Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spares”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Coverage of Axillary Lymph Nodes in Supine vs. Prone Breast Radiotherapy

Purpose: To compare the dosimetry of target and normal tissue when tangents with the breast tissue were applied in a subset of breast cancer patients who had undergone computed tomography (CT) planning both supine and prone. Methods and Materials: The CT images of 20 patients who had undergone simulation in supine and prone positions were used for planning. The axillary lymph node regions (level I-III), breast tissue, tumor bed, heart, and bilateral lungs were manually contoured. Standard tangent fields were designed for the whole breast to deliver a prescribed dose of 50 Gy. Dose-volume histograms were compared between the two sets. Results: In each patient, coverage of breast tissue and tumor bed was readily achieved by either technique. In either position, treatment of the nodal regions was inadequate. On average, the mean dose to the nodal regions for levels I-III was {approx}50% less in the prone as compared with the supine position. The mean ipsilateral lung volume receiving 95% of the prescribed dose was 6.3% in the supine position compared to 0.43% in the prone position. When planned supine, the mean heart volume receiving 30 Gy was 0.56% compared with 0.30% in the prone position. Conclusions: Planning in either position was found to achieve adequate coverage of the breast tissue and tumor bed for all patients. Lung was better spared prone. Coverage of axillary nodes was inadequate in either position, but further reduced in the prone vs. supine position. The choice of optimal setup should take into considerations stage and risk of nodal recurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Breast Cancer Regional Radiation Fields for Supraclavicular and Axillary Lymph Node Treatment: Is a Posterior Axillary Boost Field Technique Optimal?

Purpose: To assess whether using an anterior oblique supraclavicular (SCV) field with a posterior axillary boost (PAB) field is an optimal technique for targeting axillary (AX) lymph nodes compared with two computed tomography (CT)-based techniques: (1) an SCV field with an anterior boost field and (2) intensity-modulated radiotherapy (IMRT). Methods and Materials: Ten patients with CT simulation data treated with postmastectomy radiation that included an SCV field were selected for the study. Supraclavicular nodes and AX Level I-III nodes within the SCV field were contoured and defined as the treatment target. Plans using the three techniques were generated and evaluated for each patient. Results: The anterior axillary boost field and IMRT resulted in superior dose coverage compared with PAB. Namely, treatment volumes that received 105%, 80%, and 30% of prescribed dose for IMRT plans were significantly less than those for the anterior axillary boost plans, which were significantly less than PAB. For PAB and anterior axillary boost plans, there was a linear correlation between treatment volume receiving 105% of prescribed dose and maximum target depth. Furthermore, the IMRT technique resulted in better lung sparing and dose conformity to the target than anterior axillary boost, which again was significantly better than PAB. The maximum cord dose for IMRT was small, but higher than for the other two techniques. More monitor units were required to deliver the IMRT plan than the PAB plan, which was more than the anterior axillary boost plan. Conclusions: The PAB technique is not optimal for treatment of AX lymph nodes in an SCV field. We conclude that CT treatment planning with dose optimization around delineated target volumes should become standard for radiation treatments of supraclavicular and AX lymph nodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient-Specific Monte Carlo Dose Calculations for High-Dose-Rate Endorectal Brachytherapy With Shielded Intracavitary Applicator

Purpose: An integrated software platform was developed to perform a patient-specific dosimetric study on high-dose-rate {sup 192}Ir endorectal brachytherapy. Monte Carlo techniques were used to examine the perturbation effects of an eight-channel intracavitary applicator with shielding and a liquid-inflatable balloon. Such effects are ignored in conventional treatment planning systems that assume water-equivalent geometries. Methods and Materials: A total of 40 Task Group 43-based rectal patient plans were calculated using the PTRAN{sub C}T Monte Carlo photon transport code. The silicone applicator, tungsten or lead shielding, contrast solution-filled balloon, and patient anatomy were included in the simulations. The dose to water and dose to medium were scored separately. The effects of heterogeneities and uncertainties in source positioning were examined. A superposition calculation method using pregenerated Monte Carlo dose distributions about the shielded applicator in water was developed and validated for efficient treatment planning purposes. Results: On average, metal shielding decreases the mean dose to the contralateral normal tissues by 24% and reduces the target volume covered by the prescribed dose from 97% to 94%. Tissue heterogeneities contribute to dose differences of <1% relative to the prescribed dose. The differences in the dose volume indices between dose to water and dose to medium-based calculations were <1% for soft tissues, <2% for bone marrow, and >20% for cortical bone. A longitudinal shift of {+-}2.5 mm and a rotational shift of {+-}15{sup o} in applicator insertion reduced the target volume receiving the prescribed dose by {<=}4%. Conclusion: The shielded applicator improved dose conformity and normal tissue sparing; however, Task Group 43-based treatment planning might compromise target coverage by not accounting for shielding.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simultaneous Multitarget Irradiation Using Helical Tomotherapy for Advanced Hepatocellular Carcinoma With Multiple Extrahepatic Metastases

Purpose: The prognosis of hepatocellular carcinoma (HCC) patients with extrahepatic metastases is extremely poor. Helical tomotherapy, an image-guided, intensity-modulated radiotherapy system, can allow for simultaneous and precise targeting of multiple cancerous lesions, while sparing normal tissues. This study evaluated the feasibility and outcome of tomotherapy for advanced HCC with metastases. Patients and Methods: A total of 42 consecutive HCC patients with metastases were treated with tomotherapy using the Hi-Art system. A total of 152 intra- and extrahepatic lesions (3.5 lesions/patient) were treated simultaneously, with a dose of 51.03 Gy (range, 30-57.61) in 10 fractions. Transarterial chemolipiodolization using epirubicin (50 mg) and cisplatin (60 mg) was repeated in patients with intrahepatic HCC (mean size, 9.0 cm) after tomotherapy. Results: An objective response (complete response and partial response) was achieved in 45.2% of patients with intrahepatic tumors, 68.4% of patients with pulmonary lesions, 60.0% of patients with lymph node/adrenal lesions, and 66.7% of patients with soft-tissue metastases. The complete response rate for those with pulmonary and lymph node/adrenal metastases was 26.3% and 5.0%, respectively. The overall survival rate at 1 and 2 years was 50.1% and 14.9%, respectively, with a median survival of 12.3 months. The actuarial in-field tumor control rate for {<=}1 year was 79.0%. No cases of Grade 4-5 acute toxicity occurred. Conclusion: The results of this study have shown that helical tomotherapy is safe and feasible without major toxicities for the treatment of advanced HCC and results in excellent tumor control and a potential survival benefit. This approach is expected to be a useful palliative option for selected HCC patients with metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk of Hypogonadism From Scatter Radiation During Pelvic Radiation in Male Patients With Rectal Cancer

Purpose: Recent studies have reported fluctuations in sex hormones during pelvic irradiation. The objective of this study was to observe the effects of radiation on hormonal profiles for two treatment modalities: conventional external beam radiotherapy (EBRT) and high-dose-rate brachytherapy (HDRBT) given neoadjuvantly for patients with rectal cancer. Methods and Materials: Routine serum follicle stimulating hormone (FSH), luteinizing hormone (LH), and testosterone levels were collected from 119 consecutive male patients receiving either EBRT, using 45.0-50.4 Gy in 25-28 fractions with concurrent 5-fluorouracil chemotherapy or HDRBT using 26 Gy in 4 fractions. Results: Thirty patients with initially abnormal profiles were excluded. Profiles included in this study were collected from 51 patients treated with EBRT and 38 patients treated with HDRBT, all of whom had normal hormonal profiles before treatment. Mean follow-up times were 17 months for the entire patient cohort-14 and 20 months, respectively-for the EBRT and HDRBT arms. Dosimetry results revealed a mean cumulative testicular dose of 1.24 Gy received in EBRT patients compared with 0.27 Gy in the HDRBT group. After treatment, FSH and LH were elevated in all patients but were more pronounced in the EBRT group. The testosterone-to-LH ratio was significantly lower (p = 0.0036) in EBRT patients for tumors in the lower third of the rectum. The 2-year hypogonadism rate observed was 2.6% for HDRBT compared with 17.6% for EBRT (p = 0.09) for tumors in the lower two thirds of the rectum. Conclusion: HDRBT allows better hormonal sparing than EBRT during neoadjuvant treatment of patients with rectal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation-Induced Lymphocyte Apoptosis to Predict Radiation Therapy Late Toxicity in Prostate Cancer Patients

Purpose: To examine a potential correlation between the in vitro apoptotic response of lymphocytes to radiation and the risk of developing late gastrointestinal (GI)/genitourinary (GU) toxicity from radiotherapy for prostate cancer. Methods and Materials: Prostate cancer patients formerly enrolled in a randomized study were tested for radiosensitivity by using a radiation-induced lymphocyte apoptosis assay. Apoptosis was measured using flow cytometry-based Annexin-FITC/7AAD and DiOC{sub 6}/7AAD assays in subpopulations of lymphocytes (total lymphocytes, CD4+, CD8+ and CD4-/CD8-) after exposure to an in vitro dose of 0, 2, 4, or 8 Gy. Results: Patients with late toxicity after radiotherapy showed lower lymphocyte apoptotic responses to 8 Gy than patients who had not developed late toxicity (p = 0.01). All patients with late toxicity had apoptosis levels that were at or below the group mean. The negative predictive value in both apoptosis assays ranged from 95% to 100%, with sensitivity values of 83% to 100%. Apoptosis at lower dose points and in lymphocyte subpopulations had a weaker correlation with the occurrence of late toxicity. Conclusions: Lymphocyte apoptosis after 8 Gy of radiation has the potential to predict which patients will be spared late toxicity after radiation therapy. Further research should be performed to identify the specific subset of lymphocytes that correlates with late toxicity, followed by a corresponding prospective study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Survivin Expression as a Predictive Marker for Local Control in Patients With High-Risk T1 Bladder Cancer Treated With Transurethral Resection and Radiochemotherapy

Purpose: The objectives of this study were to investigate the expression of survivin in tumor samples from patients with high-risk T1 bladder cancer and to correlate its expression with clinicopathologic features as well as clinical outcomes after initial transurethral resection (TURBT) followed by radiotherapy (RT) or radiochemotherapy (RCT). Methods and Materials: Survivin protein expression was evaluated by immunohistochemistry on tumor specimen (n = 48) from the initial TURBT, and was correlated with clinical and histopathologic characteristics as well as with 5-year rates of local failure, tumor progression, and death from urothelial cancer after primary bladder sparring treatment with RT/RCT. Results: Survivin was not expressed in normal bladder urothelium but was overexpressed in 67% of T1 tumors. No association between survivin expression and clinicopathologic factors (age, gender, grading, multifocality, associated carcinoma in situ) could be shown. With a median follow-up of 27 months (range, 3-140 months), elevated survivin expression was significantly associated with an increased probability of local failure after TURBT and RCT/RT (p = 0.003). There was also a clear trend toward a higher risk of tumor progression (p = 0.07) and lower disease-specific survival (p = 0.10). Conclusions: High survivin expression is a marker of tumor aggressiveness and may help to identify a subgroup of patients with T1 bladder cancer at a high risk for recurrence when treated with primary organ-sparing approaches such as TURBT and RCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Erectile Function Durability Following Permanent Prostate Brachytherapy

Purpose: To evaluate long-term changes in erectile function following prostate brachytherapy. Methods and Materials: This study included 226 patients with prostate cancer and preimplant erectile function assessed by the International Index of Erectile Function-6 (IIEF-6) who underwent brachytherapy in two prospective randomized trials between February 2001 and January 2003. Median follow-up was 6.4 years. Pre- and postbrachytherapy potency was defined as IIEF-6 >= 13 without pharmacologic or mechanical support. The relationship among clinical, treatment, and dosimetric parameters and erectile function was examined. Results: The 7-year actuarial rate of potency preservation was 55.6% with median postimplant IIEF of 22 in potent patients. Potent patients were statistically younger (p = 0.014), had a higher preimplant IIEF (p < 0.001), were less likely to be diabetic (p = 0.002), and were more likely to report nocturnal erections (p = 0.008). Potency preservation in men with baseline IIEF scores of 29-30, 24-28, 18-23, and 13-17 were 75.5% vs. 73.6%, 51.7% vs. 44.8%, 48.0% vs. 40.0%, and 23.5% vs. 23.5% in 2004 vs. 2008. In multivariate Cox regression analysis, preimplant IIEF, hypertension, diabetes, prostate size, and brachytherapy dose to proximal penis strongly predicted for potency preservation. Impact of proximal penile dose was most pronounced for men with IIEF of 18-23 and aged 60-69. A significant minority of men who developed postimplant impotence ultimately regained erectile function. Conclusion: Potency preservation and median IIEF scores following brachytherapy are durable. Thoughtful dose sparing of proximal penile structures and early penile rehabilitation may further improve these results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bone Fractures Following External Beam Radiotherapy and Limb-Preservation Surgery for Lower Extremity Soft Tissue Sarcoma: Relationship to Irradiated Bone Length, Volume, Tumor Location and Dose

Purpose: To examine the relationship between tumor location, bone dose, and irradiated bone length on the development of radiation-induced fractures for lower extremity soft tissue sarcoma (LE-STS) patients treated with limb-sparing surgery and radiotherapy (RT). Methods and Materials: Of 691 LE-STS patients treated from 1989 to 2005, 31 patients developed radiation-induced fractures. Analysis was limited to 21 fracture patients (24 fractures) who were matched based on tumor size and location, age, beam arrangement, and mean total cumulative RT dose to a random sample of 53 nonfracture patients and compared for fracture risk factors. Mean dose to bone, RT field size (FS), maximum dose to a 2-cc volume of bone, and volume of bone irradiated to >=40 Gy (V40) were compared. Fracture site dose was determined by comparing radiographic images and surgical reports to fracture location on the dose distribution. Results: For fracture patients, mean dose to bone was 45 +- 8 Gy (mean dose at fracture site 59 +- 7 Gy), mean FS was 37 +- 8 cm, maximum dose was 64 +- 7 Gy, and V40 was 76 +- 17%, compared with 37 +- 11 Gy, 32 +- 9 cm, 59 +- 8 Gy, and 64 +- 22% for nonfracture patients. Differences in mean, maximum dose, and V40 were statistically significant (p = 0.01, p = 0.02, p = 0.01). Leg fractures were more common above the knee joint. Conclusions: The risk of radiation-induced fracture appears to be reduced if V40 <64%. Fracture incidence was lower when the mean dose to bone was <37 Gy or maximum dose anywhere along the length of bone was <59 Gy. There was a trend toward lower mean FS for nonfracture patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hyperfractionated Low-Dose (21 Gy) Radiotherapy for Cranial Skeletal Metastases in Patients With High-Risk Neuroblastoma

Purpose: To present a large experience (73 patients) using a standard radiotherapy (RT) protocol to prevent relapse in cranial sites where measurable metastatic neuroblastoma (NB), an adverse prognostic marker, is common. Methods and Materials: High-risk NB patients with measurable cranial disease at diagnosis or residual cranial disease after induction therapy had those sites irradiated with hyperfractionated 21 Gy; a brain-sparing technique was used for an extensive field. The patients were grouped according to the response to systemic therapy. Thus, when irradiated, Group 1 patients were in complete remission and Group 2 patients had primary refractory disease. Follow-up was from the start of cranial RT. Results: At 3 years, the 39 Group 1 patients had a progression-free survival rate of 51%; control of cranial disease was 79%. Two relapses involved irradiated cranial sites. Two other patients relapsed in the irradiated cranial sites 6 and 12 months after a systemic relapse. At 3 years, the 34 Group 2 patients had a progression-free survival rate of 33%; control of cranial disease was 52%. Group 2 included 19 patients who had residual cranial (with or without extracranial) disease. The cranial sites showed major (n = 13), minor (n = 2), or no response (n = 4) to RT. Five patients had progression in the cranial RT field at 10-27 months. Group 2 also included 15 patients who had persistent NB in extracranial, but not cranial, sites. Of these 15 patients, 2 relapsed in the irradiated cranial sites and elsewhere at 8 and 14 months. Cranial RT was well tolerated, with no Grade 2 or greater toxicity. Conclusion: Hyperfractionated 21-Gy cranial RT might help control NB and is feasible without significant toxicity in children.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Visual Outcome and Tumor Control After Conformal Radiotherapy for Patients With Optic Nerve Sheath Meningioma

Purpose: Optic nerve sheath meningioma (ONSM) is a rare tumor that almost uniformly leads to visual dysfunction and even blindness without intervention. Because surgical extirpation carries a high risk of postoperative blindness, vision-sparing treatment strategies are desirable. Methods and Materials: We retrospectively reviewed the outcomes of 25 patients (25 optic nerves) with ONSM, treated at a single institution with conformal fractionated radiotherapy by either stereotactic photon or proton radiation. Primary endpoints were local control and visual acuity. Results: The patients presented with symptoms of visual loss (21) or orbital pain (3) or were incidentally diagnosed by imaging (3). The mean age was 44 years, and 64% were female patients. The indication for treatment was the development or progression of symptoms. Of the patients, 13 were treated with photons, 9 were treated with protons, and 3 received a combination of photons and protons. The median dose delivered was 50.4 gray equivalents (range, 45-59.4 gray equivalents). Median follow-up after radiotherapy was 30 months (range, 3-168 months), with 3 patients lost to follow-up. At most recent follow-up, 21 of 22 patients (95%) had improved (14) or stable (7) visual acuity. One patient had worsened visual acuity after initial postirradiation improvement. Of the 22 patients, 20 (95%) had no radiographic progression. Three patients had evidence of asymptomatic, limited retinopathy on ophthalmologic examination, and one had recurrent ONSM 11 years after treatment. Conclusions: Highly conformal, fractionated radiation therapy for symptomatic primary ONSM provides tumor control and improvement in visual function in most cases, with minimal treatment-induced morbidity. Longer follow-up is needed to assess the durability of tumor control and treatment-related late effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Cisplatin on Parotid Gland Function in Concomitant Radiochemotherapy

Purpose: To determine the influence of concomitant radiochemotherapy with cisplatin on parotid gland tissue complication probability. Methods and Materials: Patients treated with either radiotherapy (n = 61) or concomitant radiochemotherapy with cisplatin (n = 36) for head-and-neck cancer were prospectively evaluated. The dose and volume distributions of the parotid glands were noted in dose-volume histograms. Stimulated salivary flow rates were measured before, during the 2nd and 6th weeks and at 4 weeks and 6 months after the treatment. The data were fit using the normal tissue complication probability model of Lyman. Complication was defined as a reduction of the salivary flow rate to less than 25% of the pretreatment flow rate. Results: The normal tissue complication probability model parameter TD{sub 50} (the dose leading to a complication probability of 50%) was found to be 32.2 Gy at 4 weeks and 32.1 Gy at 6 months for concomitant radiochemotherapy and 41.1 Gy at 4 weeks and 39.6 Gy at 6 months for radiotherapy. The tolerated dose for concomitant radiochemotherapy was at least 7 to 8 Gy lower than for radiotherapy alone at TD{sub 50}. Conclusions: In this study, the concomitant radiochemotherapy tended to cause a higher probability of parotid gland tissue damage. Advanced radiotherapy planning approaches such as intensity-modulated radiotherapy may be partiticularly important for parotid sparing in radiochemotherapy because of cisplatin-related increased radiosensitivity of glands.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk of Secondary Malignant Neoplasms From Proton Therapy and Intensity-Modulated X-Ray Therapy for Early-Stage Prostate Cancer

Purpose: To assess the risk of a secondary malignant neoplasm (SMN) from proton therapy relative to intensity-modulated radiation therapy (IMRT) using X-rays, taking into account contributions from both primary and secondary sources of radiation, for prostate cancer. Methods and Materials: A proton therapy plan and a 6-MV IMRT plan were constructed for 3 patients with early-stage adenocarcinoma of the prostate. Doses from the primary fields delivered to organs at risk of developing an SMN were determined from treatment plans. Secondary doses from the proton therapy and IMRT were determined from Monte Carlo simulations and available measured data, respectively. The risk of an SMN was estimated from primary and secondary doses on an organ-by-organ basis by use of risk models from the Committee on the Biological Effects of Ionizing Radiation. Results: Proton therapy reduced the risk of an SMN by 26% to 39% compared with IMRT. The risk of an SMN for both modalities was greatest in the in-field organs. However, the risks from the in-field organs were considerably lower with the proton therapy plan than with the IMRT plan. This reduction was attributed to the substantial sparing of the rectum and bladder from exposure to the therapeutic beam by the proton therapy plan. Conclusions: When considering exposure to primary and secondary radiation, proton therapy can reduce the risk of an SMN in prostate patients compared with contemporary IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Distribution in Bladder and Surrounding Normal Tissues in Relation to Bladder Volume in Conformal Radiotherapy for Bladder Cancer

Purpose: To estimate bladder movements and changes in dose distribution in the bladder and surrounding tissues associated with changes in bladder filling and to estimate the internal treatment margins. Methods and Materials: A total of 16 patients with bladder cancer underwent planning computed tomography scans with 80- and 150-mL bladder volumes. The bladder displacements associated with the change in volume were measured. Each patient had treatment plans constructed for a 'partially empty' (80 mL) and a 'partially full' (150 mL) bladder. An additional plan was constructed for tumor irradiation alone. A subsequent 9 patients underwent sequential weekly computed tomography scanning during radiotherapy to verify the bladder movements and estimate the internal margins. Results: Bladder movements were mainly observed cranially, and the estimated internal margins were nonuniform and largest (>2 cm) anteriorly and cranially. The dose distribution in the bladder worsened if the bladder increased in volume: 70% of patients (11 of 16) would have had bladder underdosed to <95% of the prescribed dose. The dose distribution in the rectum and intestines was better with a 'partially empty' bladder (volume that received >70%, 80%, and 90% of the prescribed dose was 23%, 20%, and 15% for the rectum and 162, 144, 123 cm{sup 3} for the intestines, respectively) than with a 'partially full' bladder (volume that received >70%, 80%, and 90% of the prescribed dose was 28%, 24%, and 18% for the rectum and 180, 158, 136 cm{sup 3} for the intestines, respectively). The change in bladder filling during RT was significant for the dose distribution in the intestines. Tumor irradiation alone was significantly better than whole bladder irradiation in terms of organ sparing. Conclusion: The displacements of the bladder due to volume changes were mainly related to the upper wall. The internal margins should be nonuniform, with the largest margins cranially and anteriorly. The changes in bladder filling during RT could influence the dose distribution in the bladder and intestines. The dose distribution in the rectum and bowel was slightly better with a 'partially empty' than with a 'full' bladder.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison Between Hybrid Direct Aperture Optimized Intensity-Modulated Radiotherapy and Forward Planning Intensity-Modulated Radiotherapy for Whole Breast Irradiation

Purpose: To investigate the planning efficiency and dosimetric characteristics of hybrid direct aperture optimized (hDAO) intensity-modulated radiotherapy (IMRT) compared with forward planning (FP)-IMRT for whole breast irradiation with two tangential beams. Methods and Materials: A total of 15 patients with left-sided breast cancer, categorized with three different breast volumes, were selected for this study. All patients were treated with FP plans to 50 Gy in 25 fractions. The hDAO plans were created by combining two open fields with eight segments in two tangential beam directions and were inversely optimized. Results: The FP and hDAO plans achieved similar breast coverage and sparing of critical organs. The volume of breast receiving 105% of the prescription dose was significantly smaller in the hDAO than in the FP plans: 25% vs. 63% (p = .008) for small, 22% vs. 57% (p = .005) for medium, and 28% vs. 53% (p = .005) for large breasts. Furthermore, the tumor cavity coverage was slightly better in the hDAO plans (92.4% vs. 90.9%). Conclusion: Compared with FP-IMRT, hDAO-IMRT provided dosimetric advantages, significantly reducing the size of the hot spot and slightly improving the coverage of the tumor cavity. In addition, hDAO-IMRT required less planning time and was less dependent on the planner's ability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Focal Salvage Guided by T{sub 2}-Weighted and Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Prostate Cancer Recurrences

Purpose: Salvage treatment of the entire prostate for local recurrent cancer after primary radiotherapy is associated with high toxicity rates. Our goal was to show that, using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) for the visualization of a recurrence, focal salvage treatment can be performed, with, potentially, a reduction in toxicity. Methods and Materials: We performed MRI, including a DCE sequence, in 7 patients with biopsy-proven locally recurrent prostate cancer. The specific regions of interest suspect for containing tumor were delineated using DCE and T{sub 2}-weighted MRI scans. Subsequently, focal salvage high-dose-rate brachytherapy plans were created to illustrate the principle of focal salvage. Total salvage treatment plans were also created for comparison. Results: The transfer constant (K{sup trans}) values from the DCE were 0.33-0.67 min{sup -1} for areas suspect for tumor and 0.07-0.25 min{sup -1} for normal tissue. In 4 cases, a focal salvage plan could be generated; 93-100% of the gross tumor volume was covered with the prescribed dose, with relative sparing of the bladder, rectum, and urethra. In the total salvage plans, 24-53% of the gross tumor volume was covered, and the organs at risk received high doses. In 3 cases, a focal salvage plan could not be created because of multifocal tumor, seminal vesicle extension, or capsular extension. Conclusion: Focal salvage treatment plans can be created in patients with local recurrent prostate cancer after radiotherapy. DCE-MRI supports the localization of the target area. This could lead to less toxicity in patients with local recurrent prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison of Volumetric Modulated Arc Therapy and Conventional Intensity-Modulated Radiotherapy for Frontal and Temporal High-Grade Gliomas

Purpose: Volumetric modulated arc therapy (VMAT), the predecessor to Varian's RapidArc, is a novel extension of intensity-modulated radiotherapy (IMRT) wherein the dose is delivered in a single gantry rotation while the multileaf collimator leaves are in motion. Leaf positions and the weights of field samples along the arc are directly optimized, and a variable dose rate is used. This planning study compared seven-field coplanar IMRT (cIMRT) with VMAT for high-grade gliomas that had planning target volumes (PTVs) overlapping organs at risk (OARs). Methods and Materials: 10 previously treated patients were replanned to 60 Gy in 30 fractions with cIMRT and VMAT using the following planning objectives: 98% of PTV covered by 95% isodose without violating OAR and hotspot dose constraints. Mean OAR doses were maximally decreased without reducing PTV coverage or violating hotspot constraints. We compared dose-volume histogram data, monitor units, and treatment times. Results: There was equivalent PTV coverage, homogeneity, and conformality. VMAT significantly reduced maximum and mean retinal, lens, and contralateral optic nerve doses compared with IMRT (p < 0.05). Brainstem, chiasm, and ipsilateral optic nerve doses were similar. For 2-Gy fractions, mean monitor units were as follows: cIMRT = 789 +- 112 and VMAT = 363 +- 45 (relative reduction 54%, p = 0.002), and mean treatment times (min) were as follows: cIMRT = 5.1 +- 0.4 and VMAT = 1.8 +- 0.1 (relative reduction 65%, p = 0.002). Conclusions: Compared with cIMRT, VMAT achieved equal or better PTV coverage and OAR sparing while using fewer monitor units and less time to treat high-grade gliomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Modulated Arc Therapy: Planning and Evaluation for Prostate Cancer Cases

Purpose: To develop an optimization method using volumetric modulated arc therapy (VMAT) and evaluate VMAT plans relative to the standard intensity-modulated radiotherapy (IMRT) approach in prostate cancer. Methods and Materials: A single gantry rotation was modeled using 177 equispaced beams. Multileaf collimator apertures and dose rates were optimized with respect to gantry angle subject to dose-volume-based objectives. Our VMAT implementation used conjugate gradient descent to optimize dose rate, and stochastic sampling to find optimal multileaf collimator leaf positions. A treatment planning study of 11 prostate cancer patients with a prescription dose of 86.4 Gy was performed to compare VMAT with a standard five-field IMRT approach. Plan evaluation statistics included the percentage of planning target volume (PTV) receiving 95% of prescribed dose (V95), dose to 95% of PTV (D95), mean PTV dose, tumor control probability, and dosimetric endpoints of normal organs, whereas monitor unit (MU) and delivery time were used to assess delivery efficiency. Results: Patient-averaged PTV V95, D95, mean dose, and tumor control probability in VMAT plans were 96%, 82.6 Gy, 88.5 Gy, and 0.920, respectively, vs. 97%, 84.0 Gy, 88.9 Gy, and 0.929 in IMRT plans. All critical structure dose requirements were met. The VMAT plans presented better rectal wall sparing, with a reduction of 1.5% in normal tissue complication probability. An advantage of VMAT plans was that the average number of MUs (290 MU) was less than for IMRT plans (642 MU). Conclusion: The VMAT technique can reduce beam on time by up to 55% while maintaining dosimetric quality comparable to that of the standard IMRT approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗