Thermomechanical analysis and modeling of involute-shaped fuel plates using the Cheverton–Kelley experiments for the High Flux Isotope Reactor

Three research reactors with involute-shaped fuel plates are pursuing conversion from highly enriched uranium to low-enriched uranium fuel. Various core design and safety evaluation studies are essential to assess the feasibility of the conversion. The use of 3D computational multiphysics codes is being explored in these analyses and therefore they must undergo a thorough evaluation and quality assurance process due to their potential impact on nuclear safety. Here, the Cheverton and Kelley physical tests performed in the late 1960s to investigate the deflections of HFIR’s outer plate under uniform pressure and temperature fields are simulated by employing commercially available computational codes, with the goals to (1) verify and validate the models and numerical solvers implemented in the codes for thermomechanical analysis of involute reactor plates and (2) to develop a benchmark computational test to evaluate future versions of existing software or newly developed computational codes. The results of the simulations showed good agreement with each other as well as against the Cheverton–Kelley experimental data. Some minor deviations were observed for a few multiphysics cases and their potential origins and impact on the analysis results is investigated in the paper. The validated models increase the confidence in using multiphysics codes to evaluate existing or new LEU designs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Formal Methods for Provably Secure Software and Firmware

This project addresses a gap observed in verifying the programming in embedded devices used in international arms control: namely verifying that embedded programming in an arms control device does exactly what it is supposed to do, no more and no less, every time without fail, and without disclosing unauthorized information accidentally or intentionally. In critical military, aerospace, and industrial safety systems this problem is sometimes addressed using formal methods (FM). This multi-year project seeks to identify formal methods toolsets useable in arms control regimes, with emphasis on applicability, ease of use, long term availability, and support.

formal methods, Arms Control Verification↗

Long-Term Carbon Injection Field Test for 90% Mercury Removal for a PRB Unit a Spray Dryer and Fabric Filter

The power industry in the U.S. is faced with meeting regulations to reduce the emissions of mercury compounds from coal-fired plants. Injecting a sorbent such as powdered activated carbon (PAC) into the flue gas represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. The purpose of this test program was to evaluate the long-term mercury removal capability, long-term mercury emissions variability, and operating and maintenance (O&M) costs associated with sorbent injection on a configuration being considered for many new plants. Testing was conducted by ADA Environmental Solutions (ADA) at Rocky Mountain Power’s (RMP) Hardin Station through funding provided by DOE/NETL, RMP, and other industry partners. The Hardin Station is a new plant rated at 121 MW gross that was first brought online in April of 2006. Hardin fires a Powder River Basin (PRB) coal and is configured with selective catalytic reduction (SCR) for NOx control, a spray dryer absorber (SDA) for SO2 control, and a fabric filter (FF) for particulate control. Based upon previous testing at PRB sites with SCRs, very little additional mercury oxidation from the SCR was expected at Hardin. In addition, based upon results from DOE/NETL Phase II Round I testing at Holcomb Station and results from similarly configured sites, low native mercury removal was expected across the SDA and FF. The main goal of this project was met—sorbent injection was used to economically and effectively achieve 90% mercury control as measured from the air heater (AH) outlet to the stack for a period of ten months. This goal was achieved with DARCO® Hg-LH, Calgon FLUEPAC®-MC PLUS and ADA Power PAC PREMIUM brominated activated carbons at nominal loadings of 1.5–2.5 lb/MMacf. An economic analysis determined the twenty-year levelized cost to be 0.87 mills/kW-hr, or $15,000/lb Hg removed. No detrimental effects on other equipment or plant operations were observed. The results of this project also filled a data gap for plants firing PRB coal and configured with an SCR, SDA, and FF, as many new plants are being designed today. Another goal of the project was to evaluate, on a short-term basis, the mercury removal associated with coal additives and coal blending with western bituminous coal. The additive test showed that, at this site, the coal additive known as KNX was affective at increasing mercury removal while decreasing sorbent usage. Coal blending was conducted with two different western bituminous coals, and West Elk coal increased native capture from nominally 10% to 50%. Two additional co-benefits were discovered at this site. First, it was found that native capture increased from nominally 10% at full load to 50% at low load. The effect is believed to be due to an increase in mercury oxidation across the SCR caused by a corresponding decrease in ammonia injection when the plant reduces load. Less ammonia means more active oxidation sites in the SCR for the mercury. The second co-benefit was the finding that high ammonia concentrations can have a negative impact on mercury removal by powdered activated carbon. For a period of time, the plant operated with a high excess of ammonia injection necessitated by the plugging of one-third of the SCR. Under these conditions and at high load, the mercury control system could not maintain 90% removal even at the maximum feed rate of 3.5 lb/MMacf (pounds of mercury per million actual cubic feet). The plant was able to demonstrate that mercury removal was directly related to the ammonia injection rate in a series of tests where the ammonia rate was decreased, causing a corresponding increase in mercury removal. Also, after the SCR was refurbished and ammonia injection levels returned to normal, the mercury removal performance also returned to normal. Another goal of the project was to install a commercial-grade activated carbon injection (ACI) system and integrate it with new-generation continuous emissions monitors for mercury (Hg-CEMs) to allow automatic feedback control on outlet mercury emissions. This was accomplished and the plant can now be operated to control carbon injection based on either the overall mercury removal or an outlet mercury emission rate. By integrating these systems, it was determined that the plant could reduce powdered activated carbon consumption, especially at low load, because, at Hardin, native mercury capture increases from less than 20% to about 50% at low load and the carbon injection rate can be decreased accordingly. Currently, the plant is operating to automatically control emissions to below 0.9 lb/TBtu (pounds of mercury per million British thermal units) at carbon loadings of 0.5 to 1.5 lb/MMacf. During the final phase of the Long-Term test, the ACI system was operated by plant personnel. The estimated O&M cost for a single Hg-CEM system is $15,500/yr. The Hg-CEMs performed well throughout the project. This project began shortly after Thermo Fisher first offered the Mercury Freedom System™ on a commercial basis and progressed though several iterations, improvements, and upgrades to the hardware and software. Indeed, there was a ten-fold increase in the precision and accuracy of the units during the course of the project due to several successful upgrades. In their present condition, the Hg-CEMs measure mercury to a precision of about ± 0.05 μg/wscm (micrograms of mercury per wet standard cubic meter of gas), and only require occasional fine-tuning of the calibration coefficients. The quality assurance/quality control (QA/QC) protocol required to keep the units operating at their optimal performance was also developed and perfected during the course of the project. ADA Environmental Solutions (ADA) developed a daily calibration procedure that surpasses the requirements specified in the Clean Air Mercury Rule (CAMR), and a weekly diagnostic program that ensures that the systems are operating properly and receive the necessary maintenance. For the most part, the systems passed the daily, weekly, and quarterly QA/QC requirements as well as four performance verification tests using the Ontario Hydro (O-H) and Sorbent Trap Methods (STM) for the first test and the EPA Method 30A (M30A) procedure for the remaining three. However, some improvements are still necessary before the system can meet all of the requirements. These involve tests that challenge the system with oxidized mercury (Hg+2). These tests could not be passed at Hardin in spite of trying several improvements suggested by ADA or Thermo Fisher.

20 FOSSIL-FUELED POWER PLANTS↗

ChemCam rock laser for Mars Science Laboratory "Curiosity"

Los Alamos has a long history of space-related instruments, tied primarily to its role in defense-related treaty verification. Space-based detectors have helped determine the differences between signals from lightning bolts and potential nuclear explosions. LANL-developed gamma-ray detection instruments first revealed the existence of what we now know as gamma-ray bursts, an exciting area of astrophysical research. And the use of LANL instruments on varied space missions continues with such products as the ChemCam rock laser for NASA, shown here. The Engineering Model of the ChemCam Mars Science Laboratory rover instrument arrived at NASA's Jet Propulsion Laboratory on February 6, 2008. The Flight Model was shipped in August, 2010 for installation on the rover at JPL. ChemCam will use imaging and laser-induced breakdown spectroscopy (LIBS) to determine rock and soil compositions on Mars, up to 9 meters from the rover. The engineering model is being integrated into the rover test bed for the development and testing of the rover software. The actual flight model components were concurrently assembled at Los Alamos and in Toulouse, France. The Mars Science Laboratory is scheduled to launch in 2011. Animations courtesy of JPL/NASA.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-203: Reconstruction of the Treatment Area by Use of Sinogram in Helical Tomotherapy

Purpose: TomoTherapy (Accuray Co.) has an image-guided radiotherapy system with megavoltage (MV) X-ray source and the on-board imaging device. With the MV computed tomography (MVCT), it became feasible to perform the efficient daily-3D registration of the patient position before each treatment delivery. This system also allows one to acquire the delivery sinogram during the actual treatment, which partly includes the information of the irradiated object. In this study, we try to develop the image reconstruction during treatment in helical Tomotherapy. Methods: Sinogram data were acquired during helical Tomotherapy delivery using an arc-shaped detector array that consists of 738 xenon-gas filled detector cells. In preprocessing, these were normalized by full air-scan data. A software program was developed that reconstructs 3D images during treatment with corrections as; (1) the regions outside the field were masked not to be added in the backprojection (a masking correction), and (2) each voxel of the reconstructed image was divided by the number of the X-ray passing through its voxel (a ray-passing correction). Results: Without masking and ray-passing corrections, the image reconstruction was failed. The masking correction made the image clear, however, the streak artifact was accompanied. The ray-passing correction reduced this artifact. Although the SNR (the ratio of mean to standard deviation in homogeneous region) and the contrast of the reconstructed image were slightly improved with the ray-passing correction, the masking correction only is enough for the visualization purpose. Conclusion: The visualization of the treatment area was feasible by use of the sinogram in helical Tomotherapy. This proposed method can be utilized in the treatment verification. This work was partly supported by JSPS KAKENHI 24234567. No COI, but the data in this paper were prepared by collaborators in Accuray.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-310: Does a Head-Mounted Ionization Chamber Detect IMRT Errors?

Purpose: The conventional plan verification strategy is delivering a plan to a QA-phantom before the first treatment. Monitoring each fraction of the patient treatment in real-time would improve patient safety. We evaluated how well a new detector, the IQM (iRT Systems, Germany), is capable of detecting errors we induced into IMRT plans of three different treatment regions. Results were compared to an established phantom. Methods: Clinical plans of a brain, prostate and head-and-neck patient were modified in the Pinnacle planning system, such that they resulted in either several percent lower prescribed doses to the target volume or several percent higher doses to relevant organs at risk. Unaltered plans were measured on three days, modified plans once, each with the IQM at an Elekta Synergy with an Agility MLC. All plans were also measured with the ArcCHECK with the cavity plug and a PTW semiflex 31010 ionization chamber inserted. Measurements were evaluated with SNC patient software. Results: Repeated IQM measurements of the original plans were reproducible, such that a 1% deviation from the mean as warning and 3% as action level as suggested by the manufacturer seemed reasonable. The IQM detected most of the simulated errors including wrong energy, a faulty leaf, wrong trial exported and a 2 mm shift of one leaf bank. Detection limits were reached for two plans - a 2 mm field position error and a leaf bank offset combined with an MU change. ArcCHECK evaluation according to our current standards also left undetected errors. Ionization chamber evaluation alone would leave most errors undetected. Conclusion: The IQM detected most errors and performed as well as currently established phantoms with the advantage that it can be used throughout the whole treatment. Drawback is that it does not indicate the source of the error.

60 APPLIED LIFE SCIENCES↗

GR-Athena++: Puncture Evolutions on Vertex-centered Oct-tree Adaptive Mesh Refinement

Numerical relativity is central to the investigation of astrophysical sources in the dynamical and strong-field gravity regime, such as binary black hole and neutron star coalescences. Current challenges set by gravitational-wave and multimessenger astronomy call for highly performant and scalable codes on modern massively parallel architectures. We present GR-Athena++, a general-relativistic, high-order, vertex-centered solver that extends the oct-tree, adaptive mesh refinement capabilities of the astrophysical (radiation) magnetohydrodynamics code Athena++. To simulate dynamical spacetimes, GR-Athena++ uses the Z4c evolution scheme of numerical relativity coupled to the moving puncture gauge. We demonstrate stable and accurate binary black hole merger evolutions via extensive convergence testing, cross-code validation, and verification against state-of-the-art effective-one-body waveforms. GR-Athena++ leverages the task-based parallelism paradigm of Athena++ to achieve excellent scalability. We measure strong-scaling efficiencies above 95% for up to ~1.2 × 10 4 CPUs and excellent weak scaling is shown up to ~10 5 CPUs in a production binary black hole setup with adaptive mesh refinement. GR-Athena++ thus allows for the robust simulation of compact binary coalescences and offers a viable path toward numerical relativity at exascale.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of MatriXX for IMRT and VMAT dose verifications in peripheral dose regions

Purpose: MatriXX is a two-dimensional ion chamber array designed for IMRT/VMAT (RapidArc, IMAT, etc.) dose verifications. Its dosimetric properties have been characterized for megavoltage beams in a number of studies; however, to the best of the authors' knowledge, there is still a lack of an investigation into its performance in the peripheral or low dose regions. In this work, the authors have carried out a systematic study on this issue. Methods: The authors compare the performance of MatriXX with a cylindrical ion chamber in solid water phantoms in the peripheral dose regions. The comparisons are performed for a number of typical irradiation conditions that involve different gantry and/or MLC motions, field sizes, and distances to the target including static gantry/open fields, static gantry/sweeping MLC gap (mimicking an IMRT delivery), dynamic gantry/oscillating sweeping MLC gap (mimicking a VMAT delivery), as well as clinical IMRT and VMAT plans. Results: MatriXX, when used according to the manufacturer's recommendations, is found to disagree with an ion chamber in peripheral dose regions. This disagreement has been attributed to four types of MatriXX errors, namely, positive bias, over-response to scattered doses, round-off error, and angular dependence, all of which contribute to dose inaccuracies in the peripheral regions. The positive bias, which is independent of the dose level, is cumulative when MatriXX operates in the movie mode. The accumulation is proportional to the number of movie frames (snaps) when the sampling time is greater than 500 ms and is proportional to the overall movie time for a sampling time shorter than 500 ms. This behavior suggests multiple sources of the bias. MatriXX is also found to over-respond to peripheral doses by about 2.0% for the regions investigated in this work (3-15 cm from the field edge), where phantom scatter and collimator scatter dominate. Round-off error is determined to be due to insufficient precision in conversion of the raw signals to MatriXX software data for low doses. Angular dependence is defined as the dose response of MatriXX at different gantry angles. Up to 8% difference in detector response has been observed between 0 deg. and 180 deg. Possible sources of these errors are discussed and a correction method is suggested. With corrections, MatriXX shows good agreement with the ion chamber in all cases involving different gantry and/or MLC dynamics, as well as the clinical plans. For both primary and peripheral doses, MatriXX shows dose linearity down to 2 cGy with an accuracy of within 1% of the local dose. Conclusions: The performance of MatriXX has been systematically evaluated in the peripheral dose regions. Major sources of error associated with MatriXX are identified and a correction method is suggested. This method has been successfully tested using both experimental and clinical plans. In all cases, good agreements between MatriXX and an ion chamber are achieved after corrections. The authors conclude that with proper corrections, MatriXX can be reliably used for peripheral dose measurements within the ranges studied.

60 APPLIED LIFE SCIENCES↗

SU-F-J-196: A Prototype System for Portal Imaging for Intensity Modulated Neutron Therapy

Purpose: Fast neutron therapy is offered at the University of Washington Medical Center for treatment of selected cancers. The hardware and control systems of the UW Clinical Neutron Therapy System are undergoing upgrades to enable delivery of IMNT. To clinically implement IMNT, dose verification tools need to be developed. We propose a portal imaging system that relies on the creation of positron emitting isotopes ({sup 11}C and {sup 15}O) through (n, 2n) reactions with a PMMA plate placed below the patient. After field delivery, the plate is retrieved from the vault and imaged using a reader that detects the annihilation photons. The pattern of activity produced in the plate provides information to reconstruct the neutron fluence map that can be compared to fluence maps from Monte Carlo (MCNP) simulations to verify treatment delivery. We have previously performed Monte Carlo simulations of the portal imaging system (GATE simulations) and the beam line (MCNP simulations). In this work, initial measurements using a prototype system are presented. Methods: Custom electronics were developed for BGO detectors read out with photomultiplier tubes (previous generation PET detectors from a CTI ECAT 953 scanner). Two detectors were placed in coincidence, with a detector separation of 2 cm. Custom software was developed to create the crystal look up tables and perform a limited angle planar reconstruction with a stochastic normalization. To test the initial capabilities of the system, PMMA squares were irradiated with neutrons at a depth of 1.5 cm and read out using the prototype system. Doses ranging from 10–200 cGy were delivered. Results: Using the prototype system, dose differences in the therapeutic range could be determined. Conclusion: The prototype portal imaging system is capable of detecting neutron doses as low as 10–50 cGy and shows great promise as a patient QA tool for IMNT.

60 APPLIED LIFE SCIENCES↗

Potential of discrete Gaussian edge feathering method for improving abutment dosimetry in eMLC-delivered segmented-field electron conformal therapy

Purpose: The purpose of this work was to investigate the potential of discrete Gaussian edge feathering of the higher energy electron fields for improving abutment dosimetry in the planning volume when using an electron multileaf collimator (eMLC) to deliver segmented-field electron conformal therapy (ECT). Methods: A discrete (five-step) Gaussian edge spread function was used to match dose penumbras of differing beam energies (6-20 MeV) at a specified depth in a water phantom. Software was developed to define the leaf eMLC positions of an eMLC that most closely fit each electron field shape. The effect of 1D edge feathering of the higher energy field on dose homogeneity was computed and measured for segmented-field ECT treatment plans for three 2D PTVs in a water phantom, i.e., depth from the water surface to the distal PTV surface varied as a function of the x-axis (parallel to leaf motion) and remained constant along the y-axis (perpendicular to leaf motion). Additionally, the effect of 2D edge feathering was computed and measured for one radially symmetric, 3D PTV in a water phantom, i.e., depth from the water surface to the distal PTV surface varied as a function of both axes. For the 3D PTV, the feathering scheme was evaluated for 0.1-1.0-cm leaf widths. Dose calculations were performed using the pencil beam dose algorithm in the Pinnacle{sup 3} treatment planning system. Dose verification measurements were made using a prototype eMLC (1-cm leaf width). Results: 1D discrete Gaussian edge feathering reduced the standard deviation of dose in the 2D PTVs by 34, 34, and 39%. In the 3D PTV, the broad leaf width (1 cm) of the eMLC hindered the 2D application of the feathering solution to the 3D PTV, and the standard deviation of dose increased by 10%. However, 2D discrete Gaussian edge feathering with simulated eMLC leaf widths of 0.1-0.5 cm reduced the standard deviation of dose in the 3D PTV by 33-28%, respectively. Conclusions: A five-step discrete Gaussian edge spread function applied in 2D improves the abutment dosimetry but requires an eMLC leaf resolution better than 1 cm.

61 RADIATION PROTECTION AND DOSIMETRY↗

Validating Intra-Plate Power Distributions in the Advanced Test Reactor

We report that the neutronics software, HELIOS, was validated in 2015 for performing core reload design and safety analysis of the Advanced Test Reactor. However, when HELIOS was benchmarked against historic fission-wire measurements (i.e., zero-power full-core measurements) a statistically resolved calculation-to-measurement bias was discovered. The azimuthal power along each fuel plate computed by HELIOS has consistently shown to under-predict measurements made by fission-wires in historic zero-power tests near the fuel element side-plates. It was hypothesized during the HELIOS software validation work, that this bias is attributable to local moderation in coolant vents in the side-plates axially just above and below the fission-wires on the fuel-plate edges. This work used detailed MCNP and MC21 models of the side-plate vents to test this hypothesis. By comparing the average azimuthal biases between HELIOS, and 2D and 3D MCNP models, and a 3D MC21 model, it was found that the HELIOS azimuthal bias is not due to the measurement.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Failure Impact Analysis of Key Management in AMI Using Cybernomic Situational Assessment (CSA)

In earlier work, we presented a computational framework for quantifying the security of a system in terms of the average loss a stakeholder stands to sustain as a result of threats to the system. We named this system, the Cyberspace Security Econometrics System (CSES). In this paper, we refine the framework and apply it to cryptographic key management within the Advanced Metering Infrastructure (AMI) as an example. The stakeholders, requirements, components, and threats are determined. We then populate the matrices with justified values by addressing the AMI at a higher level, rather than trying to consider every piece of hardware and software involved. We accomplish this task by leveraging the recently established NISTR 7628 guideline for smart grid security. This allowed us to choose the stakeholders, requirements, components, and threats realistically. We reviewed the literature and selected an industry technical working group to select three representative threats from a collection of 29 threats. From this subset, we populate the stakes, dependency, and impact matrices, and the threat vector with realistic numbers. Each Stakeholder s Mean Failure Cost is then computed.

Algorithms↗

Active High Assurance Authentication Protocol (AHAAP)

The AHAAP Maturation Project involves maturation and evaluation of a patented zero-trust tamper-resistant high-assurance session-less dynamic and active device authentication protocol that simultaneously authenticates identity and provides integrity verification in a single step, substantially reducing the risk of cyberattack, and eliminating the need for costly and complex conventional communication security systems requirements (i.e., cryptography, Public Key Infrastructure (PKI), and key management). These cybersecurity attributes of the technology must be preserved when applying the technology to different cybersecurity solutions, including Command & Control (C&C), Over-the-Air (OTA) update, Common Access Card (CAC), and distributed energy resource (DER) implementations, among others. The technology research objective is to test and verify that the cybersecurity attributes of the technology are not degraded in different cybersecurity applications. The primary technology development objective is to build minimum viable products to demonstrate the technology addresses today’s cybersecurity threats so that prospective investors, strategic partners, regulatory agencies, and commercial customers can interact with and assess the protection assured by the technology. The AHAAP Maturation Project goal is to develop, test, and validate one or more AHAAP implementations. The AHAAP Maturation Project tasks are: (i) engineer AHAAP implementation software, (ii) build a functional prototype that implements the AHAAP software for demonstration, testing, analysis, and evaluation purposes, and (iii) generate a report detailing the results of the AHAAP C&C software and hardware implementation. The final project deliverables are: (i) AHAAP software implementation and prototype, (ii) a report from Sandia National Laboratories detailing the results of the AHAAP implementations.

97 MATHEMATICS AND COMPUTING↗

Visualization of 3-Dimensional Vectors in a Dynamic Embryonic System—WormGUIDES

WormGUIDES is an open-source dynamic embryonic system designed to facilitate global understanding of cellular decisions in the developing nervous system of the nematode C. elegans. WormGUIDES was designed to allow investigation and exploration of the observational results of the C. elegans life cycle from laboratory experiments. In the process of a mechanistic C. elegans model development, some functionalities of WormGUIDES needed to be enhanced to support model validation and verification. Here in this study, a new way to visualize 3-dimentional vectors within WormGUIDES was investigated and presented. Then, the practical values of this method were demonstrated by visualizing two biologically significant directions (i.e., division orientation and cell polarity) of individual embryonic cells in C. elegans. Lastly, a mathematic approach was designed to illustrate the differences between these two sets of vectors and provide easy indications of the location of these individual cells that have large data discrepancies within the C. elegans embryonic system.

59 BASIC BIOLOGICAL SCIENCES↗

Euratom Fast Collar (EFC) Calibration Report

Neutron collars are used by international inspectorates to determine the amount of 235U in fresh LWR fuel assemblies. Standard neutron collars can operate in two modes: “fast” and “thermal”. In fast mode (using cadmium liners), thermal neutron are excluded from the assembly and the measurement results are not very sensitive to the presence of neutron poison loaded pins. In thermal mode, the thermal neutrons are affected by the presence of poison rods leading to significant effect, requiring corrections. These corrections depend on the declaration of the operator, reducing the independence of the inspectors’ measurements. The thermal mode signal is much higher than the fast mode signal and can give statistically acceptable results in ~600 seconds compared with ~1 hr for the fast mode. This report describes the calibration of a new fast neutron collar designed to use fast mode to reduce the effect of poison pins on verification measurements and with increased efficiency to reduce the measurement times to those normally used on inspection. The work was done in cooperation with the safeguards division of the European Commission and so the new collar is named the Euratom Fast Collar (EFC). The motivation and design work is presented in reference 2. The Monte Carlo simulations presented in reference 2 cover a larger parameter range than can be experimentally measured with the mock up assembly and so we base the performance on the simulation results, benchmarked to the measurements. The work presented here follows that of the “bible” of LWR fuel assembly measurements and uses the same mock-up assembly, with the same enriched, depleted and gadolinium poisoned fuel rods as were used in that work. Reference 1 describes how the measured count rate of the detector is corrected for AmLi source strength, electronic stability, efficiency, poison rods effects and heavy metal effects as well as other perturbing factors. These will be discussed below. INCC is the normal software that is used to collect and analyze neutron collar data. The results of this work have been formulated to fit into this existing INCC data analysis framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CODE-TO-CODE BENCHMARK STUDY FOR THERMAL STRESS MODELING AND PRELIMINARY ANALYSIS OF THE HIGH-TEMPERATURE SINGLE HEAT PIPE EXPERIMENT

Microreactors are very small nuclear reactors with typical thermal-energy output of up to 20 MWth. The microreactor concept is gaining more and more attention for safe, robust, and reliable supply of electricity for remote locations and to meet industrial process heat needs. Heat-pipe-cooled microreactor is one of the microreactors being investigated at Idaho National Laboratory. In the heat-pipe-cooled microreactor, heat pipes remove heat from the reactor core as a passive heat-transfer device, so the fluid circulation is not required for cooling, which can substantially simplify the overall reactor design. However, given the extremely high temperatures in the core region and potentially large temperature gradients across the structure materials, thermal stresses need to be well-analyzed to ensure structural integrity during normal operations and accident scenarios for the heat-pipe-cooled microreactor designs. This paper discusses finite element method-based thermal-stress analysis for the high-temperature single heat-pipe test article in the Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory, using two commercial software packages, Abaqus and STAR-CCM+. A code-to-code benchmark study was performed to crosscheck the model setup and capability of each code and to gain insights into the potential thermal stress concerns from the current experimental setup. It is observed the significant thermal stresses happen at the locations where the largest temperature gradients appeared between heat pipe and electric heater. The temperature fields have good agreements between Abaqus and STAR-CCM+, while the induced thermal stresses show modest deviations probably due to differences of meshing engines used in these two codes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of SAS4A/SASSYS-1 for Steady-State Single-Phase Natural Circulation

The development of numerical software for engineering applications requires the validation of the code against experimental benchmark datasets. To support the validation of SAS4A/SASSYS-1 in simulating the single-phase natural circulation within nuclear reactor systems, high-precision steady-state experiments are performed to capture single-phase natural circulation phenomena on an existing scaled facility with comprehensive instrumentation. Forced convection tests are designed precisely capturing the facility’s critical thermal-hydraulic parameters required for one-dimensional modeling, and a comprehensive single-phase natural circulation dataset is obtained with well-documented experimental uncertainty and facility description. Analysis and discussion based on the finalized dataset confirm the dataset’s ability in capturing dominant phenomena and address important physical interpretation of parameters. The dataset reported in this project provides a valuable benchmark resource for the validation of system analysis codes under single-phase natural circulation inside nuclear reactors. Validation of SAS4A/SASSYS-1 is then performed against the obtained benchmark dataset to confirm the capability of its physics model in simulating the steady-state single-phase natural circulation. The experimental facility is modeled in the candidate code. Solution verification is performed using Richardson-extrapolation-based estimators to quantify and restrict numerical errors from discretization. Numerical uncertainty originating from finite maximum pseudo-transient time is also quantified and restricted. Input uncertainty provided by the benchmark dataset is forward propagated through the candidate code, directly quantifying the simulation output in a Monte Carlo approach. The composition of the output uncertainty is further determined by the estimators of Sobol’ indices through a variance-based sensitivity analysis. With uncertainty quantified for each individual condition, detailed comparison between the simulation results and experimental data is performed covering the whole dataset, which shows consistent agreement for all important quantities. The validation activity reported in this project demonstrates that SAS4A/SASSYS-1 can predict the primary parameters with satisfactorily accuracy under steady-state single-phase natural circulation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Application of FARM to an IES scenario within the FORCE ecosystem

The FARM (Feasible Actuator Range Modifier) software module is a component of the RAVEN-based FORCE framework for analysis of Integrated Energy Systems (IES). FARM supports the HERON software module in the evaluation of the optimal dispatch by evaluating feasible set-points for the different IES unit components. Set-points are required to satisfy limits on both production variables (i.e., the variables to be optimized such as the electrical power, the hydrogen production rate, etc.) and process variables tied to the service life of equipment (e.g., steam flowrate, vessel pressure, turbine firing temperature, etc.). This problem is addressed by adopting a two-stage approach. First, the HERON power dispatcher determines set-points that meet the constraints on the former variables (e.g., power levels and power ramp rate limits). These constraints are called explicit constraints. Then, FARM adjusts these set-points to ensure the respect of the limits on the latter variables given the knowledge of the system physics acquired through machine learning algorithms. These constraints are called implicit constraints. From this standpoint, FARM constitutes a bridge between the HERON power dispatcher that adopts a simplified description of the IES unit (low-resolution physics) and the HYBRID high-fidelity models (high-resolution physics). The original version of the FARM software module (FARM-Alpha) was released by Argonne National Laboratory in January 2021. In the latest version of the code released in July 2022 (FARM-Delta), the Reference Governor (RG) algorithm was upgraded to a Multi-Input Multi-Output version from its original Single-Input Single-Output form. The RG algorithm acts to enforce constraints. With this improvement an IES unit is now treated as a single dynamic system from the standpoint of control. The crosstalk among components in an IES unit is now fully considered thereby ensuring a true optimization is obtained for those units that have multiple set-points. In this report, the capabilities of FARM-Delta operating within the FORCE ecosystem are demonstrated for an IES test case. The specific configuration of IES unit for this case was selected by the IES team with consultation from the Advanced Reactor IES Expert Group. A full TEA analysis that invoked HERON, HYBRID, FARM, and RAVEN was performed and serves to demonstrate how the latest modification to FARM algorithms (i.e., state variable selection, state-space matrices derivation, set-point verification) can shape setpoints that might otherwise compromise the health of equipment through accelerated wear and tear. In this specific test case, it was demonstrated that these algorithms ensure a more efficient utilization of steam resources to be shared by two different subsystems, namely Balance of Plant (BOP) and High-Temperature Steam Electrolysis (HTSE). Finally, some code improvements that can further enhance the user-friendliness are suggested.