies which may be introduced during the complex planning, data transfer, and delivery phases of this type of treatment. The purpose of this work is to evaluate the feasibility of detecting systematic errors in MLC leaf bank position with patient specific checks. Methods: 9 head and neck (H and N) and 14 prostate IMRT beams were delivered using MLC files containing systematic offsets ({+-}1 mm in two banks, {+-}0.5 mm in two banks, and 1 mm in one bank of leaves). The beams were measured using both MAPCHECK (Sun Nuclear Corp., Melbourne, FL) and the aS1000 electronic portal imaging device (Varian Medical Systems, Palo Alto, CA). Comparisons with calculated fields, without offsets, were made using commonly adopted criteria including absolute dose (AD) difference, relative dose difference, distance to agreement (DTA), and the gamma index. Results: The criteria most sensitive to systematic leaf bank offsets were the 3% AD, 3 mm DTA for MAPCHECK and the gamma index with 2% AD and 2 mm DTA for the EPID. The criterion based on the relative dose measurements was the least sensitive to MLC offsets. More highly modulated fields, i.e., H and N, showed greater changes in the percentage of passing points due to systematic MLC inaccuracy than prostate fields. Conclusions: None of the techniques or criteria tested is sufficiently sensitive, with the population of IMRT fields, to detect a systematic MLC offset at a clinically significant level on an individual field. Patient specific QC cannot, therefore, substitute for routine QC of the MLC itself.

60 APPLIED LIFE SCIENCES↗

Patient-specific radiation dose and cancer risk estimation in CT: Part I. Development and validation of a Monte Carlo program

Purpose: Radiation-dose awareness and optimization in CT can greatly benefit from a dose-reporting system that provides dose and risk estimates specific to each patient and each CT examination. As the first step toward patient-specific dose and risk estimation, this article aimed to develop a method for accurately assessing radiation dose from CT examinations. Methods: A Monte Carlo program was developed to model a CT system (LightSpeed VCT, GE Healthcare). The geometry of the system, the energy spectra of the x-ray source, the three-dimensional geometry of the bowtie filters, and the trajectories of source motions during axial and helical scans were explicitly modeled. To validate the accuracy of the program, a cylindrical phantom was built to enable dose measurements at seven different radial distances from its central axis. Simulated radial dose distributions in the cylindrical phantom were validated against ion chamber measurements for single axial scans at all combinations of tube potential and bowtie filter settings. The accuracy of the program was further validated using two anthropomorphic phantoms (a pediatric one-year-old phantom and an adult female phantom). Computer models of the two phantoms were created based on their CT data and were voxelized for input into the Monte Carlo program. Simulated dose at various organ locations was compared against measurements made with thermoluminescent dosimetry chips for both single axial and helical scans. Results: For the cylindrical phantom, simulations differed from measurements by -4.8% to 2.2%. For the two anthropomorphic phantoms, the discrepancies between simulations and measurements ranged between (-8.1%, 8.1%) and (-17.2%, 13.0%) for the single axial scans and the helical scans, respectively. Conclusions: The authors developed an accurate Monte Carlo program for assessing radiation dose from CT examinations. When combined with computer models of actual patients, the program can provide accurate dose estimates for specific patients.

60 APPLIED LIFE SCIENCES↗

Using an EPID for patient-specific VMAT quality assurance

Purpose: A patient-specific quality assurance (QA) method was developed to verify gantry-specific individual multileaf collimator (MLC) apertures (control points) in volumetric modulated arc therapy (VMAT) plans using an electronic portal imaging device (EPID). Methods: VMAT treatment plans were generated in an Eclipse treatment planning system (TPS). DICOM images from a Varian EPID (aS1000) acquired in continuous acquisition mode were used for pretreatment QA. Each cine image file contains the grayscale image of the MLC aperture related to its specific control point and the corresponding gantry angle information. The TPS MLC file of this RapidArc plan contains the leaf positions for all 177 control points (gantry angles). In-house software was developed that interpolates the measured images based on the gantry angle and overlays them with the MLC pattern for all control points. The 38% isointensity line was used to define the edge of the MLC leaves on the portal images. The software generates graphs and tables that provide analysis for the number of mismatched leaf positions for a chosen distance to agreement at each control point and the frequency in which each particular leaf mismatches for the entire arc. Results: Seven patients plans were analyzed using this method. The leaves with the highest mismatched rate were found to be treatment plan dependent. Conclusions: This in-house software can be used to automatically verify the MLC leaf positions for all control points of VMAT plans using cine images acquired by an EPID.

61 RADIATION PROTECTION AND DOSIMETRY↗

Plate-specific gain map correction for the improvement of detective quantum efficiency in computed radiography

Purpose: The purpose of this work is to improve the noise power spectrum (NPS), and thus the detective quantum efficiency (DQE), of computed radiography (CR) images by correcting for spatial gain variations specific to individual imaging plates. CR devices have not traditionally employed gain-map corrections, unlike the case with flat-panel detectors, because of the multiplicity of plates used with each reader. The lack of gain-map correction has limited the DQE(f) at higher exposures with CR. This current work describes a feasible solution to generating plate-specific gain maps. Methods: Ten high-exposure open field images were taken with an RQA5 spectrum, using a sixth generation CR plate suspended in air without a cassette. Image values were converted to exposure, the plates registered using fiducial dots on the plate, the ten images averaged, and then high-pass filtered to remove low frequency contributions from field inhomogeneity. A gain-map was then produced by converting all pixel values in the average into fractions with mean of one. The resultant gain-map of the plate was used to normalize subsequent single images to correct for spatial gain fluctuation. To validate performance, the normalized NPS (NNPS) for all images was calculated both with and without the gain-map correction. Variations in the quality of correction due to exposure levels, beam voltage/spectrum, CR reader used, and registration were investigated. Results: The NNPS with plate-specific gain-map correction showed improvement over the noncorrected case over the range of frequencies from 0.15 to 2.5 mm{sup -1}. At high exposure (40 mR), NNPS was 50%-90% better with gain-map correction than without. A small further improvement in NNPS was seen from carefully registering the gain-map with subsequent images using small fiducial dots, because of slight misregistration during scanning. Further improvement was seen in the NNPS from scaling the gain map about the mean to account for different beam spectra. Conclusions: This study demonstrates that a simple gain-map can be used to correct for the fixed-pattern noise in a given plate and thus improve the DQE of CR imaging. Such a method could easily be implemented by manufacturers because each plate has a unique bar code and the gain-map for all plates associated with a reader could be stored for future retrieval. These experiments indicated that an improvement in NPS (and hence, DQE) is possible, depending on exposure level, over a wide range of frequencies with this technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of a novel 2D array dosimeter for patient-specific quality assurance with volumetric arc therapy

Purpose: In this study, the authors are evaluating a new, commercially available 2D array that offers 3D dose reconstruction for patient specific intensity modulated radiation therapy quality assurance (IMRT QA).Methods: The OCTAVIUS 4D system and its accompanying software (VERISOFT) by PTW were evaluated for the accuracy of the dose reconstruction for patient specific pretreatment IMRT QA. OCTAVIUS 4D measures the dose plane at the linac isocenter as the phantom rotates synchronously with the gantry, maintaining perpendicularity with the beam, by means of an inclinometer and a motor. The measurements collected during a volumetric modulated arc therapy delivery (VMAT) are reconstructed into a 3D dose volume. The VERISOFT application is used to perform the analysis, by comparing the reconstructed dose against the 3D dose matrix from the treatment planning system (TPS) that is computed for the same geometry and beam arrangement as that of the measurement. In this study, the authors evaluated the 3D dose reconstruction algorithm of this new system using a series of tests. Using the Octavius 4D phantom as the patient, dose distributions for various field sizes, beam orientations, shapes, and combination of fields were calculated using the Pinnacle3, TPS, and the respective DICOMRT dose was exported to the VERISOFT analysis software. Measurements were obtained by delivering the test treatment plans and comparisons were made based on gamma index, dose profiles, and isodose distribution analysis. In addition, output factors were measured and the dose linearity of the array was assessed. Those measurements were compared against measurements in water using a single, calibrated ionization chamber as well as calculations from Pinnacle for the same delivery geometries.Results: The number of voxels that met the 3%/3 mm criteria for the volumetric 3D gamma index analysis ranged from 92.3% to 98.9% for all the patient plans that the authors evaluated. 2D gamma analysis in the axial, sagittal, and coronal planes produced similar results to those in the 3D gamma analysis. The new detector system does not require an angular dependence correction because it rotates in synchrony with the gantry and the detector array maintains a constant SAD while always perpendicular to the beam axis. Output factors were within 2% when compared to ionization chamber measurements and Pinnacle calculations. Similar agreement was observed when testing the MU linearity (for MU values above 2) as well as dose rate effect.Conclusions: The OCTAVIUS 4D system has some unique characteristics that can potentially improve the patient specific pretreatment IMRT QA data collection and analysis. The ability of the software to reconstruct from the measurements the true 3D dose distribution in the phantom, provides a unique perspective for the medical physicist that evaluates a patient's QA plan.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of Gafchromic EBT2 and EBT3 for patient-specific quality assurance: Cranial stereotactic radiosurgery using volumetric modulated arc therapy with multiple noncoplanar arcs

Purpose: Patient-specific quality assurance in volumetric modulated arc therapy (VMAT) brain stereotactic radiosurgery raises specific issues on dosimetric procedures, mainly represented by the small radiation fields associated with the lack of lateral electronic equilibrium, the need of small detectors and the high dose delivered (up to 30 Gy). Gafchromic{sup TM} EBT2 and EBT3 films may be considered the dosimeter of choice, and the authors here provide some additional data about uniformity correction for this new generation of radiochromic films.Methods: A new analysis method using blue channel for marker dye correction was proposed for uniformity correction both for EBT2 and EBT3 films. Symmetry, flatness, and field-width of a reference field were analyzed to provide an evaluation in a high-spatial resolution of the film uniformity for EBT3. Absolute doses were compared with thermoluminescent dosimeters (TLD) as baseline. VMAT plans with multiple noncoplanar arcs were generated with a treatment planning system on a selected pool of eleven patients with cranial lesions and then recalculated on a water-equivalent plastic phantom by Monte Carlo algorithm for patient-specific QA. 2D quantitative dose comparison parameters were calculated, for the computed and measured dose distributions, and tested for statistically significant differences.Results: Sensitometric curves showed a different behavior above dose of 5 Gy for EBT2 and EBT3 films; with the use of inhouse marker-dye correction method, the authors obtained values of 2.5% for flatness, 1.5% of symmetry, and a field width of 4.8 cm for a 5 × 5 cm{sup 2} reference field. Compared with TLD and selecting a 5% dose tolerance, the percentage of points with ICRU index below 1 was 100% for EBT2 and 83% for EBT3. Patients analysis revealed statistically significant differences (p < 0.05) between EBT2 and EBT3 in the percentage of points with gamma values <1 (p= 0.009 and p= 0.016); the percent difference as well as the mean difference between calculated and measured isodoses (20% and 80%) were found not to be significant (p= 0.074, p= 0.185, and p= 0.57).Conclusions: Excellent performances in terms of dose homogeneity were obtained using a new blue channel method for marker-dye correction on both EBT2 and EBT3 Gafchromic{sup TM} films. In comparison with TLD, the passing rates for the EBT2 film were higher than for EBT3; a good agreement with estimated data by Monte Carlo algorithm was found for both films, with some statistically significant differences again in favor of EBT2. These results suggest that the use of Gafchromic{sup TM} EBT2 and EBT3 films is appropriate for dose verification measurements in VMAT stereotactic radiosurgery; taking into account the uncertainty associated with Gafchromic film dosimetry, the use of adequate action levels is strongly advised, in particular, for EBT3.

61 RADIATION PROTECTION AND DOSIMETRY↗

Isotope specific resolution recovery image reconstruction in high resolution PET imaging

Purpose: Measuring and incorporating a scanner-specific point spread function (PSF) within image reconstruction has been shown to improve spatial resolution in PET. However, due to the short half-life of clinically used isotopes, other long-lived isotopes not used in clinical practice are used to perform the PSF measurements. As such, non-optimal PSF models that do not correspond to those needed for the data to be reconstructed are used within resolution modeling (RM) image reconstruction, usually underestimating the true PSF owing to the difference in positron range. In high resolution brain and preclinical imaging, this effect is of particular importance since the PSFs become more positron range limited and isotope-specific PSFs can help maximize the performance benefit from using resolution recovery image reconstruction algorithms. Methods: In this work, the authors used a printing technique to simultaneously measure multiple point sources on the High Resolution Research Tomograph (HRRT), and the authors demonstrated the feasibility of deriving isotope-dependent system matrices from fluorine-18 and carbon-11 point sources. Furthermore, the authors evaluated the impact of incorporating them within RM image reconstruction, using carbon-11 phantom and clinical datasets on the HRRT. Results: The results obtained using these two isotopes illustrate that even small differences in positron range can result in different PSF maps, leading to further improvements in contrast recovery when used in image reconstruction. The difference is more pronounced in the centre of the field-of-view where the full width at half maximum (FWHM) from the positron range has a larger contribution to the overall FWHM compared to the edge where the parallax error dominates the overall FWHM. Conclusions: Based on the proposed methodology, measured isotope-specific and spatially variant PSFs can be reliably derived and used for improved spatial resolution and variance performance in resolution recovery image reconstruction. The benefits are expected to be more substantial for more energetic positron emitting isotopes such as Oxygen-15 and Rubidium-82.

62 RADIOLOGY AND NUCLEAR MEDICINE↗